JXJin Xiong

Jin Xiong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jin Xiong has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Jun-Fei Wang

    Department of Orthopedics, Nanjing Drum Tower Hospital, the affiliated hospital of Nanjing University Medical School, Nanjing, China

    4 shared publications
  • Yi-Xin Chen

    Department of Orthopedics, Nanjing Drum Tower Hospital, the affiliated hospital of Nanjing University Medical School, Nanjing, China

    4 shared publications
  • Yinhe Wang

    Department of Orthopaedics, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China

    4 shared publications
  • Hong-Fei Shi

    Department of Orthopaedics, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, No. 321 Zhongshan Road, Nanjing, China

    3 shared publications
  • Jun-Fei Wang

    Department of Orthopedics, Nanjing Drum Tower Hospital, the affiliated hospital of Nanjing University Medical School, Nanjing, China

    2 shared publications
  • Xu-Sheng Qiu

    Department of Orthopedics, Nanjing Drum Tower Hospital, the affiliated hospital of Nanjing University Medical School, Nanjing, China

    2 shared publications

Latest Publications

  • Retracted
    Open Access

    RETRACTED ARTICLE: Single volar locking plating for the intra- and extra-articular distal radius fractures with dorsal metaphyseal comminution

    by Xue-Yang Gui, Zhao-Hui Cheng, Hong-Fei Shi, Yi-Xin Chen, Jin Xiong, Jun-Fei Wang, Xu-Sheng Qiu, Zi-Tao Zhang

    Background: Volar locking plating remains a popular method for the surgical management of distal radius fractures. Dorsal metaphyseal comminution (DMC) is a common fracture pattern which weakens the stability during fracture fixation. In this study, we aimed to compare the radiographic and functional outcome of the intra- and extra-articular distal radius fractures with DMC following single volar locking plate fixation. Materials and methods: Patients suffered from a distal radius fracture with DMC were reviewed in the clinical database of the authors’ institution between Jan 2016 and Jan 2020. The included patients were classified into the extra-articular (A3) group or the intra-articular (C2 and C3) group according to the AO/OTA system. The radiological parameters, wrist range of motion, and functional outcomes were evaluated following open reduction and volar locking plate fixation. Results: A total of 130 patients were included in this study with a mean follow-up length of 17.2 months. Compared with the A3 fracture group, no significant fracture re-displacement or reduced wrist ROMs was observed in the C2 fractures after 12-month’s follow-up. However, significantly decreased volar tilt ( P = 0.003) as well as the extension/flexion ROMs were observed in the C3 fractures comparing to the A3 fractures. Most of the patients achieved an excellent (n = 75) or good (n = 51) Gartland and Werley wrist score. Four patients with C3 fractures resulted in a fair functional outcome due to a significant loss of volar tilt during follow-up. Conclusions: The single volar locking plate fixation provided sufficient stability for distal radius fractures with DMC, and resulted in similar radiological and functional outcomes in the intra-articular distal radius fractures with a simple articular component (C2 fractures) as those in the extra-articular fractures. Considering the intra-articular fractures with multifragmentary articular component (C3 fracture), despite of the subsequent loss of volar tilt, the majority of the patients achieved good to excellent wrist function following single volar locking plating. Trial registration: This study has been registered on the ClinicalTrials.gov.


  • Open Access

    A modified intrafocal pinning technique with three‐dimensional planning to facilitate volar plating in dorsally comminuted AO/OTA C2 and C3 distal radius fractures

    by Xue-Yang Gui, Hong-Fei Shi, Jin Xiong, Yi-Xin Chen, Jun-Fei Wang, Jie Huang, Xu-Sheng Qiu, Yin-He Wang

    Theaim of this study was to assess the efficacy of a modified intrafocal pinningtechnique with three-dimensional (3D) planning to facilitate volar plating in dorsally comminuted intra-articular distal radius fractures. Intotal 35 AO/OTA type C2 and C3 fractures were finally included.The 3D digital model of the fracture was reconstructed based on preoperative computedtomographic (CT) images, with the displacement of the comminuted dorsalfragment and the intra-articular fragment analyzed for preoperative planning. During operation, amodified intrafocal pinning technique was applied percutaneously from thedorsal aspect of the radius to reduce the collapsed intra-articular fragmentfollowing volar plating. Adequate reduction was confirmed in all of patientsconsidering radial height, radial inclination and volar tilt in postoperativeradiographs. No significant fracture re-displacement wasobserved in most of the cases during a mean follow-up period of 17.4 months, exceptfor two patients withthe C3 fracture. All of the patients achieved adequate clinicalROMs at 12 months postoperatively, with a mean DASH score of 12.0. Most of the patients achievedan excellent (n = 21) or good (n = 12) Gartland and Werley wrist score. Ourmodified intrafocal pinning technique with 3D planning contributes to a satisfactoryclinical and radiological outcome in dorsally comminuted intra-articular distalradius fractures fixed with a volar locking plate. Notapplicable because the design of the study is retrospective.


  • Open Access

    Comparison of the direct and indirect reduction techniques during the surgical management of posterior malleolar fractures

    by Hong-Fei Shi, Jin Xiong, Yi-Xin Chen, Jun-Fei Wang, Xu-Sheng Qiu, Jie Huang, Xue-Yang Gui, Si-Yuan Wen, Yin-He Wang

    The optimal method for the reduction and fixation of posterior malleolar fracture (PMF) remains inconclusive. Currently, both of the indirect and direct reduction techniques are widely used. We aimed to compare the reduction quality and clinical outcome of posterior malleolar fracture managed with the direct reduction technique through posterolateral approach or the indirect reduction technique using ligamentotaxis. Patients with a PMF involving over 25% of the articular surface were recruited and assigned to the direct reduction (DR) group or the indirect reduction (IR) group. Following reduction and fixation of the fracture, the quality of fracture reduction was evaluated in post-operative CT images. Clinical and radiological follow-ups were performed at 6 weeks, 3 months, 6 months, 12 months, and then at 6 month-intervals postoperatively. Functional outcome (AOFAS score), ankle range of motion, and Visual Analog Scale (VAS) were evaluated at the last follow-up. Statistical differences were compared between the DR and IR groups considering the patient demographics, quality of fracture reduction, AOFAS score, and VAS. Totally 116 patients were included, wherein 64 cases were assigned to the DR group and 52 cases were assigned to the IR group. The quality of fracture reduction was significant higher in the DR group (P = 0.038). In the patients who completed a minimum of 12 months’ follow-up, a median AOFAS score of 87 was recorded in the DR group, which was significantly higher than that recorded in the IR group (a median score of 80). The ankle range of motion was slightly better in the DR group, with the mean dorsiflexion restriction recorded to be 5.2° and 6.1° in the DR and IR group respectively (P = 0.331). Similar VAS score was observed in the two groups (P = 0.419). The direct reduction technique through a posterolateral approach provide better quality of fracture reduction and functional outcome in the management of PMF over 25% of articular surface, as compared with the indirect reduction technique using ligamentotaxis. NCT02801474 (retrospectively registered, June 2016, ClinicalTrails.gov).


  • Open Access

    Radiographic analysis of the restoration of hip joint center following open reduction and internal fixation of acetabular fractures: a retrospective cohort study

    by Hong-Fei Shi, Jin Xiong, Yi-Xin Chen, Jun-Fei Wang, Yin-He Wang

    Background: Unfavorable reduction is considered one of the key factors leading to joint degeneration and compromised clinical outcome in acetabular fracture patients. Besides the columns, walls, and superior dome, the postoperative position of hip joint center (HJC), which is reported to affect hip biomechanics, should be considered during the assessment of quality of reduction. We aimed to evaluate the radiographic restoration of HJC in acetabular fractures treated with open reduction and internal fixation.Methods: Patients with a displaced acetabular fracture that received open reduction and internal fixation in the authors’ institution during the past five years were identified from the trauma database. The horizontal and vertical shifts of HJC were measured in the standard anteroposterior view radiographs taken postoperatively. The radiographic quality of fracture reduction was graded according to Matta’s criteria. The relationships between the shift of HJC and the other variables were evaluated.Results: Totally 127 patients with 56 elementary and 71 associated-type acetabular fractures were included, wherein the majority showed a medial (89.0%) and proximal (93.7%) shift of HJC postoperatively. An average of 2.8 mm horizontal and 2.2 mm vertical shift of HJC were observed, which correlated significantly with the quality of fracture reduction (P < 0.001 for both). The horizontal shift of HJC correlated with the fracture type (P = 0.022).Conclusions: The restoration of HJC correlates with the quality of reduction in acetabular fractures following open reduction and internal fixation. Further studies are required to address the effects of HJC shift on the biomechanical changes and clinical outcomes of hip joint, especially in poorly reduced acetabular fractures.


  • Haploinsufficiency of endogenous parathyroid hormone‐related peptide impairs bone fracture healing

    by Yin‐He Wang, Yong Qiu, Xiao‐Dong Han, Jin Xiong, Yi‐Xin Chen, Hong‐Fei Shi, Andrew Karaplis

    Previous studies have demonstrated that endogenous parathyroid hormone-related peptide (PTHrP) plays a central role in the physiological regulation of bone formation. However, it is unclear whether endogenous PTHrP plays an important function in enhancing bone fracture healing. To determine whether endogenous PTHrP haploinsufficiency impaired bone fracture healing, closed mid-diaphyseal femur fractures were created in 8-week-old wild-type and Pthrp+/− mice. Callus tissue properties were analysed 1, 2 and 4 weeks after fracture by radiography, histology, histochemistry, immunohistochemistry and molecular biology. The size of the calluses was reduced 2 weeks after fracture, and the fracture repairs were poor 4 weeks after fractures, in Pthrp+/− compared with wild-type mice. Cartilaginous callus areas were reduced 1 week after fracture, but were increased 2 weeks after fracture in Pthrp+/− mice. There was a reduction in the number of ostoblasts, alkaline phosphatase (ALP)-positive areas, Type I collagen immunopositive areas, mRNA levels of ALP, Runt-related transcription factor 2 (Runx2) and Type I collagen, Runx2 and insulin-like growth factor-1 protein levels, the number of osteoclasts and the surface in callus tissues in Pthrp+/− compared with wild-type mice. These results demonstrate that endogenous PTHrP haploinsufficiency impairs the fracture repair process by reducing cartilaginous and bony callus formation, with downregulation of osteoblastic gene and protein expression and a reduction in endochondral bone formation, osteoblastic bone formation and osteoclastic bone resorption. Together, the results indicate that endogenous PTHrP plays an important role in fracture healing.


  • Open Access

    Early application of pulsed electromagnetic field in the treatment of postoperative delayed union of long-bone fractures: a prospective randomized controlled study

    by Hong-Fei Shi, Jin Xiong, Yi-Xin Chen, Jun-Fei Wang, Xu-Sheng Qiu, Yin-He Wang, Yong Qiu

    Background: Pulsed electromagnetic field (PEMF) is reported to be an effective adjunct for the management of nonunion long-bone fractures. Most studies implement PEMF treatment after 6 months or longer of delayed union or nonunion following fracture treatment. Despite these variations in treatment, the early application of PEMF following a diagnosis of a postoperative delayed union has not been specifically analyzed. In this study, the outcomes of postoperative delayed union of long-bone fractures treated with an early application of PEMF were evaluated as compared with a sham-treated control group.Methods: In this prospective, randomized controlled study, a total of 58 long-bone fracture patients, who presented with delayed union of between 16 weeks and 6 months, were randomly split into two groups and subjected to an early application of PEMF or sham treatment. Clinical and radiological assessments were performed to evaluate the healing status. Treatment efficacy was assessed at three month intervals.Results: Patients in the PEMF group showed a higher rate of union than those in the control group after the first three months of treatment, but this difference failed to achieve statistical significance. At the end of the study, PEMF treatment conducted for an average of 4.8 months led to a success rate of 77.4%. This was significantly higher than the control, which had an average duration of 4.4 months and a success rate of 48.1%. The total time from operation to the end of the study was a mean of 9.6 months for patients in the PEMF group.Conclusions: Fracture patients treated with an early application of PEMF achieved a significantly increased rate of union and an overall reduced suffering time compared with patients that receive PEMF after the 6 months or more of delayed union, as described by others.


  • Management of proximal humeral fractures in elderly patients with uni- or polyaxial locking osteosynthesis system

    by Hong-Fei Shi, Jin Xiong, Yi-Xin Chen, Jun-Fei Wang, Shou-Feng Wang, Zhi-Jun Chen, Yong Qiu

    To evaluate the clinical efficacy of uni- and polyaxial locking osteosynthesis systems in the management of proximal humeral fractures in elderly patients, totally 76 cases were reviewed including 18 cases of two-part (Neer classification), 36 cases of three-part, and 22 cases of four-part fractures.