Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Virgilio Ciancio has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Special Issue: Advances in Renewable Energy Systems

    by Ferdinando Salata, Virgilio Ciancio

    The greatest challenge that the industrialized world faces today is converting its energy production systems into those that utilize renewable sources, which are more environmentally friendly compared to traditional systems

  • Open Access

    A Preliminary Study of Summer Thermo-Hygrometric Comfort under Different Environmental Conditions in a Mediterranean City

    by Serena Falasca, Annalisa Di Bernardino, Virgilio Ciancio, Gabriele Curci, Ferdinando Salata

    The thermo-hygrometric sensation of pedestrians in outdoor environments can be quantified by means of bioclimatic indices. In this work, the Mediterranean Outdoor Thermal Comfort Index (MOCI) is applied in the city of Rome (Italy) for the purpose of investigating the effect of local environmental conditions (urban, suburban, rural) on pedestrian thermal comfort. Hourly values of MOCI are calculated for the May–September period in the years 2015–2021 using weather quantities acquired by the four monitoring stations of the Regional Agency for Environmental Protection included in the metropolitan area of Rome. MOCI data are analyzed based on the comfort and (cold/hot) discomfort conditions during both daytime and nighttime. At the urban station, 26% of daily records exceed the comfort threshold revealing the effect of urban overheating, whereas only 0.1% of hot discomfort occurrences are recorded overnight. Here, greater nighttime thermal comfort is experienced than in non-urban locations suggesting that the nocturnal thermo-hygrometric conditions are satisfactory for inhabitants in downtown Rome, despite the urban heat island. It also suggests that other factors, such as orography and atmospheric circulation, influence outdoor thermal comfort. The development of this work will therefore include at least these two elements.


  • A first approach to the optimization of landing and take-off operations through intelligent algorithms for compliance with the acoustic standards in multi-runway airports

    by Ferdinando Salata, Serena Falasca, Olga Palusci, Virgilio Ciancio, Anna Tarsitano, Vincenzo Battistini, Andrea Venditti, Lorenzo Cavina, Massimo Coppi


  • Open Access

    A First Approach to a New Index on Indoor Lighting Comfort Based on Corneal Illuminance

    by Ferdinando Salata, Iacopo Golasi, Antonio Peña-García, Virgilio Ciancio, Zahra Yousefi

    In this study, the conditions of visual comfort were assessed in an indoor environment intended for students. For this reason, a transversal field survey was carried out in two libraries, one at the Sapienza University of Rome (Italy) and another at the University of Granada (Spain). During the analysis, measurement of lighting engineering variables such as horizontal illuminance, corneal illuminance, and luminance was carried out at the same time. The randomly selected individuals were asked to compile the structured questionnaires voluntarily at both sites. The first part of the questionnaire covered personal information, such as gender, age, eye color, etc. While the latter part evaluated the perception and visual preference of interviewees. In particular, we analyzed the visual perception on the basis of a five-point scale (-2÷+2), where positive and negative values identified visual comfort and discomfort, respectively. Each point was related to both related measured values of the lighting project variables and values of the personal data derived from the questionnaires. The subsequent statistical analysis (carried out through parameters and methodologies such as evaluation of the Variance Inflation Factor, Multicollinearity and Best Subsets Analysis) allowed the development of a new empirical index that is easy to apply, i.e., the Predictive Visual Comfort Index (PVCI). Some of the independent variables included horizontal illuminance, corneal illuminance, and age. In the design phase, once the other variables had been set, it was useful to determine the necessity of corneal illuminance to ensure visual comfort. The influence of each variable on the index and visual comfort was also quantified. Header of solarlits.com


  • Open Access

    Resilience of a Building to Future Climate Conditions in Three European Cities

    by Virgilio Ciancio, Serena Falasca, Iacopo Golasi, Pieter de Wilde, Massimo Coppi, Livio de Santoli, Ferdinando Salata

    Building energy need simulations are usually performed using input files that contain information about the averaged weather data based on historical patterns. Therefore, the simulations performed are not able to provide information about possible future scenarios due to climate change. In this work, future trends of building energy demands due to the climate change across Europe were studied by comparing three time steps (present, 2050, and -2080) in three different European cities, characterized by different Köppen-Geiger climatic classes. A residential building with modern architectural features was taken into consideration for the simulations. Future climate conditions were reached by applying the effects of climate changes to current hourly meteorological data though the climate change tool world weather file generator (CCWorldWeatherGen) tool, according to the guidelines established by the Intergovernmental Panel on Climate Change. In order to examine the resilience of the building, the simulations carried out were compared with respect to: peak power, median values of the power, and energy consumed by heating and cooling system. The observed trend shows a general reduction in the energy needs for heating (–46% for Aberdeen, –80% for Palermo, –36% for Prague in 2080 compared to the present) and increase (occurrence for Aberdeen) in cooling requirements. These results imply a revaluation of system size.


  • Open Access

    Fire Temperature Based on the Time and Resistance of Buildings—Predicting the Adoption of Fire Safety Measures

    by Luciano Santarpia, Simone Bologna, Virgilio Ciancio, Iacopo Golasi, Ferdinando Salata

    During a fire in enclosed spaces, having structures with a good level of resistance is very important. The post flashover fire time interval, during which rescue squads operate, is important to verify if the structure can still resist fire for an acceptable time interval. This can be determined through the REI value. Hence, the way the fire develops must be examined together with the trend of the temperature that might guarantee that the structure will resist the heat flux released during the combustion. This article examines and compares, through a case study, the most important methods for analysis of the fire risk: the prescriptive approach and the simplified performance-based approach. The performance-based method (more suitable for the actual planning demand with respect to the more cautious prescriptive approach) is affected by the parameters influencing its development. The goal of this article is to provide a graph (based on parameters like the type of building, opening factor “O” and fire load “q”) that might be used by designers and architects to carry out the planning phase and adopt fire prevention systems before dealing with the assessments required by the engineering field for the fire risk analysis.


  • Open Access

    Influence of Input Climatic Data on Simulations of Annual Energy Needs of a Building: EnergyPlus and WRF Modeling for a Case Study in Rome (Italy)

    by Virgilio Ciancio, Serena Falasca, Iacopo Golasi, Gabriele Curci, Massimo Coppi, Ferdinando Salata

    The simulation of the energy consumptions in an hourly regime is necessary in order to perform calculations on residential buildings of particular relevance for volume or for architectural features. In such cases, the simplified methodology provided by the regulations may be inadequate, and the use of software like EnergyPlus is needed. To obtain reliable results, usually, significant time is spent on the meticulous insertion of the geometrical inputs of the building, together with the properties of the envelope materials and systems. Less attention is paid to the climate database. The databases available on the EnergyPlus website refer to airports located in rural areas near major cities. If the building to be simulated is located in a metropolitan area, it may be affected by the local heat island, and the database used as input to the software should take this phenomenon into account. To this end, it is useful to use a meteorological model such as the Weather Research and Forecasting (WRF) model to construct an appropriate input climate file. A case study based on a building located in the city center of Rome (Italy) shows that, if the climatic forcing linked to the heat island is not considered, the estimated consumption due to the cooling is underestimated by 35–50%. In particular, the analysis and the seasonal comparison between the energy needs of the building simulated by EnergyPlus, with the climatic inputs related to two airports in the rural area of Rome and with the inputs provided by the WRF model related to the center of Rome, show discrepancies of about (i) WRF vs. Fiumicino (FCO): Δ = −3.48% for heating, Δ = 49.25% for cooling; (ii) WRF vs. Ciampino (CIA): Δ = −7.38% for heating, Δ = +35.52% for cooling.


  • Open Access

    Air-conditioning in residential buildings through absorption systems powered by solar collectors

    by Anna Tarsitano, Virgilio Ciancio, Massimo Coppi