BKBoris B. Khlevnoy

Boris B. Khlevnoy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Boris B. Khlevnoy has a total of 172 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • VNIIOFI in the period 2016–2025: main results of scientific activity

    by A. S. Baturin, V. R. Gavrilov, A. V. Ivanov, V. N. Krutikov, A. D. Levin, E. A. Lavrukhina, A. P. Mamonov, V. L. Minaev, S. А. Moskalyuk, S. N. Negoda, et al.

    2025, 28 December All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI) is sixty. For this period Institute carry out many scientifi c researches, work out and supplied consumers thousands high-precision measurement technics (inclusive metrology standard equipment). The most significance for optical and physical measurements results of institute researches for period 2016–2025 presents in this article.

  • State primary standard for units of luminous intensity and luminous flux GET 5-2024

    by B. B. Khlevnoy, E. A. Ivashin, D. A. Otryaskin, I. A. Grigoryeva, D. V. Dobroserdov, M. V. Solodilov, S. A. Ogarev, V. R. Gavrilov, S. N. Negoda, I. S. Filimonov, et al.

    The history of the modernization of the national standard for the unit of luminous intensity in Russia is presented: from the establishment of the first state light standard in 1925 at Main Chamber of Weights and Measures (today – the D. I. Mendeleev Institute for Metrology) under the leadership of P. I. Tikhodeev to its current version – the State primary standard for units of luminous intensity and luminous fl ux GET 5-2024. As a result of the latest modernization, the GET 5-2024 now includes newly developed and manufactured by All-Russian Research Institute for Optical and Physical Measurements standard facilities, based on the latest research findings. For the first time in global practice, the unit of luminous intensity – the candela – is reproduced in GET 5-2024 using a high-temperature blackbody model operating at a fixed thermodynamic temperature of 2856.67 K, corresponding to the phase transition melting point of the molybdenum-carbon compound δ(MoC)-C. This approach has enabled an expanded uncertainty in the reproduction of the candela not exceeding 0.2 % at the level of 388.52 cd (with a coverage factor 2). Additionally, the use of a variable-temperature blackbody model allows for the reproduction of luminous intensity in the range from 1 to 20000 cd, with an expanded uncertainty not exceeding 0.24 % (with a coverage factor 2). The unit of total luminous fl ux – the lumen – is reproduced using a goniometric method with a specially developed goniophotometer. The reproduction range for luminous fl ux is from 1 to 3500 lm, with an expanded uncertainty of 0.22–0.28 % (with a coverage factor 2). Thus, the modernization of GET 5-2024 has extended the reproduction ranges of the units of luminous intensity and luminous fl ux and improved the accuracy of their realization. The improved GET 5-2024 allows the reproduction of the unit of luminous intensity in accordance with the recommendations of the International Committee of Weights and Measures, which ensures international compatibility of the results of scientific and applied measurements, their accuracy, and also contributes to improving the quality of industrial products, increasing transport safety, etc.


  • GET 5-2024 State primary standard of luminous intensity and luminous flux

    by Boris B. Khlevnoy, Evgeniy A. Ivashin, Denis A. Otryaskin, Evgenii V. Tishchenko, Irina A. Grigoryeva, Dmitriy V. Dobroserdov, Maksim V. Solodilov, Sergey A. Ogarev, Valery R. Gavrilov, Sergey N. Negoda, et al.

  • The candela realisation using molybdenum carbon fixed-point blackbody

    by Boris Khlevnoy, Irina Grigoryeva, Evgenii Ivashin, Denis Otryaskin, Maksim Solodilov

    Candela, a unit of luminous intensity, was realised with an expanded (k = 2) uncertainty of 0.20% using a fixed-point blackbody based on a molybdenum–carbon (δ(MoC)–C) melting phase transition. The developed δ(MoC)–C blackbody consists of a high-temperature furnace and a fixed-point cell filled with the molybdenum–carbon alloy. The cell includes a radiation cavity with a diameter as large as 14 mm, which allows it to be used in front of the blackbody, a relatively large external aperture, extracting the radiation emitted by the fixed-point cell only. The thermodynamic temperature of the δ(MoC)–C blackbody was measured by comparing it with the Re–C fixed point and was found to be 2856.67 K with the standard uncertainty of 0.23 K. Therefore, the developed fixed-point blackbody is an almost ideal International Commission on Illumination illuminant A source. With an external aperture of 4.9956 mm diameter, the blackbody reproduces a luminous intensity of 388.52 cd at the point-of-inflection of the melting plateau. The blackbody transfers the unit to a primary photometer with a relative expanded uncertainty of 0.20% in its illuminance responsivity, which can be used for calibration of secondary lamps and photometers.


  • COOMET key comparison COOMET.PR-K1.a.2018 for spectral irradiance 250 nm to 2500 nmm, final report

    by B B Khlevnoy, M V Solodilov, S S Kolesnikova, D A Otryaskin, I V Korseko, S V Nikanenka, M V Huriev, F Sametoğlu

    Main text: This report describes the Key Comparison COOMET.R-K1.a.2018 for spectral irradiance in the wavelength range of 250 nm to 2500 nm, conducted by the Regional Metrology Organization "Euro-Asian Cooperation of National Metrological Institutions" (COOMET). The comparison was, in fact, a combination of three bilateral comparisons with the same link/pilot laboratory - the All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), the Russian Federation. The non-link laboratories were the Belarusian State Institute of Metrology (BelGIM), Belarus, the National Scientific Centre "Institute of Metrology" (NSC IM), Ukraine, and the National Metrology Institute of Türkiye (TÜBİTAK UME), Türkiye. The aim of the comparison was to link the BelGIM, NSC IM and TÜBİTAK UME measurement results to the CIPM key comparison CCPR-K1.a.2017, conducted by the Consultative Committee for Photometry and Radiometry (CCPR). Tungsten quartz halogen lamps of the FEL type (1000 W) were used as artefacts. Each participant used its own set of lamps. The sequence of measurements was participant - pilot - participant. The pilot measurements of the described here COOMET comparison were performed in a short time (within three months) after completing the measurements of CCPR-K1.a.2017, where VNIIOFI also was a pilot, which provided a high quality link. NSC IM performed measurements in the full spectral range, from 250 nm to 2500 nm, while BelGIM and TÜBİTAK UME managed to cover the range from 250 nm to 1100 nm only. The analysis of the comparison was performed following the approach described in the Appendix A of the Guidelines for CCPR and RMO Bilateral Key Comparisons (CCPR-G5). Differences from KCRV of BelGIM and TÜBİTAK UME, for the most of the measured wavelengths, do not exceed 2% and are within the expanded uncertainties. For NSC IM the differences from KCRV are within or comparable with the uncertainties in the IR range, from 900 nm to 2500 nm, but become larger with decreasing wavelength in the visible and UV reaching 9% at 250 nm. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  • Furnace effect for the Re-C fixed point

    by Boris Khlevnoy, Irina Grigoryeva

    The furnace effect of the rhenium–carbon (Re–C) high-temperature fixed point was experimentally estimated by comparing the point-of-inflection temperature of the melting plateau demonstrated by the same Re–C cell in three furnaces of different dimensions. Two cells with the same outer size but different blackbody cavity designs were used. After corrections of the measured temperature for the size-of-source effect and the pyrometer stability, the furnace effect, estimated as the maximum change of the Re–C temperature from furnace to furnace, was found to be 0.094 K for the ‘best’ realisation of the fixed point. For the ‘normal’ realisation, additional components of the furnace effect, associated with non-optimal use of the fixed-point cell and furnace, were considered. The uncertainty components of the Re–C fixed point realisation associated with the furnace effect were estimated to be 0.060 K and 0.110 K for the best and normal cases, respectively.


  • CIPM key comparison CCPR-K1.a.2017 for spectral irradiance 250 nm to 2500 nm. Final report

    by B B Khlevnoy, M V Solodilov, S S Kolesnikova, D A Otryaskin, A Pons, J Campos, D J Shin, S Park, G Obein, M H Valin, et al.

    Main text: This report describes the Key Comparison of the Consultative Committee for Photometry and Radiometry CCPR-K1.a.2017 for Spectral Irradiance in the wavelength range of 250 nm to 2500 nm. Tungsten quartz halogen lamps of the FEL type (1000 W) were used as artefacts. Each participant used its own set of lamps. The star scheme of measurements was applied with the sequence participant - pilot - participant. Twelve National Metrology Institutes participated in the comparison. Each participant's measurement data were based on a totally independent spectral irradiance scale realisation. VNIIOFI (the Russian Federation) served as a pilot. The measurements were carried out from 2017 - 2020. The analysis of the comparison was performed following the step-by-step approach described in Appendix B of the Guidelines for CCPR Key Comparison Report Preparation (CCPR-G2 Rev.4). The key comparison reference values (KCRV) were calculated independently at each wavelength as the weighted means with cut-off. The measurement data of all participants were used for the KCRV excluding just a few outliers in the wavelength range of 1700 nm to 2500 nm. The relative uncertainties of the KCRV were minimal, 0.08 %, at the wavelengths of 900 nm to 1500 nm and increasing towards the limits of the spectral range up to 0.28 % at 250 nm and 0.20 % at 2500 nm. Consistency checks were satisfied at 17 of the 28 measured wavelengths, but failed at 11 wavelengths, mostly in the infrared range. For the latter wavelengths the Mandel-Paule method was applied resulting in an additional uncertainty that varied depending on wavelength from 0.11 % to 0.89 %. In general, the measurement uncertainties submitted by the participants in this comparison were less than those submitted in the previous CCPR-K1.a comparison. This is evidenced by the values of the cut-off, which had decreased at all wavelengths by a factor of 1.2 to 3.0 depending on wavelength. However, only for seven participants the degrees of equivalence do not exceed the expanded uncertainties at almost all wavelengths. About 80 % of all results (all participants at all wavelengths) agree with the KCRV within 1 % over the whole spectral range and within 0.7 % in the visible, which is comparable with the results of the previous CCPR-K1.a comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Open Access

    Spectral irradiance scale realization and uncertainty analysis based on a 14 mm diameter WC–C fixed point blackbody from 250 nm to 2500 nm

    by Caihong Dai, Yanfei Wang, Ling Li, Zhifeng Wu, Yihang Xie, Boris Khlevnoy, Irina Grigoryeva, Shufang He, Yandong Lin

    Spectral irradiance scale in the wavelength range from 250 nm to 2500 nm was realized at National Institute of Metrology on the basis of a large area tungsten carbide–carbon (WC–C) high temperature fixed point blackbody, which is composed of a 14 mm diameter WC–C fixed point cell and a variable temperature blackbody BB3500MP as a furnace. A series of 1000 W FEL tungsten halogen lamps were used as transfer standards. The new spectral irradiance scale was compared with the scale based on a variable-temperature blackbody BB3500M, and the divergence between these two methods varied from −0.66% to 0.79% from 280 nm to 2100 nm. The measurement uncertainty of spectral irradiance scale based on fixed-point blackbody was analyzed, and the expanded uncertainty was estimated as 3.9% at 250 nm, 1.4% at 280 nm, 0.43% at 400 nm, 0.27% at 800 nm, 0.25% at 1000 nm, 0.62% at 1500 nm, 0.76% at 2000 nm, and 2.4% at 2500 nm respectively. In the range from 300 nm to 1000 nm the fixed-point scale was improved obviously: the uncertainty decreased by more than 25% compared to the uncertainty based on the variable temperature blackbody. Below 300 nm, the uncertainty became higher because the signal to noise ratio was poor. Above 1100 nm, the contribution of temperature measurement to the uncertainty of spectral irradiance decreases, therefore the uncertainties of two methods are almost at the same level. The fixed-point blackbody was also used to realize the correlated colour temperature and distribution temperature of a tungsten filament lamp, the deviation from the variable temperature blackbody method was −0.5 K and −2.9 K, respectively.


  • COOMET.PR-S1 Comparison of whiteness and brightness. Final report

    by S S Shirokov, B B Khlevnoy, E A Ivashin, T B Gorshkova, O B Tarasova, D V Scums, A D Kupko, M V Huriev

    Main text: To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  • Assessment of Equivalence of the Spectral Radiance Scales Following the Results of the Comparison between the National Metrology Institutes of Korea, China, and Russia

    by Dong-Joo Shin, Boris B. Khlevnoy, Caihong Dai, Seongchong Park, Dong-Hoon Lee, Maxim V. Solodilov, Svetlana S. Kolesnikova, Zhifeng Wu, Yanfei Wang