JKJani Komppula

Jani Komppula

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jani Komppula has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    FCC-hh: The Hadron Collider

    by A. Abada, M. Abbrescia, S. S. AbdusSalam, I. Abdyukhanov, J. Abelleira Fernandez, A. Abramov, M. Aburaia, A. O. Acar, P. R. Adzic, P. Agrawal, et al.


  • A study of VUV emission and the extracted electron-ion ratio in hydrogen and deuterium plasmas of a filament-driven H−/D− ion source

    by J. Komppula, O. Tarvainen, T. Kalvas, H. Koivisto, P. Myllyperkiö, V. Toivanen

    Vacuum ultraviolet (VUV) emission diagnostics for studying differences of electron impact processes in hydrogen and deuterium plasmas are presented. The method is applied to study a filament driven multicusp arc discharge negative ion source by comparing the VUV-emission intensities of different emission bands and extracted currents of H−/D− ions and electrons. It was found that the ratio of coextracted electrons to extracted ions is four times higher for deuterium than for hydrogen. No significant differences of the VUV-spectra or volumetric rates of ionization, excitation, production of high vibrational states, and dissociation were found between the plasmas of the two isotopes. The volumetric rates of these electron impact processes are presented for both discharges. It is concluded that in the filament ion source, the observed difference of H−/D− production through dissociative electron attachment is due to different diffusion rates across the magnetic fields of the tandem-type discharge chamber rather than the production rate of ground state molecules at their vibrational levels.


  • Open Access

    FCC Physics Opportunities

    by The FCC Collaboration, A. Abada, M. Abbrescia, S. S. AbdusSalam, I. Abdyukhanov, J. Abelleira Fernandez, A. Abramov, M. Aburaia, A. O. Acar, P. R. Adzic, et al.


  • Top Cited Papers
    Open Access

    FCC-ee: The Lepton Collider

    by the FCC Collaboration, A. Abada, M. Abbrescia, S. S. AbdusSalam, I. Abdyukhanov, J. Abelleira Fernandez, A. Abramov, M. Aburaia, A. O. Acar, P. R. Adzic, et al.


  • Open Access

    Effect of crab cavity high order modes on the coupled-bunch stability of High-Luminosity Large Hadron Collider

    by S. A. Antipov, N. Biancacci, J. Komppula, E. Métral, B. Salvant, A. Burov

    High frequency high order modes can significantly affect the coupled-bunch stability in a circular accelerator. With a large enough shunt impedance they may drive a coupled-bunch transverse instability. We have developed an analytical model and implemented it in the nested head-tail Vlasov solver. The results show that the instability is characterized by the excitation of many azimuthal intrabunch modes, which have similar growth rates, that make the traditional remedies such as a flat resistive feedback and chromaticity inefficient in suppressing it. For the High Luminosity Large Hadron Collider this could result in a significant increase of the stabilizing Landau octupole current, up to ∼100 A (∼20% of the maximum available current). In order to limit the increase below 10 A (∼2%), the transverse shunt impedance has to be kept below 1  MΩ/m.


  • Microwave emission from ECR plasmas under conditions of two-frequency heating induced by kinetic instabilities

    by Vadim Skalyga, Ivan Izotov, Dmitry Mansfeld, Olli Tarvainen, Taneli Kalvas, Janne Laulainen, Risto Kronholm, Jani Komppula, Hannu Koivisto

    Multiple frequency heating is one of the most effective techniques to improve the performances of ECR ion sources. It has been demonstrated that the appearance of the periodic ion beam current oscillations in ECRIS at high heating power and low magnetic field gradient is associated with kinetic plasma instabilities. Recently it was proven that one of the main features of multiple frequency heating is connected with stabilizing effect, namely the suppression of electron cyclotron instability in ECRIS plasmas. Due to this kind of stabilization it is possible to run the ion source in stable mode using higher total microwave power and thus to obtain better ion beam parameters. Unfortunately, even with using of such technique at some threshold level the plasma becomes unstable. This work is devoted to experimental investigations of the peculiarities of cyclotron instability in the case of two-frequency heating. It was found out that the plasma microwave emission spectrum related to instabilities is affected by the division of injected power shared between the heating frequencies, though the main emission lines in the spectrum are proven to be independent on heating frequencies.


  • Dynamic regimes of cyclotron instability in the afterglow mode of minimum-Belectron cyclotron resonance ion source plasma

    by D Mansfeld, I Izotov, V Skalyga, O Tarvainen, T Kalvas, H Koivisto, J Komppula, R Kronholm, J Laulainen

    The paper is concerned with the dynamic regimes of cyclotron instabilities in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source operated in pulsed mode. The instability appears in decaying ion source plasma shortly (1–10 ms) after switching off the microwave radiation of the klystron, and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high-energy electrons along the magnetic field lines. Recently it was shown that this plasma instability causes perturbations of the extracted ion current, which limits the performance of the ion source and generates strong bursts of bremsstrahlung emission. In this article we present time-resolved diagnostics of electromagnetic emission bursts related to cyclotron instability in the decaying plasma. The temporal resolution is sufficient to study the fine structure of the dynamic spectra of the electromagnetic emission at different operating regimes of the ion source. It was found that at different values of magnetic field and heating power the dynamic spectra demonstrate common features: Decreasing frequency from burst to burst and an always falling tone during a single burst of instability. The analysis has shown that the instability is driven by the resonant interaction of hot electrons, distributed between the electron cyclotron resonance (ECR) zone and the trap center, with slow extraordinary wave propagation quasi-parallel with respect to the external magnetic field.


  • Cyclotron instability in the afterglow mode of minimum-B ECRIS

    by I. Izotov, T. Kalvas, H. Koivisto, J. Komppula, R. Kronholm, J. Laulainen, D. Mansfeld, V. Skalyga, O. Tarvainen

    It was shown recently that cyclotron instability in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source (ECRIS) causes perturbation of the extracted ion current and generation of strong bursts of bremsstrahlung emission, which limit the performance of the ion source. The present work is devoted to the dynamic regimes of plasma instability in ECRIS operated in pulsed mode. Instability develops in decaying plasma shortly after heating microwaves are switched off and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high energy electrons. Time-resolved measurements of microwave emission bursts are presented. It was found that even in various gases (helium and oxygen were studied) and at different values of magnetic field and heating power, the dynamic spectra demonstrate common features: decreasing frequency within a single burst as well as from one burst to another.


  • Ion source research and development at University of Jyväskylä: Studies of different plasma processes and towards the higher beam intensities

    by H. Koivisto, T. Kalvas, O. Tarvainen, J. Komppula, J. Laulainen, R. Kronholm, K. Ranttila, J. Tuunanen, T. Thuillier, D. Xie, et al.

    Several ion source related research and development projects are in progress at the Department of Physics, University of Jyväskylä (JYFL). The work can be divided into investigation of the ion source plasma and development of ion sources, ion beams, and diagnostics. The investigation covers the Electron Cyclotron Resonance Ion Source (ECRIS) plasma instabilities, vacuum ultraviolet (VUV) and visible light emission, photon induced electron emission, and the development of plasma diagnostics. The ion source development covers the work performed for radiofrequency-driven negative ion source, RADIS, beam line upgrade of the JYFL 14 GHz ECRIS, and the development of a new room-temperature-magnet 18 GHz ECRIS, HIISI.


  • Photoelectron emission from metal surfaces induced by radiation emitted by a 14 GHz electron cyclotron resonance ion source

    by Janne Laulainen, Taneli Kalvas, Hannu Koivisto, Jani Komppula, Risto Kronholm, Olli Tarvainen

    Photoelectron emission measurements have been performed using a room-temperature 14 GHz ECR ion source. It is shown that the photoelectron emission from Al, Cu, and stainless steel (SAE 304) surfaces, which are common plasma chamber materials, is predominantly caused by radiation emitted from plasma with energies between 8 eV and 1 keV. Characteristic X-ray emission and bremsstrahlung from plasma have a negligible contribution to the photoelectron emission. It is estimated from the measured data that the maximum conceivable photoelectron flux from plasma chamber walls is on the order of 10% of the estimated total electron losses from the plasma.