Somchai Urapepon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Somchai Urapepon has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Chonticha Subsomboon
Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
1 shared publication Pakamard Taenguthai
Takua-thung Hospital, Phang-nga, Thailand
1 shared publicationWarin Prachasujit
Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 15 (4) , 171-178
Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses
Subsomboon C, et al. J Adv Prosthodont. 2023 Aug;15(4):171-178. https://doi.org/10.4047/jap.2023.15.4.171
- 1 January 2023
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 15 (4) , 171-178
Open AccessEffect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses
Subsomboon C, et al. J Adv Prosthodont. 2023 Aug;15(4):171-178. https://doi.org/10.4047/jap.2023.15.4.171
- Open Access
- 1 January 2021
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 21 (4) , 425-429
Development of fibre-reinforced composite disk for computer-aided design-computer-aided manufacturing milled posts; Experimental composite disk using e-glass fibre in different fibre direction
Aims: To evaluate the flexural properties of computer-aided design-computer-aided manufacturing (CAD-CAM) milled posts fabricated from the experimental fibre-reinforced composite disks in different fibre direction, and to compare the flexural properties of the CAD-CAM milled posts to those of commercial prefabricated posts, RelyX and FRC PostecPlus. Settings and Design: In vitro comparative study. Materials and Methods: E-glass fibre was used to fabricate the CAD-CAM composite disks. The fibres were prepared in unidirectional and multidirectional arrangements into the epoxy resin, at 70% by weight. The disk was milled by the Cerec InLab CAD-CAM system to fabricate a post. Ten posts for each type of disk were prepared. Two types of commercial fibre posts, RelyX fibre post, and FRC PostecPlus were used as control. The three-point bending test was performed. Statistical Analysis Used: The data were analysed using one-way ANOVA and Game-Howell post-hoc test. Results: The results indicated that both commercial fibre posts had the highest flexural strength and flexural modulus. The unidirectional experimental post yielded significantly lower values in both flexural strengths (739.1 ± 24.1 MPa) and flexural modulus (21.0 ± 3.5 GPa) compared to the control posts, while the multidirectional experimental posts had extremely low flexural strength and flexural modulus. Conclusions: The direction of the fibres significantly influenced the mechanical properties of the posts. The experimental unidirectional fibre-reinforced composite disk showed the potential to be used as a CAD-CAM disk for post and core fabrication.
- 1 January 2021
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 21 (4) , 425-429
Open AccessDevelopment of fibre-reinforced composite disk for computer-aided design-computer-aided manufacturing milled posts; Experimental composite disk using e-glass fibre in different fibre direction
Aims: To evaluate the flexural properties of computer-aided design-computer-aided manufacturing (CAD-CAM) milled posts fabricated from the experimental fibre-reinforced composite disks in different fibre direction, and to compare the flexural properties of the CAD-CAM milled posts to those of commercial prefabricated posts, RelyX and FRC PostecPlus. Settings and Design: In vitro comparative study. Materials and Methods: E-glass fibre was used to fabricate the CAD-CAM composite disks. The fibres were prepared in unidirectional and multidirectional arrangements into the epoxy resin, at 70% by weight. The disk was milled by the Cerec InLab CAD-CAM system to fabricate a post. Ten posts for each type of disk were prepared. Two types of commercial fibre posts, RelyX fibre post, and FRC PostecPlus were used as control. The three-point bending test was performed. Statistical Analysis Used: The data were analysed using one-way ANOVA and Game-Howell post-hoc test. Results: The results indicated that both commercial fibre posts had the highest flexural strength and flexural modulus. The unidirectional experimental post yielded significantly lower values in both flexural strengths (739.1 ± 24.1 MPa) and flexural modulus (21.0 ± 3.5 GPa) compared to the control posts, while the multidirectional experimental posts had extremely low flexural strength and flexural modulus. Conclusions: The direction of the fibres significantly influenced the mechanical properties of the posts. The experimental unidirectional fibre-reinforced composite disk showed the potential to be used as a CAD-CAM disk for post and core fabrication.
- Open Access
- 1 January 2021
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 21 (2) , 192-197
The marginal and internal discrepancy of zirconia coping milled by two computer-aided design–computer-aided manufacturing systems
Aims: This study aimed to evaluate the marginal and internal discrepancy of the zirconia coping fabricated by two dental computer-aided design–computer-aided manufacturing (CAD-CAM) systems. Settings and Design: In vitro comparative study. Materials and Methods: Twenty zirconia crowns fabricated from inCoris ZI by Cerec InLab CAD-CAM system (Dentsply Sirona Inc, USA) and Ceramill ZI by Ceramill CAD-CAM system (Amann Girrbach, Austria) were measured the discrepancy at six locations using silicone replica technique. Absolute marginal discrepancy (AMD) and marginal gap (MG) represent the marginal discrepancy, and the other four locations at chamfer area, axial wall, cusp tip, and occlusal adaptation represent the internal discrepancy. The gap was measured using an optical light microscope at ×50 magnification. Statistical Analysis Used: The data were analyzed using two-way ANOVA and Game–Howell post hoc test. Results: The statistical analysis showed that the accuracy of zirconia coping depends on CAD-CAM system and the location of measurement. Cerec InLab showed the marginal discrepancy of the coping 119.5 ± 44.8 μm at MG position and 125.3 ± 36.6 μm at AMD position, which was statistically larger than Ceramill system did at 53.0 ± 12.1 μm and 67.2 ± 19.1 μm. On the other hand, the discrepancy in other positions showed no statistical difference between the two CAD-CAM systems. Conclusions: The accuracy of zirconia coping was significant affected by CAD-CAM system and the location of measurement.
- 1 January 2021
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 21 (2) , 192-197
Open AccessThe marginal and internal discrepancy of zirconia coping milled by two computer-aided design–computer-aided manufacturing systems
Aims: This study aimed to evaluate the marginal and internal discrepancy of the zirconia coping fabricated by two dental computer-aided design–computer-aided manufacturing (CAD-CAM) systems. Settings and Design: In vitro comparative study. Materials and Methods: Twenty zirconia crowns fabricated from inCoris ZI by Cerec InLab CAD-CAM system (Dentsply Sirona Inc, USA) and Ceramill ZI by Ceramill CAD-CAM system (Amann Girrbach, Austria) were measured the discrepancy at six locations using silicone replica technique. Absolute marginal discrepancy (AMD) and marginal gap (MG) represent the marginal discrepancy, and the other four locations at chamfer area, axial wall, cusp tip, and occlusal adaptation represent the internal discrepancy. The gap was measured using an optical light microscope at ×50 magnification. Statistical Analysis Used: The data were analyzed using two-way ANOVA and Game–Howell post hoc test. Results: The statistical analysis showed that the accuracy of zirconia coping depends on CAD-CAM system and the location of measurement. Cerec InLab showed the marginal discrepancy of the coping 119.5 ± 44.8 μm at MG position and 125.3 ± 36.6 μm at AMD position, which was statistically larger than Ceramill system did at 53.0 ± 12.1 μm and 67.2 ± 19.1 μm. On the other hand, the discrepancy in other positions showed no statistical difference between the two CAD-CAM systems. Conclusions: The accuracy of zirconia coping was significant affected by CAD-CAM system and the location of measurement.
- Open Access
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (2) , 146-150
The effect of zirconia framework design on the failure of all-ceramic crown under static loading
Urapepon S, et al. J Adv Prosthodont. 2015 Apr;7(2):146-150. http://dx.doi.org/10.4047/jap.2015.7.2.146
- 1 January 2015
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 7 (2) , 146-150
Open AccessThe effect of zirconia framework design on the failure of all-ceramic crown under static loading
Urapepon S, et al. J Adv Prosthodont. 2015 Apr;7(2):146-150. http://dx.doi.org/10.4047/jap.2015.7.2.146
- Open Access
- 1 January 2014
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 6 (3) , 194-199
Degree of conversion of resin composite cured by light through a translucent fiber posts
Urapepon S. J Adv Prosthodont. 2014 Jun;6(3):194-199. http://dx.doi.org/10.4047/jap.2014.6.3.194
- 1 January 2014
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 6 (3) , 194-199
Open AccessDegree of conversion of resin composite cured by light through a translucent fiber posts
Urapepon S. J Adv Prosthodont. 2014 Jun;6(3):194-199. http://dx.doi.org/10.4047/jap.2014.6.3.194