SHSang-Jin Han

Sang-Jin Han

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sang-Jin Han has a total of 106 co-authors. Here are the top co-authors by number of shared publications:

  • Hong Euy Lim

    Division of Cardiology, Department of Internal Medicine, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong, Korea

    7 shared publications
  • Jinhee Ahn

    Division of Cardiology, Department of Internal Medicine, Pusan National University School of Medicine and Pusan National University Hospital, Busan, Korea

    5 shared publications
  • Hyoung Soo Kim

    Department of Thoracic and Cardiovascular Surgery, Hallym University Sacred Heart Hospital, Anyang 14068, Republic of Korea

    4 shared publications
  • Dong Geum Shin

    Cardiology Division, Department of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea

    3 shared publications
  • Kyoung-Ha Park

    Division of Cardiovascular Disease, Hallym University Medical Center, Anyang 14068, Korea

    3 shared publications
  • Sun Hee Lee

    Department of Thoracic and Cardiovascular Surgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang 14066, Korea

    3 shared publications

Latest Publications

  • Open Access

    Deep Learning Model Using Transfer Learning for Detecting Left Ventricular Systolic Dysfunction: Retrospective Algorithm Development and Validation Study

    by Sungjae Lee, Jung-Woo Son, Sung-Ai Kim, Min-Soo Ahn, Sang Jun Lee, Sang-Jin Han, Taehyun Joo, Yeongyeon Na, Sunghoon Joo, Hyun Jin Ahn, et al.

    Background: Artificial intelligence–augmented electrocardiogram (AI-ECG) models for detecting left ventricular systolic dysfunction (LVSD) often exhibit degraded performance in patients with comorbidities. Objective: This study aimed to introduce and validate a recalibration method using longitudinal patient data to enhance prediction accuracy and simulate its clinical utility for ongoing monitoring. Methods: We conducted a multicenter, retrospective cohort study using data from 2 hospitals in Korea. A dataset of paired transthoracic echocardiograms (TTEs) and electrocardiograms (ECGs) matched within a 2-week interval was constructed, separating pairs into baseline (first for each patient) and follow-up assessments. In addition to conventional supervised learning, we developed a patient-wise recalibration strategy that incorporated historical left ventricular ejection fraction measurements and prior AI-ECG outputs to adjust for future predictions, thus empirically mitigating confounding effects. Pretraining was also implemented to enhance the model’s performance. Results: The recalibrated 12-lead DeepECG LVSD model achieved an area under the receiver operating curve of 0.956 (95% CI 0.946‐0.965) for internal validation and 0.940 (95% CI 0.936‐0.945) for external validation of follow-up TTE-ECG pairs. The uncalibrated 12-lead DeepECG LVSD model also showed modest performance, with an area under the receiver operating curve of 0.953 (95% CI 0.941‐0.965) in the internal validation and 0.947 (95% CI 0.943‐0.951) in the external validation when tested on baseline TTE-ECG pairs. Recalibration yielded statistically significant improvements in the 12-lead DeepECG LVSD models ( P <.001), with enhanced and more balanced performance across all clinical subgroups. Conclusions: Patient-wise recalibration improved accuracy and consistency across various comorbidities by mitigating performance degradation and bias. This broadens the application of AI-ECG for LVSD detection from low-risk screening to high-risk longitudinal monitoring.


  • Open Access

    Cryoballoon Ablation for Elderly Patients With Atrial Fibrillation: Results From the Korean Cryoballoon Registry

    by Dong-Seon Kang, Pil-Sung Yang, Jun-Hyung Kim, Ki-Hun Kim, Ju Youn Kim, So-Ryoung Lee, Junbeom Park, Sung Ho Lee, Chang Hee Kwon, Myung-Jin Cha, et al.

    Cryoballoon ablation (CBA) is considered an effective rhythm control treatment for atrial fibrillation (AF) and is increasing exponentially. However, data regarding the efficacy and safety of CBA in elderly patients are limited. A total of 2,652 patients (55.2% with non-paroxysmal AF) from the Korean CBA registry database with follow-up of ≥12-months after de novo CBA were divided into 2 groups based on age (<75 and ≥75 years old). Procedure related complications and clinical outcomes were compared. Compared to the control group (n=2,403), the elderly group (n=249) had female predominance (41.8% vs. 21.1%, p<0.001), a higher CHA₂DS₂-VASc scores (4.0 [3.0-5.0] vs. 2.0 [1.0-3.0]; p<0.001), and a higher prevalence of heart failure (33.3% vs. 21.9%; p<0.001) and chronic kidney disease (42.2% vs. 10.4%; p<0.001). A total of 120 procedure-related minor complications were reported, but no significant difference was observed between the 2 groups (6.4% vs. 4.3%; p=0.18). Recurrence of atrial tachyarrhythmias was observed in 67 patients (27.2%) in the elderly group and 788 patients (33.3%) in the control group. After adjusting for confounding variables, the freedom from atrial tachyarrhythmias during 24-month was similar between the 2 groups (67.0% vs. 62.7%; adjusted hazard ratio, 0.91; 95% confidence interval, 0.62-1.34; p=0.63). CBA showed a reasonable efficacy and safety profile in elderly population with AF, comparable to that in younger patients.


  • Open Access

    Does Merged three-dimensional mapping Improve Contact foRce and long-term procedure Outcome in Atrial Fibrillation ablation? (MICRO-AF study): A prospective randomized controlled study

    by Dong Geum Shin, Seung-Young Roh, Jinhee Ahn, Sang-Weon Park, Dong-Hyeok Kim, Sang-Jin Han, Hong Euy Lim

    Introduction: Integration of electroanatomical map (EAM) with preacquired three-dimensional (3D) cardiac images provides detailed appreciation of the complex anatomy of the left atrium (LA) and pulmonary vein (PV). High-density (HD) multi-electrode mapping catheters have enabled creating more accurate EAM reflecting real-time volume-rendered LA-PV geometry during atrial fibrillation (AF) ablation. However, no study has compared the outcomes of AF ablation using HD-EAM versus 3D-merged map. We aimed to investigate the procedural and clinical outcomes of AF ablation with HD-EAM (HD-EAM group) versus 3D-merged map (Merge group). Methods: One hundred patients (59.5±11.5years, 53% with paroxysmal AF [PAF]) were randomly assigned (1:1) to HD-EAM or Merged group. HD multi-electrode mapping and contact force (CF)-sensing catheters were used to create virtual LA-PV chamber and to perform wide antral circumferential ablation (WACA), respectively. Results: The two groups showed no significant differences in baseline characteristics and procedural data including ablation time, fluoroscopy time, LA voltage, and CF. PV isolation with a single WACA line was achieved in 21 (42%) and 27 (54%) patients in the Merge and HD-EAM groups, respectively (P=NS). CF was significantly lower in lesions with gap than lesions without gap after a single WACA (7.3±7.3 g vs. 16.0±8.3, respectively, P<0.001). During the 12-month follow-up, no significant difference in AF recurrence was observed between two groups, irrespective of AF type. In multivariate analysis, non-PAF was an independent risk factor for AF recurrence. Conclusion: Integration of 3D cardiac imaging did not improve procedural and clinical outcomes. HD-EAM provides an accurate real-time LA geometry.

  • Open Access

    Optimal Dose of Edoxaban for Very Elderly Atrial Fibrillation Patients at High Risk of Bleeding: The LEDIOS Registry

    by Ju Youn Kim, Juwon Kim, Seung-Jung Park, Kyoung-Min Park, Sang-Jin Han, Dae Kyeong Kim, Yae Min Park, Sung Ho Lee, Jong Sung Park, Young Keun On, et al.

    Kim JY, et al. Korean Circ J. 2024 May;54:e54. https://doi.org/10.4070/kcj.2024.0084


  • Open Access

    Comparison of Novel Telemonitoring System Using the Single-lead Electrocardiogram Patch With Conventional Telemetry System

    by Soonil Kwon, Eue-Keun Choi, So-Ryoung Lee, Seil Oh, Hee-Seok Song, Young-Shin Lee, Sang-Jin Han, Hong Euy Lim

    This study compared a novel telemonitoring system using a single-lead electrocardiogram (ECG) patch with a conventional telemonitoring system in a real-time inpatient setting. The novel telemonitoring system offers performance comparable to a conventional system while significantly reducing signal loss owing to the seamless wireless network through the dual-connection configuration between an ECG patch and neighboring gateways, efficiently communicated by the Bluetooth Low Energy protocol. The signal noise was also significantly reduced by preventing motion artifacts or poor contact between the electrodes and skin using a lightweight single-lead ECG patch.


  • Open Access

    Clinical Outcomes of Intracardiac Echocardiography-Guided Contrast Agent-Free Cryoballoon Ablation in Atrial Fibrillation Patients With Renal Insufficiency

    by Dong Geum Shin, Jinhee Ahn, Sang Hyun Park, Sang-Jin Han, Hong Euy Lim

    Shin DG, et al. Korean Circ J. 2023 Nov;54:e6. https://doi.org/10.4070/kcj.2023.0194


  • Open Access

    Safety and efficacy of intracardiac echocardiography–guided zero-fluoroscopic cryoballoon ablation for atrial fibrillation: a prospective randomized controlled trial

    by Jinhee Ahn, Dong Geum Shin, Sang-Jin Han, Hong Euy Lim

    The development of intracardiac echocardiography (ICE) has enabled fluoroless atrial fibrillation (AF) ablation using three-dimensional electroanatomical mapping systems. However, fluoroless cryoballoon ablation (CBA) remains challenging, mainly because of the lack of a visual mapping system. Hence, this study aimed to investigate the safety and efficacy of fluoroless CBA for AF under ICE guidance. Patients (n = 100) who underwent CBA for paroxysmal AF were randomly assigned to zero-fluoroscopic (Zero-X) and conventional groups. Intracardiac echocardiography was used to guide the transseptal puncture and catheter and balloon manipulation in all enrolled patients. The patients were prospectively followed for 12 months after CBA. The mean age was 60.4 years, and the left atrial (LA) size was 39.4 mm. Pulmonary vein isolation (PVI) was achieved in all patients. In the Zero-X group, fluoroscopy was used in only one patient because of unstable phrenic nerve capture during right-sided PVI. The procedure time and LA indwelling time in the Zero-X group were not statistically different compared with that in the conventional group. Fluoroscopic time (9.0 vs. 0.008 min) and radiation exposure (29.4 vs. 0.02 mGy) were significantly shorter in the Zero-X group than in the conventional group (P < 0.001). The complication rate did not differ between the two groups. During a mean follow-up of 663.3 ± 172.3 days, the recurrence rate was similar (16.0 vs. 18.0%; P = 0.841) between the groups. Multivariate analysis revealed that LA size was the only independent predictor of clinical recurrence. Intracardiac echocardiography–guided fluoroless CBA for AF was a feasible strategy without compromising acute and long-term success or complication rates.


  • Open Access

    A Multi-Center, Prospective Observational Study to Investigate the Safety, Compliance, and Efficacy of Omethyl QTlet Soft Capsule

    by You-Jeong Ki, Sang-Jin Han, Tae-Joon Cha, Jae Hyuk Lee, Eui Kyo Seo, Jae Won Yang, Won Min Hwang, Dong Kyu Jin, Joo-Hyun Park, Han Young Ryu, et al.

    Omega-3 fatty acids have been shown to be effective in lowering triglyceride (TG) levels; however, tolerability issues arise due to the large size of the pills. The purpose of this study was to examine the safety, compliance, and efficacy of Omethyl QTlet soft capsules (OQCs). This multi-center, prospective, observational study evaluated the safety, compliance, and efficacy of OQCs. Patients with hypertriglyceridemia with a history of omega-3 fatty acid intake were enrolled in this study and were prescribed OQCs (2 g–4 g/day) for eight weeks. All adverse events (AEs), adverse drug reactions (ADRs), and serious adverse events (SAEs) were recorded for safety evaluation. Adherence to treatment was assessed using questionnaires, and efficacy was assessed by changes in lipid and lipoprotein levels after eight weeks from baseline. The convenience of taking medication was analyzed for 580 patients, and the efficacy test was performed for 563 patients. The AE and ADR rates were 8.2% and 5.7%, respectively. There were only two SAEs. Of the patients, 55.8% responded that the OQC improved medication convenience, and mean changes in TG, total cholesterol, LDL-C, and non-HDL-C from baseline to eight weeks were −37.88 mg/dL, −11.56 mg/dL, −5.55 mg/dL, and −10.87 mg/dL, respectively (p-values < 0.001). In patients who had previously taken omega-3 fatty acids, OQCs showed safety and efficacy in lowering TG, and it was confirmed that compliance with medicine also improved compared to omega-3 fatty acids.


  • Safety of a single bolus administration of heparin without the measurement of activated clotting time during cryoballoon ablation: a prospective randomized controlled trial

    by Dong Geum Shin, Minwoo Lee, Jinhee Ahn, Sang-Jin Han, Hong Euy Lim

    Background Single-shot ablation has emerged as an effective technique for index atrial fibrillation (AF) ablation, with an advantage of short procedure time. Although recent guidelines recommend peri-procedural uninterrupted oral anticoagulants (OACs), the intra-procedural anticoagulation strategy remains uncertain under non-vitamin K OACs (NOACs). We investigated procedural safety of a single bolus administration of heparin without activated clotting time (ACT) measurement during cryoballoon ablation (CBA). Methods Two hundred patients (64.2 ± 10.0 years, 70% with non-paroxysmal AF) who underwent CBA with uninterrupted NOACs were randomly assigned to No-ACT group and ACT group. A bolus of heparin (100 U/kg) was routinely administered immediately after transseptal puncture. In the ACT group, an additional injection of heparin (30 U/kg) was administered if ACT at 30 min after the initial bolus was < 300 s. Results There were no differences in baseline characteristics including CHA2DS2-VASc score between the two groups. The left atrium indwelling and procedure times were 60.4 ± 13.1 min and 78.9 ± 13.9 min, respectively, and not significantly different between the two groups. The mean ACT was 335.2 ± 59.9 s in the ACT group. Any bleeding rate was 3.2% in all patients and there was no statistically significant difference in bleeding complications between the two groups. In the ACT group, groin hematoma, laryngopharyngeal bleeding, and hemoptysis occurred in 3, 1, and 1 patient, respectively. Cardiac tamponade occurred in 1 patient in the No-ACT group. No thromboembolic events occurred during the 30-day follow-up after CBA. Conclusions Single bolus administration of heparin without ACT measurement is a feasible anticoagulation strategy for CBA in patients with uninterrupted NOAC intake.


  • Open Access

    Safety of a single bolus administration of heparin without the measurement of activated clotting time during cryoballoon ablation: a prospective randomized controlled trial

    by Dong Geum Shin, Jinhee Ahn, Sang-Jin Han, Hong Euy Lim

    Introduction: Single-shot ablation has emerged as an effective technique for index atrial fibrillation (AF) ablation, with an advantage of short procedure time. Although recent guidelines recommend peri-procedural uninterrupted oral anticoagulants (OACs), the intra-procedural anticoagulation strategy remains uncertain under non-vitamin K OACs (NOACs). We investigated procedural safety of a single bolus administration of heparin without activated clotting time (ACT) measurement during cryoballoon ablation (CBA). Methods: Two hundred patients (64.2±10.0years, 70% with non-paroxysmal AF) who underwent CBA with uninterrupted NOACs were randomly assigned to No-ACT group and ACT group. A bolus of heparin (100 U/kg) was routinely administered immediately after transseptal puncture. In the ACT group, an additional injection of heparin (30 U/kg) was administered if ACT at 30-min after the initial bolus was <300 s. Results: There were no differences in baseline characteristics including CHA2DS2-VASc score between two groups. The left atrium indwelling and procedure times were 60.4±13.1 min and 78.9±13.9 min, respectively and not significantly different between two groups. The mean ACT was 335.2±59.9 s in the ACT group. Any bleeding rate was 3.2% in all patients and there was no statistically difference in bleeding complications between two groups. In the ACT group, groin hematoma, laryngopharyngeal bleeding, and hemoptysis occurred in 3, 1, and 1 patient, respectively. Cardiac tamponade occurred in 1 patient in the No-ACT group. No thromboembolic events occurred during the 30-day follow-up after CBA. Conclusion: Single bolus administration of heparin without ACT measurement is a feasible anticoagulation strategy for CBA in patients with uninterrupted NOACs intake.