Kenichi Kono
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenichi Kono has a total of 159 co-authors. Here are the top co-authors by number of shared publications:
Tomoaki Terada
Department of Neurosurgery, Showa University Northern Yokohama Hospital, Yokohama, Kanagawa, Japan
22 shared publicationsTakeshi Fujimoto
Department of Neurosurgery, Saito Memorial Hospital, Niigata, Japan
12 shared publicationsAki Shintani
10 shared publications- Yuya Sakakura
Department of Neurosurgery, NTT Medical Center Tokyo, Tokyo, Japan
9 shared publications Hideo Okada
7 shared publicationsYuko Tanaka
5 shared publications
Latest Publications
- Open Access
- 21 September 2026
- Published by Springer Nature in Clinical Neuroradiology
- p. 1-8
Clinical Implementation and Performance of Real-Time AI System for Device Tracking in Neurointervention: First U.S. Evaluation of Neuro-Vascular Assist
Purpose: To evaluate the first U.S.-based implementation, notification accuracy, and temporal operator response of Neuro-Vascular Assist. Methods: In a single-center study, 21 consecutive neurointerventional cases were performed using the AI system integrated with a biplane angiographic system. Procedures were classified as “Standard”, “Coil”, “Filter”, or “Venous”. Neuro-Vascular Assist tracked devices including guidewires, stents, coils, and filters in real-time. Visual and audio notifications were made based on device entry and exit in a determined region of interest. We classified these notifications as true positives (TP), false positives (FP), and false negatives (FN), and further assessed for temporal operator response (TOR). Results: The AI system was successfully integrated into the workflow without procedural delays or system failures affecting notification delivery. A total of 232 TPs, 13 FPs, and 17 FNs were recorded, resulting in an overall precision of 94.7% and recall of 93.2%. Among the 59 TP notifications evaluated for TOR, 25 (42.4%) were followed by an observable operator response within 10 s. These 25 positive TOR events represented 10.2% of all 245 notifications. Conclusion: Neuro-Vascular Assist was successfully implemented and demonstrated preliminary accuracy and feasibility in a U.S.-based neurointerventional setting. Larger prospective studies are warranted to determine whether real-time AI-assisted device tracking influences procedural decision-making, workflow, safety, or clinical outcomes.
- 21 September 2026
- Published by Springer Nature in Clinical Neuroradiology
- p. 1-8
Open AccessClinical Implementation and Performance of Real-Time AI System for Device Tracking in Neurointervention: First U.S. Evaluation of Neuro-Vascular Assist
Purpose: To evaluate the first U.S.-based implementation, notification accuracy, and temporal operator response of Neuro-Vascular Assist. Methods: In a single-center study, 21 consecutive neurointerventional cases were performed using the AI system integrated with a biplane angiographic system. Procedures were classified as “Standard”, “Coil”, “Filter”, or “Venous”. Neuro-Vascular Assist tracked devices including guidewires, stents, coils, and filters in real-time. Visual and audio notifications were made based on device entry and exit in a determined region of interest. We classified these notifications as true positives (TP), false positives (FP), and false negatives (FN), and further assessed for temporal operator response (TOR). Results: The AI system was successfully integrated into the workflow without procedural delays or system failures affecting notification delivery. A total of 232 TPs, 13 FPs, and 17 FNs were recorded, resulting in an overall precision of 94.7% and recall of 93.2%. Among the 59 TP notifications evaluated for TOR, 25 (42.4%) were followed by an observable operator response within 10 s. These 25 positive TOR events represented 10.2% of all 245 notifications. Conclusion: Neuro-Vascular Assist was successfully implemented and demonstrated preliminary accuracy and feasibility in a U.S.-based neurointerventional setting. Larger prospective studies are warranted to determine whether real-time AI-assisted device tracking influences procedural decision-making, workflow, safety, or clinical outcomes.
- 7 September 2026
- Published by Springer Nature in Clinical Neuroradiology
- p. 1-8
Real-Time AI-Generated Guidewire-Out-of-View Notifications in Diagnostic Cerebral Angiography: Higher Observed Rates Among Trainees
Purpose Evaluation of technical proficiency plays a critical role in ensuring the safety and efficacy of neuroendovascular procedures. However, objective and quantitative assessment methods that are suitable for clinical practice remain scarce or unavailable. To address this limitation, this study examined whether real-time notifications from intraoperative artificial intelligence (AI)-assisted systems can serve as objective indicators of procedural skills. Methods We retrospectively analyzed 200 consecutive digital subtraction angiography (DSA) cases performed at our institution using a real-time AI-assisted system called neuro-vascular assist (iMed Technologies, Tokyo, Japan). The procedures were performed by either board-certified neuroendovascular specialists with extensive experience or noncertified trainees. We compared AI notifications and procedural parameters between the groups and evaluated the association between certification status and AI notifications using mixed-effects logistic regression with a random intercept for operator and adjustment for case-mix. Results Univariate analysis revealed that trainees exhibited significantly higher frequency of AI notifications (62.5% vs 41.9%; P = 0.01) and longer fluoroscopy times (P = 0.02) compared to specialists. Furthermore, multivariable mixed-effects logistic regression accounting for case-mix and within-operator clustering showed twofold higher odds of an AI notification in trainees, but the association was not statistically significant (adjusted OR 2.10, 95% CI 0.68–6.49; P = 0.20). Conclusion This study provides preliminary evidence that intraoperative AI notifications may reflect differences in technical behavior according to operator certification status. Although the adjusted association was not statistically significant, these findings suggest the potential of AI-assisted systems as proof-of-concept tools for evaluating technical proficiency. Further validation involving a larger number of operators is required.
- 7 September 2026
- Published by Springer Nature in Clinical Neuroradiology
- p. 1-8
Real-Time AI-Generated Guidewire-Out-of-View Notifications in Diagnostic Cerebral Angiography: Higher Observed Rates Among Trainees
Purpose Evaluation of technical proficiency plays a critical role in ensuring the safety and efficacy of neuroendovascular procedures. However, objective and quantitative assessment methods that are suitable for clinical practice remain scarce or unavailable. To address this limitation, this study examined whether real-time notifications from intraoperative artificial intelligence (AI)-assisted systems can serve as objective indicators of procedural skills. Methods We retrospectively analyzed 200 consecutive digital subtraction angiography (DSA) cases performed at our institution using a real-time AI-assisted system called neuro-vascular assist (iMed Technologies, Tokyo, Japan). The procedures were performed by either board-certified neuroendovascular specialists with extensive experience or noncertified trainees. We compared AI notifications and procedural parameters between the groups and evaluated the association between certification status and AI notifications using mixed-effects logistic regression with a random intercept for operator and adjustment for case-mix. Results Univariate analysis revealed that trainees exhibited significantly higher frequency of AI notifications (62.5% vs 41.9%; P = 0.01) and longer fluoroscopy times (P = 0.02) compared to specialists. Furthermore, multivariable mixed-effects logistic regression accounting for case-mix and within-operator clustering showed twofold higher odds of an AI notification in trainees, but the association was not statistically significant (adjusted OR 2.10, 95% CI 0.68–6.49; P = 0.20). Conclusion This study provides preliminary evidence that intraoperative AI notifications may reflect differences in technical behavior according to operator certification status. Although the adjusted association was not statistically significant, these findings suggest the potential of AI-assisted systems as proof-of-concept tools for evaluating technical proficiency. Further validation involving a larger number of operators is required.
- 25 June 2026
- Published by BMJ in Journal of NeuroInterventional Surgery
Multicenter evaluation of real-time artificial intelligence assistance for carotid artery stenting
Background: Unintended device movement during carotid artery stenting (CAS) may lead to procedural complications. Our previous preliminary single-center study using a real-time artificial intelligence (AI) assistance system suggested that AI may help detect such movements and offer potential clinical usefulness; however, the small sample size limited the strength of the findings. In this multicenter study, we aimed to validate the accuracy and clinical utility of this real-time AI system in a diverse cohort. Methods: A total of 53 consecutive CAS procedures with distal filter protection were performed at three institutions under real-time AI monitoring. The AI system continuously analyzed fluoroscopic images and issued notifications when filter devices, guiding catheters, or guidewires moved outside predefined areas or went off-screen. Two types of distal filter protection devices were used. The participating institutions used two angiography systems. The efficacy, safety, and accuracy of the software were evaluated. Subgroup analyses were performed by filter type and operator experience. Results: On average, there were 13.1 AI notifications per case, including 11.4 true positives and 1.7 false positives. The overall precision and recall were 87% and 98%, respectively. In 32% of true positive notifications, the operator adjusted the inappropriate device position after the notification. No significant differences were observed across filter types or operator experience. No AI-related complications were observed. Conclusion: This multicenter study demonstrated consistent performance of real-time AI-assisted notifications of device movement during CAS across multiple institutions and operators. The system showed high accuracy and supports its integration into standard neuroendovascular workflows.
- 25 June 2026
- Published by BMJ in Journal of NeuroInterventional Surgery
Multicenter evaluation of real-time artificial intelligence assistance for carotid artery stenting
Background: Unintended device movement during carotid artery stenting (CAS) may lead to procedural complications. Our previous preliminary single-center study using a real-time artificial intelligence (AI) assistance system suggested that AI may help detect such movements and offer potential clinical usefulness; however, the small sample size limited the strength of the findings. In this multicenter study, we aimed to validate the accuracy and clinical utility of this real-time AI system in a diverse cohort. Methods: A total of 53 consecutive CAS procedures with distal filter protection were performed at three institutions under real-time AI monitoring. The AI system continuously analyzed fluoroscopic images and issued notifications when filter devices, guiding catheters, or guidewires moved outside predefined areas or went off-screen. Two types of distal filter protection devices were used. The participating institutions used two angiography systems. The efficacy, safety, and accuracy of the software were evaluated. Subgroup analyses were performed by filter type and operator experience. Results: On average, there were 13.1 AI notifications per case, including 11.4 true positives and 1.7 false positives. The overall precision and recall were 87% and 98%, respectively. In 32% of true positive notifications, the operator adjusted the inappropriate device position after the notification. No significant differences were observed across filter types or operator experience. No AI-related complications were observed. Conclusion: This multicenter study demonstrated consistent performance of real-time AI-assisted notifications of device movement during CAS across multiple institutions and operators. The system showed high accuracy and supports its integration into standard neuroendovascular workflows.
- 13 May 2026
- Published by Wolters Kluwer Health in Neurosurgery
Real-Time Artificial Intelligence Assistance in Neuroendovascular Therapy: Comparative Analysis of Elective and Emergency Procedures
BACKGROUND AND OBJECTIVES: Artificial intelligence (AI) has emerged as an adjunct in neuroendovascular interventions; however, its clinical utility remains insufficiently characterized. This study aimed to delineate the clinical impact of a real-time AI guidance system during neuroendovascular therapy and to compare elective and emergency interventions, using device repositioning as a quantitative indicator of procedural guidance. METHODS: A retrospective cohort of 130 neuroendovascular procedures performed utilizing an AI system (Neuro-Vascular Assist; iMed Technologies) was analyzed. The system generated automated notifications when the guidewire or guiding catheter (GC) exited the fluoroscopic field. Notifications were defined as “clinically useful” if the device exited biplane views and was repositioned within 10 seconds. The proportion of such events constituted the clinically useful notification rate. Univariate analyses compared elective and emergency procedures, and multivariate logistic regression identified independent correlates of emergency procedures. RESULTS: Emergency procedures were more frequently performed by noncertified operators ( P = .002) with fewer years of neurosurgical experience ( P = .012) under local anesthesia ( P = .010) and exhibited shorter operative durations ( P = .001). Both the absolute number ( P = .021) and rate ( P = .027) of clinically useful GC notifications were significantly higher in the emergency group, with the rate being twice that of the elective group (26% vs 13%). Multivariate analysis revealed that limited neurosurgical experience (odds ratio: 0.88; 95% CI: 0.77-1.00, P = .039) and elevated GC notification rates (odds ratio: 1.02; 95% CI: 1.00-1.03, P = .018) were associated with emergency interventions. No adverse events were considered to be attributable to the AI system. CONCLUSION: Real-time AI guidance conferred greater procedural assistance during emergency neuroendovascular procedures, typically performed by less-experienced operators. These data suggest that AI integration may augment procedural safety in high-acuity cerebrovascular settings. Prospective studies are warranted to evaluate its impact on patient-centered and workflow-efficiency outcomes.
- 13 May 2026
- Published by Wolters Kluwer Health in Neurosurgery
Real-Time Artificial Intelligence Assistance in Neuroendovascular Therapy: Comparative Analysis of Elective and Emergency Procedures
BACKGROUND AND OBJECTIVES: Artificial intelligence (AI) has emerged as an adjunct in neuroendovascular interventions; however, its clinical utility remains insufficiently characterized. This study aimed to delineate the clinical impact of a real-time AI guidance system during neuroendovascular therapy and to compare elective and emergency interventions, using device repositioning as a quantitative indicator of procedural guidance. METHODS: A retrospective cohort of 130 neuroendovascular procedures performed utilizing an AI system (Neuro-Vascular Assist; iMed Technologies) was analyzed. The system generated automated notifications when the guidewire or guiding catheter (GC) exited the fluoroscopic field. Notifications were defined as “clinically useful” if the device exited biplane views and was repositioned within 10 seconds. The proportion of such events constituted the clinically useful notification rate. Univariate analyses compared elective and emergency procedures, and multivariate logistic regression identified independent correlates of emergency procedures. RESULTS: Emergency procedures were more frequently performed by noncertified operators ( P = .002) with fewer years of neurosurgical experience ( P = .012) under local anesthesia ( P = .010) and exhibited shorter operative durations ( P = .001). Both the absolute number ( P = .021) and rate ( P = .027) of clinically useful GC notifications were significantly higher in the emergency group, with the rate being twice that of the elective group (26% vs 13%). Multivariate analysis revealed that limited neurosurgical experience (odds ratio: 0.88; 95% CI: 0.77-1.00, P = .039) and elevated GC notification rates (odds ratio: 1.02; 95% CI: 1.00-1.03, P = .018) were associated with emergency interventions. No adverse events were considered to be attributable to the AI system. CONCLUSION: Real-time AI guidance conferred greater procedural assistance during emergency neuroendovascular procedures, typically performed by less-experienced operators. These data suggest that AI integration may augment procedural safety in high-acuity cerebrovascular settings. Prospective studies are warranted to evaluate its impact on patient-centered and workflow-efficiency outcomes.
- 14 April 2026
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 36 (3) , 953-962
Initial Multicenter Evaluation of a Novel Anchoring Exchange Device: AI-based Quantitative Distal Tip-Motion Analysis
Exchange maneuvers during intracranial angioplasty and stent deployment can cause unintended distal tip motion, potentially leading to vessel injury. We evaluated a novel anchoring exchange device (Medilizer; Medikit, Tokyo, Japan), a 320-cm 0.014-inch wire with a retrievable self-expanding stent at the distal tip, designed to stabilize the distal position during exchange maneuvers and approved for clinical use in Japan. We compared exchange maneuvers using conventional wires with those using a Medilizer during angioplasty of intracranial stenosis performed at three institutions. Biplane fluoroscopic sequences (frontal and lateral views) were analyzed using an AI-assisted tracking system to quantify the trajectory length of distal tip motion in each view. Seventeen consecutive procedures (10 conventional wire cases and 7 Medilizer cases) were included. In one Medilizer case, the distal tip was outside the field of view in one projection, which was excluded from the analysis. Consequently, 20 conventional wire and 13 Medilizer views were analyzed. The trajectory length of the distal tip was significantly shorter with the Medilizer than with conventional wires (3.3 ± 1.5 mm vs. 35.9 ± 20.0 mm; p < 0.001), corresponding to an approximately 90% reduction. No adverse events occurred in any of the 17 procedures. Even in this initial cohort, the magnitude of improvement in distal tip motion strongly suggests clinically meaningful stability advantages of this anchoring exchange device. Furthermore, AI-assisted quantitative evaluation can provide an objective measure of endovascular device performance, warranting further validation studies.
- 14 April 2026
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 36 (3) , 953-962
Initial Multicenter Evaluation of a Novel Anchoring Exchange Device: AI-based Quantitative Distal Tip-Motion Analysis
Exchange maneuvers during intracranial angioplasty and stent deployment can cause unintended distal tip motion, potentially leading to vessel injury. We evaluated a novel anchoring exchange device (Medilizer; Medikit, Tokyo, Japan), a 320-cm 0.014-inch wire with a retrievable self-expanding stent at the distal tip, designed to stabilize the distal position during exchange maneuvers and approved for clinical use in Japan. We compared exchange maneuvers using conventional wires with those using a Medilizer during angioplasty of intracranial stenosis performed at three institutions. Biplane fluoroscopic sequences (frontal and lateral views) were analyzed using an AI-assisted tracking system to quantify the trajectory length of distal tip motion in each view. Seventeen consecutive procedures (10 conventional wire cases and 7 Medilizer cases) were included. In one Medilizer case, the distal tip was outside the field of view in one projection, which was excluded from the analysis. Consequently, 20 conventional wire and 13 Medilizer views were analyzed. The trajectory length of the distal tip was significantly shorter with the Medilizer than with conventional wires (3.3 ± 1.5 mm vs. 35.9 ± 20.0 mm; p < 0.001), corresponding to an approximately 90% reduction. No adverse events occurred in any of the 17 procedures. Even in this initial cohort, the magnitude of improvement in distal tip motion strongly suggests clinically meaningful stability advantages of this anchoring exchange device. Furthermore, AI-assisted quantitative evaluation can provide an objective measure of endovascular device performance, warranting further validation studies.
- Open Access
- 1 January 2026
- Published by The Japanese Society for Neuroendovascular Therapy in Journal of Neuroendovascular Therapy
- Vol. 20 (1)
Real-Time Artificial Intelligence–Based Detection of Flow-Directed Microcatheter Tip Markers
Objective: Flow-directed microcatheters (FDMs) offer high flexibility and trackability for accessing distal arterial feeders. However, the radiopaque tip marker is small, making it difficult to identify on fluoroscopy. This study evaluated an intraoperative artificial intelligence (AI)–based system for real-time detection of FDM tip markers.Methods: We retrospectively analyzed 10 consecutive cases of middle meningeal artery embolization for chronic subdural hematoma using the AI-based system. The detection rate was evaluated on a frame-by-frame basis during microcatheter placement. Exploratory subgroup analyses were performed based on the catheter diameter (1.5 Fr vs. 1.3 Fr) and whether the microcatheter tip or guidewire tip advanced ahead during navigation.Results: Twenty-five FDM placement scenes were analyzed. Mean microcatheter navigation time was 2.1 min. The precision, recall, and detection rate of the system were 95%, 51%, and 50%, respectively; the detection rate was calculated as the proportion of true-positive frames among all analyzed frames. Although this was an exploratory subgroup analysis, the detection rate appeared higher for the 1.5-Fr microcatheters than that for the 1.3-Fr microcatheters (78% vs. 46%; p = 0.006). Furthermore, the detection rate was significantly higher when the microcatheter tip advanced ahead of the guidewire tip than vice versa (65% vs. 43%; p = 0.002).Conclusion: Although the detection rate was 50%, the AI system may help operators recognize the tip position when it becomes difficult to identify on fluoroscopy. Larger multicenter studies are required to validate these findings.
- 1 January 2026
- Published by The Japanese Society for Neuroendovascular Therapy in Journal of Neuroendovascular Therapy
- Vol. 20 (1)
Open AccessReal-Time Artificial Intelligence–Based Detection of Flow-Directed Microcatheter Tip Markers
Objective: Flow-directed microcatheters (FDMs) offer high flexibility and trackability for accessing distal arterial feeders. However, the radiopaque tip marker is small, making it difficult to identify on fluoroscopy. This study evaluated an intraoperative artificial intelligence (AI)–based system for real-time detection of FDM tip markers.Methods: We retrospectively analyzed 10 consecutive cases of middle meningeal artery embolization for chronic subdural hematoma using the AI-based system. The detection rate was evaluated on a frame-by-frame basis during microcatheter placement. Exploratory subgroup analyses were performed based on the catheter diameter (1.5 Fr vs. 1.3 Fr) and whether the microcatheter tip or guidewire tip advanced ahead during navigation.Results: Twenty-five FDM placement scenes were analyzed. Mean microcatheter navigation time was 2.1 min. The precision, recall, and detection rate of the system were 95%, 51%, and 50%, respectively; the detection rate was calculated as the proportion of true-positive frames among all analyzed frames. Although this was an exploratory subgroup analysis, the detection rate appeared higher for the 1.5-Fr microcatheters than that for the 1.3-Fr microcatheters (78% vs. 46%; p = 0.006). Furthermore, the detection rate was significantly higher when the microcatheter tip advanced ahead of the guidewire tip than vice versa (65% vs. 43%; p = 0.002).Conclusion: Although the detection rate was 50%, the AI system may help operators recognize the tip position when it becomes difficult to identify on fluoroscopy. Larger multicenter studies are required to validate these findings.
- 11 November 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (3) , 894
Artificial intelligence-assisted middle meningeal artery embolization for chronic subdural hematoma with overlay visualization
The effectiveness of middle meningeal artery (MMA) embolization for chronic subdural hematoma is well established,1–3 and distal and multibranch penetration of embolic agents is recognized as a key factor for better outcomes.4 5 In recent years, several studies have described artificial intelligence (AI)-assisted neuroendovascular treatment.6–9 We recently reported that AI-assisted MMA embolization may enhance procedural safety through reflux detection and notification.10 This case (video 1) focuses on the overlay feature, highlighting its potential to improve procedural efficacy by enabling greater distal and multibranch penetration, resulting in a larger embolization volume. The overlay feature provided by the AI system enhanced visualization and notifications, enabling not only improved safety but also more effective multibranch penetration. As MMA embolization becomes more widespread, especially among younger operators, AI support that combines safety with efficacy holds promise for both clinical practice and training. Larger studies are needed to validate these findings further. Video 1 Artificial intelligence–assisted middle meningeal artery embolization with overlay visualization promoting distal and multibranch penetration.:
- 11 November 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (3) , 894
Artificial intelligence-assisted middle meningeal artery embolization for chronic subdural hematoma with overlay visualization
The effectiveness of middle meningeal artery (MMA) embolization for chronic subdural hematoma is well established,1–3 and distal and multibranch penetration of embolic agents is recognized as a key factor for better outcomes.4 5 In recent years, several studies have described artificial intelligence (AI)-assisted neuroendovascular treatment.6–9 We recently reported that AI-assisted MMA embolization may enhance procedural safety through reflux detection and notification.10 This case (video 1) focuses on the overlay feature, highlighting its potential to improve procedural efficacy by enabling greater distal and multibranch penetration, resulting in a larger embolization volume. The overlay feature provided by the AI system enhanced visualization and notifications, enabling not only improved safety but also more effective multibranch penetration. As MMA embolization becomes more widespread, especially among younger operators, AI support that combines safety with efficacy holds promise for both clinical practice and training. Larger studies are needed to validate these findings further. Video 1 Artificial intelligence–assisted middle meningeal artery embolization with overlay visualization promoting distal and multibranch penetration.:
- 9 October 2025
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 99 (1) , 107-112
Real-Time Artificial Intelligence–Assisted Middle Meningeal Artery Embolization Using Liquid Embolic Agents for Chronic Subdural Hematoma: A Preliminary Experience
BACKGROUND AND OBJECTIVES: Middle meningeal artery (MMA) embolization is an emerging treatment option for chronic subdural hematoma. Surgeons must pay close attention to multiple vessels when using liquid embolic agents to avoid complications. Unintended embolization through dangerous anastomotic connections can result in serious complications, such as visual loss or cranial nerve dysfunction. In this study, we report our preliminary experience with real-time artificial intelligence (AI)–assisted MMA embolization and evaluate its performance. METHODS: An AI-based system (iMed Technologies) was used for 19 lesions in 15 patients at 2 institutions, with 4 patients receiving bilateral treatment. The software automatically detects liquid embolic agents in biplane fluoroscopy images in real-time and notifies operators when the agent reaches any of the predefined areas. The safety, efficacy, and accuracy of the notifications were retrospectively evaluated using recorded videos. RESULTS: A total of 36 MMA branches were embolized using n-Butyl-2-cyanoacrylate. The mean true positives, false negatives, and false-positive notifications per vessel embolization were 8.9, 1.6, and 0.9, respectively. The precision and recall of the notifications were 90.9% and 84.9%, respectively. In 40.2% of the true-positive notifications, operators immediately paused agent injection after receiving the notification, demonstrating potential clinical effectiveness of the AI system. No adverse events were reported. CONCLUSION: To our knowledge, this is the first study to examine MMA embolization for chronic subdural hematoma with real-time AI assistance. The system demonstrated high notification accuracy, safety, and potential clinical usefulness for liquid embolization procedures. Large-scale prospective studies are warranted to validate the impact on clinical outcomes.
- 9 October 2025
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 99 (1) , 107-112
Real-Time Artificial Intelligence–Assisted Middle Meningeal Artery Embolization Using Liquid Embolic Agents for Chronic Subdural Hematoma: A Preliminary Experience
BACKGROUND AND OBJECTIVES: Middle meningeal artery (MMA) embolization is an emerging treatment option for chronic subdural hematoma. Surgeons must pay close attention to multiple vessels when using liquid embolic agents to avoid complications. Unintended embolization through dangerous anastomotic connections can result in serious complications, such as visual loss or cranial nerve dysfunction. In this study, we report our preliminary experience with real-time artificial intelligence (AI)–assisted MMA embolization and evaluate its performance. METHODS: An AI-based system (iMed Technologies) was used for 19 lesions in 15 patients at 2 institutions, with 4 patients receiving bilateral treatment. The software automatically detects liquid embolic agents in biplane fluoroscopy images in real-time and notifies operators when the agent reaches any of the predefined areas. The safety, efficacy, and accuracy of the notifications were retrospectively evaluated using recorded videos. RESULTS: A total of 36 MMA branches were embolized using n-Butyl-2-cyanoacrylate. The mean true positives, false negatives, and false-positive notifications per vessel embolization were 8.9, 1.6, and 0.9, respectively. The precision and recall of the notifications were 90.9% and 84.9%, respectively. In 40.2% of the true-positive notifications, operators immediately paused agent injection after receiving the notification, demonstrating potential clinical effectiveness of the AI system. No adverse events were reported. CONCLUSION: To our knowledge, this is the first study to examine MMA embolization for chronic subdural hematoma with real-time AI assistance. The system demonstrated high notification accuracy, safety, and potential clinical usefulness for liquid embolization procedures. Large-scale prospective studies are warranted to validate the impact on clinical outcomes.
- 17 February 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (8) , 1647-1651
World’s First Real-Time Artificial Intelligence–Assisted Mechanical Thrombectomy for Acute Ischemic Stroke
Several recent reports have discussed real-time artificial intelligence (AI) assistance in elective neuroendovascular procedures such as carotid artery stenting, coil embolization for cerebral aneurysms, and liquid embolization. We present our preliminary experience with real-time AI-assisted mechanical thrombectomy (MT) for acute ischemic stroke (AIS) under local anesthesia. A real-time deep learning-based AI software (Neuro-Vascular Assist, iMed technologies, Tokyo, Japan) was used during MT for 16 consecutive patients with AIS. The AI system provided real-time notifications when the guiding catheter (GC) moved out of the fluoroscopic image. The efficacy, accuracy, and safety of the notifications were evaluated using video recordings. The AI system functioned properly in all cases. The mean number of notifications per case for the GC moving out of view was 8.1. The overall precision and recall of AI notifications were 97% and 99%, respectively. Of the 126 true-positive AI notifications, 25 (20%) prompted operators to reposition the GC within 10 s when it became unobservable in both frontal and lateral imaging planes. This response indicates the potential effectiveness of the AI system. No adverse events or delays in procedures due to the AI system occurred. In this preliminary study, the software was sufficiently accurate and safe for MT procedures, suggesting its usefulness. To the best of our knowledge, this is one of the first studies to report using a real-time AI system for MT in patients with AIS as an emergent procedure. Large-scale studies are warranted to validate its impact on procedural workflow and clinical outcomes. ABBREVIATIONS: AI = artificial Intelligence; MT = mechanical thrombectomy; AIS = acute ischemic stroke; GC = guiding catheter; TP = true positive; FP = false positive; FN = false negative; CAS = carotid artery stenting.
- 17 February 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (8) , 1647-1651
World’s First Real-Time Artificial Intelligence–Assisted Mechanical Thrombectomy for Acute Ischemic Stroke
Several recent reports have discussed real-time artificial intelligence (AI) assistance in elective neuroendovascular procedures such as carotid artery stenting, coil embolization for cerebral aneurysms, and liquid embolization. We present our preliminary experience with real-time AI-assisted mechanical thrombectomy (MT) for acute ischemic stroke (AIS) under local anesthesia. A real-time deep learning-based AI software (Neuro-Vascular Assist, iMed technologies, Tokyo, Japan) was used during MT for 16 consecutive patients with AIS. The AI system provided real-time notifications when the guiding catheter (GC) moved out of the fluoroscopic image. The efficacy, accuracy, and safety of the notifications were evaluated using video recordings. The AI system functioned properly in all cases. The mean number of notifications per case for the GC moving out of view was 8.1. The overall precision and recall of AI notifications were 97% and 99%, respectively. Of the 126 true-positive AI notifications, 25 (20%) prompted operators to reposition the GC within 10 s when it became unobservable in both frontal and lateral imaging planes. This response indicates the potential effectiveness of the AI system. No adverse events or delays in procedures due to the AI system occurred. In this preliminary study, the software was sufficiently accurate and safe for MT procedures, suggesting its usefulness. To the best of our knowledge, this is one of the first studies to report using a real-time AI system for MT in patients with AIS as an emergent procedure. Large-scale studies are warranted to validate its impact on procedural workflow and clinical outcomes. ABBREVIATIONS: AI = artificial Intelligence; MT = mechanical thrombectomy; AIS = acute ischemic stroke; GC = guiding catheter; TP = true positive; FP = false positive; FN = false negative; CAS = carotid artery stenting.