Shinichi Iwakoshi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Shinichi Iwakoshi has a total of 159 co-authors. Here are the top co-authors by number of shared publications:
Kimihiko Kichikawa
Department of Diagnostic and Interventional Radiology, Nara Medical University
18 shared publicationsShigeo Ichihashi
Department of Radiology, Nara Medical University, Kashihara, Japan
12 shared publications- Shigeo Ichihashi
Department of Diagnostic and Interventional Radiology, Nara Medical University, Nara, Japan
11 shared publications Shoji Sakaguchi
Department of Radiology, Matsubara Tokusyukai Hospital
9 shared publicationsToshihiro Tanaka
Department of Radiology, Nara Medical University, Kashihara, Japan
8 shared publicationsTakahiro Nakai
Department of Radiology, Nara Medical University, Kashihara, Japan
7 shared publications
Latest Publications
- Open Access
- 30 October 2026
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1) , 139
Clinical outcomes and midterm durability of the preloading coil-in-plug technique in various arterial territories
Background: Conventional coil embolization of large or high-flow arteries may require multiple coils and a long embolization segment. The Amplatzer Vascular Plug (AVP) enables controlled deployment and repositioning; however, complete occlusion partly depends on thrombus formation, and residual flow or recanalization may occur. The preloading coil-in-plug (P-CIP) technique combines the positional stability of an AVP with internal coil packing. This study evaluated its technical feasibility, procedural characteristics, safety, and mid-term imaging outcomes across different arterial territories. Methods: This retrospective single-center study evaluated consecutive patients who underwent P-CIP embolization between April 2018 and April 2026. Before insertion, a microcatheter was passed through the nitinol mesh into the internal space of an AVP I outside the patient. The plug and microcatheter were advanced together and deployed at the target site before plug detachment. Coils were then packed within the expanded plug through the preloaded microcatheter. Technical success, AVP-to-vessel diameter ratio, coil use, coil-packing time, procedure-related complications, target-vessel recanalization, and reintervention were evaluated. Imaging follow-up was based on contrast-enhanced computed tomography. Results: The study included 34 patients, of whom 21 were men, with 40 embolized vessels. The target vessels were the celiac artery in 6 procedures, internal iliac artery in 25, superior or inferior gluteal artery in 8, and external iliac artery in 1. Technical success and final angiographic occlusion were achieved in all 40 vessels. The mean AVP-to-vessel diameter ratio was 1.44, corresponding to 44% oversizing. The mean number of coils used per AVP was 3.13, and the mean coil-packing time was 10.7 min. During a mean imaging follow-up of 619 days, no procedure-related complications, target-vessel recanalization, device migration, or reintervention occurred. Ten patients died during follow-up, but none of the deaths was related to embolization. Conclusions: P-CIP embolization was technically feasible across multiple arterial territories and achieved sustained target-vessel occlusion during mid-term imaging follow-up. The technique may be useful when controlled short-segment embolization is required. Comparative studies are needed to determine whether P-CIP provides advantages over conventional coil embolization or AVP placement alone.
- 30 October 2026
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1) , 139
Open AccessClinical outcomes and midterm durability of the preloading coil-in-plug technique in various arterial territories
Background: Conventional coil embolization of large or high-flow arteries may require multiple coils and a long embolization segment. The Amplatzer Vascular Plug (AVP) enables controlled deployment and repositioning; however, complete occlusion partly depends on thrombus formation, and residual flow or recanalization may occur. The preloading coil-in-plug (P-CIP) technique combines the positional stability of an AVP with internal coil packing. This study evaluated its technical feasibility, procedural characteristics, safety, and mid-term imaging outcomes across different arterial territories. Methods: This retrospective single-center study evaluated consecutive patients who underwent P-CIP embolization between April 2018 and April 2026. Before insertion, a microcatheter was passed through the nitinol mesh into the internal space of an AVP I outside the patient. The plug and microcatheter were advanced together and deployed at the target site before plug detachment. Coils were then packed within the expanded plug through the preloaded microcatheter. Technical success, AVP-to-vessel diameter ratio, coil use, coil-packing time, procedure-related complications, target-vessel recanalization, and reintervention were evaluated. Imaging follow-up was based on contrast-enhanced computed tomography. Results: The study included 34 patients, of whom 21 were men, with 40 embolized vessels. The target vessels were the celiac artery in 6 procedures, internal iliac artery in 25, superior or inferior gluteal artery in 8, and external iliac artery in 1. Technical success and final angiographic occlusion were achieved in all 40 vessels. The mean AVP-to-vessel diameter ratio was 1.44, corresponding to 44% oversizing. The mean number of coils used per AVP was 3.13, and the mean coil-packing time was 10.7 min. During a mean imaging follow-up of 619 days, no procedure-related complications, target-vessel recanalization, device migration, or reintervention occurred. Ten patients died during follow-up, but none of the deaths was related to embolization. Conclusions: P-CIP embolization was technically feasible across multiple arterial territories and achieved sustained target-vessel occlusion during mid-term imaging follow-up. The technique may be useful when controlled short-segment embolization is required. Comparative studies are needed to determine whether P-CIP provides advantages over conventional coil embolization or AVP placement alone.
- 17 April 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (10) , 1-3
Arterial Perfusion Changes Following Transcatheter Arterial Microembolization for Hand Joint Pain
- 17 April 2026
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 49 (10) , 1-3
Arterial Perfusion Changes Following Transcatheter Arterial Microembolization for Hand Joint Pain
- 23 November 2024
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 111, 225-230
Physician-Modified Fenestrated Endovascular Aortic Repair for the Preservation of Hypogastric Artery Perfusion and Efficacy of Hydrogel Coil Fenestration Reinforcement
- 23 November 2024
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 111, 225-230
Physician-Modified Fenestrated Endovascular Aortic Repair for the Preservation of Hypogastric Artery Perfusion and Efficacy of Hydrogel Coil Fenestration Reinforcement
- Open Access
- 1 July 2024
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 9 (2) , 49-54
Efficacy of the Stripped AFX Aortic Cuff as a Scaffolding Bare Stent to Facilitate the Expansion of the Thoracoabdominal and Visceral Aorta during Thoracic Endovascular Aortic Repair for Complicated Stanford Type B Aortic Dissection
Purpose: During thoracic endovascular aortic repair for complicated Stanford type B aortic dissection, large bare stent placement for the abdominal aorta is sometimes necessary. In smaller abdominal aortic diameter cases, we used the stripped AFX aortic cuff as a scaffolding bare stent rather than the Zenith Dissection Endovascular Stent, which is a commercially available, large bare stent. In this study, we evaluated the feasibility of the stripped AFX aortic cuff and experiments were conducted to compare the stripped AFX and the Zenith Dissection Endovascular Stent.Material and Method: The type B aortic dissection patients treated with thoracic endovascular aortic repair using stripped AFX at three institutions between January 2014 and December 2017 were retrospectively reviewed. Clinical data, including technical success, perioperative complication, and overall survival, were evaluated. The experiment assessed the chronic outward force that reflected the load acting on the artery wall from the stent.Result: Eight cases (seven males) were reviewed. The median (interquartile range, IQR) age of the patients was 60 years (46.3-70.3). The technical success rate was 100%, and no perioperative complications were observed. The median (IQR) follow-up period was 28.9 months (17.5-31.5). During the follow-up, one patient died of septic shock unrelated to aortic events. The median (IQR) diameter of the stripped AFX on the last follow-up CT was 23.5 mm (21.9-25.0). The chronic outward force of the Zenith Dissection Endovascular Stent was two to three times that of the stripped AFX.Conclusions: The stripped AFX aortic cuff is feasible and safe as a scaffolding stent during thoracic endovascular aortic repair for Stanford Type B aortic dissection.
- 1 July 2024
- Published by The Japanese Society of Interventional Radiology in Interventional Radiology
- Vol. 9 (2) , 49-54
Open AccessEfficacy of the Stripped AFX Aortic Cuff as a Scaffolding Bare Stent to Facilitate the Expansion of the Thoracoabdominal and Visceral Aorta during Thoracic Endovascular Aortic Repair for Complicated Stanford Type B Aortic Dissection
Purpose: During thoracic endovascular aortic repair for complicated Stanford type B aortic dissection, large bare stent placement for the abdominal aorta is sometimes necessary. In smaller abdominal aortic diameter cases, we used the stripped AFX aortic cuff as a scaffolding bare stent rather than the Zenith Dissection Endovascular Stent, which is a commercially available, large bare stent. In this study, we evaluated the feasibility of the stripped AFX aortic cuff and experiments were conducted to compare the stripped AFX and the Zenith Dissection Endovascular Stent.Material and Method: The type B aortic dissection patients treated with thoracic endovascular aortic repair using stripped AFX at three institutions between January 2014 and December 2017 were retrospectively reviewed. Clinical data, including technical success, perioperative complication, and overall survival, were evaluated. The experiment assessed the chronic outward force that reflected the load acting on the artery wall from the stent.Result: Eight cases (seven males) were reviewed. The median (interquartile range, IQR) age of the patients was 60 years (46.3-70.3). The technical success rate was 100%, and no perioperative complications were observed. The median (IQR) follow-up period was 28.9 months (17.5-31.5). During the follow-up, one patient died of septic shock unrelated to aortic events. The median (IQR) diameter of the stripped AFX on the last follow-up CT was 23.5 mm (21.9-25.0). The chronic outward force of the Zenith Dissection Endovascular Stent was two to three times that of the stripped AFX.Conclusions: The stripped AFX aortic cuff is feasible and safe as a scaffolding stent during thoracic endovascular aortic repair for Stanford Type B aortic dissection.
- Open Access
- 14 March 2024
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 10 (3) , 101484
Jaw claudication and branch perfusion reduction as rare complications of fenestrated thoracic endovascular aortic repair
- 14 March 2024
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 10 (3) , 101484
Open AccessJaw claudication and branch perfusion reduction as rare complications of fenestrated thoracic endovascular aortic repair
- 10 January 2023
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 65 (1) , e10-e11
Outcomes of embolization procedures for type II endoleaks following endovascular abdominal aortic repair
- 10 January 2023
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 65 (1) , e10-e11
Outcomes of embolization procedures for type II endoleaks following endovascular abdominal aortic repair
- 18 November 2022
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 76 (6) , 1755
Drug Eluting Versus Covered Stent for Femoropopliteal Artery Lesions: Results of the ULTIMATE Study
- 18 November 2022
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 76 (6) , 1755
Drug Eluting Versus Covered Stent for Femoropopliteal Artery Lesions: Results of the ULTIMATE Study
- 17 August 2022
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 77 (1) , 114-121.e2
Outcomes of embolization procedures for type II endoleaks following endovascular abdominal aortic repair
- 17 August 2022
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 77 (1) , 114-121.e2
Outcomes of embolization procedures for type II endoleaks following endovascular abdominal aortic repair