Michael Poole
Research Subjects
Michael Poole has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Stuart Crozier
School of Information Technology and Electrical Engineering Faculty of Engineering Architecture and Information Technology University of Queensland St. Lucia, Brisbane Queensland Australia
11 shared publications- Hector Sanchez Lopez
Florida Atlantic University,Boca Raton,FL,U.S.,33431
9 shared publications - Feng Liu
University of Queensland
4 shared publications Hidenao Fukuyama
Graduate School of Medicine, Kyoto University, Kyoto , Japan
3 shared publicationsHitoshi Kitaguchi
National Institute for Materials Science, Tsukuba, Japan
3 shared publicationsIwao Nakajima
Takashima Seisakusho Company, Ltd., Tokyo, Japan
3 shared publications
Latest Publications
- 26 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 50 (2) , 945-948
Modal Analysis of Currents Induced by Magnetic Resonance Imaging Gradient Coils
In magnetic resonance imaging (MRI), gradient coils are switched during fast current pulse sequences. These time-varying fields interact with the conducting structures of the scanner, producing deleterious effects such as image distortions and Joule heating. Using a multi-layer integral method, the spatiotemporal nature of the eddy currents induced by the gradient coils is investigated. The existence of the eigenmode is experimentally demonstrated by measuring the magnetic field and the time decay constant of a typical unshielded z-gradient coil and its interaction with a conductive cylinder. An effective current tailoring is achieved using the characteristic eigenvalues of the conducting domain-exciting coil system. The method can be used to understand and mitigate undesired effects of eddy currents in MRI.
- 26 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 50 (2) , 945-948
Modal Analysis of Currents Induced by Magnetic Resonance Imaging Gradient Coils
In magnetic resonance imaging (MRI), gradient coils are switched during fast current pulse sequences. These time-varying fields interact with the conducting structures of the scanner, producing deleterious effects such as image distortions and Joule heating. Using a multi-layer integral method, the spatiotemporal nature of the eddy currents induced by the gradient coils is investigated. The existence of the eigenmode is experimentally demonstrated by measuring the magnetic field and the time decay constant of a typical unshielded z-gradient coil and its interaction with a conductive cylinder. An effective current tailoring is achieved using the characteristic eigenvalues of the conducting domain-exciting coil system. The method can be used to understand and mitigate undesired effects of eddy currents in MRI.
- 1 October 2013
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 235, 85-94
Theoretical design of gradient coils with minimum power dissipation: Accounting for the discretization of current density into coil windings
- 1 October 2013
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 235, 85-94
Theoretical design of gradient coils with minimum power dissipation: Accounting for the discretization of current density into coil windings
- 11 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 4400904
Newly Designed 3 T MRI Magnet Wound With Bi-2223 Tape Conductors
We have designed and fabricated a 3T magnetic resonance imaging magnet system for the human brain, which was wound with Bi-2223 tape conductors. Cooled by a Gifford-McMahon cryocooler, it was operated at 20 K with a stored energy of 2.3 MJ. A magnetic-field homogeneity of 5 ppm was attained at 1.5 T, which was our target value. Using this Bi-2223 high-temperature superconducting magnet, we obtained magnetic resonance images in 1.5 T at 8.5 K. The system was successfully magnetized to 3 T, which is the final target field in our project. This work demonstrates the potential of the high-temperature superconducting magnet for use in human magnetic resonance imaging experiments.
- 11 January 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 4400904
Newly Designed 3 T MRI Magnet Wound With Bi-2223 Tape Conductors
We have designed and fabricated a 3T magnetic resonance imaging magnet system for the human brain, which was wound with Bi-2223 tape conductors. Cooled by a Gifford-McMahon cryocooler, it was operated at 20 K with a stored energy of 2.3 MJ. A magnetic-field homogeneity of 5 ppm was attained at 1.5 T, which was our target value. Using this Bi-2223 high-temperature superconducting magnet, we obtained magnetic resonance images in 1.5 T at 8.5 K. The system was successfully magnetized to 3 T, which is the final target field in our project. This work demonstrates the potential of the high-temperature superconducting magnet for use in human magnetic resonance imaging experiments.
- Open Access
- 5 October 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (2) , 584-594
Minimum maximum temperature gradient coil design
Ohmic heating is a serious problem in gradient coil operation. A method is presented for redesigning cylindrical gradient coils to operate at minimum peak temperature, while maintaining field homogeneity and coil performance. To generate these minimaxT coil windings, an existing analytic method for simulating the spatial temperature distribution of single layer gradient coils is combined with a minimax optimization routine based on sequential quadratic programming. Simulations are provided for symmetric and asymmetric gradient coils that show considerable improvements in reducing maximum temperature over existing methods. The winding patterns of the minimaxT coils were found to be heavily dependent on the assumed thermal material properties and generally display an interesting “fish-eye” spreading of windings in the dense regions of the coil. Small prototype coils were constructed and tested for experimental validation and these demonstrate that with a reasonable estimate of material properties, thermal performance can be improved considerably with negligible change to the field error or standard figures of merit. Magn Reson Med 70:584–594, 2013.
- 5 October 2012
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 70 (2) , 584-594
Open AccessMinimum maximum temperature gradient coil design
Ohmic heating is a serious problem in gradient coil operation. A method is presented for redesigning cylindrical gradient coils to operate at minimum peak temperature, while maintaining field homogeneity and coil performance. To generate these minimaxT coil windings, an existing analytic method for simulating the spatial temperature distribution of single layer gradient coils is combined with a minimax optimization routine based on sequential quadratic programming. Simulations are provided for symmetric and asymmetric gradient coils that show considerable improvements in reducing maximum temperature over existing methods. The winding patterns of the minimaxT coils were found to be heavily dependent on the assumed thermal material properties and generally display an interesting “fish-eye” spreading of windings in the dense regions of the coil. Small prototype coils were constructed and tested for experimental validation and these demonstrate that with a reasonable estimate of material properties, thermal performance can be improved considerably with negligible change to the field error or standard figures of merit. Magn Reson Med 70:584–594, 2013.
- 1 September 2012
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 222, 8-15
Simulation and analysis of the interactions between split gradient coils and a split magnet cryostat in an MRI–PET system
- 1 September 2012
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 222, 8-15
Simulation and analysis of the interactions between split gradient coils and a split magnet cryostat in an MRI–PET system
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 376-381
Cryogen-free 3T-MRI system for human brain research using B-2223 high-temperature superconducting tapes
The demand for the exhaustible natural resource helium is increasing rapidly, with 20% of global production used as the cryogen in superconducting MRI magnets. High-temperature superconducting (HTS) materials show great potential for realizing helium-less magnets. Here, we report a cryogen-free 3T-MRI scanner for human brain research using Bi-2223 tapes operating at a temperature of 20K.
- 1 July 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 376-381
Cryogen-free 3T-MRI system for human brain research using B-2223 high-temperature superconducting tapes
The demand for the exhaustible natural resource helium is increasing rapidly, with 20% of global production used as the cryogen in superconducting MRI magnets. High-temperature superconducting (HTS) materials show great potential for realizing helium-less magnets. Here, we report a cryogen-free 3T-MRI scanner for human brain research using Bi-2223 tapes operating at a temperature of 20K.
- 28 December 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (2) , 639-648
Minimax current density gradient coils: Analysis of coil performance and heating
Standard gradient coils are designed by minimizing the inductance or resistance for an acceptable level of gradient field nonlinearity. Recently, a new method was proposed to minimize the maximum value of the current density in a coil additionally. The stated aim of that method was to increase the minimum wire spacing and to reduce the peak temperature in a coil for fixed efficiency. These claims are tested in this study with experimental measurements of magnetic field and temperature as well as simulations of the performance of many coils. Experimental results show a 90% increase in minimum wire spacing and 40% reduction in peak temperature for equal coil efficiency and field linearity. Simulations of many more coils indicate increase in minimum wire spacing of between 50 and 340% for the coils studied here. This method is shown to be able to increase coil efficiency when constrained by minimum wire spacing rather than switching times or total power dissipation. This increase in efficiency could be used to increase gradient strength, duty cycle, or buildability.
- 28 December 2011
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (2) , 639-648
Minimax current density gradient coils: Analysis of coil performance and heating
Standard gradient coils are designed by minimizing the inductance or resistance for an acceptable level of gradient field nonlinearity. Recently, a new method was proposed to minimize the maximum value of the current density in a coil additionally. The stated aim of that method was to increase the minimum wire spacing and to reduce the peak temperature in a coil for fixed efficiency. These claims are tested in this study with experimental measurements of magnetic field and temperature as well as simulations of the performance of many coils. Experimental results show a 90% increase in minimum wire spacing and 40% reduction in peak temperature for equal coil efficiency and field linearity. Simulations of many more coils indicate increase in minimum wire spacing of between 50 and 340% for the coils studied here. This method is shown to be able to increase coil efficiency when constrained by minimum wire spacing rather than switching times or total power dissipation. This increase in efficiency could be used to increase gradient strength, duty cycle, or buildability.
- 15 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 48 (6) , 1967-1975
Gradient-Coil Design: A Multi-Objective Problem
In this work, the design of gradient coils for magnetic resonance imaging (MRI) is studied as a multi-objective optimization (MOP) problem, which is successfully solved by using Pareto optimality formalism. The proposed approach is illustrated using a stream function inverse boundary element method (IBEM), as the coil design paradigm that is capable of including numerous design requirements or objectives. These are frequently in conflict, which stresses the need to deal efficiently with the tradeoff between different coil properties. It is shown that the inclusion of many of the most commonly used coil design requirements (such as field homogeneity, uniformity, magnetic stored energy, power dissipated, torque balanced ... ) reduces the problem to a convex MOP, where Pareto optimal solutions can be efficiently found by using suitable convex optimization procedures. Pertinent examples are studied to illustrate the versatility of the proposed MOP approach, which can be used to obtain a comprehensive understanding of the coil design problem, as well as to handle the different coil requirements efficiently and how they should be combined to yield the best solution for a given problem.
- 15 December 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 48 (6) , 1967-1975
Gradient-Coil Design: A Multi-Objective Problem
In this work, the design of gradient coils for magnetic resonance imaging (MRI) is studied as a multi-objective optimization (MOP) problem, which is successfully solved by using Pareto optimality formalism. The proposed approach is illustrated using a stream function inverse boundary element method (IBEM), as the coil design paradigm that is capable of including numerous design requirements or objectives. These are frequently in conflict, which stresses the need to deal efficiently with the tradeoff between different coil properties. It is shown that the inclusion of many of the most commonly used coil design requirements (such as field homogeneity, uniformity, magnetic stored energy, power dissipated, torque balanced ... ) reduces the problem to a convex MOP, where Pareto optimal solutions can be efficiently found by using suitable convex optimization procedures. Pertinent examples are studied to illustrate the versatility of the proposed MOP approach, which can be used to obtain a comprehensive understanding of the coil design problem, as well as to handle the different coil requirements efficiently and how they should be combined to yield the best solution for a given problem.
- 24 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (6) , 3592-3598
Simulation of Gradient-Coil-Induced Eddy Currents and Their Effects on a Head-Only HTS MRI Magnet
In this paper, we simulate the effects of eddy currents induced by switched gradient coils in the cylindrical cryostat structures of a high-temperature superconducting (HTS) magnetic resonance imaging magnet. A novel network method was used with spectral decomposition of the current density in the φ- and z-directions to simulate the effects of X-gradient coils. Two types of active magnetic shielding were simulated, and it was found that one type is able to reduce the power of the eddy currents in the cryostat to a greater extent than the other. These results will inform the design of gradient coils that protect the HTS magnet from eddy-current-induced heating and vibrations.
- 24 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (6) , 3592-3598
Simulation of Gradient-Coil-Induced Eddy Currents and Their Effects on a Head-Only HTS MRI Magnet
In this paper, we simulate the effects of eddy currents induced by switched gradient coils in the cylindrical cryostat structures of a high-temperature superconducting (HTS) magnetic resonance imaging magnet. A novel network method was used with spectral decomposition of the current density in the φ- and z-directions to simulate the effects of X-gradient coils. Two types of active magnetic shielding were simulated, and it was found that one type is able to reduce the power of the eddy currents in the cryostat to a greater extent than the other. These results will inform the design of gradient coils that protect the HTS magnet from eddy-current-induced heating and vibrations.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 4149-4152
Simulation and analysis of split gradient coil performance in MRI
Split magnet systems for hybrid imaging, such as positron emission tomography-magnetic resonance imaging (PET-MRI) and Radiotherapy-MRI, require gradient coils designed with similar shapes as their corresponding main magnet. This introduces challenges in the gradient coil design of good performance and manufacturing. In this paper the effect of the gap size in shielded transverse split gradient coils and split cryostat “warm” bore over the coil efficiency, shielding efficiency, wire spacing, cryostat ohmic power loss and mechanical vibration have been simulated and studied. A “free-surface” gradient coil design method was used to design the split, actively-shielded transverse gradient coils with an axial gap. A network method was used to calculate the eddy currents induced in the split cryostat “warm” bore. The shielding efficiency and the minimum wire spacing were found to decrease when the size of the central gap is increased. The ohmic power loss and the amplitude of the radial vibrations in the split cryostat “warm” bore increases when the gap size in the gradient coil and “warm” bore is increased. It is hoped that these investigations will be useful for the development of new hybrid imaging modalities involving MRI.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2011 (1094687X) , 4149-4152
Simulation and analysis of split gradient coil performance in MRI
Split magnet systems for hybrid imaging, such as positron emission tomography-magnetic resonance imaging (PET-MRI) and Radiotherapy-MRI, require gradient coils designed with similar shapes as their corresponding main magnet. This introduces challenges in the gradient coil design of good performance and manufacturing. In this paper the effect of the gap size in shielded transverse split gradient coils and split cryostat “warm” bore over the coil efficiency, shielding efficiency, wire spacing, cryostat ohmic power loss and mechanical vibration have been simulated and studied. A “free-surface” gradient coil design method was used to design the split, actively-shielded transverse gradient coils with an axial gap. A network method was used to calculate the eddy currents induced in the split cryostat “warm” bore. The shielding efficiency and the minimum wire spacing were found to decrease when the size of the central gap is increased. The ohmic power loss and the amplitude of the radial vibrations in the split cryostat “warm” bore increases when the gap size in the gradient coil and “warm” bore is increased. It is hoped that these investigations will be useful for the development of new hybrid imaging modalities involving MRI.