Bing Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bing Song has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Hongbo Shi
Key Laboratory of Smart Manufacturing in Energy Chemical Process of the Ministry of Education East China University of Science and Technology Shanghai China
35 shared publications - Yang Tao
Key Laboratory of Smart Manufacturing in Energy Chemical Process of the Ministry of Education East China University of Science and Technology Shanghai China
28 shared publications - Shuai Tan
Key Laboratory of Smart Manufacturing in Energy Chemical Process, Ministry of Education, East China University of Science and Technology, Shanghai, China
22 shared publications Yang Tao
4 shared publications- Boyu Wang
Department of Computer Science, Western University, London, ON, Canada
3 shared publications Hongbo Shi
3 shared publications
Latest Publications
- Open Access
The State Monitoring of Energy Storage Power Stations Based on the Dynamic Local Preserving Projection–Local Outlier Factor Method
Monitoring the operating status of energy storage power stations can detect battery faults in enough time to prevent them from evolving into serious accidents capable of causing economic losses or even casualties. In this paper, a novel data-driven operating status monitoring method named dynamic local preserving projection–local outlier factor (DLPP-LOF) is proposed to improve the system safety performance of energy storage power stations. First, considering that the data collected by the battery management system of the energy storage power station have temporal correlations, the collected data are augmented so that the constructed augmentation matrix can effectively contain the autocorrelation in the data. Then, based on the local preserving projection (LPP) method, manifold features are effectively extracted from the augmented data matrix to preserve the meaningful local structure. Because the data in the battery management system of the energy storage power station do not display any specific distribution, it is not possible to perform traditional T2 and SPE statistical analysis. Therefore, we propose the use of the local outlier factor (LOF) method to obtain statistics from monitoring for early warning relating to fault status. Finally, the effectiveness and superiority of the proposed DLPP-LOF method are illustrated by applying it to a practical energy storage power station and comparing the results with those of classical methods.
Open AccessThe State Monitoring of Energy Storage Power Stations Based on the Dynamic Local Preserving Projection–Local Outlier Factor Method
Monitoring the operating status of energy storage power stations can detect battery faults in enough time to prevent them from evolving into serious accidents capable of causing economic losses or even casualties. In this paper, a novel data-driven operating status monitoring method named dynamic local preserving projection–local outlier factor (DLPP-LOF) is proposed to improve the system safety performance of energy storage power stations. First, considering that the data collected by the battery management system of the energy storage power station have temporal correlations, the collected data are augmented so that the constructed augmentation matrix can effectively contain the autocorrelation in the data. Then, based on the local preserving projection (LPP) method, manifold features are effectively extracted from the augmented data matrix to preserve the meaningful local structure. Because the data in the battery management system of the energy storage power station do not display any specific distribution, it is not possible to perform traditional T2 and SPE statistical analysis. Therefore, we propose the use of the local outlier factor (LOF) method to obtain statistics from monitoring for early warning relating to fault status. Finally, the effectiveness and superiority of the proposed DLPP-LOF method are illustrated by applying it to a practical energy storage power station and comparing the results with those of classical methods.
- 11 September 2026
- Published by Elsevier in Journal of Process Control
- Vol. 167
A multi-information dynamic fitting weighted strategy based on process knowledge for quality-driven process monitoring
- 11 September 2026
- Published by Elsevier in Journal of Process Control
- Vol. 167
A multi-information dynamic fitting weighted strategy based on process knowledge for quality-driven process monitoring
- 3 September 2026
- Published by Elsevier in Journal of Process Control
- Vol. 167
Few-shot class-incremental fault diagnosis via orthogonal prototypes and fuzzy uncertainty modeling
- 3 September 2026
- Published by Elsevier in Journal of Process Control
- Vol. 167
Few-shot class-incremental fault diagnosis via orthogonal prototypes and fuzzy uncertainty modeling
- 1 September 2026
- Published by Wiley in The Canadian Journal of Chemical Engineering
Causal‐oriented kernel regularized canonical variate analysis for incipient fault detection in large‐scale processes
To address the problem of balancing sensitivity and robustness in incipient fault detection (IFD) for large‐scale processes, a distributed monitoring framework based on causal‐oriented kernel regularized canonical variate analysis (CO‐KRCVA) is proposed. The framework divides operational units into sub‐blocks according to the sequence of production. To reveal the information transfer relationships and the underlying mechanisms of dynamic changes among variables, a causal difference matrix (CDM) using transfer entropy estimation is constructed for each sub‐block. Based on this, a CO‐KRCVA model is established, which specifically captures targeted minor variations of process variables to enhance the sensitivity and reliability. Its regularization strategy further overcomes the effects of random noise or interference to reduce false alarms. In addition, the Wasserstein distance (WD)‐based statistic is employed to sensitively reflect distribution shifts from both probabilistic and geometric perspectives. To facilitate global detection, Bayesian inference is used to fuse the results from local models. Finally, the proposed method and monitoring framework are validated for effectiveness on different types of faults in the vinyl acetate monomer (VAM) process and Tennessee Eastman (TE) process. Experimental results show that compared with CVA, the proposed method improves the early fault detection rate by 28.47%, 46.21%, and 12.6%, respectively, for the three fault types in the TE process, while reducing the false alarm rate by 0.52%, 1.44%, and 1.36%.
- 1 September 2026
- Published by Wiley in The Canadian Journal of Chemical Engineering
Causal‐oriented kernel regularized canonical variate analysis for incipient fault detection in large‐scale processes
To address the problem of balancing sensitivity and robustness in incipient fault detection (IFD) for large‐scale processes, a distributed monitoring framework based on causal‐oriented kernel regularized canonical variate analysis (CO‐KRCVA) is proposed. The framework divides operational units into sub‐blocks according to the sequence of production. To reveal the information transfer relationships and the underlying mechanisms of dynamic changes among variables, a causal difference matrix (CDM) using transfer entropy estimation is constructed for each sub‐block. Based on this, a CO‐KRCVA model is established, which specifically captures targeted minor variations of process variables to enhance the sensitivity and reliability. Its regularization strategy further overcomes the effects of random noise or interference to reduce false alarms. In addition, the Wasserstein distance (WD)‐based statistic is employed to sensitively reflect distribution shifts from both probabilistic and geometric perspectives. To facilitate global detection, Bayesian inference is used to fuse the results from local models. Finally, the proposed method and monitoring framework are validated for effectiveness on different types of faults in the vinyl acetate monomer (VAM) process and Tennessee Eastman (TE) process. Experimental results show that compared with CVA, the proposed method improves the early fault detection rate by 28.47%, 46.21%, and 12.6%, respectively, for the three fault types in the TE process, while reducing the false alarm rate by 0.52%, 1.44%, and 1.36%.
- 12 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 3513310
Fault Path Tracing and Root Cause Diagnosis Based on Semifrozen Autoencoder
Root cause diagnosis in complex industrial processes is challenged by the smearing effect of contribution plots, the nonlinearity and indirect causality issues of Granger causality and transfer entropy, and the separation between contribution analysis and causal inference. To address these limitations, this paper proposes a semi-frozen auto-encoder (SFAE) with orthogonal constraint and integrated causal-contribution graph. Offline, an auto-encoder with orthogonality constraint is trained on normal data to decouple variable contributions and construct a directed causal graph from the trained weights. Online, the encoder is frozen and only the decoder is updated; the decoder weights directly provide variable contributions. The top-three contributing variables are selected, and the subgraph among them extracted from the offline causal graph reveals the fault propagation path and root cause. Unlike existing methods that treat contribution analysis and causal inference separately, our framework unifies them in a single auto-encoder architecture. Experimental results demonstrate superior root cause localization accuracy, robustness to measurement noise, and interpretable fault propagation paths.
- 12 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 3513310
Fault Path Tracing and Root Cause Diagnosis Based on Semifrozen Autoencoder
Root cause diagnosis in complex industrial processes is challenged by the smearing effect of contribution plots, the nonlinearity and indirect causality issues of Granger causality and transfer entropy, and the separation between contribution analysis and causal inference. To address these limitations, this paper proposes a semi-frozen auto-encoder (SFAE) with orthogonal constraint and integrated causal-contribution graph. Offline, an auto-encoder with orthogonality constraint is trained on normal data to decouple variable contributions and construct a directed causal graph from the trained weights. Online, the encoder is frozen and only the decoder is updated; the decoder weights directly provide variable contributions. The top-three contributing variables are selected, and the subgraph among them extracted from the offline causal graph reveals the fault propagation path and root cause. Unlike existing methods that treat contribution analysis and causal inference separately, our framework unifies them in a single auto-encoder architecture. Experimental results demonstrate superior root cause localization accuracy, robustness to measurement noise, and interpretable fault propagation paths.
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 3513115
A Measurement-Oriented Spatiotemporal Subspace Network for Monitoring Nonstationary Industrial Processes
A fundamental challenge in industrial instrumentation is the reliable measurement and monitoring of nonstationary processes, where the sensitivity and accuracy of traditional fault detection systems are frequently jeopardized by changing spatial and temporal variations. This paper introduces the Extended Temporal and Spatial Stationary Subspace Network (ETS3N), a novel framework designed to enhance measurement reliability by jointly modeling temporal homogeneity and spatial heterogeneity in multivariate process signals. In order to maintain the time-space-dependent coherence necessary for local stationarity assumptions, the architecture incorporates three essential units: (1) the Temporal Homogeneity Enumeration Unit (THEU), which reinforces intrinsic temporal coherence to support robust feature extraction; (2) the Spatial Heterogeneity Extraction Unit (SHEU), which constructs a triple-branch convolutional structure with functional independence and diversity constraints to decouple heterogeneous sensor responses; and (3) the Spatio-Temporal Amalgamation Decoupling Unit (STADU), which separates stationary and nonstationary components for interpretable monitoring. With the help of this deep measurement model, latent process dynamics can be accurately extracted, improving fault detection, measurement, and process state comprehension. Validation on both simulated and real-world industrial datasets, such as the blast furnace iron production process and the Secure Water Treatment (SWaT) system, shows that ETS3N outperforms current techniques in terms of sensitivity, stability, and fault isolation. The suggested method aids in the creation of future measurement systems for intricate, dynamic industrial settings.
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 3513115
A Measurement-Oriented Spatiotemporal Subspace Network for Monitoring Nonstationary Industrial Processes
A fundamental challenge in industrial instrumentation is the reliable measurement and monitoring of nonstationary processes, where the sensitivity and accuracy of traditional fault detection systems are frequently jeopardized by changing spatial and temporal variations. This paper introduces the Extended Temporal and Spatial Stationary Subspace Network (ETS3N), a novel framework designed to enhance measurement reliability by jointly modeling temporal homogeneity and spatial heterogeneity in multivariate process signals. In order to maintain the time-space-dependent coherence necessary for local stationarity assumptions, the architecture incorporates three essential units: (1) the Temporal Homogeneity Enumeration Unit (THEU), which reinforces intrinsic temporal coherence to support robust feature extraction; (2) the Spatial Heterogeneity Extraction Unit (SHEU), which constructs a triple-branch convolutional structure with functional independence and diversity constraints to decouple heterogeneous sensor responses; and (3) the Spatio-Temporal Amalgamation Decoupling Unit (STADU), which separates stationary and nonstationary components for interpretable monitoring. With the help of this deep measurement model, latent process dynamics can be accurately extracted, improving fault detection, measurement, and process state comprehension. Validation on both simulated and real-world industrial datasets, such as the blast furnace iron production process and the Secure Water Treatment (SWaT) system, shows that ETS3N outperforms current techniques in terms of sensitivity, stability, and fault isolation. The suggested method aids in the creation of future measurement systems for intricate, dynamic industrial settings.
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (6) , 4932-4943
A Novel Self-Supervised Orthogonal Decoupling Autoencoder for Industrial Process Sensor Fault Detection and Diagnosis
Accurate sensor fault detection and diagnosis in industrial processes are essential for maintaining system reliability and operational safety. However, under closed-loop control conditions, the presence of inherent nonlinearities, strong multivariate coupling, and subtle fault signatures poses significant challenges to effective monitoring. To address these issues, this article proposes a novel self-supervised orthogonal decoupling autoencoder (SODAE). The core component of the model, the orthogonal decoupling autoencoder (ODAE), achieves robust feature extraction by decoupling interdependent sensor relationships through the optimization of weight matrices on the Stiefel manifold, supported by theoretical analysis. In parallel, a self-supervised learning mechanism is integrated via adversarial training to enhance sensitivity to minor sensor anomalies. The proposed SODAE is evaluated on a simulated benchmark with customized sensor fault scenarios, as well as on two complex real-world water treatment processes. Experimental results demonstrate that SODAE achieves superior performance in both sensor fault detection and diagnosis under challenging industrial conditions.
- 13 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (6) , 4932-4943
A Novel Self-Supervised Orthogonal Decoupling Autoencoder for Industrial Process Sensor Fault Detection and Diagnosis
Accurate sensor fault detection and diagnosis in industrial processes are essential for maintaining system reliability and operational safety. However, under closed-loop control conditions, the presence of inherent nonlinearities, strong multivariate coupling, and subtle fault signatures poses significant challenges to effective monitoring. To address these issues, this article proposes a novel self-supervised orthogonal decoupling autoencoder (SODAE). The core component of the model, the orthogonal decoupling autoencoder (ODAE), achieves robust feature extraction by decoupling interdependent sensor relationships through the optimization of weight matrices on the Stiefel manifold, supported by theoretical analysis. In parallel, a self-supervised learning mechanism is integrated via adversarial training to enhance sensitivity to minor sensor anomalies. The proposed SODAE is evaluated on a simulated benchmark with customized sensor fault scenarios, as well as on two complex real-world water treatment processes. Experimental results demonstrate that SODAE achieves superior performance in both sensor fault detection and diagnosis under challenging industrial conditions.
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Hierarchical Key-Historical-Information Transfer Method for Limited-Sample Operating Conditions Monitoring
Industrial processes often operate under multiple operating conditions. Monitoring for unusual modes is a challenge due to the limited availability of samples. In this article, a hierarchical key-historical-information transfer (HkhiT) and subspaces monitoring method is proposed for processes with multiple operating conditions, where historical operating conditions knowledge is transferred hierarchically for limited-sample fault detection. First, a well-conditioned covariance matrix is constructed within the target sample subspace; this procedure mitigates correlation-estimation uncertainty under limited-sample conditions. The principal monitoring subspace then integrates historical correlation information to regularize the target correlation structure. Subsequently, the complementary monitoring subspace extracts latent variables that are sensitive to process disturbances, thereby achieving more comprehensive monitoring of online variations. With limited training data, the decision fusion of the principal and complementary monitoring subspaces provides robust monitoring performance. Finally, the effectiveness of the proposed method is demonstrated through a numerical case and the Tennessee Eastman process.
- 15 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Hierarchical Key-Historical-Information Transfer Method for Limited-Sample Operating Conditions Monitoring
Industrial processes often operate under multiple operating conditions. Monitoring for unusual modes is a challenge due to the limited availability of samples. In this article, a hierarchical key-historical-information transfer (HkhiT) and subspaces monitoring method is proposed for processes with multiple operating conditions, where historical operating conditions knowledge is transferred hierarchically for limited-sample fault detection. First, a well-conditioned covariance matrix is constructed within the target sample subspace; this procedure mitigates correlation-estimation uncertainty under limited-sample conditions. The principal monitoring subspace then integrates historical correlation information to regularize the target correlation structure. Subsequently, the complementary monitoring subspace extracts latent variables that are sensitive to process disturbances, thereby achieving more comprehensive monitoring of online variations. With limited training data, the decision fusion of the principal and complementary monitoring subspaces provides robust monitoring performance. Finally, the effectiveness of the proposed method is demonstrated through a numerical case and the Tennessee Eastman process.
- Top Cited Papers
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (4) , 3517-3526
Quality-Related Fault Detection Based on Reversible Instance Normalization Temporal Auto-Encoder Canonical Correlation Analysis
In contemporary industrial processes, factors such as raw material fluctuations and noise interference lead to significant changes in the statistical characteristics of data over time, resulting in nonstationary behavior. This nonstationary tends to obscure fault-related information in industrial systems, posing severe challenges for quality-related fault detection. This article proposes a method named reversible instance normalization temporal autoencoder (TAE) canonical correlation analysis (CCA) for quality related fault detection. First, this method quantifies the interdependencies among variables to select process variables that are highly correlated with quality indicators. Subsequently, a reversible normalization module dynamically adjusts normalization parameters to achieve local stationarization of process data. Furthermore, a TAE is utilized to extract temporal features from processed data. Then, a CCA model is established by integrating quality indicators, enabling efficient monitoring of quality indicator under nonstationary conditions. Finally, the proposed method was tested and validated in two real industrial cases.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 22 (4) , 3517-3526
Top Cited PapersQuality-Related Fault Detection Based on Reversible Instance Normalization Temporal Auto-Encoder Canonical Correlation Analysis
In contemporary industrial processes, factors such as raw material fluctuations and noise interference lead to significant changes in the statistical characteristics of data over time, resulting in nonstationary behavior. This nonstationary tends to obscure fault-related information in industrial systems, posing severe challenges for quality-related fault detection. This article proposes a method named reversible instance normalization temporal autoencoder (TAE) canonical correlation analysis (CCA) for quality related fault detection. First, this method quantifies the interdependencies among variables to select process variables that are highly correlated with quality indicators. Subsequently, a reversible normalization module dynamically adjusts normalization parameters to achieve local stationarization of process data. Furthermore, a TAE is utilized to extract temporal features from processed data. Then, a CCA model is established by integrating quality indicators, enabling efficient monitoring of quality indicator under nonstationary conditions. Finally, the proposed method was tested and validated in two real industrial cases.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Multitier Dynamic Dual Kullback–Leibler Divergence Based on Manifold and Sensitive Features for Incipient Fault Detection
To solve the problem of incipient fault detection in an effective and timely manner, a multitier dynamic dual Kullback–Leibler Divergence (MDD-KLD) based on manifold and sensitive features is proposed. Firstly, the subspace highlighting the dynamic trend of the data is constructed using an exponentially weighted moving average window on the basis of manifold learning. Then, two sensitive detection indicators are constructed by leveraging the sensitivity of the KLD to minor changes in the probability distribution of the data, which is called dynamic dual KL divergence model. In addition, by calculating the KLD between normal data and priori fault data to determine the optimal sensitive variable subblock for a specific fault, the fault sensitive features are extracted to construct a complementary detection model, which supports the primary detection model, resulting in the multitier dynamic dual-KL divergence (MDD-KLD) model. Finally, testing on an industrial case showed that the primary model attains 97% average accuracy for routine faults, while the complementary detection model further enhances both accuracy and fault detection time for incipient faults relative to the primary model.
- 29 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Multitier Dynamic Dual Kullback–Leibler Divergence Based on Manifold and Sensitive Features for Incipient Fault Detection
To solve the problem of incipient fault detection in an effective and timely manner, a multitier dynamic dual Kullback–Leibler Divergence (MDD-KLD) based on manifold and sensitive features is proposed. Firstly, the subspace highlighting the dynamic trend of the data is constructed using an exponentially weighted moving average window on the basis of manifold learning. Then, two sensitive detection indicators are constructed by leveraging the sensitivity of the KLD to minor changes in the probability distribution of the data, which is called dynamic dual KL divergence model. In addition, by calculating the KLD between normal data and priori fault data to determine the optimal sensitive variable subblock for a specific fault, the fault sensitive features are extracted to construct a complementary detection model, which supports the primary detection model, resulting in the multitier dynamic dual-KL divergence (MDD-KLD) model. Finally, testing on an industrial case showed that the primary model attains 97% average accuracy for routine faults, while the complementary detection model further enhances both accuracy and fault detection time for incipient faults relative to the primary model.