Benjamin K. Miller
Research Subjects
Research Interests
Benjamin K. Miller has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Peter A. Crozier
Arizona State University
7 shared publications Anahita Pakzad
Gatan, Inc . Pleasanton, CA , United States
3 shared publicationsBernhard Schaffer
Gatan, Inc . Pleasanton, CA , United States
3 shared publications- Chanchal Ghosh
Indira Gandhi Centre for Atomic Research
3 shared publications Cory Czarnik
Gatan, Inc. , Pleasanton, CA , United States
3 shared publications- Manish Kumar Singh
Center for Integrated Nanotechnologies Los Alamos National Laboratory Los Alamos NM 87545 USA
3 shared publications
Latest Publications
- Open Access
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Results Before Lunch: Capturing and Processing In Situ 5D STEM
4D STEM is a powerful collection of techniques for capturing rich structural data. Faster cameras and detectors have made it possible to acquire this data rapidly, but to achieve an optimal field of view and resolution in both real and reciprocal space, large data volumes are necessary. Adding the fifth dimension of time to capture an entire series of 4D data cubes during an in-situ experiment leads to even larger data volumes [ 1]. The mostly manual recording and processing of continuous 4D STEM (5D) datasets has resulted in only a few labs pursuing this approach in the past.
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Open AccessResults Before Lunch: Capturing and Processing In Situ 5D STEM
4D STEM is a powerful collection of techniques for capturing rich structural data. Faster cameras and detectors have made it possible to acquire this data rapidly, but to achieve an optimal field of view and resolution in both real and reciprocal space, large data volumes are necessary. Adding the fifth dimension of time to capture an entire series of 4D data cubes during an in-situ experiment leads to even larger data volumes [ 1]. The mostly manual recording and processing of continuous 4D STEM (5D) datasets has resulted in only a few labs pursuing this approach in the past.
- Open Access
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Deleting a Diffraction Dimension – Real-Time In Situ Visualization via Python
Observation of phase transformations or structural damage caused by in-situ stimuli or the electron beam itself are common objectives for in-situ TEM. “Did a phase transformation occur?” is often the first question the data must be used to answer, ideally while still sitting at the microscope. If this is only determined during later detailed data analysis, the user may find that no transformation took place, and they need to redo the experiment, altering the in-situ conditions somehow. Or they may find that the sample was badly damaged during their in-situ experiment, making the results difficult to interpret.
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Open AccessDeleting a Diffraction Dimension – Real-Time In Situ Visualization via Python
Observation of phase transformations or structural damage caused by in-situ stimuli or the electron beam itself are common objectives for in-situ TEM. “Did a phase transformation occur?” is often the first question the data must be used to answer, ideally while still sitting at the microscope. If this is only determined during later detailed data analysis, the user may find that no transformation took place, and they need to redo the experiment, altering the in-situ conditions somehow. Or they may find that the sample was badly damaged during their in-situ experiment, making the results difficult to interpret.
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 271
Continuous 4D STEM Recording and Visualization for In-situ Experiments
As faster electron detectors allow for large scanning transmission electron microscopy (STEM) diffraction data collection in a reasonable amount of time, 4D STEM has become a powerful STEM technique that is nearly ubiquitous in electron microscopy labs worldwide. To achieve useful resolution and field of view in both real and reciprocal space, large data volumes are required. Adding the fifth dimension of time to capture a series of 4D data cubes in an in-situ experiment leads to even larger data volumes [ 1], and continuous recording and processing of 4D STEM datasets has mostly remained a manual and tedious process.
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 271
Open AccessContinuous 4D STEM Recording and Visualization for In-situ Experiments
As faster electron detectors allow for large scanning transmission electron microscopy (STEM) diffraction data collection in a reasonable amount of time, 4D STEM has become a powerful STEM technique that is nearly ubiquitous in electron microscopy labs worldwide. To achieve useful resolution and field of view in both real and reciprocal space, large data volumes are required. Adding the fifth dimension of time to capture a series of 4D data cubes in an in-situ experiment leads to even larger data volumes [ 1], and continuous recording and processing of 4D STEM datasets has mostly remained a manual and tedious process.
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 1835-1837
Assessing Critical Dose for Beam-sensitive Samples using Low-dose Counted in-situ Video
While transmission electron microscopy (TEM) can elucidate the structure of nanomaterials from the micro to the atomic scale, many functional materials are beam sensitive. This has made TEM characterization difficult or even impossible for some materials. The definition of “beam-sensitive” can vary greatly depending on who defines it and at what resolution the sample is observed. For the single-particle cryo-electron microscopy (cryo-EM) community, an accumulated dose of just tens of electrons per angstrom squared (e-/Å2) is enough to destroy a sample, but atomic resolution imaging of an individual protein is not expected [ 1, 2]. For researchers studying materials at the atomic scale, a total dose of several thousand e-/Å2 may be considered low-dose, especially if the dose rate is low [ 3]. In contrast, for traditional atomic resolution imaging of robust TEM samples, the total dose may be on the order of 104-105 e-/Å2. Techniques that capture more than one image, like tomography, 4D STEM, or in-situ experiments, also tend to require larger electron doses. Whatever the magnitude of the critical dose above which a structure is likely to be significantly damaged, observation of the pristine material without damage is desired.
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 1835-1837
Open AccessAssessing Critical Dose for Beam-sensitive Samples using Low-dose Counted in-situ Video
While transmission electron microscopy (TEM) can elucidate the structure of nanomaterials from the micro to the atomic scale, many functional materials are beam sensitive. This has made TEM characterization difficult or even impossible for some materials. The definition of “beam-sensitive” can vary greatly depending on who defines it and at what resolution the sample is observed. For the single-particle cryo-electron microscopy (cryo-EM) community, an accumulated dose of just tens of electrons per angstrom squared (e-/Å2) is enough to destroy a sample, but atomic resolution imaging of an individual protein is not expected [ 1, 2]. For researchers studying materials at the atomic scale, a total dose of several thousand e-/Å2 may be considered low-dose, especially if the dose rate is low [ 3]. In contrast, for traditional atomic resolution imaging of robust TEM samples, the total dose may be on the order of 104-105 e-/Å2. Techniques that capture more than one image, like tomography, 4D STEM, or in-situ experiments, also tend to require larger electron doses. Whatever the magnitude of the critical dose above which a structure is likely to be significantly damaged, observation of the pristine material without damage is desired.
- 22 July 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (S1) , 128-129
Extensible Real-Time Data Processing with Python in DigitalMicrograph
- 22 July 2022
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 28 (S1) , 128-129
Extensible Real-Time Data Processing with Python in DigitalMicrograph
- Open Access
- 30 July 2021
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 27 (S1) , 1240-1242
Investigation of Phase Transformations in Ge4Sb4Te5 film using Transmission Electron Microscopy
Investigation of Phase Transformations in Ge4Sb4Te5 film using Transmission Electron Microscopy - Volume 27 Issue S1
- 30 July 2021
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 27 (S1) , 1240-1242
Open AccessInvestigation of Phase Transformations in Ge4Sb4Te5 film using Transmission Electron Microscopy
Investigation of Phase Transformations in Ge4Sb4Te5 film using Transmission Electron Microscopy - Volume 27 Issue S1
- Open Access
- 30 July 2021
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 27 (S1) , 1352-1354
Using py4DSTEM in GMS: Hybrid Open-Source, Commercial-Freeware Methods for Analyzing 4D STEM Datasets
- 30 July 2021
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 27 (S1) , 1352-1354
Open AccessUsing py4DSTEM in GMS: Hybrid Open-Source, Commercial-Freeware Methods for Analyzing 4D STEM Datasets
- 11 May 2021
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 27 (4) , 659-665
Direct Visualization of the Earliest Stages of Crystallization
Investigating the earliest stages of crystallization requires the transmission electron microscope (TEM) and is particularly challenging for materials which can be affected by the electron beam. Typically, when imaging at magnifications high enough to observe local crystallinity, the electron beam's current density must be high to produce adequate image contrast. Yet, minimizing the electron dose is necessary to reduce the changes caused by the beam. With the advent of a sensitive, high-speed, direct-detection camera for a TEM that is corrected for spherical aberration, it is possible to probe the early stages of crystallization at the atomic scale. High-quality images with low contrast can now be analyzed using new computing methods. In the present paper, this approach is illustrated for crystallization in a Ge2Sb2Te5 (GST-225) phase-change material which can undergo particularly rapid phase transformations and is sensitive to the electron beam. A thin (20 nm) film of GST-225 has been directly imaged in the TEM and the low-dose images processed using Python scripting to extract details of the nanoscale nuclei. Quantitative analysis of the processed images in a video sequence also allows the growth of such nuclei to be followed.
- 11 May 2021
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 27 (4) , 659-665
Direct Visualization of the Earliest Stages of Crystallization
Investigating the earliest stages of crystallization requires the transmission electron microscope (TEM) and is particularly challenging for materials which can be affected by the electron beam. Typically, when imaging at magnifications high enough to observe local crystallinity, the electron beam's current density must be high to produce adequate image contrast. Yet, minimizing the electron dose is necessary to reduce the changes caused by the beam. With the advent of a sensitive, high-speed, direct-detection camera for a TEM that is corrected for spherical aberration, it is possible to probe the early stages of crystallization at the atomic scale. High-quality images with low contrast can now be analyzed using new computing methods. In the present paper, this approach is illustrated for crystallization in a Ge2Sb2Te5 (GST-225) phase-change material which can undergo particularly rapid phase transformations and is sensitive to the electron beam. A thin (20 nm) film of GST-225 has been directly imaged in the TEM and the low-dose images processed using Python scripting to extract details of the nanoscale nuclei. Quantitative analysis of the processed images in a video sequence also allows the growth of such nuclei to be followed.
- 1 November 2020
- Published by Elsevier in Ultramicroscopy
- Vol. 218, 113080
Chemical kinetics for operando electron microscopy of catalysts: 3D modeling of gas and temperature distributions during catalytic reactions
- 1 November 2020
- Published by Elsevier in Ultramicroscopy
- Vol. 218, 113080
Chemical kinetics for operando electron microscopy of catalysts: 3D modeling of gas and temperature distributions during catalytic reactions
- 28 September 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (12) , 124505
In situ TEM study of crystallization and chemical changes in an oxidized uncapped Ge2Sb2Te5 film
Ge2Sb2Te5 (GST-225) has been the most used active material in nonvolatile phase-change memory devices. Understanding the kinetics and dynamics involved in crystallization is critical for the optimization of materials and devices. A GST-225 thin film of 20 nm thickness was prepared by sputtering directly onto a Protochip and left uncapped and exposed to atmosphere for approximately 1 year. Early stages of crystallization and growth of the film have been studied inside the TEM from room temperature to 140 °C. The morphological and structural transformations have been studied by a Cs-corrected environmental TEM, and images have been recorded using a high-speed low electron dose camera (Gatan K3 IS). The amorphous to crystalline transformation has been observed at ∼35 °C. From the large field, high-resolution images obtained using the Gatan K3 IS camera early crystallization can be detected and nucleation rates and growth velocities can be obtained.
- 28 September 2020
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 128 (12) , 124505
In situ TEM study of crystallization and chemical changes in an oxidized uncapped Ge2Sb2Te5 film
Ge2Sb2Te5 (GST-225) has been the most used active material in nonvolatile phase-change memory devices. Understanding the kinetics and dynamics involved in crystallization is critical for the optimization of materials and devices. A GST-225 thin film of 20 nm thickness was prepared by sputtering directly onto a Protochip and left uncapped and exposed to atmosphere for approximately 1 year. Early stages of crystallization and growth of the film have been studied inside the TEM from room temperature to 140 °C. The morphological and structural transformations have been studied by a Cs-corrected environmental TEM, and images have been recorded using a high-speed low electron dose camera (Gatan K3 IS). The amorphous to crystalline transformation has been observed at ∼35 °C. From the large field, high-resolution images obtained using the Gatan K3 IS camera early crystallization can be detected and nucleation rates and growth velocities can be obtained.