Xin-Yang Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xin-Yang Chen has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Fang-Zhen Teng
Isotope Laboratory, Department of Earth and Space Sciences, University of Washington, Seattle, WA 98195, USA
6 shared publications Henry S. Chafetz
4 shared publicationsThomas J. Lapen
4 shared publications- Yan Hu
Université Paris Cité, Institut de Physique du Globe de Paris, CNRS, Paris, France
2 shared publications Ying-Kui Xu
2 shared publicationsAntonio Sanchez-Navas
1 shared publication
Latest Publications
- 1 October 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 287, 263-276
Intensified chemical weathering during Early Triassic revealed by magnesium isotopes
- 1 October 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 287, 263-276
Intensified chemical weathering during Early Triassic revealed by magnesium isotopes
- 1 August 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 283, 184-200
Silicon isotope variations in hydrothermal systems at Yellowstone National Park, Wyoming, U.S.A.
- 1 August 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 283, 184-200
Silicon isotope variations in hydrothermal systems at Yellowstone National Park, Wyoming, U.S.A.
- 1 July 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 281, 102-117
Experimental constraints on magnesium isotope fractionation during abiogenic calcite precipitation at room temperature
- 1 July 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 281, 102-117
Experimental constraints on magnesium isotope fractionation during abiogenic calcite precipitation at room temperature
- 1 June 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 278, 122-136
Heterogeneous potassium isotopic composition of the upper continental crust
- 1 June 2020
- Published by Elsevier in Geochimica et Cosmochimica Acta
- Vol. 278, 122-136
Heterogeneous potassium isotopic composition of the upper continental crust
- 1 May 2019
- Published by Elsevier in Chemical Geology
- Vol. 513, 101-107
Potassium isotopic compositions of international geological reference materials
- 1 May 2019
- Published by Elsevier in Chemical Geology
- Vol. 513, 101-107
Potassium isotopic compositions of international geological reference materials
- 15 April 2019
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 33 (14) , 1169-1178
Fast and precise boron isotopic analysis of carbonates and seawater using Nu Plasma II multi‐collector inductively coupled plasma mass spectrometry and a simple sample introduction system
Rationale: The boron (B) isotopic composition in marine carbonates provides important insights into paleoclimate reconstruction and biomineralization. However, precise and accurate measurements of B isotopes using plasma‐based mass spectrometry is difficult due to the volatile nature of B, which typically requires complex and more specialized sample introduction systems. Existing analytical protocols have mostly been based on Thermo Scientific Neptune Plus multi‐collector inductively coupled plasma mass spectrometry (MC‐ICPMS) instruments, whereas methods based on Nu Plasma mass spectrometers are scarce. Methods: We have developed a simplified analytical protocol using Nu Plasma II MC‐ICPMS with standard glass sample introduction systems. Boron extraction and purification were conducted using a two‐stage column chemistry with cation‐exchange and Amberlite IRA 743 B‐specific resin. A sample drying step was avoided, which allows for direct isotopic analysis after column chemistry. A wet plasma mode with a standard glass cyclonic spray chamber and a glass nebulizer was used instead of a more specialized perfluoroalkoxy (PFA) sample introduction system. Low residual B signals were achieved with a relatively short period of wash‐out with 0.5 N HNO 3 . Results: The external precision is better than 0.30‰ (2SD) calculated from the long‐term bracketing standard, NIST SRM 951a. The overall robustness of the method was demonstrated by measurements of the international carbonate standard JCp‐1 (δ 11 B = +24.49 ± 0.36‰, 2SD) and seawater (δ 11 B = +39.98 ± 0.35‰), which are consistent with reported values. Conclusions: Our method provides an alternative approach for B isotope analysis using a routine wet plasma MC‐ICPMS setup that can facilitate geochemical and environmental application of B isotopes.
- 15 April 2019
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 33 (14) , 1169-1178
Fast and precise boron isotopic analysis of carbonates and seawater using Nu Plasma II multi‐collector inductively coupled plasma mass spectrometry and a simple sample introduction system
Rationale: The boron (B) isotopic composition in marine carbonates provides important insights into paleoclimate reconstruction and biomineralization. However, precise and accurate measurements of B isotopes using plasma‐based mass spectrometry is difficult due to the volatile nature of B, which typically requires complex and more specialized sample introduction systems. Existing analytical protocols have mostly been based on Thermo Scientific Neptune Plus multi‐collector inductively coupled plasma mass spectrometry (MC‐ICPMS) instruments, whereas methods based on Nu Plasma mass spectrometers are scarce. Methods: We have developed a simplified analytical protocol using Nu Plasma II MC‐ICPMS with standard glass sample introduction systems. Boron extraction and purification were conducted using a two‐stage column chemistry with cation‐exchange and Amberlite IRA 743 B‐specific resin. A sample drying step was avoided, which allows for direct isotopic analysis after column chemistry. A wet plasma mode with a standard glass cyclonic spray chamber and a glass nebulizer was used instead of a more specialized perfluoroalkoxy (PFA) sample introduction system. Low residual B signals were achieved with a relatively short period of wash‐out with 0.5 N HNO 3 . Results: The external precision is better than 0.30‰ (2SD) calculated from the long‐term bracketing standard, NIST SRM 951a. The overall robustness of the method was demonstrated by measurements of the international carbonate standard JCp‐1 (δ 11 B = +24.49 ± 0.36‰, 2SD) and seawater (δ 11 B = +39.98 ± 0.35‰), which are consistent with reported values. Conclusions: Our method provides an alternative approach for B isotope analysis using a routine wet plasma MC‐ICPMS setup that can facilitate geochemical and environmental application of B isotopes.
- 1 August 2018
- Published by Elsevier in Chemical Geology
- Vol. 493, 100-108
High-precision analysis of potassium isotopes by HR-MC-ICPMS
- 1 August 2018
- Published by Elsevier in Chemical Geology
- Vol. 493, 100-108
High-precision analysis of potassium isotopes by HR-MC-ICPMS
- 20 January 2017
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 41 (3) , 427-435
Accurate and Precise Silicon Isotope Analysis of Sulfur‐ and Iron‐Rich Samples by MC‐ICP‐MS
Silicon isotope determination of sulfur‐rich samples by MC‐ICP‐MS can be challenging because cation‐exchange chromatography used for Si purification does not efficiently remove anionic sulfur species. Results for pure Si standard solutions with addition of sulfate showed shifts of up to +1.04 ± 0.10‰ (2s) in δ30Si. Doping of both standard solutions and samples with S to a fixed S/Si ratio can eliminate the relative change in instrumental mass fractionation due to variable S/Si in samples and also boosts the relative sensitivity of Si by up to 66%. Moreover, Fe hydroxide precipitation during sample processing adsorbs Si resulting in isotopic fractionations. Tests using Fe‐rich samples showed that this could be a major factor for observed shifts in δ30Si. Acidification of the sample and standard solutions to a pH < 1 aggressively dissolved any Fe hydroxide precipitates, even in relatively Fe‐rich samples such as chondrite meteorites. The pH values of the sample solutions were subsequently adjusted to a range of 2–3 by adding ultra‐pure NaOH solutions. The combination of sulfur doping and the pH adjustment protocol ensured a full recovery of Si and proved to be an efficient and reliable method for Si isotope determination of S‐ and Fe‐rich materials.
- 20 January 2017
- Published by Wiley in Geostandards and Geoanalytical Research
- Vol. 41 (3) , 427-435
Accurate and Precise Silicon Isotope Analysis of Sulfur‐ and Iron‐Rich Samples by MC‐ICP‐MS
Silicon isotope determination of sulfur‐rich samples by MC‐ICP‐MS can be challenging because cation‐exchange chromatography used for Si purification does not efficiently remove anionic sulfur species. Results for pure Si standard solutions with addition of sulfate showed shifts of up to +1.04 ± 0.10‰ (2s) in δ30Si. Doping of both standard solutions and samples with S to a fixed S/Si ratio can eliminate the relative change in instrumental mass fractionation due to variable S/Si in samples and also boosts the relative sensitivity of Si by up to 66%. Moreover, Fe hydroxide precipitation during sample processing adsorbs Si resulting in isotopic fractionations. Tests using Fe‐rich samples showed that this could be a major factor for observed shifts in δ30Si. Acidification of the sample and standard solutions to a pH < 1 aggressively dissolved any Fe hydroxide precipitates, even in relatively Fe‐rich samples such as chondrite meteorites. The pH values of the sample solutions were subsequently adjusted to a range of 2–3 by adding ultra‐pure NaOH solutions. The combination of sulfur doping and the pH adjustment protocol ensured a full recovery of Si and proved to be an efficient and reliable method for Si isotope determination of S‐ and Fe‐rich materials.
- 1 March 2016
- Published by Elsevier in Chemical Geology
- Vol. 423, 61-73
Silicon isotope compositions of euhedral authigenic quartz crystals: Implications for abiotic fractionation at surface temperatures
- 1 March 2016
- Published by Elsevier in Chemical Geology
- Vol. 423, 61-73
Silicon isotope compositions of euhedral authigenic quartz crystals: Implications for abiotic fractionation at surface temperatures