Ashraf Mohmoud EL Sherbini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ashraf Mohmoud EL Sherbini has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Christian G. Parigger
Physics and Astronomy Department, University of Tennessee, University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700, USA
9 shared publications - Tharwat Mohmoud EL Sherbini
Laboratory of Lasers and New Materials, Department of Physics, Cairo University, Giza 12613, Egypt
7 shared publications - AbdelNasser Aboulfotouh
Laboratory of Lasers and New Materials, Department of Physics, Cairo University, Giza 12613, Egypt
3 shared publications H. Hegazy
Atomic Energy Authority, Nuclear Research Center, Plasma Physics Department , Enchass, Egypt
3 shared publicationsTharwat M. EL Sherbini
Cairo Univ, Fac Sci, Dept Phys, Lab Laser & New Mat, Giza 12613, Egypt
3 shared publicationsA. Salvetti
Applied Laser Spectroscopy Laboratory , Institute for Chemical‐Physical Processes, Research Area of National Research Council , Pisa, Italy
2 shared publications
Latest Publications
- Open Access
- 28 November 2025
- Published by MDPI AG in Quantum Beam Science
- Vol. 9 (4) , 34
Temporal Variation in Nano-Enhanced Laser-Induced Plasma Spectroscopy (NELIPS)
The NELIPS acronym stands for Nano-Enhanced Laser-Induced Plasma Spectroscopy. Within this framework, the temporal variation in the enhanced plasma emissions from pure nanomaterials with respect to corresponding bulk materials was monitored as a function of delay time in the range from 1 to 5–11 μs. Six different pure nanomaterials were employed including silver, zinc, aluminum, titanium, iron, and silicon. Radiation from pulsed Nd: YAG laser at wavelength 1064 nm was used to induce both bulk and pure nanomaterial plasmas under similar experimental conditions. Plasma emissions from both targets were monitored via optical emission spectroscopy technique (OES). The spectral line intensities (Signal-To-Noise ratio S/N) from the pure nanomaterial plasma turns out to decline in a constant logarithmic manner but at a slower rate than that from the corresponding bulk material plasma. Consequently, the measured average enhanced emission from different nanomaterials features an increase in an exponential manner with delay time. This trend of increase was accounted for via mathematical elaboration of enhanced emission based on the measured Signal-To-Noise data. Plasma parameters (electron density and temperature) were precisely measured at each delay time as well.
- 28 November 2025
- Published by MDPI AG in Quantum Beam Science
- Vol. 9 (4) , 34
Open AccessTemporal Variation in Nano-Enhanced Laser-Induced Plasma Spectroscopy (NELIPS)
The NELIPS acronym stands for Nano-Enhanced Laser-Induced Plasma Spectroscopy. Within this framework, the temporal variation in the enhanced plasma emissions from pure nanomaterials with respect to corresponding bulk materials was monitored as a function of delay time in the range from 1 to 5–11 μs. Six different pure nanomaterials were employed including silver, zinc, aluminum, titanium, iron, and silicon. Radiation from pulsed Nd: YAG laser at wavelength 1064 nm was used to induce both bulk and pure nanomaterial plasmas under similar experimental conditions. Plasma emissions from both targets were monitored via optical emission spectroscopy technique (OES). The spectral line intensities (Signal-To-Noise ratio S/N) from the pure nanomaterial plasma turns out to decline in a constant logarithmic manner but at a slower rate than that from the corresponding bulk material plasma. Consequently, the measured average enhanced emission from different nanomaterials features an increase in an exponential manner with delay time. This trend of increase was accounted for via mathematical elaboration of enhanced emission based on the measured Signal-To-Noise data. Plasma parameters (electron density and temperature) were precisely measured at each delay time as well.
- Open Access
- 9 October 2025
- Published by MDPI AG in Preprints.org
Temporal Variation of Nano-Enhanced Laser Induced Plasma Spectroscopy (NELIPS)
The NELIPS acronym stands for Nano-Enhanced Laser Induced Plasma Spectroscopy. Within this framework, the temporal variation of the enhanced plasma emission from pure nanomaterials with respect to corresponding bulk materials was monitored as a function of delay time in the range from 1 to 5-11 ms. Six different materials were employed including silver, zinc, aluminum, titanium, iron and silicon . Radiation from pulsed Nd: YAG laser at wavelength 1064 nm was used to induce the bulk and pure nanomaterial plasmas under similar experimental conditions. Plasma emission from both targets was monitored via optical emission spectroscopy technique (OES). The spectral line intensities (signal-to-noise ratio S/N) from the pure nanomaterial plasma turn out to decline in a constant logarithmic manner but at a slower rate than that from the corresponding bulk material plasma. Consequently, the measured average enhanced emission from different nanomaterials features an increase in an exponential manner with delay time. This trend was accounted for by a mathematical elaboration of enhanced emission based on the measured signal-to-noise data. Both plasma parameters (electron density and temperature) evolution during plasma expansion has been illustrated as well.
- 9 October 2025
- Published by MDPI AG in Preprints.org
Open AccessTemporal Variation of Nano-Enhanced Laser Induced Plasma Spectroscopy (NELIPS)
The NELIPS acronym stands for Nano-Enhanced Laser Induced Plasma Spectroscopy. Within this framework, the temporal variation of the enhanced plasma emission from pure nanomaterials with respect to corresponding bulk materials was monitored as a function of delay time in the range from 1 to 5-11 ms. Six different materials were employed including silver, zinc, aluminum, titanium, iron and silicon . Radiation from pulsed Nd: YAG laser at wavelength 1064 nm was used to induce the bulk and pure nanomaterial plasmas under similar experimental conditions. Plasma emission from both targets was monitored via optical emission spectroscopy technique (OES). The spectral line intensities (signal-to-noise ratio S/N) from the pure nanomaterial plasma turn out to decline in a constant logarithmic manner but at a slower rate than that from the corresponding bulk material plasma. Consequently, the measured average enhanced emission from different nanomaterials features an increase in an exponential manner with delay time. This trend was accounted for by a mathematical elaboration of enhanced emission based on the measured signal-to-noise data. Both plasma parameters (electron density and temperature) evolution during plasma expansion has been illustrated as well.
- Open Access
- 1 April 2025
- Published by Egyptian Knowledge Bank in Journal of the Egyptian Society for Basic Sciences-Physics
- Vol. 2 (1) , 1-15
Measurement of the plasma temperature utilizing the signal to background ratio of hydrogen line at 656.27nm
The electron temperature measurement by laser induced plasma spectroscopy (LIPS) in air is carried out using the relative intensity of the hydrogen line at 656.27nm to the total background-noise under the line. The theoretically established ratio is modified to include contributions from different species to the background-noise. The method was applied on plasma generated by focusing laser light at wavelength of 1064 nm onto solid aluminum target in air. Plasma emission is monitored at different laser energies in the range from 175 up to 600 mJ at different delay times from 0 to 5 s. The plasma electron temperature was measured from the slope of Saha-Boltzmann plot of relevant aluminum spectral lines. The theoretically calculated temperatures and measured temperatures are found to linearly increase with laser energy but decrease with delay time. A good agreement between the measured and predicted temperatures from the modified line to background-noise relative intensity formulae is consistently obtained.
- 1 April 2025
- Published by Egyptian Knowledge Bank in Journal of the Egyptian Society for Basic Sciences-Physics
- Vol. 2 (1) , 1-15
Open AccessMeasurement of the plasma temperature utilizing the signal to background ratio of hydrogen line at 656.27nm
The electron temperature measurement by laser induced plasma spectroscopy (LIPS) in air is carried out using the relative intensity of the hydrogen line at 656.27nm to the total background-noise under the line. The theoretically established ratio is modified to include contributions from different species to the background-noise. The method was applied on plasma generated by focusing laser light at wavelength of 1064 nm onto solid aluminum target in air. Plasma emission is monitored at different laser energies in the range from 175 up to 600 mJ at different delay times from 0 to 5 s. The plasma electron temperature was measured from the slope of Saha-Boltzmann plot of relevant aluminum spectral lines. The theoretically calculated temperatures and measured temperatures are found to linearly increase with laser energy but decrease with delay time. A good agreement between the measured and predicted temperatures from the modified line to background-noise relative intensity formulae is consistently obtained.
- Open Access
- 24 December 2024
- Published by MDPI AG in Quantum Beam Science
- Vol. 9 (1) , 1
On the Similarity and Differences Between Nano-Enhanced Laser-Induced Breakdown Spectroscopy and Nano-Enhanced Laser-Induced Plasma Spectroscopy in Laser-Induced Nanomaterials Plasma
The interaction of pulsed lasers with matter involving nanomaterials as a pure target or thin layer deposited on a target initiates transient plasma, which shows strong enhancement in a spectral line emission. This domain of research has been explored via two well-established techniques dubbed NELIBS and NELIPS. These Nano-Enhanced Laser-Induced Breakdown or Plasma Spectroscopy techniques entail similarities as well as differences. The newly defined concept of Nano-Enhanced Laser-Induced Plasma Spectroscopy NELIPS is introduced. Thereupon, certain confusion has arisen from various aspects of the similarities as well as differences between the two techniques. In this article, we will investigate the application of either technique to retrieve relevant data about the enhanced spectral line plasma emission phenomenon. To discriminate between these two techniques, a survey on the nature of the target, the origin of enhancement and prevalent theoretical approaches is presented. In this context, the potential achievements, challenges and expected prospects are comparatively highlighted. This review emphasizes the unique contributions of NELIPS, particularly the advanced approach in nanoscale thermal modeling and spectroscopic applications.
- 24 December 2024
- Published by MDPI AG in Quantum Beam Science
- Vol. 9 (1) , 1
Open AccessOn the Similarity and Differences Between Nano-Enhanced Laser-Induced Breakdown Spectroscopy and Nano-Enhanced Laser-Induced Plasma Spectroscopy in Laser-Induced Nanomaterials Plasma
The interaction of pulsed lasers with matter involving nanomaterials as a pure target or thin layer deposited on a target initiates transient plasma, which shows strong enhancement in a spectral line emission. This domain of research has been explored via two well-established techniques dubbed NELIBS and NELIPS. These Nano-Enhanced Laser-Induced Breakdown or Plasma Spectroscopy techniques entail similarities as well as differences. The newly defined concept of Nano-Enhanced Laser-Induced Plasma Spectroscopy NELIPS is introduced. Thereupon, certain confusion has arisen from various aspects of the similarities as well as differences between the two techniques. In this article, we will investigate the application of either technique to retrieve relevant data about the enhanced spectral line plasma emission phenomenon. To discriminate between these two techniques, a survey on the nature of the target, the origin of enhancement and prevalent theoretical approaches is presented. In this context, the potential achievements, challenges and expected prospects are comparatively highlighted. This review emphasizes the unique contributions of NELIPS, particularly the advanced approach in nanoscale thermal modeling and spectroscopic applications.
- Open Access
- 25 October 2024
- Published by MDPI AG in Preprints.org
On the Similarity and Differences between NELIBS & NELIPS in Laser Induced Nanomaterials Plasma
The interaction of pulsed lasers with matter involving nanomaterials as a pure target or thin layer deposited on a target, initiates transient plasma which shows strong enhancement in a spectral line emission. This domain of research has been explored via two well established techniques dubbed NELIBS and NELIPS. These Nano-Enhanced Laser Induced Breakdown or Plasma Spectroscopy techniques entail similarities as well as differences. Thereupon, certain confusion has arisen from various aspects of the similarities as well as differences between the two techniques. In this article, we will investigate the application of either technique to retrieve relevant data about enhanced spectral line plasma emission phenomenon. To discriminate between these two techniques, survey on the nature of target, the origin of enhancement and prevalent theoretical approaches is presented. Finally, potential achievements, challenges, and the expected prospective are highlighted.
- 25 October 2024
- Published by MDPI AG in Preprints.org
Open AccessOn the Similarity and Differences between NELIBS & NELIPS in Laser Induced Nanomaterials Plasma
The interaction of pulsed lasers with matter involving nanomaterials as a pure target or thin layer deposited on a target, initiates transient plasma which shows strong enhancement in a spectral line emission. This domain of research has been explored via two well established techniques dubbed NELIBS and NELIPS. These Nano-Enhanced Laser Induced Breakdown or Plasma Spectroscopy techniques entail similarities as well as differences. Thereupon, certain confusion has arisen from various aspects of the similarities as well as differences between the two techniques. In this article, we will investigate the application of either technique to retrieve relevant data about enhanced spectral line plasma emission phenomenon. To discriminate between these two techniques, survey on the nature of target, the origin of enhancement and prevalent theoretical approaches is presented. Finally, potential achievements, challenges, and the expected prospective are highlighted.
- Open Access
Opacity Corrections for Resonance Silver Lines in Nano-Material Laser-Induced Plasma
Q-switched laser radiation at wavelengths of 355, 532, and 1064 nm from a Nd: YAG laser was used to generate plasma in laboratory air at the target surface made of nano-silver particles of size 95 ± 10 nm. The emitted resonance spectra from the neutral silver at wavelengths of 327.9 nm and 338.2 nm indicate existence of self-reversal in addition to plasma self-absorption. Both lines were identified in emission spectra at different laser irradiation wavelengths with characteristic dips at the un-shifted central wavelengths. These dips are usually associated with self-reversal. Under similar conditions, plasmas at the corresponding bulk silver target were generated. The recorded emission spectra were compared to those obtained from the nano-material target. The comparisons confirm existence of self-reversal of resonance lines that emerge from plasmas produced at nano-material targets. This work suggests a method for recovery of the spectral line shapes and discusses practical examples. In addition, subsidiary calibration efforts that utilize the Balmer series Hα-line reveal that other Ag I lines at 827.35 nm and 768.7 nm are optically thin under variety of experimental conditions and are well-suited as reference lines for measurement of the laser plasma electron density.
Open AccessOpacity Corrections for Resonance Silver Lines in Nano-Material Laser-Induced Plasma
Q-switched laser radiation at wavelengths of 355, 532, and 1064 nm from a Nd: YAG laser was used to generate plasma in laboratory air at the target surface made of nano-silver particles of size 95 ± 10 nm. The emitted resonance spectra from the neutral silver at wavelengths of 327.9 nm and 338.2 nm indicate existence of self-reversal in addition to plasma self-absorption. Both lines were identified in emission spectra at different laser irradiation wavelengths with characteristic dips at the un-shifted central wavelengths. These dips are usually associated with self-reversal. Under similar conditions, plasmas at the corresponding bulk silver target were generated. The recorded emission spectra were compared to those obtained from the nano-material target. The comparisons confirm existence of self-reversal of resonance lines that emerge from plasmas produced at nano-material targets. This work suggests a method for recovery of the spectral line shapes and discusses practical examples. In addition, subsidiary calibration efforts that utilize the Balmer series Hα-line reveal that other Ag I lines at 827.35 nm and 768.7 nm are optically thin under variety of experimental conditions and are well-suited as reference lines for measurement of the laser plasma electron density.
- Open Access
- 22 June 2019
- Published by MDPI AG in Preprints.org
Opacity Corrections for Resonance Silver Lines in Nano-Material Laser-Induced Plasma
Q-switched laser radiation at wavelengths of 355 nm, 532 nm, and 1064 nm from a Nd: YAG laser was used to generate plasma in laboratory air at the target surface made of compressed nano-silver particles of size 95 ± 10 nm. The emitted resonance spectra from the neutral silver at wavelengths of 327.9 nm and 338.2 nm indicate existence of self-reversal in addition to plasma self-absorption. Both lines were identified in emission spectra at different laser irradiation wavelengths with characteristic dips at the un-shifted central wavelengths. These dips are usually associated with self-reversal. Under similar conditions, plasmas at the corresponding bulk silver target were generated. The recorded emission spectra were compared to those obtained from the nano-material target. The comparisons confirm existence of self-reversal of resonance lines that emerge from plasmas produced at nano-material targets. This work suggests a method for recovery of the spectral line shapes and discusses practical examples. In addition, subsidiary calibration efforts that utilize the Balmer series Hα-line reveal that other Ag I lines at 827.35 nm and 768.7 nm are optically thin under variety of experimental conditions and are well-suited as reference lines for measurement of the laser plasma electron density.
- 22 June 2019
- Published by MDPI AG in Preprints.org
Open AccessOpacity Corrections for Resonance Silver Lines in Nano-Material Laser-Induced Plasma
Q-switched laser radiation at wavelengths of 355 nm, 532 nm, and 1064 nm from a Nd: YAG laser was used to generate plasma in laboratory air at the target surface made of compressed nano-silver particles of size 95 ± 10 nm. The emitted resonance spectra from the neutral silver at wavelengths of 327.9 nm and 338.2 nm indicate existence of self-reversal in addition to plasma self-absorption. Both lines were identified in emission spectra at different laser irradiation wavelengths with characteristic dips at the un-shifted central wavelengths. These dips are usually associated with self-reversal. Under similar conditions, plasmas at the corresponding bulk silver target were generated. The recorded emission spectra were compared to those obtained from the nano-material target. The comparisons confirm existence of self-reversal of resonance lines that emerge from plasmas produced at nano-material targets. This work suggests a method for recovery of the spectral line shapes and discusses practical examples. In addition, subsidiary calibration efforts that utilize the Balmer series Hα-line reveal that other Ag I lines at 827.35 nm and 768.7 nm are optically thin under variety of experimental conditions and are well-suited as reference lines for measurement of the laser plasma electron density.
- Open Access
- 1 June 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1253 (1) , 012002
Nano-particle enhancement of diagnosis with Laser-Induced plasma spectroscopy
This work discusses nano-particle augmentation of signals in laser-induced plasma spectroscopy. Radiation from a Nd: YAG laser device generates optical breakdown at nano-structured target materials. Extensive scientific investigations of different types of nanomaterial explore dependencies on nanoparticle size, laser wavelength and fluence, and time delay to obtain stronger signals from nano-material than from corresponding solid bulk matter. Modelling of the measurements interprets the occurrence of enhanced detectability of atomic species. Opportunities present themselves for biological and spectrochemical synthesis.
- 1 June 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1253 (1) , 012002
Open AccessNano-particle enhancement of diagnosis with Laser-Induced plasma spectroscopy
This work discusses nano-particle augmentation of signals in laser-induced plasma spectroscopy. Radiation from a Nd: YAG laser device generates optical breakdown at nano-structured target materials. Extensive scientific investigations of different types of nanomaterial explore dependencies on nanoparticle size, laser wavelength and fluence, and time delay to obtain stronger signals from nano-material than from corresponding solid bulk matter. Modelling of the measurements interprets the occurrence of enhanced detectability of atomic species. Opportunities present themselves for biological and spectrochemical synthesis.
- 6 September 2018
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 21 (1) , 015502
Plasma ignition threshold disparity between silver nanoparticle-based target and bulk silver target at different laser wavelengths
Plasma ignition threshold of nanoparticles-based and bulk silver targets was measured in air. The plasma was initiated by Nd:YAG laser at wavelengths of 355, 532 and 1064 nm. The plasma ignition was monitored utilizing the prominent Ag I line at 546.5 nm. Lower ignition thresholds of nanoparticles-based silver target were estimated at 0.4±0.02, 0.34±0.04 and 0.27±0.035 J/cm2 coupled with the different laser wavelengths, respectively. In contrast, the bulk silver-target plasma exhibited an order of magnitude higher ignition threshold. Three orders of magnitude enhanced emission intensity from the nano-based target over bulk target was achieved at lower levels of laser irradiation. A reduction of the thermal diffusion length of the nano silver was assumed in order to theoretically predict this reduction in plasma threshold. In addition, the effect of self-reversal on the resonance lines is taken into consideration.
- 6 September 2018
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 21 (1) , 015502
Plasma ignition threshold disparity between silver nanoparticle-based target and bulk silver target at different laser wavelengths
Plasma ignition threshold of nanoparticles-based and bulk silver targets was measured in air. The plasma was initiated by Nd:YAG laser at wavelengths of 355, 532 and 1064 nm. The plasma ignition was monitored utilizing the prominent Ag I line at 546.5 nm. Lower ignition thresholds of nanoparticles-based silver target were estimated at 0.4±0.02, 0.34±0.04 and 0.27±0.035 J/cm2 coupled with the different laser wavelengths, respectively. In contrast, the bulk silver-target plasma exhibited an order of magnitude higher ignition threshold. Three orders of magnitude enhanced emission intensity from the nano-based target over bulk target was achieved at lower levels of laser irradiation. A reduction of the thermal diffusion length of the nano silver was assumed in order to theoretically predict this reduction in plasma threshold. In addition, the effect of self-reversal on the resonance lines is taken into consideration.