Jalal Nazarzadeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jalal Nazarzadeh has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
M. Razzaghi
4 shared publicationsJawad Faiz
$^{2}$Center of Excellence on Applied Electromagnetic Systems, School of Electrical and Computer Engineering University of Tehran Tehran Iran
3 shared publicationsK.Y. Nikravesh
Electrical Engineering, Amirkabir University of Technology, Tehran, Iran
3 shared publicationsMahdi Asefi
3 shared publicationsMohammad Javad Jafarian
Department of Electrical Engineering Faculty Engineering Shahed University Tehran Iran
3 shared publicationsMojtaba Babaei
Department of Electrical Engineering, Science and Research Branch , Islamic Azad University , Tehran, Iran
3 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 18 (1)
Improved Modulation Technique in Cascaded H‐Bridge Inverters for Fault‐Tolerant With Full Bridge Single Phase Rectifier Structure
This paper presents a novel fault‐tolerant approach for cascaded H‐bridge inverters with a full‐bridge single‐phase rectifier cell structure. Upon a fault, the faulty cell is disconnected from the circuit, and the inverter switches from normal operation (symmetric mode) to faulted operation (asymmetric mode). In asymmetric mode, one of the full‐bridge single‐phase rectifier cells in the faulty phase transitions from a full‐bridge to a half‐bridge configuration. The level‐shift pulse‐width modulation (PWM) is employed during symmetric mode, while a modified level‐shift PWM is utilized in asymmetric mode. The inverter's output power and voltage remain unchanged during faults in the modified PWM method. Additionally, the performance of the proposed fault‐tolerant algorithm is evaluated and validated using results from simulations and an experimental prototype of a seven‐level inverter.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 18 (1)
Open AccessImproved Modulation Technique in Cascaded H‐Bridge Inverters for Fault‐Tolerant With Full Bridge Single Phase Rectifier Structure
This paper presents a novel fault‐tolerant approach for cascaded H‐bridge inverters with a full‐bridge single‐phase rectifier cell structure. Upon a fault, the faulty cell is disconnected from the circuit, and the inverter switches from normal operation (symmetric mode) to faulted operation (asymmetric mode). In asymmetric mode, one of the full‐bridge single‐phase rectifier cells in the faulty phase transitions from a full‐bridge to a half‐bridge configuration. The level‐shift pulse‐width modulation (PWM) is employed during symmetric mode, while a modified level‐shift PWM is utilized in asymmetric mode. The inverter's output power and voltage remain unchanged during faults in the modified PWM method. Additionally, the performance of the proposed fault‐tolerant algorithm is evaluated and validated using results from simulations and an experimental prototype of a seven‐level inverter.
- Open Access
- 8 July 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (11) , 1711-1722
On the optimal game control in the DC microgrid systems
This paper introduces static and dynamic competitive optimal control of DC/DC converters in DC microgrids based on game theory considering mutual effects. Using static and dynamic game theories, the conditions for competitive optimal control of DC/DC converters in Nash equilibrium with static and dynamic states are determined. Also, to reduce the complexity in the design of competitive optimal control of DC/DC converters due to the bilinear dynamic model of the system, generalized objective functions are considered. The competitive optimal controls using the Lyapunov and Riccati equations are determined to track the system trajectory to Nash equilibrium. Also, the numerical and experimental results are presented and compared in several cases. The results show that the competitive optimal control of the DC/DC converters in the DC microgrids can effectively improve the performance of the system.
- 8 July 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (11) , 1711-1722
Open AccessOn the optimal game control in the DC microgrid systems
This paper introduces static and dynamic competitive optimal control of DC/DC converters in DC microgrids based on game theory considering mutual effects. Using static and dynamic game theories, the conditions for competitive optimal control of DC/DC converters in Nash equilibrium with static and dynamic states are determined. Also, to reduce the complexity in the design of competitive optimal control of DC/DC converters due to the bilinear dynamic model of the system, generalized objective functions are considered. The competitive optimal controls using the Lyapunov and Riccati equations are determined to track the system trajectory to Nash equilibrium. Also, the numerical and experimental results are presented and compared in several cases. The results show that the competitive optimal control of the DC/DC converters in the DC microgrids can effectively improve the performance of the system.
- 21 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (6) , 7029-7036
On the Minimum Time Tracking Control of the Active Front End Converters
This paper introduces the minimum time tracking control of an Active Front End (AFE) converter with excellent transient performance. Since the dynamical model of the AFE converter is a bilinear system, switching control is provided for minimum time tracking with final time-varying trajectories in this system. Due to the complexity of implementing this controller, a suboptimal closed-loop controller is proposed whose dynamic performance is very close to the minimum time tracking control. Simulation and experimental results show that the suboptimal proposed controller has excellent dynamic performance against load disturbances compared to the conventional control methods.
- 21 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 10 (6) , 7029-7036
On the Minimum Time Tracking Control of the Active Front End Converters
This paper introduces the minimum time tracking control of an Active Front End (AFE) converter with excellent transient performance. Since the dynamical model of the AFE converter is a bilinear system, switching control is provided for minimum time tracking with final time-varying trajectories in this system. Due to the complexity of implementing this controller, a suboptimal closed-loop controller is proposed whose dynamic performance is very close to the minimum time tracking control. Simulation and experimental results show that the suboptimal proposed controller has excellent dynamic performance against load disturbances compared to the conventional control methods.
- Open Access
- 7 May 2020
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (8) , 1359-1367
Optimal tracking control for asymmetrical fault ride through in the back‐to‐back converters
Asymmetrical faults in the grid cause oscillations in dc‐link capacitor voltage or overcurrent in the converters. In this study, an optimal controller with a fixed structure is introduced based on the command generator tracker (CGT) to restrict the fault currents and increase stability performance under asymmetrical grid faults. For this purpose, first, the integrated dynamical model including grid‐connected converters and dc‐link voltage are introduced. Then, using the optimal control techniques, a CGT is designed to enhance the fault ride through performances. Next, the proposed controller is applied to the system including converter and dc‐link at the source side and the dynamic performances of the closed‐loop system under different fault conditions are determined. Finally, the simulation results are compared with the other conventional controllers and the dynamic performances of the proposed controller are evaluated. The results indicate that the proposed controller provides stability for the system and satisfies allowable constraints of converter current for different grid fault types such as voltage sags, asymmetrical and symmetrical faults.
- 7 May 2020
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (8) , 1359-1367
Open AccessOptimal tracking control for asymmetrical fault ride through in the back‐to‐back converters
Asymmetrical faults in the grid cause oscillations in dc‐link capacitor voltage or overcurrent in the converters. In this study, an optimal controller with a fixed structure is introduced based on the command generator tracker (CGT) to restrict the fault currents and increase stability performance under asymmetrical grid faults. For this purpose, first, the integrated dynamical model including grid‐connected converters and dc‐link voltage are introduced. Then, using the optimal control techniques, a CGT is designed to enhance the fault ride through performances. Next, the proposed controller is applied to the system including converter and dc‐link at the source side and the dynamic performances of the closed‐loop system under different fault conditions are determined. Finally, the simulation results are compared with the other conventional controllers and the dynamic performances of the proposed controller are evaluated. The results indicate that the proposed controller provides stability for the system and satisfies allowable constraints of converter current for different grid fault types such as voltage sags, asymmetrical and symmetrical faults.
- 6 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (10) , 8155-8163
A TDF Model in Induction Machines for Loose Bearing Diagnosis by Neutral Voltage
The bearing wear and looseness are significant failures in induction machines. For accurate recognition of the bearing faults, a new comprehensive modeling and analysis of induction machines with three degrees of freedom along with an effective method for loose bearing signature are presented in this paper. For these purposes, the electromagnetic radial force and rotating torques are determined and applied to Euler-Lagrange equations of an induction machine. Besides, to better identify the defective loose bearings, the spectral analysis of neutral voltage is utilized. Comparing the experimental results with the outcome of the numerical analysis validates the proposed model. The results show that the spectral analysis of the neutral voltage detects mechanical looseness with higher precision than the conventional techniques such as mechanical vibrations and stator currents.
- 6 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 67 (10) , 8155-8163
A TDF Model in Induction Machines for Loose Bearing Diagnosis by Neutral Voltage
The bearing wear and looseness are significant failures in induction machines. For accurate recognition of the bearing faults, a new comprehensive modeling and analysis of induction machines with three degrees of freedom along with an effective method for loose bearing signature are presented in this paper. For these purposes, the electromagnetic radial force and rotating torques are determined and applied to Euler-Lagrange equations of an induction machine. Besides, to better identify the defective loose bearings, the spectral analysis of neutral voltage is utilized. Comparing the experimental results with the outcome of the numerical analysis validates the proposed model. The results show that the spectral analysis of the neutral voltage detects mechanical looseness with higher precision than the conventional techniques such as mechanical vibrations and stator currents.
- Open Access
- 17 January 2019
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 13 (3) , 340-348
Spectral analysis for diagnosis of bearing defects in induction machine drives
In this study, the finite element method (FEM) is utilised for precise analysis and detection of the bearing faults in induction machine drives. For this purpose, the machine inductances in the presence of slots, teeth, and various bearing failures are obtained by FEM. In addition, the spectrum of the stator currents are analysed by employing the electrical model of the induction machine drives. Some experimental and numerical results are illustrated that the proposed model can consider small bearing failures in high‐noise environments and thus can be used for analysing and detecting bearing failures in induction machine drives.
- 17 January 2019
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 13 (3) , 340-348
Open AccessSpectral analysis for diagnosis of bearing defects in induction machine drives
In this study, the finite element method (FEM) is utilised for precise analysis and detection of the bearing faults in induction machine drives. For this purpose, the machine inductances in the presence of slots, teeth, and various bearing failures are obtained by FEM. In addition, the spectrum of the stator currents are analysed by employing the electrical model of the induction machine drives. Some experimental and numerical results are illustrated that the proposed model can consider small bearing failures in high‐noise environments and thus can be used for analysing and detecting bearing failures in induction machine drives.
- 4 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (5) , 1897-1904
A Fast Transient Model for Bearing Fault Analysis in Induction Machine Drives
- 4 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (5) , 1897-1904
A Fast Transient Model for Bearing Fault Analysis in Induction Machine Drives
- 22 November 2018
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2781
Applying optimal Nash‐Stackelberg game for load adjusting in DC microgrids
For the stable operation of a grid, the load regulation in the network with distributed generation resources and loads is very important. In this article, game theory (the Nash and Stackelberg equilibriums and their combination) is applied to adjust the loads and voltages of the system. The purpose method is implemented on a 9‐bus microgrid and the optimal solutions for the Nash and Stackelberg and combining equilibriums are determined and compared. The results indicate that the introduced method can create a competitive environment with consideration of the priorities of the loads for power and voltage regulations.
- 22 November 2018
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 29 (4) , e2781
Applying optimal Nash‐Stackelberg game for load adjusting in DC microgrids
For the stable operation of a grid, the load regulation in the network with distributed generation resources and loads is very important. In this article, game theory (the Nash and Stackelberg equilibriums and their combination) is applied to adjust the loads and voltages of the system. The purpose method is implemented on a 9‐bus microgrid and the optimal solutions for the Nash and Stackelberg and combining equilibriums are determined and compared. The results indicate that the introduced method can create a competitive environment with consideration of the priorities of the loads for power and voltage regulations.
- 1 October 2018
- Published by Elsevier in ISA Transactions
- Vol. 81, 306-317
Employing neutral-voltage spectrum for internal turn-to-turn fault detection in the induction machine drives
- 1 October 2018
- Published by Elsevier in ISA Transactions
- Vol. 81, 306-317
Employing neutral-voltage spectrum for internal turn-to-turn fault detection in the induction machine drives
- Open Access
- 1 August 2018
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 11 (9) , 1591-1602
Integral‐series Fourier analysis of chaotic PWM patterns for common mode voltage stresses
In this study, the theory of pulse width modulation (PWM) is developed for both sine‐wave PWM (SPWM) and chaotic sine‐wave PWM (CSPWM). In SPWM, power spectra are analysed by an analytical method such as double Fourier series (DFS) technique, and the integral‐series Fourier method is fully devised and analytically theorised for CSPWM. It is shown that the root‐mean‐square value of inverter's zero‐sequence voltage does not rely on carrier and reference frequency in fixed‐frequency SPWM, while in CSPWM, this depends on frequency modulating gain and chaotic sequence of numbers. Also, the computation time of purely numerical harmonic analysis can be much heavier than analytical ones. Furthermore, the DFS and integral‐series Fourier methods are applied to SPWM and CSPWM with two different frame sizes of squirrel cage motors for the shaft voltage and the electro‐magnetic interference (EMI). The numerical and experimental results show that CSPWM can have positive effect on the shaft voltage while it definitely weakens the EMI problems.
- 1 August 2018
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 11 (9) , 1591-1602
Open AccessIntegral‐series Fourier analysis of chaotic PWM patterns for common mode voltage stresses
In this study, the theory of pulse width modulation (PWM) is developed for both sine‐wave PWM (SPWM) and chaotic sine‐wave PWM (CSPWM). In SPWM, power spectra are analysed by an analytical method such as double Fourier series (DFS) technique, and the integral‐series Fourier method is fully devised and analytically theorised for CSPWM. It is shown that the root‐mean‐square value of inverter's zero‐sequence voltage does not rely on carrier and reference frequency in fixed‐frequency SPWM, while in CSPWM, this depends on frequency modulating gain and chaotic sequence of numbers. Also, the computation time of purely numerical harmonic analysis can be much heavier than analytical ones. Furthermore, the DFS and integral‐series Fourier methods are applied to SPWM and CSPWM with two different frame sizes of squirrel cage motors for the shaft voltage and the electro‐magnetic interference (EMI). The numerical and experimental results show that CSPWM can have positive effect on the shaft voltage while it definitely weakens the EMI problems.