Kishor Thakre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kishor Thakre has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Aditi Chatterjee
Department of Electrical Engineering, Indira Gandhi Institute of Technology Sarang, India
2 shared publicationsKanungo Barada Mohanty
National Institute of Technology Rourkela
2 shared publications- Abhijit Bhowmick
Department of Communication Engineering, SENSE, Vellore Institute of Technology, Vellore, Tamil Nadu, India
1 shared publication Aditi Chaterjee
CV Raman Global University
1 shared publication- Husna Khouser G
Department of Electronics and Communication Engineering, SNS College of Technology (SNSCT), Coimbatore, India
1 shared publication - Kanungo Barada Mohanty
Department of Electrical Engineering, National Institute of Technology, Rourkela, India
1 shared publication
Latest Publications
- Open Access
- 29 June 2026
- Published by ECTI in ECTI Transactions on Electrical Engineering, Electronics, and Communications
- Vol. 24 (2)
Efficiency Evaluation of Boost and LLC Resonant Converters for Solar Water Pumping Applications
This paper investigates the feasibility of employing an LLC resonant converter in a high-efficiency Solar Water Pumping System (SWPS) as an alternative to the conventional boost converter stage. The proposed system integrates maximum power point tracking (MPPT), PI-based DC-link regulation, and V/f control of an induction motor to maintain optimal performance under varying solar irradiance conditions. A detailed MATLAB/Simulink model was developed and experimentally validated using an OPAL-RT 4510 hardware-in-the-loop (HIL) platform. The LLC converter operates at 10 kHz, while the motor frequency is varied between 0–50 Hz to track irradiance-dependent reference speeds. Stagewise power flow analysis was conducted at irradiance levels of 1000, 500, and 300 W/m², comparing both boost and LLC topologies. Results indicate that the motor effectively follows the reference speed without overcurrent, and the LLC-based configuration achieves soft switching with a modest efficiency improvement from 85.6% to 87.0% over the conventional boost design. While the LLC approach may involve higher component costs, the study demonstrates its potential to enhance energy conversion efficiency, reduce switching losses, and improve operational reliability, providing insights into next-generation solar pumping solutions.
- 29 June 2026
- Published by ECTI in ECTI Transactions on Electrical Engineering, Electronics, and Communications
- Vol. 24 (2)
Open AccessEfficiency Evaluation of Boost and LLC Resonant Converters for Solar Water Pumping Applications
This paper investigates the feasibility of employing an LLC resonant converter in a high-efficiency Solar Water Pumping System (SWPS) as an alternative to the conventional boost converter stage. The proposed system integrates maximum power point tracking (MPPT), PI-based DC-link regulation, and V/f control of an induction motor to maintain optimal performance under varying solar irradiance conditions. A detailed MATLAB/Simulink model was developed and experimentally validated using an OPAL-RT 4510 hardware-in-the-loop (HIL) platform. The LLC converter operates at 10 kHz, while the motor frequency is varied between 0–50 Hz to track irradiance-dependent reference speeds. Stagewise power flow analysis was conducted at irradiance levels of 1000, 500, and 300 W/m², comparing both boost and LLC topologies. Results indicate that the motor effectively follows the reference speed without overcurrent, and the LLC-based configuration achieves soft switching with a modest efficiency improvement from 85.6% to 87.0% over the conventional boost design. While the LLC approach may involve higher component costs, the study demonstrates its potential to enhance energy conversion efficiency, reduce switching losses, and improve operational reliability, providing insights into next-generation solar pumping solutions.
- 2 March 2026
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 107 (3) , 1029-1041
Evolution of Control Architectures and Applications of DVR in Modern Distribution Systems: A Comprehensive Review
- 2 March 2026
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 107 (3) , 1029-1041
Evolution of Control Architectures and Applications of DVR in Modern Distribution Systems: A Comprehensive Review
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 13 (4) , 798-807
Minimization of the circuit components with modified cascaded multilevel inverter topology
This article examines a modified multilevel inverter circuit that uses basic units connected in cascade. The suggested circuit can be used with an inverter that is symmetrical or asymmetric. The magnitude of the DC voltage source is determined using a variety of methods in order to generate a large number of voltage levels. For both symmetrical and asymmetrical configurations, the magnitude of two DC sources in basic units can be used. The DC voltage source's magnitude is the same for each unit in the symmetrical configuration. However, in an asymmetrical configuration, the value of the DC source for the fundamental units is inequitable, and their magnitudes are obtained using various techniques. Comparison study demonstrates that the suggested circuit requires minimum components, reduces power loss, and boosts inverter efficiency. Additionally, in comparison to modern topologies, the standing voltage across the switches is acceptable. To verify the effectiveness of the investigated topology, simulation results for 15, 17, 23, and 31-level inverters are analysed.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 13 (4) , 798-807
Open AccessMinimization of the circuit components with modified cascaded multilevel inverter topology
This article examines a modified multilevel inverter circuit that uses basic units connected in cascade. The suggested circuit can be used with an inverter that is symmetrical or asymmetric. The magnitude of the DC voltage source is determined using a variety of methods in order to generate a large number of voltage levels. For both symmetrical and asymmetrical configurations, the magnitude of two DC sources in basic units can be used. The DC voltage source's magnitude is the same for each unit in the symmetrical configuration. However, in an asymmetrical configuration, the value of the DC source for the fundamental units is inequitable, and their magnitudes are obtained using various techniques. Comparison study demonstrates that the suggested circuit requires minimum components, reduces power loss, and boosts inverter efficiency. Additionally, in comparison to modern topologies, the standing voltage across the switches is acceptable. To verify the effectiveness of the investigated topology, simulation results for 15, 17, 23, and 31-level inverters are analysed.
- 27 March 2023
- Published by Taylor & Francis in International Journal of Modelling and Simulation
- Vol. 45 (1) , 237-244
Modular three phase asymmetrical cascaded multilevel inverter with lower number of switches
This paper introduces a modular circuit for three-phase asymmetrical multilevel inverter, which is composed of series basic unit cells. It requires fewer number of switches as compared to conventional MLI circuits. Carrier-based pulse width modulation scheme is used to generate switching pulses circuit switches. The proposed circuit is compared with conventional MLI circuit. In order to verify the superiority of proposed circuit, a single phase 4-level inverter and three phase 7-level inverter are simulated in MATLAB/Simulink environment and hardware porotype is also demonstrated using dSPACE 1104 real-time controller.
- 27 March 2023
- Published by Taylor & Francis in International Journal of Modelling and Simulation
- Vol. 45 (1) , 237-244
Modular three phase asymmetrical cascaded multilevel inverter with lower number of switches
This paper introduces a modular circuit for three-phase asymmetrical multilevel inverter, which is composed of series basic unit cells. It requires fewer number of switches as compared to conventional MLI circuits. Carrier-based pulse width modulation scheme is used to generate switching pulses circuit switches. The proposed circuit is compared with conventional MLI circuit. In order to verify the superiority of proposed circuit, a single phase 4-level inverter and three phase 7-level inverter are simulated in MATLAB/Simulink environment and hardware porotype is also demonstrated using dSPACE 1104 real-time controller.
- 22 April 2021
- Published by Springer Nature
- p. 133-145
Trapezoidal Triangular Carrier-Based PWM Scheme for Performance Enhanced in Multilevel Inverter
- 22 April 2021
- Published by Springer Nature
- p. 133-145
Trapezoidal Triangular Carrier-Based PWM Scheme for Performance Enhanced in Multilevel Inverter
- 15 February 2020
- Published by Taylor & Francis in EPE Journal
- Vol. 30 (2) , 69-79
Modelling and Simulation of an Asymmetrical Modular Multilevel Inverter with Less Number of Components
This paper presents a modified topology for asymmetric modular multilevel inverter as a fundamental block. It consists of eight switches (including six bidirectional-conducting unidirectional-blocking switches and two bidirectional-conducting bidirectional-blocking switches) and four DC sources with unequal magnitudes, which generates 13-level output voltage. The proposed topology offers special features such as reduced number of switches, isolated DC sources, economical and less complexity with modular structure as compared to other contemporary topologies. Moreover, significant reduction in switch voltage can be achieved. The comparative study of proposed topologies with the conventional and recent topologies have been presented in terms of power switches, gate drivers, isolated DC voltage sources and total standing voltage on the switches. A multicarrier-based sinusoidal pulse width modulation scheme is adopted for generating the gate pulses using real-time simulation with dSPACE DS 1104. The proposed topology offers a fewer number of ON-state switches which lead to the reduction in power loss. The feasibility of proposed multilevel inverter, the simulation and experimental results are analysed under steady state and dynamic states.
- 15 February 2020
- Published by Taylor & Francis in EPE Journal
- Vol. 30 (2) , 69-79
Modelling and Simulation of an Asymmetrical Modular Multilevel Inverter with Less Number of Components
This paper presents a modified topology for asymmetric modular multilevel inverter as a fundamental block. It consists of eight switches (including six bidirectional-conducting unidirectional-blocking switches and two bidirectional-conducting bidirectional-blocking switches) and four DC sources with unequal magnitudes, which generates 13-level output voltage. The proposed topology offers special features such as reduced number of switches, isolated DC sources, economical and less complexity with modular structure as compared to other contemporary topologies. Moreover, significant reduction in switch voltage can be achieved. The comparative study of proposed topologies with the conventional and recent topologies have been presented in terms of power switches, gate drivers, isolated DC voltage sources and total standing voltage on the switches. A multicarrier-based sinusoidal pulse width modulation scheme is adopted for generating the gate pulses using real-time simulation with dSPACE DS 1104. The proposed topology offers a fewer number of ON-state switches which lead to the reduction in power loss. The feasibility of proposed multilevel inverter, the simulation and experimental results are analysed under steady state and dynamic states.
- 27 March 2019
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (6)
A modified circuit for symmetric and asymmetric multilevel inverter with reduced components count
- 27 March 2019
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 29 (6)
A modified circuit for symmetric and asymmetric multilevel inverter with reduced components count