Suneil Kumar Aggarwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Suneil Kumar Aggarwal has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
Vijay Sai
7 shared publicationsV. Ramnath Iyer
Department of Cardiology, Sri Sathya Sai Institute of Higher Medical Sciences, Prashantigram, AP, India
5 shared publicationsV Ramnath Iyer
4 shared publicationsJitendra Mishra
3 shared publicationsMichael J Mullen
Barts Heart Centre, St Bartholomew’s Hospital, London, UK
3 shared publicationsMichael J. Mullen
Cardiology Department Barts Heart Centre, St Bartholomew's Hospital London UK
3 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Double Transeptal Puncture for SAPIEN M3 Transcatheter Mitral Valve Replacement: Initial Experience, Indications, and Technique
The SAPIEN M3 system has been recently approved for transcatheter mitral valve replacement (TMVR). The transeptal guide sheath is used to deploy the dock, which is completely released before inserting and deploying the M3 valve using the same femoral access, transeptal puncture (TSP) and guide sheath. However, clinical scenarios such us low dock position or small left ventricular outflow tract (LVOT) may require to deploy the M3 valve with a second guide sheath while the dock is still attached to the first. In this article, we describe our initial experience with the “double transeptal technique” in two patients, focusing on indications and key technical points.
- 1 October 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
Open AccessDouble Transeptal Puncture for SAPIEN M3 Transcatheter Mitral Valve Replacement: Initial Experience, Indications, and Technique
The SAPIEN M3 system has been recently approved for transcatheter mitral valve replacement (TMVR). The transeptal guide sheath is used to deploy the dock, which is completely released before inserting and deploying the M3 valve using the same femoral access, transeptal puncture (TSP) and guide sheath. However, clinical scenarios such us low dock position or small left ventricular outflow tract (LVOT) may require to deploy the M3 valve with a second guide sheath while the dock is still attached to the first. In this article, we describe our initial experience with the “double transeptal technique” in two patients, focusing on indications and key technical points.
- 15 June 2026
- Published by Elsevier in Clinical Oncology
- Vol. 56, 104195
The Application of AI in Cancer MDT and its Legal Implication
- 15 June 2026
- Published by Elsevier in Clinical Oncology
- Vol. 56, 104195
The Application of AI in Cancer MDT and its Legal Implication
- Open Access
- 22 April 2026
- Published by Queen's University Library in POCUS Journal
- Vol. 11 (01) , 27-29
Utilizing Cardiac POCUS for the Diagnosis of Dynamic Mitral Regurgitation
We report a case of an elderly gentleman with recurrent episodes of flash pulmonary edema, initially attributed to hypertensive episodes. Cardiac point of care ultrasound (POCUS) revealed severe mitral regurgitation (MR), a finding underappreciated on transthoracic echocardiography and likely responsible for his repeated episodes of deterioration. Early recognition of dynamic MR expedited and guided targeted management of his valvular pathology. This case report highlights how serial cardiac POCUS can complement transthoracic echocardiography.
- 22 April 2026
- Published by Queen's University Library in POCUS Journal
- Vol. 11 (01) , 27-29
Open AccessUtilizing Cardiac POCUS for the Diagnosis of Dynamic Mitral Regurgitation
We report a case of an elderly gentleman with recurrent episodes of flash pulmonary edema, initially attributed to hypertensive episodes. Cardiac point of care ultrasound (POCUS) revealed severe mitral regurgitation (MR), a finding underappreciated on transthoracic echocardiography and likely responsible for his repeated episodes of deterioration. Early recognition of dynamic MR expedited and guided targeted management of his valvular pathology. This case report highlights how serial cardiac POCUS can complement transthoracic echocardiography.
- Open Access
- 18 February 2025
- Published by Radcliffe Medical Media Ltd in Interventional Cardiology: Reviews, Research, Resources
- Vol. 20, e04
Patent Foramen Ovale Closure: British Cardiovascular Intervention Society Position Statement
The foramen ovale is a flap in the atrial septum that is open in the fetus to allow oxygenated blood returning from the placenta to pass to the systemic circulation. In early life, the primum septal flap should close, but in 25% of people the flap does not seal fully. Most patent foramen ovale (PFO) are small and open only following Valsalva. Resting right-to-left shunts are less common, occurring in 5% of individuals. This British Cardiovascular Intervention Society position statement describes the diagnosis, indications and procedure for PFO closure.
- 18 February 2025
- Published by Radcliffe Medical Media Ltd in Interventional Cardiology: Reviews, Research, Resources
- Vol. 20, e04
Open AccessPatent Foramen Ovale Closure: British Cardiovascular Intervention Society Position Statement
The foramen ovale is a flap in the atrial septum that is open in the fetus to allow oxygenated blood returning from the placenta to pass to the systemic circulation. In early life, the primum septal flap should close, but in 25% of people the flap does not seal fully. Most patent foramen ovale (PFO) are small and open only following Valsalva. Resting right-to-left shunts are less common, occurring in 5% of individuals. This British Cardiovascular Intervention Society position statement describes the diagnosis, indications and procedure for PFO closure.
- 13 June 2018
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 31 (5) , 648-654
Patterns of solid particle embolization during transcatheter aortic valve implantation and correlation with aortic valve calcification
Objectives: To evaluate solid embolization during transcatheter aortic valve implantation (TAVI) and correlate this with aortic valve calcification.Background: There is a known stroke risk with TAVI, thought partly to be due to dislodgement of native aortic valve particles during implantation. However, to date there is little evidence that aortic valve calcification actually impacts embolic risk.Methods: Transcranial Doppler (TCD) was performed on consecutive suitable patients undergoing TAVI, using hardware and software enabling differentiation between solid and gaseous emboli. Data was analyzed by time points during the TAVI procedure. These results were correlated with aortic valve calcification.Results: TCD was successfully performed on 63 patients. The median number of solid emboli was 76.0. The most common time point for solid embolization was during valve positioning. Forty‐five of these patients had an appropriate CT scan which could be analyzed for an Agatston calcium score. The mean scores in the aortic valve and aortic root were 3382.4 and 754.9. There were significant correlations between the total number of solid emboli and valve calcium score (P = 0.033) and solid emboli during valve positioning and valve calcium score (P = 0.035). There was no relationship between gaseous emboli and valve calcium score.Conclusions: TAVI is associated with significant solid particle embolization, with the most common time point being during valve positioning. Solid embolization correlates with aortic valve calcium score, suggesting that valve calcification is a factor in embolic risk. This should be taken into consideration along with other clinical factors when assessing embolic risk.
- 13 June 2018
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 31 (5) , 648-654
Patterns of solid particle embolization during transcatheter aortic valve implantation and correlation with aortic valve calcification
Objectives: To evaluate solid embolization during transcatheter aortic valve implantation (TAVI) and correlate this with aortic valve calcification.Background: There is a known stroke risk with TAVI, thought partly to be due to dislodgement of native aortic valve particles during implantation. However, to date there is little evidence that aortic valve calcification actually impacts embolic risk.Methods: Transcranial Doppler (TCD) was performed on consecutive suitable patients undergoing TAVI, using hardware and software enabling differentiation between solid and gaseous emboli. Data was analyzed by time points during the TAVI procedure. These results were correlated with aortic valve calcification.Results: TCD was successfully performed on 63 patients. The median number of solid emboli was 76.0. The most common time point for solid embolization was during valve positioning. Forty‐five of these patients had an appropriate CT scan which could be analyzed for an Agatston calcium score. The mean scores in the aortic valve and aortic root were 3382.4 and 754.9. There were significant correlations between the total number of solid emboli and valve calcium score (P = 0.033) and solid emboli during valve positioning and valve calcium score (P = 0.035). There was no relationship between gaseous emboli and valve calcium score.Conclusions: TAVI is associated with significant solid particle embolization, with the most common time point being during valve positioning. Solid embolization correlates with aortic valve calcium score, suggesting that valve calcification is a factor in embolic risk. This should be taken into consideration along with other clinical factors when assessing embolic risk.
- 1 June 2016
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 29 (3) , 319-324
Balloon‐Expandable Transcatheter Aortic Valves Can Be Successfully and Safely Implanted Transfemorally Without Balloon Valvuloplasty
TAVI can be effectively and safely performed without a BAV and this results in reduced procedural and fluoroscopic times, although embolization to the brain is not reduced. There is a trend toward reduced stroke risk. (J Interven Cardiol 2016;29:319-324).
- 1 June 2016
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 29 (3) , 319-324
Balloon‐Expandable Transcatheter Aortic Valves Can Be Successfully and Safely Implanted Transfemorally Without Balloon Valvuloplasty
TAVI can be effectively and safely performed without a BAV and this results in reduced procedural and fluoroscopic times, although embolization to the brain is not reduced. There is a trend toward reduced stroke risk. (J Interven Cardiol 2016;29:319-324).
- 1 September 2015
- Vol. 27 (9) , E190-5
Closure of Long-Tunnel PFOs With the Coherex Flatstent EF - A Tailored Approach.
Despite rapid progress in device technologies for patent foramen ovale (PFO) closure over the past decade, long-tunnel anatomies still constitute a challenge. The present study investigated the performance of a novel in-tunnel device (Flatstent EF; Coherex Medical) in long-tunnel PFOs. Three different umbrella devices (n = 61) and the Coherex Flatstent (n = 27) were used for PFO closure. The Flatstent was the preferred device in long-tunnel anatomies. Seven patients with long PFO tunnels underwent "detunnelization" by stepwise inflation of a low-pressure balloon followed by implantation of an umbrella device. Complete occlusion or trivial residual shunting ("clinical" occlusion) was achieved in 93% of the Flatstent and 92% of the umbrella device procedures (P=.92). Device performance in long-tunnel anatomies was in favor of the Flatstent (n = 24) compared with conventional occluders (n = 7), with "clinical" occlusion of 96% vs 86% (P=.24) and procedure time of 44 ± 16 minutes vs 59 ± 21 minutes (P=.04). Furthermore, postprocedural arrhythmias were significantly less frequent after Flatstent implantations (0.0% vs 9.1%; P=.03). In long-tunnel PFOs, the Flatstent device was quicker to deploy, was at least as equally efficacious as umbrella devices, and reduced the incidence of symptomatic arrhythmias following PFO closure.
- 1 September 2015
- Vol. 27 (9) , E190-5
Closure of Long-Tunnel PFOs With the Coherex Flatstent EF - A Tailored Approach.
Despite rapid progress in device technologies for patent foramen ovale (PFO) closure over the past decade, long-tunnel anatomies still constitute a challenge. The present study investigated the performance of a novel in-tunnel device (Flatstent EF; Coherex Medical) in long-tunnel PFOs. Three different umbrella devices (n = 61) and the Coherex Flatstent (n = 27) were used for PFO closure. The Flatstent was the preferred device in long-tunnel anatomies. Seven patients with long PFO tunnels underwent "detunnelization" by stepwise inflation of a low-pressure balloon followed by implantation of an umbrella device. Complete occlusion or trivial residual shunting ("clinical" occlusion) was achieved in 93% of the Flatstent and 92% of the umbrella device procedures (P=.92). Device performance in long-tunnel anatomies was in favor of the Flatstent (n = 24) compared with conventional occluders (n = 7), with "clinical" occlusion of 96% vs 86% (P=.24) and procedure time of 44 ± 16 minutes vs 59 ± 21 minutes (P=.04). Furthermore, postprocedural arrhythmias were significantly less frequent after Flatstent implantations (0.0% vs 9.1%; P=.03). In long-tunnel PFOs, the Flatstent device was quicker to deploy, was at least as equally efficacious as umbrella devices, and reduced the incidence of symptomatic arrhythmias following PFO closure.
- 1 November 2014
- Vol. 23 (6) , 675-82
Post-procedural arterial hypertension: implications for clinical outcome after transcatheter aortic valve implantation.
Persistent arterial hypertension (HT) has been associated with increased morbidity and mortality after surgical aortic valve replacement (AVR). The impact of increased blood pressure (BP) after transcatheter aortic valve implantation (TAVI) has not yet been fully elucidated. The mean systolic and diastolic BP after TAVI were calculated from the last 10 non-invasive recordings performed before discharge in 176 patients. The primary end-point was symptomatic improvement after 6-12 months according to BP control at the time of discharge. In patients with controlled BP ( or =140/90 mmHg), as reflected by NYHA functional class (+1.4 +/- 0.8 versus +0.8 +/- 1.0, p = 0.002) and six-minute walk test (6-MWT) distance improvement (+100 +/- 71 m versus +30 +/- 64 m, p < 0.001) at 6-12 months' follow up. A 10 mmHg decrease in systolic BP was associated with an 18 m increase in 6-MWT distance (p = 0.001). In addition, reverse left ventricular (LV) remodeling was significantly impaired in uncontrolled BP individuals, as reflected by regression of LV mass (-15 +/- 61 g versus -37 +/- 54 g, p = 0.041) and relative wall thickness (-0.02 +/- 0.09 versus -0.07 +/- 0.1, p = 0.01). Cumulative all-cause and cardiovascular mortality were significantly lower in patients with controlled BP compared to those with uncontrolled BP (6.5% versus 16%, p = 0.04; cardiovascular 3.7% versus 11.6%, p = 0.035). Uncontrolled HT after TAVI may contribute to diminished symptomatic improvement.
- 1 November 2014
- Vol. 23 (6) , 675-82
Post-procedural arterial hypertension: implications for clinical outcome after transcatheter aortic valve implantation.
Persistent arterial hypertension (HT) has been associated with increased morbidity and mortality after surgical aortic valve replacement (AVR). The impact of increased blood pressure (BP) after transcatheter aortic valve implantation (TAVI) has not yet been fully elucidated. The mean systolic and diastolic BP after TAVI were calculated from the last 10 non-invasive recordings performed before discharge in 176 patients. The primary end-point was symptomatic improvement after 6-12 months according to BP control at the time of discharge. In patients with controlled BP ( or =140/90 mmHg), as reflected by NYHA functional class (+1.4 +/- 0.8 versus +0.8 +/- 1.0, p = 0.002) and six-minute walk test (6-MWT) distance improvement (+100 +/- 71 m versus +30 +/- 64 m, p < 0.001) at 6-12 months' follow up. A 10 mmHg decrease in systolic BP was associated with an 18 m increase in 6-MWT distance (p = 0.001). In addition, reverse left ventricular (LV) remodeling was significantly impaired in uncontrolled BP individuals, as reflected by regression of LV mass (-15 +/- 61 g versus -37 +/- 54 g, p = 0.041) and relative wall thickness (-0.02 +/- 0.09 versus -0.07 +/- 0.1, p = 0.01). Cumulative all-cause and cardiovascular mortality were significantly lower in patients with controlled BP compared to those with uncontrolled BP (6.5% versus 16%, p = 0.04; cardiovascular 3.7% versus 11.6%, p = 0.035). Uncontrolled HT after TAVI may contribute to diminished symptomatic improvement.
- 1 September 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 176 (2) , 437-443
Serum albumin changes and multivariate dynamic risk modelling in chronic heart failure
- 1 September 2014
- Published by Elsevier in International Journal of Cardiology
- Vol. 176 (2) , 437-443
Serum albumin changes and multivariate dynamic risk modelling in chronic heart failure
- 1 August 2014
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 7 (8) , e97-e98
Seeing Through the Haze
- 1 August 2014
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 7 (8) , e97-e98
Seeing Through the Haze