Won Jo Cheong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Won Jo Cheong has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Faiz Ali
Department of Chemistry, University of Malakand, KPK, Pakistan
12 shared publicationsYune Sung Kim
Department of Chemistry, Inha University, Incheon, South Korea
10 shared publicationsGenlin Sun
Department of Chemistry, Inha University, Incheon, South Korea
7 shared publicationsJeong Soo Kim
Department of Chemistry, Inha University, Incheon, South Korea
7 shared publicationsShabi Abbas Zaidi
7 shared publications- Ashraf Ali
The University of Haripur
5 shared publications
Latest Publications
- 13 August 2025
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 27 (8) , 1-17
Silica-incorporated molecularly imprinted polymers for removal of acid black ATT via solid-phase extraction
- 13 August 2025
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 27 (8) , 1-17
Silica-incorporated molecularly imprinted polymers for removal of acid black ATT via solid-phase extraction
- 25 January 2021
- Published by Wiley in Journal of Separation Science
- Vol. 44 (7) , 1430-1439
Particle packed mixed‐mode chromatographic stationary phase for the separation of peptide in liquid chromatography
A particle‐based stationary phase has been prepared for the separation of five synthetic peptides and a mixture containing tryptic digest of cytochrome C in liquid chromatography. Particles originating from silica monolith were differentially sedimented to obtain 1–2 μm particles. A stationary phase was achieved by the coating of poly(styrene‐methacrylic acid‐N‐phenylacrylamide) copolymer onto the particles via reversible addition‐fragmentation chain transfer polymerization reaction. Stainless steel column (30 cm long and 1 mm internal diameter) was packed with stationary phase. Very high separation efficiency (ca. 351 000 plates/m) was achieved for five commercial peptides with a percent relative standard deviation of less than 1%. Protocol for the synthesis and modification of silica monolith particles has been well optimized with a good reproducibility both in particle and pore size. The column resolved about 21 peptide components from a mixture containing tryptic digest of cytochrome C, under the elution conditions of acetonitrile/15 mM ammonium format (65/35 v/v%) with a flow rate of 28 μL/min.
- 25 January 2021
- Published by Wiley in Journal of Separation Science
- Vol. 44 (7) , 1430-1439
Particle packed mixed‐mode chromatographic stationary phase for the separation of peptide in liquid chromatography
A particle‐based stationary phase has been prepared for the separation of five synthetic peptides and a mixture containing tryptic digest of cytochrome C in liquid chromatography. Particles originating from silica monolith were differentially sedimented to obtain 1–2 μm particles. A stationary phase was achieved by the coating of poly(styrene‐methacrylic acid‐N‐phenylacrylamide) copolymer onto the particles via reversible addition‐fragmentation chain transfer polymerization reaction. Stainless steel column (30 cm long and 1 mm internal diameter) was packed with stationary phase. Very high separation efficiency (ca. 351 000 plates/m) was achieved for five commercial peptides with a percent relative standard deviation of less than 1%. Protocol for the synthesis and modification of silica monolith particles has been well optimized with a good reproducibility both in particle and pore size. The column resolved about 21 peptide components from a mixture containing tryptic digest of cytochrome C, under the elution conditions of acetonitrile/15 mM ammonium format (65/35 v/v%) with a flow rate of 28 μL/min.
- 18 January 2021
- Published by Springer Nature in Chromatographia
- Vol. 84 (3) , 257-266
Preparation and Evaluation of 2 m Long Open Tubular Capillary Columns of 50 μm Internal Diameter for Separation of Peptides in Liquid Chromatography
- 18 January 2021
- Published by Springer Nature in Chromatographia
- Vol. 84 (3) , 257-266
Preparation and Evaluation of 2 m Long Open Tubular Capillary Columns of 50 μm Internal Diameter for Separation of Peptides in Liquid Chromatography
- 21 April 2020
- Published by Springer Nature in Chromatographia
- Vol. 83 (6) , 739-748
Ground Organic Particles of ca. 3 μm Size as Chromatographic Separation Media in High Performance Liquid Chromatography
- 21 April 2020
- Published by Springer Nature in Chromatographia
- Vol. 83 (6) , 739-748
Ground Organic Particles of ca. 3 μm Size as Chromatographic Separation Media in High Performance Liquid Chromatography
- Open Access
- 1 March 2020
- Published by Akademiai Kiado Zrt. in Acta Chromatographica
- Vol. 32 (1) , 22-27
Fabrication of permanent silver cement frit at the inlet of micro-columns: a significant progress toward realization of disposable micro-columns
The advent of disposable micro-columns will be a hope of workers of chromatography-related laboratories. A very critical and important requirement is the formation of affordable inlet frits. Welding a metal screen to a column inlet is not recommended because of the risk of damage to stationary phase. In this study, the Tollens probe (silver mirror reaction) was adopted to make affordable frits. Silver is reduced on the particle surface and in an empty space among the particles, forming a solid silver network structure at the column inlet area by injecting the reaction solution into the packed column at a depth of one third (10 cm) of the packed bed (0.5 mm × 300 mm). The silver cement structure was successfully formed, and the silver cement frit endured mobile phase flow well when C18 modified ground silica monolith particles were used to make the packed bed. The formation of the silver cement frit was not successful when the stationary phase based on conventional spherical silica particles was used. Negligible reduction of chromatographic performance by the silver cemented frit was observed. This study serves as the first step toward realization of disposable micro-columns.
- 1 March 2020
- Published by Akademiai Kiado Zrt. in Acta Chromatographica
- Vol. 32 (1) , 22-27
Open AccessFabrication of permanent silver cement frit at the inlet of micro-columns: a significant progress toward realization of disposable micro-columns
The advent of disposable micro-columns will be a hope of workers of chromatography-related laboratories. A very critical and important requirement is the formation of affordable inlet frits. Welding a metal screen to a column inlet is not recommended because of the risk of damage to stationary phase. In this study, the Tollens probe (silver mirror reaction) was adopted to make affordable frits. Silver is reduced on the particle surface and in an empty space among the particles, forming a solid silver network structure at the column inlet area by injecting the reaction solution into the packed column at a depth of one third (10 cm) of the packed bed (0.5 mm × 300 mm). The silver cement structure was successfully formed, and the silver cement frit endured mobile phase flow well when C18 modified ground silica monolith particles were used to make the packed bed. The formation of the silver cement frit was not successful when the stationary phase based on conventional spherical silica particles was used. Negligible reduction of chromatographic performance by the silver cemented frit was observed. This study serves as the first step toward realization of disposable micro-columns.
- 7 January 2020
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 41 (2) , 241-244
Development of Ground Organic Monolith Particles as Packing Material in High Performance Liquid Chromatography
- 7 January 2020
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 41 (2) , 241-244
Development of Ground Organic Monolith Particles as Packing Material in High Performance Liquid Chromatography
- 15 December 2019
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 41 (1) , 96-99
Development of a New Solid Phase Extraction Cartridge Filled with Organic Monolith Particles for Extraction of di‐Alkyl Phthalates
- 15 December 2019
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 41 (1) , 96-99
Development of a New Solid Phase Extraction Cartridge Filled with Organic Monolith Particles for Extraction of di‐Alkyl Phthalates
- 6 October 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (24) , 3621-3630
An optimized mixed‐mode stationary phase based on silica monolith particles for the separation of peptides and proteins in high‐performance liquid chromatography
A phase with both hydrophobic and hydrophilic functionalities has been synthesized by modification of ground silica monolith particles with C18 and 1‐[3‐(trimethoxysilyl)propyl] urea ligands. A series of phases was prepared by changing the ratio of the two ligands to determine the optimal ratio in view of separation efficiency. The resultant optimized stationary phase was packed in narrow‐bore glass‐lined stainless‐steel columns (1 × 300 mm and 2.1 × 100 mm) and used for the separation of synthetic peptides and proteins. The average numbers of theoretical plates (N) of 52 100/column (174 000/m, 5.75 µm plate height) and 35 500/column (118 000/m, 8.47 µm plate height) were achieved with the 300 mm column at a flow rate of 25 µL/min (0.86 mm/s) in 60:40 v/v acetonitrile/30 mM aqueous ammonium formate for the mixture of peptides (Thr‐Tyr‐Ser, Val‐Ala‐Pro‐Gly, angiotensin I, isotocin, and bradykinin) and for the mixture of proteins (myoglobin, human serum albumin, and insulin), respectively. Fast analysis of the peptides and proteins was also carried out at a flow rate of 0.9 mL/min (6.88 mm/s) with the 100 mm column and all the analytes were eluted within 2 min with good separation efficiency.
- 6 October 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (24) , 3621-3630
An optimized mixed‐mode stationary phase based on silica monolith particles for the separation of peptides and proteins in high‐performance liquid chromatography
A phase with both hydrophobic and hydrophilic functionalities has been synthesized by modification of ground silica monolith particles with C18 and 1‐[3‐(trimethoxysilyl)propyl] urea ligands. A series of phases was prepared by changing the ratio of the two ligands to determine the optimal ratio in view of separation efficiency. The resultant optimized stationary phase was packed in narrow‐bore glass‐lined stainless‐steel columns (1 × 300 mm and 2.1 × 100 mm) and used for the separation of synthetic peptides and proteins. The average numbers of theoretical plates (N) of 52 100/column (174 000/m, 5.75 µm plate height) and 35 500/column (118 000/m, 8.47 µm plate height) were achieved with the 300 mm column at a flow rate of 25 µL/min (0.86 mm/s) in 60:40 v/v acetonitrile/30 mM aqueous ammonium formate for the mixture of peptides (Thr‐Tyr‐Ser, Val‐Ala‐Pro‐Gly, angiotensin I, isotocin, and bradykinin) and for the mixture of proteins (myoglobin, human serum albumin, and insulin), respectively. Fast analysis of the peptides and proteins was also carried out at a flow rate of 0.9 mL/min (6.88 mm/s) with the 100 mm column and all the analytes were eluted within 2 min with good separation efficiency.
- 24 September 2019
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 43 (1-2) , 66-73
100 Micrometer bore open tubular capillary column modified with linear co-polymer chains for application in low pressure liquid chromatography
The performance of a 100 um i.d. open tubular column modified with linear co-polymer chains has been explored under low pressure operating conditions. A 512 mm fused-silica capillary was reacted with 3-chloropropyl isocyanate followed by sodium diethyldithiocarbamate. A copolymer layer was then immobilized on the inner surface via reversible addition-fragmentation transfer polymerization of styrene, methacrylic acid and N-phenylacrylamide. The thickness of the polymer layer was ca 1.5 µm. The column was evaluated for the separation of a mixture composed of three peptides (Trp-Gly, angiotensin I, bradykinin). The number of theoretical plates (N) as high as 72,100 plates/column (corresponding to 140,800/m, 7.10 µm plate height) was achieved. The column to column and day to day reproducibility of our columns was found better than 2.1%. For comparison purpose, similar chromatographic data for a selected analyte was also obtained with a commercial microcolumn of 0.5 mm id packed with a conventional C18 phase (5 µm), and 17 µm was the plate height obtained at the optimum flow rate. The van Deemter plots and kinetic plots were also obtained for comparison between our open tubular capillary column and the commercial packed column of a narrow id.
- 24 September 2019
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 43 (1-2) , 66-73
100 Micrometer bore open tubular capillary column modified with linear co-polymer chains for application in low pressure liquid chromatography
The performance of a 100 um i.d. open tubular column modified with linear co-polymer chains has been explored under low pressure operating conditions. A 512 mm fused-silica capillary was reacted with 3-chloropropyl isocyanate followed by sodium diethyldithiocarbamate. A copolymer layer was then immobilized on the inner surface via reversible addition-fragmentation transfer polymerization of styrene, methacrylic acid and N-phenylacrylamide. The thickness of the polymer layer was ca 1.5 µm. The column was evaluated for the separation of a mixture composed of three peptides (Trp-Gly, angiotensin I, bradykinin). The number of theoretical plates (N) as high as 72,100 plates/column (corresponding to 140,800/m, 7.10 µm plate height) was achieved. The column to column and day to day reproducibility of our columns was found better than 2.1%. For comparison purpose, similar chromatographic data for a selected analyte was also obtained with a commercial microcolumn of 0.5 mm id packed with a conventional C18 phase (5 µm), and 17 µm was the plate height obtained at the optimum flow rate. The van Deemter plots and kinetic plots were also obtained for comparison between our open tubular capillary column and the commercial packed column of a narrow id.
- 4 June 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (16) , 2612-2620
Styrene‐N‐phenylacrylamide co‐polymer modified silica monolith particles with an optimized mixing ratio of monomers as a new stationary phase for the separation of peptides in high performance liquid chromatography
A stationary phase was prepared by chemical derivatization of the support particles with a layer of copolymer composed of styrene and N‐phenyl acrylamide. Silica monolith particles of ca. 2.6 µm (volume‐based average) have been prepared as the support particles by sol‐gel reaction followed by differential sedimentation. The particles were reacted with 3‐chloropropyl trimethoxysilane followed by sodium diethyldithiocarbamate to introduce an initiator moiety. Then, the copolymer layer was immobilized via reversible addition‐fragmentation transfer polymerization. The resultant phase was packed in glass‐lined stainless‐steel micro‐columns (1 x 150 mm) and evaluated for the separation of a mixture composed of five peptides (Trp‐Gly, Thr‐Tyr‐Ser, angiotensin I, isotocin and bradykinin). The effect of monomer mixing ratio (styrene versus N‐phenyl acrylamide) on the chromatographic separation efficiency of the stationary phase was examined. A number of theoretical plates (N) as high as 33 600 plates/column (224 000 plates/m, 4.46 µm plate height) was achieved using the column packed with the optimized stationary phase. The column‐to‐column reproducibility based on three columns packed with three different batches of stationary phase was found satisfactory in separation efficiency, retention factor, and asymmetry factor.
- 4 June 2019
- Published by Wiley in Journal of Separation Science
- Vol. 42 (16) , 2612-2620
Styrene‐N‐phenylacrylamide co‐polymer modified silica monolith particles with an optimized mixing ratio of monomers as a new stationary phase for the separation of peptides in high performance liquid chromatography
A stationary phase was prepared by chemical derivatization of the support particles with a layer of copolymer composed of styrene and N‐phenyl acrylamide. Silica monolith particles of ca. 2.6 µm (volume‐based average) have been prepared as the support particles by sol‐gel reaction followed by differential sedimentation. The particles were reacted with 3‐chloropropyl trimethoxysilane followed by sodium diethyldithiocarbamate to introduce an initiator moiety. Then, the copolymer layer was immobilized via reversible addition‐fragmentation transfer polymerization. The resultant phase was packed in glass‐lined stainless‐steel micro‐columns (1 x 150 mm) and evaluated for the separation of a mixture composed of five peptides (Trp‐Gly, Thr‐Tyr‐Ser, angiotensin I, isotocin and bradykinin). The effect of monomer mixing ratio (styrene versus N‐phenyl acrylamide) on the chromatographic separation efficiency of the stationary phase was examined. A number of theoretical plates (N) as high as 33 600 plates/column (224 000 plates/m, 4.46 µm plate height) was achieved using the column packed with the optimized stationary phase. The column‐to‐column reproducibility based on three columns packed with three different batches of stationary phase was found satisfactory in separation efficiency, retention factor, and asymmetry factor.