Sung Bong Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sung Bong Kim has a total of 209 co-authors. Here are the top co-authors by number of shared publications:
- Seung Wook Kim
Department of Chemical and Biological Engineering, Korea University, Seoul, Korea
25 shared publications Chulhwan Park
12 shared publications- Hah Young Yoo
Department of Biotechnology, Sangmyung University, Seoul, Korea
11 shared publications - Chulhwan Park
Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea
8 shared publications Ja Hyun Lee
Department of Chemical and Biological Engineering, Korea University, Seoul, Republic of Korea
8 shared publicationsSung Ok Han
7 shared publications
Latest Publications
- Open Access
- 28 March 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (13) , eadu2142
Electrophoretic digital colorimetry integrated with electrochemical sweat sensor
Recent advancements in wearable sweat sensors, which use standardized electrochemical and colorimetric mechanisms, offer holistic representation of health status for users. However, the constraints of standardized sweat sensors present ongoing challenges to realization of personalized health management. This study presents an electrocolorimetric (EC) platform that enables the reversible and multiple-time use of colorimetric data visualization using electrophoretic display (EPD). This platform represents the application of low-power EPD in epidermal sweat sensor, evaluated through CIELAB-based methodology which is the first systematic evaluation tool of wearable display performance. Moreover, our platform has been demonstrated in human exercise trials for its ability to detect the lactate threshold (LT). This digital colorimetric system has the potential to play a pivotal role by integrating various health monitoring biomarkers. While providing real-time, continuous, and adjustable range information with high sensitivity, this platform validates its extensive probability as a next-generation wearable epidermal sensor.
- 28 March 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (13) , eadu2142
Open AccessElectrophoretic digital colorimetry integrated with electrochemical sweat sensor
Recent advancements in wearable sweat sensors, which use standardized electrochemical and colorimetric mechanisms, offer holistic representation of health status for users. However, the constraints of standardized sweat sensors present ongoing challenges to realization of personalized health management. This study presents an electrocolorimetric (EC) platform that enables the reversible and multiple-time use of colorimetric data visualization using electrophoretic display (EPD). This platform represents the application of low-power EPD in epidermal sweat sensor, evaluated through CIELAB-based methodology which is the first systematic evaluation tool of wearable display performance. Moreover, our platform has been demonstrated in human exercise trials for its ability to detect the lactate threshold (LT). This digital colorimetric system has the potential to play a pivotal role by integrating various health monitoring biomarkers. While providing real-time, continuous, and adjustable range information with high sensitivity, this platform validates its extensive probability as a next-generation wearable epidermal sensor.
- Open Access
- 13 March 2023
- Published by Wiley in GCB Bioenergy
- Vol. 15 (5) , 731-742
Undefined xylose media extracted from biorefinery waste for enhanced and eco‐friendly production of cephalosporin C by Acremonium chrysogenumM35
Xylose‐rich undefined broth, extracted from the dilute acid pretreatment wastes of barley straw, serves as resourceful media for Acremonium chrysogenum M35 culture and production of cephalosporin C (CPC). Concentrating the extract with proper reprocessing enables to prepare various concentrations of xylose broth (2%–8%). The undefined xylose media were prepared for CPC production from A. chrysogenum M35 by the addition of other nutrients. Cell growth and CPC production were the most effective at 6% xylose and additional 2% glycerol, with maximum CPC production of 9.07 g/L after 6 days, which is higher production than that in defined media prepared with laboratory‐level nutrients and reagents. Investigation of autotrophic and reverse trans‐sulfuration pathways for cysteine synthesis, a limited element of three precursors for CPC synthesis, supports the enhanced CPC production in undefined media. Abundance of xylose ensures a maintained NADPH concentration required for sulfate reduction and synthesis of amino sulfide such as cysteine. Cystathionine‐γ‐lyase activity profiling indicated more efficient biosynthesis in undefined media than in other cultures use glycerol and glucose, and the biosynthesis pathway of CPC production by the cephalosporin gene cluster (i.e. pcbC and cefG genes) was investigated. The process using undefined xylose media was designed, and process simulation program confirmed our results.
- 13 March 2023
- Published by Wiley in GCB Bioenergy
- Vol. 15 (5) , 731-742
Open AccessUndefined xylose media extracted from biorefinery waste for enhanced and eco‐friendly production of cephalosporin C by Acremonium chrysogenumM35
Xylose‐rich undefined broth, extracted from the dilute acid pretreatment wastes of barley straw, serves as resourceful media for Acremonium chrysogenum M35 culture and production of cephalosporin C (CPC). Concentrating the extract with proper reprocessing enables to prepare various concentrations of xylose broth (2%–8%). The undefined xylose media were prepared for CPC production from A. chrysogenum M35 by the addition of other nutrients. Cell growth and CPC production were the most effective at 6% xylose and additional 2% glycerol, with maximum CPC production of 9.07 g/L after 6 days, which is higher production than that in defined media prepared with laboratory‐level nutrients and reagents. Investigation of autotrophic and reverse trans‐sulfuration pathways for cysteine synthesis, a limited element of three precursors for CPC synthesis, supports the enhanced CPC production in undefined media. Abundance of xylose ensures a maintained NADPH concentration required for sulfate reduction and synthesis of amino sulfide such as cysteine. Cystathionine‐γ‐lyase activity profiling indicated more efficient biosynthesis in undefined media than in other cultures use glycerol and glucose, and the biosynthesis pathway of CPC production by the cephalosporin gene cluster (i.e. pcbC and cefG genes) was investigated. The process using undefined xylose media was designed, and process simulation program confirmed our results.
- Top Cited PapersOpen Access
- 26 October 2020
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 117 (45) , 27906-27915
Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities
Significance: Skin-interfaced, wireless devices for clinical-grade monitoring of physiological parameters are of growing interest for uses that range from healthcare to sports performance. This paper introduces a multifunctional skin-mounted microfluidic platform for capture and biomarker analysis of microliter volumes of sweat, a biofluid that can be collected noninvasively, with potential relevance in biophysical sensing. The focus is on colorimetric and digital assessments of a collection of parameters related to stress, including concentrations of vitamin C, cortisol, and glucose, along with quantitative measurements of sweat rate and galvanic skin response. The results represent important additions to a portfolio of emerging capabilities in skin-interfaced technologies for physiological monitoring, with particular relevance to conditions that follow from unhealthy levels of physical and mental stress.
- 26 October 2020
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 117 (45) , 27906-27915
Top Cited PapersOpen AccessSoft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities
Significance: Skin-interfaced, wireless devices for clinical-grade monitoring of physiological parameters are of growing interest for uses that range from healthcare to sports performance. This paper introduces a multifunctional skin-mounted microfluidic platform for capture and biomarker analysis of microliter volumes of sweat, a biofluid that can be collected noninvasively, with potential relevance in biophysical sensing. The focus is on colorimetric and digital assessments of a collection of parameters related to stress, including concentrations of vitamin C, cortisol, and glucose, along with quantitative measurements of sweat rate and galvanic skin response. The results represent important additions to a portfolio of emerging capabilities in skin-interfaced technologies for physiological monitoring, with particular relevance to conditions that follow from unhealthy levels of physical and mental stress.
- 12 October 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (23) , 4391-4403
Skin-interfaced soft microfluidic systems with modular and reusable electronics for in situ capacitive sensing of sweat loss, rate and conductivity
Important insights into human health can be obtained through the non-invasive collection and detailed analysis of sweat, a biofluid that contains a wide range of essential biomarkers. Skin-interfaced microfluidic platforms, characterized by soft materials and thin geometries, offer a collection of capabilities for in situ capture, storage, and analysis of sweat and its constituents. In ambulatory uses cases, the ability to provide real-time feedback on sweat loss, rate and content, without visual inspection of the device, can be important. This paper introduces a low-profile skin-interfaced system that couples disposable microfluidic sampling devices with reusable ‘stick-on’ electrodes and wireless readout electronics that remain isolated from the sweat. An ultra-thin capping layer on the microfluidic platform permits high-sensitivity, contactless capacitive measurements of both sweat loss and sweat conductivity. This architecture avoids the potential for corrosion of the sensing components and eliminates the need for cleaning/sterilizing the electronics, thereby resulting in a cost-effective platform that is simple to use. Optimized electrode designs follow from a combination of extensive benchtop testing, analytical calculations and FEA simulations for two sensing configurations: (1) sweat rate and loss, and (2) sweat conductivity, which contains information about electrolyte content. Both configurations couple to a flexible, wireless electronics platform that digitizes and transmits information to Bluetooth-enabled devices. On-body field testing during physical exercise validates the performance of the system in scenarios of practical relevance to human health and performance.
- 12 October 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (23) , 4391-4403
Skin-interfaced soft microfluidic systems with modular and reusable electronics for in situ capacitive sensing of sweat loss, rate and conductivity
Important insights into human health can be obtained through the non-invasive collection and detailed analysis of sweat, a biofluid that contains a wide range of essential biomarkers. Skin-interfaced microfluidic platforms, characterized by soft materials and thin geometries, offer a collection of capabilities for in situ capture, storage, and analysis of sweat and its constituents. In ambulatory uses cases, the ability to provide real-time feedback on sweat loss, rate and content, without visual inspection of the device, can be important. This paper introduces a low-profile skin-interfaced system that couples disposable microfluidic sampling devices with reusable ‘stick-on’ electrodes and wireless readout electronics that remain isolated from the sweat. An ultra-thin capping layer on the microfluidic platform permits high-sensitivity, contactless capacitive measurements of both sweat loss and sweat conductivity. This architecture avoids the potential for corrosion of the sensing components and eliminates the need for cleaning/sterilizing the electronics, thereby resulting in a cost-effective platform that is simple to use. Optimized electrode designs follow from a combination of extensive benchtop testing, analytical calculations and FEA simulations for two sensing configurations: (1) sweat rate and loss, and (2) sweat conductivity, which contains information about electrolyte content. Both configurations couple to a flexible, wireless electronics platform that digitizes and transmits information to Bluetooth-enabled devices. On-body field testing during physical exercise validates the performance of the system in scenarios of practical relevance to human health and performance.
- Open Access
- 28 August 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (35) , eabb1093
Wirelessly controlled, bioresorbable drug delivery device with active valves that exploit electrochemically triggered crevice corrosion
Bioresorbable drug release platforms offer advanced treatment for hormone imbalances, malignant cancers, and diabetic conditions.
- 28 August 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (35) , eabb1093
Open AccessWirelessly controlled, bioresorbable drug delivery device with active valves that exploit electrochemically triggered crevice corrosion
Bioresorbable drug release platforms offer advanced treatment for hormone imbalances, malignant cancers, and diabetic conditions.
- Top Cited Papers
- 8 April 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 12 (538)
Development of a neural interface for high-definition, long-term recording in rodents and nonhuman primates
A scalable neural interface technology projected to last at least 6 years in the body samples over a thousand brain sites using flexible electronics.
- 8 April 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 12 (538)
Top Cited PapersDevelopment of a neural interface for high-definition, long-term recording in rodents and nonhuman primates
A scalable neural interface technology projected to last at least 6 years in the body samples over a thousand brain sites using flexible electronics.
- 20 November 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (1) , 84-92
Soft, skin-interfaced microfluidic systems with integrated enzymatic assays for measuring the concentration of ammonia and ethanol in sweat
Eccrine sweat is a rich and largely unexplored biofluid that contains a range of important biomarkers, from electrolytes, metabolites, micronutrients and hormones to exogenous agents, each of which can change in concentration with diet, stress level, hydration status and physiologic or metabolic state. Traditionally, clinicians and researchers have used absorbent pads and benchtop analyzers to collect and analyze the biochemical constituents of sweat in controlled, laboratory settings. Recently reported wearable microfluidic and electrochemical sensing devices represent significant advances in this context, with capabilities for rapid, in situ evaluations, in many cases with improved repeatability and accuracy. A limitation is that assays performed in these platforms offer limited control of reaction kinetics and mixing of different reagents and samples. Here, we present a multi-layered microfluidic device platform with designs that eliminate these constraints, to enable integrated enzymatic assays with demonstrations of in situ analysis of the concentrations of ammonia and ethanol in microliter volumes of sweat. Careful characterization of the reaction kinetics and their optimization using statistical techniques yield robust analysis protocols. Human subject studies with sweat initiated by warm-water bathing highlight the operational features of these systems.
- 20 November 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (1) , 84-92
Soft, skin-interfaced microfluidic systems with integrated enzymatic assays for measuring the concentration of ammonia and ethanol in sweat
Eccrine sweat is a rich and largely unexplored biofluid that contains a range of important biomarkers, from electrolytes, metabolites, micronutrients and hormones to exogenous agents, each of which can change in concentration with diet, stress level, hydration status and physiologic or metabolic state. Traditionally, clinicians and researchers have used absorbent pads and benchtop analyzers to collect and analyze the biochemical constituents of sweat in controlled, laboratory settings. Recently reported wearable microfluidic and electrochemical sensing devices represent significant advances in this context, with capabilities for rapid, in situ evaluations, in many cases with improved repeatability and accuracy. A limitation is that assays performed in these platforms offer limited control of reaction kinetics and mixing of different reagents and samples. Here, we present a multi-layered microfluidic device platform with designs that eliminate these constraints, to enable integrated enzymatic assays with demonstrations of in situ analysis of the concentrations of ammonia and ethanol in microliter volumes of sweat. Careful characterization of the reaction kinetics and their optimization using statistical techniques yield robust analysis protocols. Human subject studies with sweat initiated by warm-water bathing highlight the operational features of these systems.
Soft, Skin‐Interfaced Microfluidic Systems with Wireless, Battery‐Free Electronics for Digital, Real‐Time Tracking of Sweat Loss and Electrolyte Composition
Sweat excretion is a dynamic physiological process that varies with body position, activity level, environmental factors, and health status. Conventional means for measuring the properties of sweat yield accurate results but their requirements for sampling and analytics do not allow for use in the field. Emerging wearable devices offer significant advantages over existing approaches, but each has significant drawbacks associated with bulk and weight, inability to quantify volumetric sweat rate and loss, robustness, and/or inadequate accuracy in biochemical analysis. This paper presents a thin, miniaturized, skin‐interfaced microfluidic technology that includes a reusable, battery‐free electronics module for measuring sweat conductivity and rate in real‐time using wireless power from and data communication to electronic devices with capabilities in near field communications (NFC), including most smartphones. The platform exploits ultrathin electrodes integrated within a collection of microchannels as interfaces to circuits that leverage NFC protocols. The resulting capabilities are complementary to those of previously reported colorimetric strategies. Systematic studies of these combined microfluidic/electronic systems, accurate correlations of measurements performed with them to those of laboratory standard instrumentation, and field tests on human subjects exercising and at rest establish the key operational features and their utility in sweat analytics.
Soft, Skin‐Interfaced Microfluidic Systems with Wireless, Battery‐Free Electronics for Digital, Real‐Time Tracking of Sweat Loss and Electrolyte Composition
Sweat excretion is a dynamic physiological process that varies with body position, activity level, environmental factors, and health status. Conventional means for measuring the properties of sweat yield accurate results but their requirements for sampling and analytics do not allow for use in the field. Emerging wearable devices offer significant advantages over existing approaches, but each has significant drawbacks associated with bulk and weight, inability to quantify volumetric sweat rate and loss, robustness, and/or inadequate accuracy in biochemical analysis. This paper presents a thin, miniaturized, skin‐interfaced microfluidic technology that includes a reusable, battery‐free electronics module for measuring sweat conductivity and rate in real‐time using wireless power from and data communication to electronic devices with capabilities in near field communications (NFC), including most smartphones. The platform exploits ultrathin electrodes integrated within a collection of microchannels as interfaces to circuits that leverage NFC protocols. The resulting capabilities are complementary to those of previously reported colorimetric strategies. Systematic studies of these combined microfluidic/electronic systems, accurate correlations of measurements performed with them to those of laboratory standard instrumentation, and field tests on human subjects exercising and at rest establish the key operational features and their utility in sweat analytics.
Super‐Absorbent Polymer Valves and Colorimetric Chemistries for Time‐Sequenced Discrete Sampling and Chloride Analysis of Sweat via Skin‐Mounted Soft Microfluidics
This paper introduces super absorbent polymer valves and colorimetric sensing reagents as enabling components of soft, skin‐mounted microfluidic devices designed to capture, store, and chemically analyze sweat released from eccrine glands. The valving technology enables robust means for guiding the flow of sweat from an inlet location into a collection of isolated reservoirs, in a well‐defined sequence. Analysis in these reservoirs involves a color responsive indicator of chloride concentration with a formulation tailored to offer stable operation with sensitivity optimized for the relevant physiological range. Evaluations on human subjects with comparisons against ex situ analysis illustrate the practical utility of these advances.
Super‐Absorbent Polymer Valves and Colorimetric Chemistries for Time‐Sequenced Discrete Sampling and Chloride Analysis of Sweat via Skin‐Mounted Soft Microfluidics
This paper introduces super absorbent polymer valves and colorimetric sensing reagents as enabling components of soft, skin‐mounted microfluidic devices designed to capture, store, and chemically analyze sweat released from eccrine glands. The valving technology enables robust means for guiding the flow of sweat from an inlet location into a collection of isolated reservoirs, in a well‐defined sequence. Analysis in these reservoirs involves a color responsive indicator of chloride concentration with a formulation tailored to offer stable operation with sensitivity optimized for the relevant physiological range. Evaluations on human subjects with comparisons against ex situ analysis illustrate the practical utility of these advances.
- 1 December 2016
- Published by Elsevier in Process Biochemistry
- Vol. 51 (12) , 1904-1910
Stimulation of 2,3-butanediol production by upregulation of alsR gene transcription level with acetate addition in Enterobacter aerogenes ATCC 29007
- 1 December 2016
- Published by Elsevier in Process Biochemistry
- Vol. 51 (12) , 1904-1910
Stimulation of 2,3-butanediol production by upregulation of alsR gene transcription level with acetate addition in Enterobacter aerogenes ATCC 29007