HNHemal M. Nayak

Hemal M. Nayak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hemal M. Nayak has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Identification of Human Ventricular Tachycardia Demarcated by Fixed Lines of Conduction Block in a 3-Dimensional Hyperboloid Circuit

    by Takuro Nishimura, Nathan Shatz, J. Peter Weiss, Michael Zawaneh, Rong Bai, Andrew D. Beaser, Gaurav A. Upadhyay, Zaid A. Aziz, Hemal M. Nayak, Dalise Y. Shatz, et al.

    BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


  • Open Access

    Atypical pathogens associated with cardiac implantable electronic device infections

    by Utkarsh Kohli, Aniruddha Hazra, Ahmed Shahab, Andrew D. Beaser, Zaid A. Aziz, Gaurav A. Upadhyay, Cevher Ozcan, Roderick Tung, Hemal M. Nayak

    Background: Cardiovascular implantable electronic device (CIED) infections are associated with significant morbidity and mortality making the identification of the causative organism critical. The vast majority of CIED infections are caused by Staphylococcal species. CIED infections associated with atypical pathogens are rare and have not been systematically investigated. The objective of this study is to characterize the clinical course, management and outcome in patients with CIED infection secondary to atypical pathogens.Methods: Medical records of all patients who underwent CIED system extraction at the University of Chicago Medical Center between January 2010 and November 2020 were retrospectively reviewed to identify patients with CIED infection. Demographic, clinical, infection‐related and outcome data were collected. CIED infections were divided into typical and atypical groups based on the pathogens isolated.Results: Among 356 CIED extraction procedures, 130 (37%) were performed for CIED infection. Atypical pathogens were found in 5.4% (n = 7) and included Pantoea species (n = 2), Kocuria species (n = 1), Cutibacterium acnes (n = 1), Corynebacterium tuberculostearicum (n = 1), Corynebacterium striatum (n = 1), Stenotrophomonas maltophilia (n = 1), and Pseudozyma ahidis (n = 1). All patients with atypical CIED infections were successfully treated with total system removal and tailored antibiotic therapy. There were no infection‐related deaths.Conclusions: CIED infections with atypical pathogens were rare and associated with good outcome if diagnosed early and treated with total system removal and tailored antimicrobial therapy. Atypical pathogens cultured from blood, tissue or hardware in patients with CIED infection should be considered pathogens and not contaminants.


  • Open Access

    PR interval prolongation is significantly associated with aortic root abscess: An age‐ and gender‐matched study

    by Utkarsh Kohli, Shirlene Obuobi, Karima Addetia, Takeyoshi Ota, Hemal M. Nayak

    Background: Electrocardiographic abnormalities, such as PR interval prolongation, have been anecdotally reported in patients with aortic root abscess (ARA). An electrocardiographic marker may be useful in identifying those patients with aortic valve endocarditis who may progress to ARA. The objective of this study is to evaluate the change in the PR interval in patients with surgically confirmed ARA and compare it to age‐ and gender‐matched controls with echocardiographically or surgically confirmed aortic valve endocarditis but without aortic root abscess and those hospitalized with diagnoses other than endocarditis.Methods: Patients were eligible for enrollment if they were 18 years or older and were hospitalized for either ARA, aortic valve endocarditis, or for unrelated reasons and had at least one 12‐lead electrocardiogram (ECG) prior to or on the day of hospitalization and at least one ECG after hospitalization but prior to any cardiac surgical procedure. Delta PR interval, defined as the difference between the pre‐ and post‐admission PR interval, was the primary outcome of interest. The patients in the ARA group were age‐ and gender‐matched to patients with aortic valve endocarditis and to those without endocarditis. Comparisons of demographic variables and study outcomes were performed.Results: Eighteen patients with surgically confirmed ARA were enrolled. These patients were age‐ and gender‐matched to 19 patients with aortic valve endocarditis and 18 patients with no past history or evidence of endocarditis during hospitalization. No difference was noted in the baseline PR interval between the groups. However, the PR interval following admission in the aortic root abscess group (201 ± 66 ms) was significantly longer than the PR interval in both the aortic valve endocarditis (162 ± 27 ms) (24%, p = .009) and no endocarditis (143 ± 24 ms) (40%, p < .001) groups. The primary outcome measure, delta PR interval, was significantly longer in the ARA group (35 ± 51 ms) than no endocarditis (−5 ± 17 ms) (p = .001) and aortic valve endocarditis groups (0.2 ± 18) (p = .003).Conclusions: The findings of our study support the notion that the PR interval is more likely to be prolonged in patients with ARA. Since ARA is associated with a high morbidity and mortality, PR interval prolongation in a patient with aortic valve endocarditis should prompt a thorough evaluation for aortic root involvement.


  • Open Access

    Late presentation of recurrent syncope after permanent pacemaker implantation due to Lead−Header malapposition

    by Steven Mazzone, Utkarsh Kohli, Zaid A. Aziz, Andrew D. Beaser, Gaurav A. Upadhyay, Roderick Tung, Hemal M. Nayak


  • Open Access

    Patient Profiles in the Utilization of the CanGaroo® Envelope

    by Hemal Nayak, Andrew D. Beaser, Zaid A Aziz

    The CanGaroo® Envelope (Aziyo Biologics, Silver Spring, MD) is intended to securely hold a cardiovascular implantable electronic device (CIED) to create a stable environment when implanted in the body. Data on the utilization of this newly available product are limited. In this study, our objective was to describe the specific profiles of patients who may benefit from the use of the CanGaroo® Envelope at the time of CIED implantation. The utilization of the CanGaroo® Envelope was assessed from January 2019 to October 2019 among a series of patients who were either undergoing de-novo CIED implantation or replacement. Among a total of 50 patients, the CanGaroo® Envelope was utilized in 15 (30%). Three distinct patient profiles were identified: profile 1: elderly patients with poor tissue turgor at risk of wound dehiscence or erosion; profile 2: patients with a history of previous device infection; and profile 3: patients at high risk of device infection having one or more of the following risk factors - chronic kidney disease, immunocompromised state, or diabetes mellitus. At a mean follow-up of 18 ±3 months, no CIED pocket erosion, dehiscence, or infection was noted. Three distinct profiles of patients who could potentially benefit from the use of the CanGaroo® Envelope were identified by the implanting physicians. Long-term follow-up data, including infection and wound dehiscence rates, are necessary to further analyze the optimal utilization of the device.


  • Transvenous phrenic nerve stimulation for central sleep apnea is safe and effective in patients with concomitant cardiac devices

    by Hemal M. Nayak, Raj Patel, Scott McKane, Kristofer J. James, Timothy E. Meyer, Robin E. Germany, Christoph Stellbrink, Maria Rosa Costanzo, Ralph Augostini


  • Characterization of Lead Adherence Using Intravascular Ultrasound to Assess Difficulty of Transvenous Lead Extraction

    by Andrew D. Beaser, Zaid Aziz, Stephanie A. Besser, Christopher I. Jones, Zenith Jameria, Arun Kannan, Gaurav A. Upadhyay, Michael T. Broman, Cevher Ozcan, Roderick Tung, et al.

    Background: Clinical factors associated with development of intravascular lead adherence (ILA) are unreliable predictors. Because vascular injury in the superior vena cava-right atrium during transvenous lead extraction is more likely to occur in segments with higher degrees of ILA, reliable and accurate assessment of ILA is warranted. We hypothesized that intravascular ultrasound (IVUS) could accurately visualize and quantify ILA and degree of ILA correlates with transvenous lead extraction difficulty. Methods: Serial imaging of leads occurred before transvenous lead extraction using IVUS. ILA areas were classified as high or low grade. Degree of extraction difficulty was assessed using 2 metrics and correlated with ILA grade. Lead extraction difficulty was calculated for each patient and compared with IVUS findings. Results: One hundred fifty-eight vascular segments in 60 patients were analyzed: 141 (89%) low grade versus 17 (11%) high grade. Median extraction time (low=0 versus high grade=97 seconds, P P <0.001) were significantly higher in high-grade segments. Most patients with low lead extraction difficulty score had low ILA grades. Eighty-six percentage of patients with high lead extraction difficulty score had low IVUS grade, and the degree of transvenous lead extraction difficulty was similar to patients with low IVUS grades and lead extraction difficulty scores. Conclusions: IVUS is a feasible imaging modality that may be useful in characterizing ILA in the superior vena cava-right atrium region. An ILA grading system using imaging correlates with extraction difficulty. Most patients with clinical factors associated with higher extraction difficulty may exhibit lower ILA and extraction difficulty based on IVUS imaging. Graphic A graphic abstract is available for this article.