Kosuke Ujihira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kosuke Ujihira has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Akira Yamada
From the Department of Cardiovascular Surgery, Teine Keijinkai Hospital, Sapporo, Japan
3 shared publicationsKatsuhiko Nakanishi
Department of Cardiovascular Surgery, Teine Keijinkai Hospital, Sapporo, Hokkaido, Japan
2 shared publicationsNaritomo Nishioka
Department of Cardiovascular Surgery, Teine Keijinkai Hospital, Sapporo, Hokkaido, Japan
2 shared publicationsRyushi Maruyama
Department of Cardiovascular Surgery, Teine Keijinkai Hospital, Sapporo, Hokkaido, Japan
2 shared publications- Satoru Osaki
Division of Cardiothoracic Surgery, Department of Surgery, University of Wisconsin, Madison, WI USA
2 shared publications Yutaka Iba
Department of Cardiovascular Surgery, Teine Keijinkai Hospital, Sapporo, Hokkaido, Japan
2 shared publications
Latest Publications
- Open Access
- 16 January 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (2) , 101735
Sandwich technique for endovascular repair of type A aortic dissection following stent graft with an inner branch in the ascending aorta
- 16 January 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (2) , 101735
Open AccessSandwich technique for endovascular repair of type A aortic dissection following stent graft with an inner branch in the ascending aorta
- 3 April 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (7) , E723-E734
The impact of increased pulmonary arterial pressure on outcomes after transcatheter aortic valve replacement
Objective: To evaluate the impact of increased pulmonary artery systolic pressure (PASP) on outcomes after transcatheter aortic valve replacement (TAVR).Methods: A total of 242 patients who underwent TAVR were retrospectively reviewed. Transthoracic echocardiography estimated PASP. The cohorts were divided into three groups according to the numerical change of PASP; Increased (post‐TAVR PASP at 1 month minus pre‐TAVR PASP, ≥ + 5 mmHg; n = 52), No change (−5 to +5 mmHg; n = 86) and Decreased (≤ −5 mmHg; n = 104). Patient demographics and clinical outcomes until 1 year were evaluated. Logistic regression model was used for multivariate risk analysis.Results: At 1 year, the Increased group showed higher mortality (21 ± 6%) than the No change group (5 ± 2%) (hazard ratio [HR]: 4.8, 95% confidence interval [CI]: 1.7–13.5; p < .01) and the Decreased group (8 ± 3%) (HR: 2.8, 95% CI: 1.1–6.7; p = .02). Rehospitalization rate for valve‐related or heart failure was also higher in the Increased group (21 ± 6%) than the No change group (10 ± 3%) (HR: 2.4, 95% CI: 1.1–6.0; p = .04).Predictors of PASP deterioration were hypertension (odds ratio [OR]: 3.9, 95% CI: 1.1–13.8; p = .04) and left ventricular end‐diastolic diameter >50 mm (OR: 2.2, 95% CI: 1.1–4.6; p = .04), and the increased PASP remained an independent predictor of 1‐year all‐cause mortality (HR; 2.7, 95% CI: 1.0–6.8; p = .04).Conclusions: Regardless of the baseline PASP, patients with increased PASP at 1 month after successful TAVR were at higher risk of mortality and rehospitalization within 1 year. Strict medical management should be considered for patients who showed dilated left ventricle preoperatively.
- 3 April 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (7) , E723-E734
The impact of increased pulmonary arterial pressure on outcomes after transcatheter aortic valve replacement
Objective: To evaluate the impact of increased pulmonary artery systolic pressure (PASP) on outcomes after transcatheter aortic valve replacement (TAVR).Methods: A total of 242 patients who underwent TAVR were retrospectively reviewed. Transthoracic echocardiography estimated PASP. The cohorts were divided into three groups according to the numerical change of PASP; Increased (post‐TAVR PASP at 1 month minus pre‐TAVR PASP, ≥ + 5 mmHg; n = 52), No change (−5 to +5 mmHg; n = 86) and Decreased (≤ −5 mmHg; n = 104). Patient demographics and clinical outcomes until 1 year were evaluated. Logistic regression model was used for multivariate risk analysis.Results: At 1 year, the Increased group showed higher mortality (21 ± 6%) than the No change group (5 ± 2%) (hazard ratio [HR]: 4.8, 95% confidence interval [CI]: 1.7–13.5; p < .01) and the Decreased group (8 ± 3%) (HR: 2.8, 95% CI: 1.1–6.7; p = .02). Rehospitalization rate for valve‐related or heart failure was also higher in the Increased group (21 ± 6%) than the No change group (10 ± 3%) (HR: 2.4, 95% CI: 1.1–6.0; p = .04).Predictors of PASP deterioration were hypertension (odds ratio [OR]: 3.9, 95% CI: 1.1–13.8; p = .04) and left ventricular end‐diastolic diameter >50 mm (OR: 2.2, 95% CI: 1.1–4.6; p = .04), and the increased PASP remained an independent predictor of 1‐year all‐cause mortality (HR; 2.7, 95% CI: 1.0–6.8; p = .04).Conclusions: Regardless of the baseline PASP, patients with increased PASP at 1 month after successful TAVR were at higher risk of mortality and rehospitalization within 1 year. Strict medical management should be considered for patients who showed dilated left ventricle preoperatively.
- 25 April 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (6) , 503-505
Transcatheter aortic valve replacement in patients with anomalous left circumflex coronary artery
The anomalous left circumflex artery can be a risk for coronary stenosis or obstruction during transcatheter aortic valve replacement; however, the best procedural management has not been clarified. We describe three patients with severe aortic valve stenosis as well as anomalous left circumflex artery. In the first patient, a coronary guidewire with balloon was placed before deploying a SAPIEN 3 transcatheter heart valve, as protection from the coronary occlusion or stenosis. For the second and third patients, no coronary protection was used. All procedures were completed safely and no complications were detected at one‐year follow‐up.
- 25 April 2019
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 34 (6) , 503-505
Transcatheter aortic valve replacement in patients with anomalous left circumflex coronary artery
The anomalous left circumflex artery can be a risk for coronary stenosis or obstruction during transcatheter aortic valve replacement; however, the best procedural management has not been clarified. We describe three patients with severe aortic valve stenosis as well as anomalous left circumflex artery. In the first patient, a coronary guidewire with balloon was placed before deploying a SAPIEN 3 transcatheter heart valve, as protection from the coronary occlusion or stenosis. For the second and third patients, no coronary protection was used. All procedures were completed safely and no complications were detected at one‐year follow‐up.
- Open Access
- 1 September 2017
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 12 (5) , 363-369
Novel Dry-Lab Training Method for Totally Endoscopic Coronary Anastomosis
We describe our original dry-lab training system for nonrobotic and beating heart endoscopic coronary artery anastomosis. All the materials used for this training were commercially available. We selected a boxed machine, which can produce pulsatile movements of artificial vessels, and on its roof, we installed a two-dimensional home video camera and a monitor. A multiple-holed plate was placed in front of the machine, and through these holes, a trainee inserted endoscopic surgical instruments and anastomosed the artificial vessels by running fashion while watching the monitor. This training program has four stages. During the first stage, a trainee has to demonstrate mastery in conducting a conventional off-pump coronary artery anastomosis without assistance. The second stage is the “nonbeating” version, and the third stage is the “beating” version with the model mentioned previously. After a trainee gets accustomed to the third stage, the original artificial vessel is replaced with an extremely fragile one, and this is the fourth stage. Our trainee conducted one hundred fourth-stage anastomoses and each procedure was recorded with the video camera. We analyzed several factors from the videos and evaluated the efficacy of the training method. We compared the outcomes of the first 50 consecutive anastomoses with the following 50 ones and described the learning curves. The comparison showed a significant decrease in anastomotic time and vessel injury. We considered the quality of anastomosis acceptable after 47 anastomoses, and anastomotic time fell below 15 minutes at the 81st training at the fourth stage. Our dry-lab system might be an effective training method for endoscopic coronary anastomosis.
- 1 September 2017
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 12 (5) , 363-369
Open AccessNovel Dry-Lab Training Method for Totally Endoscopic Coronary Anastomosis
We describe our original dry-lab training system for nonrobotic and beating heart endoscopic coronary artery anastomosis. All the materials used for this training were commercially available. We selected a boxed machine, which can produce pulsatile movements of artificial vessels, and on its roof, we installed a two-dimensional home video camera and a monitor. A multiple-holed plate was placed in front of the machine, and through these holes, a trainee inserted endoscopic surgical instruments and anastomosed the artificial vessels by running fashion while watching the monitor. This training program has four stages. During the first stage, a trainee has to demonstrate mastery in conducting a conventional off-pump coronary artery anastomosis without assistance. The second stage is the “nonbeating” version, and the third stage is the “beating” version with the model mentioned previously. After a trainee gets accustomed to the third stage, the original artificial vessel is replaced with an extremely fragile one, and this is the fourth stage. Our trainee conducted one hundred fourth-stage anastomoses and each procedure was recorded with the video camera. We analyzed several factors from the videos and evaluated the efficacy of the training method. We compared the outcomes of the first 50 consecutive anastomoses with the following 50 ones and described the learning curves. The comparison showed a significant decrease in anastomotic time and vessel injury. We considered the quality of anastomosis acceptable after 47 anastomoses, and anastomotic time fell below 15 minutes at the 81st training at the fourth stage. Our dry-lab system might be an effective training method for endoscopic coronary anastomosis.
- Open Access
- 1 November 2016
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 11 (6) , 453-456
Alternative Treatment for Residual Aortobronchial Fistula after Thoracic Endovascular Aortic Repair
A patient with an aortobronchial fistula secondary to a thoracic endovascular aortic repair was successfully treated with a re-thoracic endovascular aortic repair with debranching technique. Five months postoperatively, the aneurysm had shrunk; however, computed tomography revealed air in the thrombo-excluded aortic aneurysmal sac without signs of infection. Because of worsening air finding at the eighth month, we performed a resection of the residual fistula and wrapped the stent graft in a pedicled muscle flap.
- 1 November 2016
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 11 (6) , 453-456
Open AccessAlternative Treatment for Residual Aortobronchial Fistula after Thoracic Endovascular Aortic Repair
A patient with an aortobronchial fistula secondary to a thoracic endovascular aortic repair was successfully treated with a re-thoracic endovascular aortic repair with debranching technique. Five months postoperatively, the aneurysm had shrunk; however, computed tomography revealed air in the thrombo-excluded aortic aneurysmal sac without signs of infection. Because of worsening air finding at the eighth month, we performed a resection of the residual fistula and wrapped the stent graft in a pedicled muscle flap.
- Open Access
- 7 July 2016
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 11 (1) , 95
A case report of primary cardiac myxofibrosarcoma presenting with severe congestive heart failure
Primary cardiac sarcomas are extremely rare. Furthermore, the myxofibrosarcomas are one of the rarest forms of cardiac sarcomas, and its prognosis is known to be quite poor. This is a case of a 23-year-old man who presented with acute severe congestive heart failure caused by almost complete obstruction of the mitral valve due to a large left atrial tumor. The patient required endotracheal intubation before his arrival to the hospital, and underwent an emergent surgical excision of the tumor. The tumor had a complex shape and originated from the orifice of the right upper pulmonary vein. Because the tumor seemed to extend over most of the surface of the left atrium, it seemed impossible to reconstruct the left atrium had we done a complete transmural resection. Instead, we carefully peeled the tumor leaving the outer layer of the left atrial wall. We applied cryoablation to the attached site, in order to prevent a recurrence of the tumor. The pathology report revealed that the tumor was a myxofibrosarcoma, and it seemed to originate from the heart. The patient received radiation therapy after the surgery and continues to be alive and well after 1-year, without apparent recurrence. Cardiac myxofibrosarcoma can cause acute, severe left-sided heart failure. Non-transmural atrial wall resection with cryoablation might be effective for patients with cardiac myxofibrosarcomas with extensive atrial attachment.
- 7 July 2016
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 11 (1) , 95
Open AccessA case report of primary cardiac myxofibrosarcoma presenting with severe congestive heart failure
Primary cardiac sarcomas are extremely rare. Furthermore, the myxofibrosarcomas are one of the rarest forms of cardiac sarcomas, and its prognosis is known to be quite poor. This is a case of a 23-year-old man who presented with acute severe congestive heart failure caused by almost complete obstruction of the mitral valve due to a large left atrial tumor. The patient required endotracheal intubation before his arrival to the hospital, and underwent an emergent surgical excision of the tumor. The tumor had a complex shape and originated from the orifice of the right upper pulmonary vein. Because the tumor seemed to extend over most of the surface of the left atrium, it seemed impossible to reconstruct the left atrium had we done a complete transmural resection. Instead, we carefully peeled the tumor leaving the outer layer of the left atrial wall. We applied cryoablation to the attached site, in order to prevent a recurrence of the tumor. The pathology report revealed that the tumor was a myxofibrosarcoma, and it seemed to originate from the heart. The patient received radiation therapy after the surgery and continues to be alive and well after 1-year, without apparent recurrence. Cardiac myxofibrosarcoma can cause acute, severe left-sided heart failure. Non-transmural atrial wall resection with cryoablation might be effective for patients with cardiac myxofibrosarcomas with extensive atrial attachment.
- Open Access
- 11 February 2016
- Published by Springer Nature in Surgical Case Reports
- Vol. 2 (1) , 11
Bladder and rectal incontinence without paraplegia or paraparesis after endovascular aneurysm repair
- 11 February 2016
- Published by Springer Nature in Surgical Case Reports
- Vol. 2 (1) , 11
Open AccessBladder and rectal incontinence without paraplegia or paraparesis after endovascular aneurysm repair