Yuta Masuyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yuta Masuyama has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Takeshi Ohshima
National Institutes for Quantum Science and Technology
10 shared publications - Tokuyuki Teraji
National Institute for Materials Science
6 shared publications - Chikara Shinei
Research Center for Electronic and Optical Materials, National Institute for Materials Science 2 , Tsukuba, Ibaraki 305-0044
5 shared publications - Mutsuko Hatano
Department of Electrical and Electronic Engineering, Institute of Science Tokyo 1 , Meguro, Tokyo 152-8550
5 shared publications - Hiroshi Abe
National Institutes for Quantum Science and Technology
4 shared publications - Takashi Taniguchi
National Institute for Materials Science 1-1 Namiki
4 shared publications
Latest Publications
- 6 October 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (19) , 191002
Vacancy-mediated nitrogen diffusion and aggregation via high-fluence electron beam irradiation in HPHT synthesized diamond crystal
The negatively charged nitrogen vacancy (NV − ) center in diamond is a promising point defect for highly sensitive quantum sensing. The formation of high-density NV − centers is essential for improving sensitivity. We performed room-temperature electron beam irradiation (EBI) and annealing on nitrogen-doped high-pressure high-temperature diamond crystals, aiming to convert all substitutional nitrogen into NV structures by increasing the EBI fluence. While the N s 0 to NV 0/− conversion process dominated at low EBI fluences, in a high-fluence region, NV 0/− center and N s 0/+ concentrations decreased with increasing EBI fluence, indicating the formation of unknown nitrogen-related defects such as the H3 center, which is a nitrogen and vacancy aggregation defect. Although the H3 centers were observed at high EBI fluence, their annealing temperature of 1375 ± 25 °C was lower than the typically reported temperatures over 1600 °C. We attribute this low-temperature formation to vacancy-mediated nitrogen diffusion and aggregation.
- 6 October 2026
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 65 (19) , 191002
Vacancy-mediated nitrogen diffusion and aggregation via high-fluence electron beam irradiation in HPHT synthesized diamond crystal
The negatively charged nitrogen vacancy (NV − ) center in diamond is a promising point defect for highly sensitive quantum sensing. The formation of high-density NV − centers is essential for improving sensitivity. We performed room-temperature electron beam irradiation (EBI) and annealing on nitrogen-doped high-pressure high-temperature diamond crystals, aiming to convert all substitutional nitrogen into NV structures by increasing the EBI fluence. While the N s 0 to NV 0/− conversion process dominated at low EBI fluences, in a high-fluence region, NV 0/− center and N s 0/+ concentrations decreased with increasing EBI fluence, indicating the formation of unknown nitrogen-related defects such as the H3 center, which is a nitrogen and vacancy aggregation defect. Although the H3 centers were observed at high EBI fluence, their annealing temperature of 1375 ± 25 °C was lower than the typically reported temperatures over 1600 °C. We attribute this low-temperature formation to vacancy-mediated nitrogen diffusion and aggregation.
- Open Access
- 28 September 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (13)
Achieving strain-limited ensemble dephasing times in solid-state quantum sensor with a compact single magnet assembly
Solid-state quantum sensors offer the promising prospect of high-sensitivity sensing across various environments, including at room temperature and atmospheric pressure. Highly sensitive solid-state quantum sensors require long ensemble dephasing times (T2*) in mm-scale sample areas. This requirement demands a highly uniform bias magnetic field across all qubits, which has traditionally required large magnetic field sources such as Helmholtz coils or a pair of magnets. Meanwhile, to expand the range of applications of quantum sensors, portable sensors are required, but it is difficult to carry these large magnets. Balancing the miniaturization of the quantum sensor with high sensitivity is a significant challenge. In this study, we achieve a long ensemble dephasing time for nitrogen-vacancy (NV) centers in a large sample volume using a single, compact, and optimized magnet assembly. By using a magnet design derived from an inverse problem-based analysis, we reduced the magnet assembly volume to 0.23% of the Helmholtz coil volume. We achieve an ensemble dephasing time of 5.32 μs for the entire NV center ensemble across the sample thickness, comparable to that obtained with a standard Helmholtz coil setup. This dephasing is limited by strain-induced dephasing across the diamond sample thickness, with a dephasing rate of 188 kHz, which represents the state-of-the-art diamond quality for bulk quantum sensors. Our work paves the way for the miniaturization of high-sensitivity quantum sensors, enabling new sensor designs and the construction of compact, highly sensitive quantum sensor arrays.
- 28 September 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (13)
Open AccessAchieving strain-limited ensemble dephasing times in solid-state quantum sensor with a compact single magnet assembly
Solid-state quantum sensors offer the promising prospect of high-sensitivity sensing across various environments, including at room temperature and atmospheric pressure. Highly sensitive solid-state quantum sensors require long ensemble dephasing times (T2*) in mm-scale sample areas. This requirement demands a highly uniform bias magnetic field across all qubits, which has traditionally required large magnetic field sources such as Helmholtz coils or a pair of magnets. Meanwhile, to expand the range of applications of quantum sensors, portable sensors are required, but it is difficult to carry these large magnets. Balancing the miniaturization of the quantum sensor with high sensitivity is a significant challenge. In this study, we achieve a long ensemble dephasing time for nitrogen-vacancy (NV) centers in a large sample volume using a single, compact, and optimized magnet assembly. By using a magnet design derived from an inverse problem-based analysis, we reduced the magnet assembly volume to 0.23% of the Helmholtz coil volume. We achieve an ensemble dephasing time of 5.32 μs for the entire NV center ensemble across the sample thickness, comparable to that obtained with a standard Helmholtz coil setup. This dephasing is limited by strain-induced dephasing across the diamond sample thickness, with a dephasing rate of 188 kHz, which represents the state-of-the-art diamond quality for bulk quantum sensors. Our work paves the way for the miniaturization of high-sensitivity quantum sensors, enabling new sensor designs and the construction of compact, highly sensitive quantum sensor arrays.
- 2 June 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (21)
Axial and shear stress in nitrogen-doped homo-epitaxial chemical-vapor-deposition diamond films
Control of residual stress in diamond is crucial to improve the spin dephasing time (T2*) of nitrogen-vacancy centers for quantum applications. When the surface of a substrate used for homoepitaxial growth is crystallographically tilted at a slight angle away from a major crystal plane [e.g., (001)], the atomic structure of the surface at the homoepitaxial growth front changes, which in turn alters the homoepitaxial growth mode. As a result, the incorporated stress in the homoepitaxial diamond layer is also likely to vary. In this study, we investigated the effect of the substrate inclination-direction in the (001) plane, the so-called inclination-direction, on the residual stresses. The 400 μm-thick nitrogen-doped (001) diamond films were grown on the substrates with different inclination-directions, a [110] or a [100]. Mapping of the stress tensor revealed that the inclination-direction alters the nature of the residual stress: the [110] inclination-direction led to a dominant gradient in the axial stress (σxx + σyy + σzz) along the [001] direction, whereas the [100] inclination-direction led in shear stress (σxy, σyz, and σzx). Although the nature of the residual stress changed with the inclination-direction, the mean values of the measured T2* were comparable for both samples (1.25 μs for [110] and 1.26 μs for [100]). This result was consistent with the fact that the dephasing rate due to the stress in the CVD diamond film (0.25 MHz for [110] and 0.26 MHz for [100]) was comparable.
- 2 June 2026
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 139 (21)
Axial and shear stress in nitrogen-doped homo-epitaxial chemical-vapor-deposition diamond films
Control of residual stress in diamond is crucial to improve the spin dephasing time (T2*) of nitrogen-vacancy centers for quantum applications. When the surface of a substrate used for homoepitaxial growth is crystallographically tilted at a slight angle away from a major crystal plane [e.g., (001)], the atomic structure of the surface at the homoepitaxial growth front changes, which in turn alters the homoepitaxial growth mode. As a result, the incorporated stress in the homoepitaxial diamond layer is also likely to vary. In this study, we investigated the effect of the substrate inclination-direction in the (001) plane, the so-called inclination-direction, on the residual stresses. The 400 μm-thick nitrogen-doped (001) diamond films were grown on the substrates with different inclination-directions, a [110] or a [100]. Mapping of the stress tensor revealed that the inclination-direction alters the nature of the residual stress: the [110] inclination-direction led to a dominant gradient in the axial stress (σxx + σyy + σzz) along the [001] direction, whereas the [100] inclination-direction led in shear stress (σxy, σyz, and σzx). Although the nature of the residual stress changed with the inclination-direction, the mean values of the measured T2* were comparable for both samples (1.25 μs for [110] and 1.26 μs for [100]). This result was consistent with the fact that the dephasing rate due to the stress in the CVD diamond film (0.25 MHz for [110] and 0.26 MHz for [100]) was comparable.
- Open Access
- 8 April 2025
- Published by Springer Nature in Communications Materials
- Vol. 6 (1) , 1-9
Homogeneous spin-dephasing time of NV− centre in millimetre-scale 12C-enriched high-pressure high-temperature diamond crystals
- 8 April 2025
- Published by Springer Nature in Communications Materials
- Vol. 6 (1) , 1-9
Open AccessHomogeneous spin-dephasing time of NV− centre in millimetre-scale 12C-enriched high-pressure high-temperature diamond crystals
- Open Access
- 5 August 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Columnar excitation fluorescence microscope for accurate evaluation of quantum properties of color centers in bulk materials
Color centers in wide band-gap semiconductors, which have superior quantum properties even at room temperature and atmospheric pressure, have been actively applied to quantum sensing devices. Characterizing the quantum properties of the color centers in the semiconductor materials and ensuring that these properties are uniform over a wide area are key issues for developing quantum sensing devices based on color centers. In this article, we have developed an optics design protocol optimized for evaluating the quantum properties of color centers and have used this design approach to develop a new microscopy system called columnar excitation fluorescence microscope (CEFM). The essence of this system is to maximize the amount of fluorescence detection of polarized color centers, which is achieved by large-volume and uniform laser excitation along the sample thickness with sufficient laser power density. This laser excitation technique prevents undesirable transitions to undesirable charge states and undesirable light, such as unpolarized color center fluorescence, while significantly increasing the color center fluorescence. This feature enables fast measurements with a high signal-to-noise ratio, making it possible to evaluate the spatial distribution of quantum properties across an entire mm-size sample without using a darkroom, which is difficult with typical confocal microscope systems.
- 5 August 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Open AccessColumnar excitation fluorescence microscope for accurate evaluation of quantum properties of color centers in bulk materials
Color centers in wide band-gap semiconductors, which have superior quantum properties even at room temperature and atmospheric pressure, have been actively applied to quantum sensing devices. Characterizing the quantum properties of the color centers in the semiconductor materials and ensuring that these properties are uniform over a wide area are key issues for developing quantum sensing devices based on color centers. In this article, we have developed an optics design protocol optimized for evaluating the quantum properties of color centers and have used this design approach to develop a new microscopy system called columnar excitation fluorescence microscope (CEFM). The essence of this system is to maximize the amount of fluorescence detection of polarized color centers, which is achieved by large-volume and uniform laser excitation along the sample thickness with sufficient laser power density. This laser excitation technique prevents undesirable transitions to undesirable charge states and undesirable light, such as unpolarized color center fluorescence, while significantly increasing the color center fluorescence. This feature enables fast measurements with a high signal-to-noise ratio, making it possible to evaluate the spatial distribution of quantum properties across an entire mm-size sample without using a darkroom, which is difficult with typical confocal microscope systems.
- 4 December 2023
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 382 (2265) , 20220322
Nitrogen concentration control during diamond growth for NV − centre formation
Negatively charged nitrogen-vacancy (NV − ) centres formed in diamond crystals are point defects that have potential applications in various quantum devices such as highly sensitive magnetic sensors. To improve the sensitivity of magnetic sensors using NV − centres, it is essential to precisely control the nitrogen concentration in the crystals. In this paper, we demonstrated that nitrogen concentration in diamond can be controlled with high precision for the following two representative growth methods. One is the high-pressure/high-temperature (HPHT) synthesis method and the other is the chemical vapour deposition (CVD) method. The nitrogen concentration of HPHT-grown diamond decreased semi-logarithmically with increasing contents of titanium or aluminium as nitrogen getter materials. The nitrogen concentration of CVD-grown diamond increased linearly with increasing the flow rate ratio of nitrogen to carbon. NV − centres were formed by controlling the total fluence of electron beams so that approximately 20% of the nitrogen became NV − centres. The coherence time of electron spin of NV − centres obtained by the Hahn-echo pulse sequence T 2 of these diamond crystals was inversely proportional to the nitrogen concentration. A comparison of T 2 of the NV − centres for HPHT-synthesized and CVD-grown diamonds showed no significant difference between them. This article is part of the Theo Murphy meeting issue ‘Diamond for quantum applications’.
- 4 December 2023
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 382 (2265) , 20220322
Nitrogen concentration control during diamond growth for NV − centre formation
Negatively charged nitrogen-vacancy (NV − ) centres formed in diamond crystals are point defects that have potential applications in various quantum devices such as highly sensitive magnetic sensors. To improve the sensitivity of magnetic sensors using NV − centres, it is essential to precisely control the nitrogen concentration in the crystals. In this paper, we demonstrated that nitrogen concentration in diamond can be controlled with high precision for the following two representative growth methods. One is the high-pressure/high-temperature (HPHT) synthesis method and the other is the chemical vapour deposition (CVD) method. The nitrogen concentration of HPHT-grown diamond decreased semi-logarithmically with increasing contents of titanium or aluminium as nitrogen getter materials. The nitrogen concentration of CVD-grown diamond increased linearly with increasing the flow rate ratio of nitrogen to carbon. NV − centres were formed by controlling the total fluence of electron beams so that approximately 20% of the nitrogen became NV − centres. The coherence time of electron spin of NV − centres obtained by the Hahn-echo pulse sequence T 2 of these diamond crystals was inversely proportional to the nitrogen concentration. A comparison of T 2 of the NV − centres for HPHT-synthesized and CVD-grown diamonds showed no significant difference between them. This article is part of the Theo Murphy meeting issue ‘Diamond for quantum applications’.
- 5 September 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 20 (3) , L031001
Highly Sensitive Temperature Sensing Using the Silicon Vacancy in Silicon Carbide by Simultaneously Resonated Optically Detected Magnetic Resonance
Quantum sensors using silicon vacancy () in silicon carbide () are expected to be capable of directly measuring inside devices. It is a serious problem that we have to employ the excited state (ES) of with very low temperature sensitivity for quantum sensing due to there being no temperature sensitivity for the ground state (GS). Here, we propose a temperature measurement protocol, simultaneously resonated optically detected magnetic resonance (SRODMR), based on the modulation of the GS ODMR response resulting from simultaneous resonance of both GS and ES. This protocol diverts part of the GS ODMR contrast to temperature measurement, and in principle, temperature can be measured at an equivalent signal intensity to that of GS ODMR. SRODMR improves signal intensity by 1 order of magnitude compared with the conventional method (ES ODMR), leading to temperature measurements with a smaller error.- 5 September 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 20 (3) , L031001
Highly Sensitive Temperature Sensing Using the Silicon Vacancy in Silicon Carbide by Simultaneously Resonated Optically Detected Magnetic Resonance
Quantum sensors using silicon vacancy () in silicon carbide () are expected to be capable of directly measuring inside devices. It is a serious problem that we have to employ the excited state (ES) of with very low temperature sensitivity for quantum sensing due to there being no temperature sensitivity for the ground state (GS). Here, we propose a temperature measurement protocol, simultaneously resonated optically detected magnetic resonance (SRODMR), based on the modulation of the GS ODMR response resulting from simultaneous resonance of both GS and ES. This protocol diverts part of the GS ODMR contrast to temperature measurement, and in principle, temperature can be measured at an equivalent signal intensity to that of GS ODMR. SRODMR improves signal intensity by 1 order of magnitude compared with the conventional method (ES ODMR), leading to temperature measurements with a smaller error.- Open Access
Long Rayleigh length confocal microscope: A fast evaluation tool for obtaining quantum properties of color centers
Color centers in wide band-gap semiconductors, which have superior quantum properties even at room temperature and atmospheric pressure, have been actively applied to quantum sensing devices. Characterization of the quantum properties of the color centers in the semiconductor materials and ensuring that these properties are uniform over a wide area are key issues for developing quantum sensing devices based on color center. In this article, we will describe the principle and performance of a newly developed confocal microscope system with a long Rayleigh length (LRCFM). This system can characterize a wider area faster than the confocal microscope systems commonly used for color center evaluation.
Open AccessLong Rayleigh length confocal microscope: A fast evaluation tool for obtaining quantum properties of color centers
Color centers in wide band-gap semiconductors, which have superior quantum properties even at room temperature and atmospheric pressure, have been actively applied to quantum sensing devices. Characterization of the quantum properties of the color centers in the semiconductor materials and ensuring that these properties are uniform over a wide area are key issues for developing quantum sensing devices based on color center. In this article, we will describe the principle and performance of a newly developed confocal microscope system with a long Rayleigh length (LRCFM). This system can characterize a wider area faster than the confocal microscope systems commonly used for color center evaluation.
- Open Access
- 7 December 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (21) , 214402
Nitrogen related paramagnetic defects: Decoherence source of ensemble of NV− center
We investigated spin-echo coherence times T2 of negatively charged nitrogen vacancy center (NV−) ensembles in single-crystalline diamond synthesized by either the high-pressure and high-temperature and chemical vapor deposition methods. This study specifically examined the magnetic dipole–dipole interaction (DDI) from the various electronic spin baths, which are the source of T2 decoherence. Diamond samples with NV− center concentration [NV−] comparable to those of neutral substitutional nitrogen concentration [Ns0] were used for DDI estimation. Results show that the T2 of the ensemble NV− center decreased in inverse proportion to the concentration of nitrogen-related paramagnetic defects [NPM], being the sum of [Ns0], [NV−], and [NV0], which is a neutrally charged state NV center. This inversely proportional relation between T2 and [NPM] indicates that the nitrogen-related paramagnetic defects of three kinds are the main decoherence source of the ensemble NV− center in the single-crystalline diamond. We found that the DDI coefficient of NVH− center was significantly smaller than that of Ns0, the NV0 center, or the NV− center. We ascertained the DDI coefficient of the NV− center through experimentation using a linear summation of the decoherence rates of each nitrogen-related paramagnetic defect. The obtained value of 89 μs ppm for corresponds well to the value estimated from the relation between DDI coefficient and spin multiplicity.- 7 December 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (21) , 214402
Open AccessNitrogen related paramagnetic defects: Decoherence source of ensemble of NV− center
We investigated spin-echo coherence times T2 of negatively charged nitrogen vacancy center (NV−) ensembles in single-crystalline diamond synthesized by either the high-pressure and high-temperature and chemical vapor deposition methods. This study specifically examined the magnetic dipole–dipole interaction (DDI) from the various electronic spin baths, which are the source of T2 decoherence. Diamond samples with NV− center concentration [NV−] comparable to those of neutral substitutional nitrogen concentration [Ns0] were used for DDI estimation. Results show that the T2 of the ensemble NV− center decreased in inverse proportion to the concentration of nitrogen-related paramagnetic defects [NPM], being the sum of [Ns0], [NV−], and [NV0], which is a neutrally charged state NV center. This inversely proportional relation between T2 and [NPM] indicates that the nitrogen-related paramagnetic defects of three kinds are the main decoherence source of the ensemble NV− center in the single-crystalline diamond. We found that the DDI coefficient of NVH− center was significantly smaller than that of Ns0, the NV0 center, or the NV− center. We ascertained the DDI coefficient of the NV− center through experimentation using a linear summation of the decoherence rates of each nitrogen-related paramagnetic defect. The obtained value of 89 μs ppm for corresponds well to the value estimated from the relation between DDI coefficient and spin multiplicity. - Open Access
- 30 December 2021
- Published by MDPI AG in Quantum Beam Science
- Vol. 6 (1) , 2
Ensemble Negatively-Charged Nitrogen-Vacancy Centers in Type-Ib Diamond Created by High Fluence Electron Beam Irradiation
Electron beam irradiation into type-Ib diamond is known as a good method for the creation of high concentration negatively-charged nitrogen-vacancy (NV−) centers by which highly sensitive quantum sensors can be fabricated. In order to understand the creation mechanism of NV− centers, we study the behavior of substitutional isolated nitrogen (P1 centers) and NV− centers in type-Ib diamond, with an initial P1 concentration of 40–80 ppm by electron beam irradiation up to 8.0 × 1018 electrons/cm2. P1 concentration and NV− concentration were measured using electron spin resonance and photoluminescence measurements. P1 center count decreases with increasing irradiation fluence up to 8.0 × 1018 electrons/cm2. The rate of decrease in P1 is slightly lower at irradiation fluence above 4.0 × 1018 electrons/cm2 especially for samples of low initial P1 concentration. Comparing concentration of P1 centers with that of NV− centers, it suggests that a part of P1 centers plays a role in the formation of other defects. The usefulness of electron beam irradiation to type-Ib diamonds was confirmed by the resultant conversion efficiency from P1 to NV− center around 12–19%.
- 30 December 2021
- Published by MDPI AG in Quantum Beam Science
- Vol. 6 (1) , 2
Open AccessEnsemble Negatively-Charged Nitrogen-Vacancy Centers in Type-Ib Diamond Created by High Fluence Electron Beam Irradiation
Electron beam irradiation into type-Ib diamond is known as a good method for the creation of high concentration negatively-charged nitrogen-vacancy (NV−) centers by which highly sensitive quantum sensors can be fabricated. In order to understand the creation mechanism of NV− centers, we study the behavior of substitutional isolated nitrogen (P1 centers) and NV− centers in type-Ib diamond, with an initial P1 concentration of 40–80 ppm by electron beam irradiation up to 8.0 × 1018 electrons/cm2. P1 concentration and NV− concentration were measured using electron spin resonance and photoluminescence measurements. P1 center count decreases with increasing irradiation fluence up to 8.0 × 1018 electrons/cm2. The rate of decrease in P1 is slightly lower at irradiation fluence above 4.0 × 1018 electrons/cm2 especially for samples of low initial P1 concentration. Comparing concentration of P1 centers with that of NV− centers, it suggests that a part of P1 centers plays a role in the formation of other defects. The usefulness of electron beam irradiation to type-Ib diamonds was confirmed by the resultant conversion efficiency from P1 to NV− center around 12–19%.