Felipe Bianchini D'AVila
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Felipe Bianchini D'AVila has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Sérgio Luiz Dalmora
Department of Industrial Pharmacy, Federal University of Santa Maria, 97105-900 Santa Maria-RS, Brazil
6 shared publications Pedro Eduardo Fröehlich
Postgraduate Program in Pharmaceutical Sciences, Federal University of Rio Grande do Sul, Av. Ipiranga 2752, 90610-000 Porto Alegre, RS, Brazil
3 shared publicationsRenata Pereira Limberger
Postgraduate Program in Pharmaceutical Sciences, Federal University of Rio Grande do Sul, Av. Ipiranga 2752, 90610-000 Porto Alegre, RS, Brazil
3 shared publications- Ana Maria Bergold
Universidade Federal do Rio Grande do Sul
2 shared publications Andrea Garcia Pereira
Postgraduate Program in Pharmaceutical Sciences, Federal University of Rio Grande do Sul, Av. Ipiranga 2752, 90610-000 Porto Alegre, RS, Brazil
2 shared publications- Clarice Madalena Bueno Rolim
Universidade Federal de Santa Maria
2 shared publications
Latest Publications
- 1 September 2016
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 129, 502-508
Development and validation of a bioanalytical method for five antidepressants in human milk by LC–MS
- 1 September 2016
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 129, 502-508
Development and validation of a bioanalytical method for five antidepressants in human milk by LC–MS
- 1 September 2016
- Published by Elsevier in Clinical Biochemistry
- Vol. 49 (13-14) , 1096-1103
Cocaine and crack cocaine abuse by pregnant or lactating mothers and analysis of its biomarkers in meconium and breast milk by LC–MS—A review
- 1 September 2016
- Published by Elsevier in Clinical Biochemistry
- Vol. 49 (13-14) , 1096-1103
Cocaine and crack cocaine abuse by pregnant or lactating mothers and analysis of its biomarkers in meconium and breast milk by LC–MS—A review
- 1 February 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1012-1013, 113-117
Analysis of cocaine/crack biomarkers in meconium by LC–MS
- 1 February 2016
- Published by Elsevier in Journal of Chromatography B
- Vol. 1012-1013, 113-117
Analysis of cocaine/crack biomarkers in meconium by LC–MS
- 1 January 2015
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 103, 67-72
Determination of cocaine/crack biomarkers in colostrum by LC–MS following protein precipitation
- 1 January 2015
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 103, 67-72
Determination of cocaine/crack biomarkers in colostrum by LC–MS following protein precipitation
- 16 July 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (18) , 4777-4784
A comparative study on the analytical performance of a charged aerosol detector and an ultraviolet detector for the RP-LC analysis of dabigatran etexilate in capsules
The reversed-phase liquid chromatography (RP-LC) method was validated for the assessment of dabigatran etexilate (DAB) in capsules using an ultraviolet detector (UV) and a charged aerosol detector (CAD) connected in series. The RP-LC method was carried out on a GL Sciences Inc. Inertsil ODS-2 column (250 mm × 4.6 mm I.D.). The mobile phase consisted of acetonitrile and ammonium acetate buffer (pH 5.5; 10 mM) (65 : 35, v/v) (flow rate 1.0 mL min−1). CAD detection was performed using a nitrogen pressure of 35 psi and a range of 100 pA and the UV detection at 225 nm. The chromatographic separation was obtained with a retention time of 6.7 min. Validation parameters such as specificity, linearity, precision, accuracy and robustness were evaluated. The method was linear over the concentration range of 1–70 μg mL−1 in both detectors. The specificity and stability-indicating capability of the method were proven through the degradation studies, which also show that there was no interference from the excipients. The method was precise and accurate, with the Plackett–Burman experimental design used to evaluate robustness, delivering results within the acceptable range. The method was successfully applied for DAB analysis and the results of the CAD and UV detectors were compared, showing a non-significant difference (P > 0.05).
- 16 July 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (18) , 4777-4784
A comparative study on the analytical performance of a charged aerosol detector and an ultraviolet detector for the RP-LC analysis of dabigatran etexilate in capsules
The reversed-phase liquid chromatography (RP-LC) method was validated for the assessment of dabigatran etexilate (DAB) in capsules using an ultraviolet detector (UV) and a charged aerosol detector (CAD) connected in series. The RP-LC method was carried out on a GL Sciences Inc. Inertsil ODS-2 column (250 mm × 4.6 mm I.D.). The mobile phase consisted of acetonitrile and ammonium acetate buffer (pH 5.5; 10 mM) (65 : 35, v/v) (flow rate 1.0 mL min−1). CAD detection was performed using a nitrogen pressure of 35 psi and a range of 100 pA and the UV detection at 225 nm. The chromatographic separation was obtained with a retention time of 6.7 min. Validation parameters such as specificity, linearity, precision, accuracy and robustness were evaluated. The method was linear over the concentration range of 1–70 μg mL−1 in both detectors. The specificity and stability-indicating capability of the method were proven through the degradation studies, which also show that there was no interference from the excipients. The method was precise and accurate, with the Plackett–Burman experimental design used to evaluate robustness, delivering results within the acceptable range. The method was successfully applied for DAB analysis and the results of the CAD and UV detectors were compared, showing a non-significant difference (P > 0.05).
- 10 March 2011
- Published by Springer Nature in Analytical Sciences
- Vol. 27 (3) , 265-270
Development and Validation of a Stability-indicating Capillary Zone Electrophoretic Method for the Assessment of Entecavir and Its Correlation with Liquid Chromatographic Methods
A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 μm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1 – 200 μg mL−1 (r2 = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).
- 10 March 2011
- Published by Springer Nature in Analytical Sciences
- Vol. 27 (3) , 265-270
Development and Validation of a Stability-indicating Capillary Zone Electrophoretic Method for the Assessment of Entecavir and Its Correlation with Liquid Chromatographic Methods
A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 μm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1 – 200 μg mL−1 (r2 = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).
- Open Access
- 1 September 2010
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 48 (8) , 641-646
Determination of Fluticasone Propionate in Nasal Sprays by a Validated Stability-Indicating MEKC Method
A micellar electrokinetic chromatography method (MEKC) is developed and validated for the analysis of fluticasone propionate (FP) in nasal sprays. The MEKC method is performed on a fused-silica capillary (50 µm i.d.; effective length, 40 cm). The background electrolyte consists of 25 mM borate and 25 mM anionic detergent SDS solution at pH 9. The capillary temperature is maintained at 35°C, and the applied voltage is 20 kV. The injection is performed using the hydrodynamic mode at 50 mbar for 6 s with detection at 238 nm. The method is linear in the range of 2–80 µg/mL (r2 = 0.9956). The specificity and stability-indicating capability are proven through forced degradation studies inclusive by mass spectrometry, which also shows that there is no interference of the excipients. The limit of detection and limit of quantitation are 0.56 and 2 µg/mL, respectively. Moreover, method validation demonstrates acceptable results for accuracy, precision, and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays, and the results were compared to a validated reversed-phase liquid chromatographic method, showing non-significant difference (P > 0.05).
- 1 September 2010
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 48 (8) , 641-646
Open AccessDetermination of Fluticasone Propionate in Nasal Sprays by a Validated Stability-Indicating MEKC Method
A micellar electrokinetic chromatography method (MEKC) is developed and validated for the analysis of fluticasone propionate (FP) in nasal sprays. The MEKC method is performed on a fused-silica capillary (50 µm i.d.; effective length, 40 cm). The background electrolyte consists of 25 mM borate and 25 mM anionic detergent SDS solution at pH 9. The capillary temperature is maintained at 35°C, and the applied voltage is 20 kV. The injection is performed using the hydrodynamic mode at 50 mbar for 6 s with detection at 238 nm. The method is linear in the range of 2–80 µg/mL (r2 = 0.9956). The specificity and stability-indicating capability are proven through forced degradation studies inclusive by mass spectrometry, which also shows that there is no interference of the excipients. The limit of detection and limit of quantitation are 0.56 and 2 µg/mL, respectively. Moreover, method validation demonstrates acceptable results for accuracy, precision, and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays, and the results were compared to a validated reversed-phase liquid chromatographic method, showing non-significant difference (P > 0.05).
- Open Access
- 1 January 2010
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 33 (1) , 124-129
Determination of phenobarbital in human plasma by a specific liquid chromatography method: application to a bioequivalence study
A liquid chromatography method was developed and validated for the determination of phenobarbital in human plasma using phenytoin as internal standard. The drugs were extracted from plasma by liquid-liquid extraction and separated isocratically on a C(12) analytical column, maintained at 35 degrees C, with water: acetonitrile: methanol (58.8:15.2:26, v/v/v) as mobile phase, run at a flow rate of 1.2 mL/min with detection at 205 nm. The method was linear in the range of 0.1-4 mu g/mL (r(2)=0.9999) and demonstrated acceptable results for the precision, accuracy and stability studies. The method was successfully applied for the bioequivalence study of two tablet formulations (test and reference) of phenobarbital 100 mg after single oral dose administration to healthy human volunteers
- 1 January 2010
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 33 (1) , 124-129
Open AccessDetermination of phenobarbital in human plasma by a specific liquid chromatography method: application to a bioequivalence study
A liquid chromatography method was developed and validated for the determination of phenobarbital in human plasma using phenytoin as internal standard. The drugs were extracted from plasma by liquid-liquid extraction and separated isocratically on a C(12) analytical column, maintained at 35 degrees C, with water: acetonitrile: methanol (58.8:15.2:26, v/v/v) as mobile phase, run at a flow rate of 1.2 mL/min with detection at 205 nm. The method was linear in the range of 0.1-4 mu g/mL (r(2)=0.9999) and demonstrated acceptable results for the precision, accuracy and stability studies. The method was successfully applied for the bioequivalence study of two tablet formulations (test and reference) of phenobarbital 100 mg after single oral dose administration to healthy human volunteers
- 1 October 2009
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 15 (6) , 723-730
A High-Throughput Liquid Chromatography Tandem Mass Spectrometry Method for the Comparative Determination of Fluticasone Propionate by Reversed-Phase Liquid Chromatography and Capillary Electrophoresis Methods in Pharmaceutical Nasal Sprays
A simple, specific, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of fluticasone propionate (FP) in pharmaceutical formulations was developed and validated using deflazacort as internal standard (IS). The LC-MS/MS method was carried out on a C8 column (50 mm) with a mobile phase consisted of methanol:water (95:5, v/v)–100 mM formic acid–50 mM ammonium acetate (90:5:5, v/v/v). The mass spectrometry method was performed employing positive atmospheric pressure chemical ionization technique, operating in multiple reaction monitoring mode. The chromatographic separation was obtained within 1.5 min and it was linear in the concentration range of 10–1000 ng mL−1. Moreover, method validation demonstrates acceptable results for the specificity, accuracy, precision and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays and the results were compared to validated liquid chromatography and capillary electrophoresis methods with photodiode array detectors showing non-significant difference ( P > 0.05).
- 1 October 2009
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 15 (6) , 723-730
A High-Throughput Liquid Chromatography Tandem Mass Spectrometry Method for the Comparative Determination of Fluticasone Propionate by Reversed-Phase Liquid Chromatography and Capillary Electrophoresis Methods in Pharmaceutical Nasal Sprays
A simple, specific, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of fluticasone propionate (FP) in pharmaceutical formulations was developed and validated using deflazacort as internal standard (IS). The LC-MS/MS method was carried out on a C8 column (50 mm) with a mobile phase consisted of methanol:water (95:5, v/v)–100 mM formic acid–50 mM ammonium acetate (90:5:5, v/v/v). The mass spectrometry method was performed employing positive atmospheric pressure chemical ionization technique, operating in multiple reaction monitoring mode. The chromatographic separation was obtained within 1.5 min and it was linear in the concentration range of 10–1000 ng mL−1. Moreover, method validation demonstrates acceptable results for the specificity, accuracy, precision and robustness. The proposed method was successfully applied for the quantitative analysis of FP nasal sprays and the results were compared to validated liquid chromatography and capillary electrophoresis methods with photodiode array detectors showing non-significant difference ( P > 0.05).
- 15 August 2009
- Published by Elsevier in Journal of Chromatography B
- Vol. 877 (24) , 2471-2476
Development and validation of a capillary zone electrophoresis method for assessment of recombinant human granulocyte colony-stimulating factor in pharmaceutical formulations and its correlation with liquid chromatography methods and bioassay
- 15 August 2009
- Published by Elsevier in Journal of Chromatography B
- Vol. 877 (24) , 2471-2476
Development and validation of a capillary zone electrophoresis method for assessment of recombinant human granulocyte colony-stimulating factor in pharmaceutical formulations and its correlation with liquid chromatography methods and bioassay