Alexandre Fournet
Research Subjects
Alexandre Fournet has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Mathieu Manassero
Service de Chirurgie École Nationale Vétérinaire d’Alfort
4 shared publications V. Viateau
Department of Small Animal Surgery École Nationale Vétérinaire d'Alfort Maisons‐Alfort France
2 shared publicationsVéronique Viateau
Centre Hospitalier Universitaire Vétérinaire d'Alfort (CHUVA), Université Paris Est, Ecole Nationale Vétérinaire d'Alfort, Maisons-Alfort, France
2 shared publicationsA. Decambron
Université Paris‐Est, Ecole Nationale Vétérinaire d'Alfort (Enva) 94700 Maisons‐Alfort France
1 shared publication- Adeline Decambron
Laboratoire de Bioingénierie et Bioimagerie Ostéo-Articulaire (B2OA-UMR CNRS 7052) Université Paris Diderot, 10 Avenue de Verdun, 75010, Paris, France
1 shared publication - Adeline Decambron
Ecole Nationale Vétérinaire d’Alfort, Université Paris-Est
1 shared publication
Latest Publications
- 1 March 2026
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 264 (3) , 1-8
Patellar ligament repair with ultra-high-molecular-weight polyethylene implant results in successful outcome in 9 dogs
Objective: To describe the outcomes of patellar ligament (PL) reconstruction with an ultra-high-molecular-weight polyethylene (UHMWPE) implant secured with an interference screw in dogs. Animals: Medical records from 7 referral centers were reviewed for dogs treated for PL rupture between 2021 and 2025. Cases treated exclusively with UHMWPE implants with a minimum follow-up of 6 months were included. Clinical Presentation: Dogs presented with lameness and examination findings consistent with PL rupture, confirmed by radiography in all cases. The data collected included diagnostic test findings, surgical technique, complications, follow-up, and outcomes. Canine Brief Pain Inventory scores were obtained at the final follow-up. Radiographic measurements were used to assess the patellar ligament length-to-patellar length ratio in operated and contralateral limbs over time. Results: 10 stifles from 9 dogs met the inclusion criteria. Median follow-up was 18 months (range, 1.5 to 3.8 years). No major complications were recorded. The patellar ligament length-to-patellar length ratio decreased after surgery. Return to activity was reported between 2 and 6 months postoperatively. Full function was recovered in 7 dogs; 2 dogs showed mild lameness beyond mid term. Canine Brief Pain Inventory scores in 8 dogs had a median of 4/100 (range, 0 to 26). Clinical Relevance: The UHMWPE implant provided effective repair without major complications in all 10 cases and resulted in acceptable to full functional outcomes in 9 dogs. The observed outcomes suggested that this technique could minimize the need for postoperative immobilization and may be associated with a low complication rate.
- 1 March 2026
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 264 (3) , 1-8
Patellar ligament repair with ultra-high-molecular-weight polyethylene implant results in successful outcome in 9 dogs
Objective: To describe the outcomes of patellar ligament (PL) reconstruction with an ultra-high-molecular-weight polyethylene (UHMWPE) implant secured with an interference screw in dogs. Animals: Medical records from 7 referral centers were reviewed for dogs treated for PL rupture between 2021 and 2025. Cases treated exclusively with UHMWPE implants with a minimum follow-up of 6 months were included. Clinical Presentation: Dogs presented with lameness and examination findings consistent with PL rupture, confirmed by radiography in all cases. The data collected included diagnostic test findings, surgical technique, complications, follow-up, and outcomes. Canine Brief Pain Inventory scores were obtained at the final follow-up. Radiographic measurements were used to assess the patellar ligament length-to-patellar length ratio in operated and contralateral limbs over time. Results: 10 stifles from 9 dogs met the inclusion criteria. Median follow-up was 18 months (range, 1.5 to 3.8 years). No major complications were recorded. The patellar ligament length-to-patellar length ratio decreased after surgery. Return to activity was reported between 2 and 6 months postoperatively. Full function was recovered in 7 dogs; 2 dogs showed mild lameness beyond mid term. Canine Brief Pain Inventory scores in 8 dogs had a median of 4/100 (range, 0 to 26). Clinical Relevance: The UHMWPE implant provided effective repair without major complications in all 10 cases and resulted in acceptable to full functional outcomes in 9 dogs. The observed outcomes suggested that this technique could minimize the need for postoperative immobilization and may be associated with a low complication rate.
- Open Access
- 17 June 2024
- Published by Wiley in Journal of Small Animal Practice
- Vol. 65 (9) , 694-703
Finney and Jaboulay pyloroplasties for the treatment of benign gastric outlet lesions in dogs and cats: technique and outcome in 13 cases (2015‐2024)
Objectives: To describe the use, complications and outcome of Finney or Jaboulay pyloroplasties for the treatment of benign gastric outlet lesions in dogs and cats.Materials and Methods: The medical records of dogs and cats surgically treated with Finney or Jaboulay pyloroplasty for benign gastric outflow tract disease in three institutions between January 1, 2015 and August 31, 2023 were retrospectively reviewed.Results: Eight dogs and five cats were diagnosed with benign obstructive or perforating gastric outlet lesions, including chronic hypertrophic pyloric gastropathy (n = 4), perforating pyloro‐duodenal peptic ulcer (4), sub‐obstructive pyloro‐duodenal eosinophilic sclerosing fibroplasia (2) and antral or proximal duodenal obstructive mass (3). Nine cases were treated using hand‐sewn Finney pyloroplasty and four cases were treated using stapled Jaboulay pyloroplasty. No major complications were recorded. Cases were followed for a median of 16.1 [11 to 29.6] months. At the last follow‐up, the outcome was excellent in all cases, with no clinical signs recorded and no medical treatment required.Clinical Significance: This case series suggests that Finney and Jaboulay pyloroplasties were safe and effective procedures for the surgical treatment of benign obstructive or perforating gastric outlet lesions in dogs and cats.
- 17 June 2024
- Published by Wiley in Journal of Small Animal Practice
- Vol. 65 (9) , 694-703
Open AccessFinney and Jaboulay pyloroplasties for the treatment of benign gastric outlet lesions in dogs and cats: technique and outcome in 13 cases (2015‐2024)
Objectives: To describe the use, complications and outcome of Finney or Jaboulay pyloroplasties for the treatment of benign gastric outlet lesions in dogs and cats.Materials and Methods: The medical records of dogs and cats surgically treated with Finney or Jaboulay pyloroplasty for benign gastric outflow tract disease in three institutions between January 1, 2015 and August 31, 2023 were retrospectively reviewed.Results: Eight dogs and five cats were diagnosed with benign obstructive or perforating gastric outlet lesions, including chronic hypertrophic pyloric gastropathy (n = 4), perforating pyloro‐duodenal peptic ulcer (4), sub‐obstructive pyloro‐duodenal eosinophilic sclerosing fibroplasia (2) and antral or proximal duodenal obstructive mass (3). Nine cases were treated using hand‐sewn Finney pyloroplasty and four cases were treated using stapled Jaboulay pyloroplasty. No major complications were recorded. Cases were followed for a median of 16.1 [11 to 29.6] months. At the last follow‐up, the outcome was excellent in all cases, with no clinical signs recorded and no medical treatment required.Clinical Significance: This case series suggests that Finney and Jaboulay pyloroplasties were safe and effective procedures for the surgical treatment of benign obstructive or perforating gastric outlet lesions in dogs and cats.
- 21 July 2020
- Published by Wiley in Journal of Small Animal Practice
- Vol. 62 (5) , 391-396
Treatment of urinary incontinence in a cat with genitourinary dysplasia using an urethral sphincter occluder
A 2‐year‐old spayed female Maine Coon presented with urinary incontinence and recurrent urinary tract infection since 2 months of age. Clinical examination was unremarkable. Ultrasonography, CT and cystourethroscopy revealed urogenital abnormalities consistent with genitourinary dysplasia. Urethral pressure profilometry suggested urethral sphincter mechanism incompetence. Surgical placement of an artificial urethral sphincter occluder was performed. Mild decrease of urinary incontinence was observed 6 weeks postoperatively. Inflation of the occluder under urethral pressure profilometry was subsequently performed and resolved the incontinence. This is the first report to describe the use of urodynamic testing at the time of inflation of an artificial urethral sphincter occluder to adjust the degree of urethral occlusion.
- 21 July 2020
- Published by Wiley in Journal of Small Animal Practice
- Vol. 62 (5) , 391-396
Treatment of urinary incontinence in a cat with genitourinary dysplasia using an urethral sphincter occluder
A 2‐year‐old spayed female Maine Coon presented with urinary incontinence and recurrent urinary tract infection since 2 months of age. Clinical examination was unremarkable. Ultrasonography, CT and cystourethroscopy revealed urogenital abnormalities consistent with genitourinary dysplasia. Urethral pressure profilometry suggested urethral sphincter mechanism incompetence. Surgical placement of an artificial urethral sphincter occluder was performed. Mild decrease of urinary incontinence was observed 6 weeks postoperatively. Inflation of the occluder under urethral pressure profilometry was subsequently performed and resolved the incontinence. This is the first report to describe the use of urodynamic testing at the time of inflation of an artificial urethral sphincter occluder to adjust the degree of urethral occlusion.
- 11 January 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (01) , 053-061
Stabilization of Olecranon Fractures by Tension Band Wiring or Plate Osteosynthesis: A Retrospective Study of 41 Cases
Objectives This article aimed to describe olecranon fracture in dogs and cats and their stabilization with tension band wiring or plate osteosynthesis, and to evaluate complications associated with each technique. Methods Medical records of cats and dogs that had been surgically treated for olecranon fractures with either tension band wiring or plate osteosynthesis were retrospectively reviewed. The surgical technique, complications and long-term outcomes were assessed. Results Forty-one olecranon fractures were included. Fractures were articular, comminuted and open in 90, 31 and 27% of cases, respectively. Tension band wiring and plate osteosynthesis were performed in 22 and 19 fractures, respectively. Complications occurred more commonly after tension band wiring (74%) compared with plate osteosynthesis (27%) (p = 0.002) and these were probably related to it being used in comminuted fractures (p = 0.01) or to errors in technique. Minor complications included Kirschner wires migration (n = 5), pain (n = 3), osteomyelitis (n = 3), skin breakdown (n = 3) and seroma (n = 1). Implant failure requiring further fixation (n = 4) was observed only in the tension band wiring group. Other major complications included skin wound debridement and closure (n = 1) and chronic lameness requiring implant removal (n = 7). Long-term functional outcomes were excellent regardless of the technique used. Clinical Significance Plate osteosynthesis should be performed for olecranon fracture repair if technically feasible.
- 11 January 2018
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 31 (01) , 053-061
Stabilization of Olecranon Fractures by Tension Band Wiring or Plate Osteosynthesis: A Retrospective Study of 41 Cases
Objectives This article aimed to describe olecranon fracture in dogs and cats and their stabilization with tension band wiring or plate osteosynthesis, and to evaluate complications associated with each technique. Methods Medical records of cats and dogs that had been surgically treated for olecranon fractures with either tension band wiring or plate osteosynthesis were retrospectively reviewed. The surgical technique, complications and long-term outcomes were assessed. Results Forty-one olecranon fractures were included. Fractures were articular, comminuted and open in 90, 31 and 27% of cases, respectively. Tension band wiring and plate osteosynthesis were performed in 22 and 19 fractures, respectively. Complications occurred more commonly after tension band wiring (74%) compared with plate osteosynthesis (27%) (p = 0.002) and these were probably related to it being used in comminuted fractures (p = 0.01) or to errors in technique. Minor complications included Kirschner wires migration (n = 5), pain (n = 3), osteomyelitis (n = 3), skin breakdown (n = 3) and seroma (n = 1). Implant failure requiring further fixation (n = 4) was observed only in the tension band wiring group. Other major complications included skin wound debridement and closure (n = 1) and chronic lameness requiring implant removal (n = 7). Long-term functional outcomes were excellent regardless of the technique used. Clinical Significance Plate osteosynthesis should be performed for olecranon fracture repair if technically feasible.
- 26 April 2017
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 35 (12) , 2637-2645
Low‐dose BMP‐2 and MSC dual delivery onto coral scaffold for critical‐size bone defect regeneration in sheep
Tissue‐engineered constructs (TECs) combining resorbable calcium‐based scaffolds and mesenchymal stem cells (MSCs) have the capability to regenerate large bone defects. Inconsistent results have, however, been observed, with a lack of osteoinductivity as a possible cause of failure. This study aimed to evaluate the impact of the addition of low‐dose bone morphogenetic protein‐2 (BMP‐2) to MSC‐coral‐TECs on the healing of clinically relevant segmental bone defects in sheep. Coral granules were either seeded with autologous MSCs (bone marrow‐derived) or loaded with BMP‐2. A 25‐mm‐long metatarsal bone defect was created and stabilized with a plate in 18 sheep. Defects were filled with one of the following TECs: (i) BMP (n = 5); (ii) MSC (n = 7); or (iii) MSC‐BMP (n = 6). Radiographic follow‐up was performed until animal sacrifice at 4 months. Bone formation and scaffold resorption were assessed by micro‐CT and histological analysis. Bone union with nearly complete scaffold resorption was observed in 1/5, 2/7, and 3/6 animals, when BMP‐, MSC‐, and MSC‐BMP‐TECs were implanted, respectively. The amount of newly formed bone was not statistically different between groups: 1074 mm3 [970–2478 mm3], 1155 mm3 [970–2595 mm3], and 2343 mm3 [931–3276 mm3] for BMP‐, MSC‐, and MSC‐BMP‐TECs, respectively. Increased scaffold resorption rate using BMP‐TECs was the only potential side effect observed. In conclusion, although the dual delivery of MSCs and BMP‐2 onto a coral scaffold further increased bone formation and bone union when compared to single treatment, results were non‐significant. Only 50% of the defects healed, demonstrating the need for further refinement of this strategy before clinical use. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2637–2645, 2017.
- 26 April 2017
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 35 (12) , 2637-2645
Low‐dose BMP‐2 and MSC dual delivery onto coral scaffold for critical‐size bone defect regeneration in sheep
Tissue‐engineered constructs (TECs) combining resorbable calcium‐based scaffolds and mesenchymal stem cells (MSCs) have the capability to regenerate large bone defects. Inconsistent results have, however, been observed, with a lack of osteoinductivity as a possible cause of failure. This study aimed to evaluate the impact of the addition of low‐dose bone morphogenetic protein‐2 (BMP‐2) to MSC‐coral‐TECs on the healing of clinically relevant segmental bone defects in sheep. Coral granules were either seeded with autologous MSCs (bone marrow‐derived) or loaded with BMP‐2. A 25‐mm‐long metatarsal bone defect was created and stabilized with a plate in 18 sheep. Defects were filled with one of the following TECs: (i) BMP (n = 5); (ii) MSC (n = 7); or (iii) MSC‐BMP (n = 6). Radiographic follow‐up was performed until animal sacrifice at 4 months. Bone formation and scaffold resorption were assessed by micro‐CT and histological analysis. Bone union with nearly complete scaffold resorption was observed in 1/5, 2/7, and 3/6 animals, when BMP‐, MSC‐, and MSC‐BMP‐TECs were implanted, respectively. The amount of newly formed bone was not statistically different between groups: 1074 mm3 [970–2478 mm3], 1155 mm3 [970–2595 mm3], and 2343 mm3 [931–3276 mm3] for BMP‐, MSC‐, and MSC‐BMP‐TECs, respectively. Increased scaffold resorption rate using BMP‐TECs was the only potential side effect observed. In conclusion, although the dual delivery of MSCs and BMP‐2 onto a coral scaffold further increased bone formation and bone union when compared to single treatment, results were non‐significant. Only 50% of the defects healed, demonstrating the need for further refinement of this strategy before clinical use. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2637–2645, 2017.