Aashish Priye
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aashish Priye has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Salar Balou
Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, Ohio 45221, United States
4 shared publicationsIsteaque Ahmed
Department of Chemical and Environmental Engineering
3 shared publications- Isteaque Ahmed
Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
2 shared publications - Manaswini Masetty
Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
2 shared publications - Satheesh Natarajan
Department of Nuclear Engineering, The Pennsylvania State University, University Park, PA 16802, USA
2 shared publications - Alex Laman
Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
1 shared publication
Latest Publications
- 1 October 2025
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 11 (11) , 6621-6632
3D-Printed Stent-Like Polymeric Structures with Tunable Mechanical Properties and Ionic Conductivity for Reinforced Nerve Guidance Conduits
Peripheral nerve injuries present a critical clinical challenge, particularly when bridging larger defects that exceed the capacity of conventional grafts. Although electrospun poly(vinylidene fluoride-trifluoroethylene) (PVDF-TrFE) nerve guidance conduits (NGCs) provide a promising solution due to their piezoelectric properties and extracellular matrix-mimicking structure, in electrospun scaffold form, they lack the mechanical strength to resist luminal collapse and compressive forces from surrounding tissues. Here, we report a stent-inspired approach to reinforce PVDF-TrFE conduits by integrating 3D-printed polymer lattices composed of poly(ethylene glycol) diacrylate (PEGDA) and ethylene glycol polyether acrylate (EGPEA). By modulating the EGPEA:PEGDA ratio, we tailored the mechanical stiffness, swelling behavior, and ionic conductivity of the photocurable resin, yielding structural designs that effectively support PVDF-TrFE conduits. Mechanical testing and finite element analysis (FEA) demonstrated that hexagonal lattice geometries significantly reduced stress concentrations and enhanced yield strength under physiologically relevant pressures compared to rectangular controls. Additionally, the PEG moieties facilitated ion transport through the reinforcement structures, a property with the potential to modulate the local electrochemical environment and amplify the piezoelectric advantages of PVDF-TrFE. We demonstrated the resin's biocompatibility through fibroblast assays, showing no significant reduction in cell viability or morphological disruption compared to controls following a 24-h ethanol wash. Taken together, this work establishes a material-level proof-of-concept that integrates mechanical reinforcement with ionic transport in a piezoelectric conduit platform for enhanced peripheral nerve regeneration.
- 1 October 2025
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 11 (11) , 6621-6632
3D-Printed Stent-Like Polymeric Structures with Tunable Mechanical Properties and Ionic Conductivity for Reinforced Nerve Guidance Conduits
Peripheral nerve injuries present a critical clinical challenge, particularly when bridging larger defects that exceed the capacity of conventional grafts. Although electrospun poly(vinylidene fluoride-trifluoroethylene) (PVDF-TrFE) nerve guidance conduits (NGCs) provide a promising solution due to their piezoelectric properties and extracellular matrix-mimicking structure, in electrospun scaffold form, they lack the mechanical strength to resist luminal collapse and compressive forces from surrounding tissues. Here, we report a stent-inspired approach to reinforce PVDF-TrFE conduits by integrating 3D-printed polymer lattices composed of poly(ethylene glycol) diacrylate (PEGDA) and ethylene glycol polyether acrylate (EGPEA). By modulating the EGPEA:PEGDA ratio, we tailored the mechanical stiffness, swelling behavior, and ionic conductivity of the photocurable resin, yielding structural designs that effectively support PVDF-TrFE conduits. Mechanical testing and finite element analysis (FEA) demonstrated that hexagonal lattice geometries significantly reduced stress concentrations and enhanced yield strength under physiologically relevant pressures compared to rectangular controls. Additionally, the PEG moieties facilitated ion transport through the reinforcement structures, a property with the potential to modulate the local electrochemical environment and amplify the piezoelectric advantages of PVDF-TrFE. We demonstrated the resin's biocompatibility through fibroblast assays, showing no significant reduction in cell viability or morphological disruption compared to controls following a 24-h ethanol wash. Taken together, this work establishes a material-level proof-of-concept that integrates mechanical reinforcement with ionic transport in a piezoelectric conduit platform for enhanced peripheral nerve regeneration.
- 6 August 2025
- Published by Wiley in Environmental Quality Management
- Vol. 35 (1)
Life Cycle Assessment of Waste Source‐Derived Chemicals as Adsorbents
Life cycle assessment (LCA) of the current environmental scenario can be evaluated in terms of cradle‐cradle. The basic understanding of cradle‐cradle refers to the different phases of analysis, recovery, reusability, sustainability, and circular economy of any prospective work. Currently, wastewater treatment is one of the most widely researched topics across the globe due to its adverse environmental impacts. A detailed study on the environmental impacts of adequate utilization of waste‐derived adsorbents in the wastewater treatment processes is also analyzed through LCA studies that are defined by ISO‐14000, which is a comprehensive set of standards for environmental management. The selection of a proper adsorbent for wastewater treatment studies is one of the major aspects to be concentrated on. Hence, the adsorbents derived from various waste materials will aid in the development of low‐cost pilot scales of wastewater treatment and also lead to the enhancement of a circular economy that maintains a proper life cycle assessment of these novel chemicals. It is also mentioned that the replacement of these conventional adsorbents with various other non‐conventional adsorbents will aid in maintaining a clean and green sustainable environment in terms of circular economy concepts, reduce, recycle, and reuse. From these studies, it is concluded that a gradual reduction in the continuous rise of energy demand and the development of a clean and sustainable environment can be maintained.
- 6 August 2025
- Published by Wiley in Environmental Quality Management
- Vol. 35 (1)
Life Cycle Assessment of Waste Source‐Derived Chemicals as Adsorbents
Life cycle assessment (LCA) of the current environmental scenario can be evaluated in terms of cradle‐cradle. The basic understanding of cradle‐cradle refers to the different phases of analysis, recovery, reusability, sustainability, and circular economy of any prospective work. Currently, wastewater treatment is one of the most widely researched topics across the globe due to its adverse environmental impacts. A detailed study on the environmental impacts of adequate utilization of waste‐derived adsorbents in the wastewater treatment processes is also analyzed through LCA studies that are defined by ISO‐14000, which is a comprehensive set of standards for environmental management. The selection of a proper adsorbent for wastewater treatment studies is one of the major aspects to be concentrated on. Hence, the adsorbents derived from various waste materials will aid in the development of low‐cost pilot scales of wastewater treatment and also lead to the enhancement of a circular economy that maintains a proper life cycle assessment of these novel chemicals. It is also mentioned that the replacement of these conventional adsorbents with various other non‐conventional adsorbents will aid in maintaining a clean and green sustainable environment in terms of circular economy concepts, reduce, recycle, and reuse. From these studies, it is concluded that a gradual reduction in the continuous rise of energy demand and the development of a clean and sustainable environment can be maintained.
- Open Access
- 24 February 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (6) , 1187-1194
A steam-mediated isothermal amplification and flocculation-based detection platform for electricity-free point of care diagnostics
Approximately 9% of the global population lacks access to reliable electricity, and the absence of affordable, electricity-free diagnostic tools hinders early detection of infectious diseases, exacerbating public health burdens in resource-limited settings. We introduce SteamFloc-LAMP – an electricity-free molecular diagnostic platform engineered for instrument-free detection of pathogenic nucleic acid targets. The platform leverages steam-mediated heating from boiling water to sustain the isothermal conditions required for Loop-Mediated Isothermal Amplification (LAMP). Thermal characterization of the steam-mediated heating system identified parameters that enable the consistent maintenance of optimal temperatures for LAMP reactions with minimal fluctuations. Visual end-point detection was achieved through a bridging flocculation mechanism, which exploits the interaction between LAMP amplicons, spermine, and charcoal particles, leading to visible aggregation in positive samples, thus enabling naked-eye detection without the need for specialized equipment or expensive reagents like fluorophores or colorimetric dyes. The SteamFloc-LAMP assay targeted the lipL32 gene, recognized for its exclusivity to pathogenic Leptospira strains. The assay achieved a detection limit of 100 fg of genomic DNA per reaction (∼90 genome copies). Specificity tests using lipL32-specific primers demonstrated the assay's ability to distinguish pathogenic Leptospira accurately, with no cross-reactivity with ligB, ligA, or lipL41 genes found in nonpathogenic strains. A blind test involving DNA extracted from Leptospira reference cultures further validated the assay's diagnostic accuracy, aligning with PCR results. These findings demonstrate the SteamFloc-LAMP assay as a reliable, simple, and cost-effective field deployable diagnostic tool with significant implications for point-of-care detection.
- 24 February 2025
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 150 (6) , 1187-1194
Open AccessA steam-mediated isothermal amplification and flocculation-based detection platform for electricity-free point of care diagnostics
Approximately 9% of the global population lacks access to reliable electricity, and the absence of affordable, electricity-free diagnostic tools hinders early detection of infectious diseases, exacerbating public health burdens in resource-limited settings. We introduce SteamFloc-LAMP – an electricity-free molecular diagnostic platform engineered for instrument-free detection of pathogenic nucleic acid targets. The platform leverages steam-mediated heating from boiling water to sustain the isothermal conditions required for Loop-Mediated Isothermal Amplification (LAMP). Thermal characterization of the steam-mediated heating system identified parameters that enable the consistent maintenance of optimal temperatures for LAMP reactions with minimal fluctuations. Visual end-point detection was achieved through a bridging flocculation mechanism, which exploits the interaction between LAMP amplicons, spermine, and charcoal particles, leading to visible aggregation in positive samples, thus enabling naked-eye detection without the need for specialized equipment or expensive reagents like fluorophores or colorimetric dyes. The SteamFloc-LAMP assay targeted the lipL32 gene, recognized for its exclusivity to pathogenic Leptospira strains. The assay achieved a detection limit of 100 fg of genomic DNA per reaction (∼90 genome copies). Specificity tests using lipL32-specific primers demonstrated the assay's ability to distinguish pathogenic Leptospira accurately, with no cross-reactivity with ligB, ligA, or lipL41 genes found in nonpathogenic strains. A blind test involving DNA extracted from Leptospira reference cultures further validated the assay's diagnostic accuracy, aligning with PCR results. These findings demonstrate the SteamFloc-LAMP assay as a reliable, simple, and cost-effective field deployable diagnostic tool with significant implications for point-of-care detection.
- 20 February 2025
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 102 (3) , 1138-1145
Development and Implementation of a Low-Cost 3D-Printed Rotational Viscometer for Rheology and Fluid Mechanics Education
- 20 February 2025
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 102 (3) , 1138-1145
Development and Implementation of a Low-Cost 3D-Printed Rotational Viscometer for Rheology and Fluid Mechanics Education
- Top Cited PapersOpen Access
- 17 April 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 257, 116292
Paper-based loop-mediated isothermal amplification and CRISPR integrated platform for on-site nucleic acid testing of pathogens
- 17 April 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 257, 116292
Top Cited PapersOpen AccessPaper-based loop-mediated isothermal amplification and CRISPR integrated platform for on-site nucleic acid testing of pathogens
- Open Access
- 27 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (11) , 1993
Enhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification
Accurate quantification of immunoglobulin G (IgG) levels is vital for understanding immune status and diagnosing various medical conditions. Lateral flow assays (LFAs) offer rapid and convenient diagnostic tools, but their sensitivity has been a limitation. Our research introduces a refined method incorporating europium nanoparticles, enhancing both sensitivity and accuracy of LFAs in human IgG measurement. Utilizing a unique sandwich format, carboxylate-modified polystyrene Eu (III) chelate microparticles (CM-EUs) acted as the primary reporters. The concentrations of both detection and capture antibodies on the strip were optimized to bolster the LFA’s quantitative performance. The subsequent calibration curve between the IgG concentration and the measured intensity ratio (VR) established the linearity and analytical sensitivity of our method with a high correlation coefficient (r = 0.99) and an impressively low limit of detection (LoD = 0.04 ng/mL). Our precision assessment, segmented into intra-assay and inter-assay evaluations, showcases the method’s consistency and reproducibility. The LFA assay’s stability was established by demonstrating its resistance to degradation and affirming its potential for extended storage without a dip in performance. The study’s findings underscore the potential of this method to contribute to diagnostic medicine and improve patient care.
- 27 October 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (11) , 1993
Open AccessEnhancing the Sensitivity of Lateral Flow Assay with Europium Nanoparticles for Accurate Human IgG Quantification
Accurate quantification of immunoglobulin G (IgG) levels is vital for understanding immune status and diagnosing various medical conditions. Lateral flow assays (LFAs) offer rapid and convenient diagnostic tools, but their sensitivity has been a limitation. Our research introduces a refined method incorporating europium nanoparticles, enhancing both sensitivity and accuracy of LFAs in human IgG measurement. Utilizing a unique sandwich format, carboxylate-modified polystyrene Eu (III) chelate microparticles (CM-EUs) acted as the primary reporters. The concentrations of both detection and capture antibodies on the strip were optimized to bolster the LFA’s quantitative performance. The subsequent calibration curve between the IgG concentration and the measured intensity ratio (VR) established the linearity and analytical sensitivity of our method with a high correlation coefficient (r = 0.99) and an impressively low limit of detection (LoD = 0.04 ng/mL). Our precision assessment, segmented into intra-assay and inter-assay evaluations, showcases the method’s consistency and reproducibility. The LFA assay’s stability was established by demonstrating its resistance to degradation and affirming its potential for extended storage without a dip in performance. The study’s findings underscore the potential of this method to contribute to diagnostic medicine and improve patient care.
- 23 October 2023
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 62 (44) , 18780-18791
Harnessing Wind with a Passive Direct Air Capture (PDAC) System for CO2 Capture: Insights from Computational Fluid Dynamics Modeling
- 23 October 2023
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 62 (44) , 18780-18791
Harnessing Wind with a Passive Direct Air Capture (PDAC) System for CO2 Capture: Insights from Computational Fluid Dynamics Modeling
- Open Access
A Smartphone-Enabled Continuous Flow Digital Droplet LAMP Platform for High Throughput and Inexpensive Quantitative Detection of Nucleic Acid Targets
Molecular tests for infectious diseases and genetic anomalies, which account for significant global morbidity and mortality, are central to nucleic acid analysis. In this study, we present a digital droplet LAMP (ddLAMP) platform that offers a cost-effective and portable solution for such assays. Our approach integrates disposable 3D-printed droplet generator chips with a consumer smartphone equipped with a custom image analysis application for conducting ddLAMP assays, thereby eliminating the necessity for expensive and complicated photolithographic techniques, optical microscopes, or flow cytometers. Our 3D printing technique for microfluidic chips facilitates rapid chip fabrication in under 2 h, without the complications of photolithography or chip bonding. The platform’s heating mechanism incorporates low-powered miniature heating blocks with dual resistive cartridges, ensuring rapid and accurate temperature modulation in a compact form. Instrumentation is further simplified by integrating miniaturized magnification and fluorescence optics with a smartphone camera. The fluorescence quantification benefits from our previously established RGB to CIE-xyY transformation, enhancing signal dynamic range. Performance assessment of our ddLAMP system revealed a limit of detection at 10 copies/μL, spanning a dynamic range up to 104 copies/μL. Notably, experimentally determined values of the fraction of positive droplets for varying DNA concentrations aligned with the anticipated exponential trend per Poisson statistics. Our holistic ddLAMP platform, inclusive of chip production, heating, and smartphone-based droplet evaluation, provides a refined method compatible with standard laboratory environments, alleviating the challenges of traditional photolithographic methods and intricate droplet microfluidics expertise.
Open AccessA Smartphone-Enabled Continuous Flow Digital Droplet LAMP Platform for High Throughput and Inexpensive Quantitative Detection of Nucleic Acid Targets
Molecular tests for infectious diseases and genetic anomalies, which account for significant global morbidity and mortality, are central to nucleic acid analysis. In this study, we present a digital droplet LAMP (ddLAMP) platform that offers a cost-effective and portable solution for such assays. Our approach integrates disposable 3D-printed droplet generator chips with a consumer smartphone equipped with a custom image analysis application for conducting ddLAMP assays, thereby eliminating the necessity for expensive and complicated photolithographic techniques, optical microscopes, or flow cytometers. Our 3D printing technique for microfluidic chips facilitates rapid chip fabrication in under 2 h, without the complications of photolithography or chip bonding. The platform’s heating mechanism incorporates low-powered miniature heating blocks with dual resistive cartridges, ensuring rapid and accurate temperature modulation in a compact form. Instrumentation is further simplified by integrating miniaturized magnification and fluorescence optics with a smartphone camera. The fluorescence quantification benefits from our previously established RGB to CIE-xyY transformation, enhancing signal dynamic range. Performance assessment of our ddLAMP system revealed a limit of detection at 10 copies/μL, spanning a dynamic range up to 104 copies/μL. Notably, experimentally determined values of the fraction of positive droplets for varying DNA concentrations aligned with the anticipated exponential trend per Poisson statistics. Our holistic ddLAMP platform, inclusive of chip production, heating, and smartphone-based droplet evaluation, provides a refined method compatible with standard laboratory environments, alleviating the challenges of traditional photolithographic methods and intricate droplet microfluidics expertise.
- Open Access
Miniaturized Non-Contact Heating and Transmitted Light Imaging Using an Inexpensive and Modular 3D-Printed Platform for Molecular Diagnostics
The ability to simultaneously heat and image samples using transmitted light is crucial for several biological applications. However, existing techniques such as heated stage microscopes, thermal cyclers equipped with imaging capabilities, or non-contact heating systems are often bulky, expensive, and complex. This work presents the development and characterization of a Miniaturized Optically-clear Thermal Enclosure (MOTE) system—an open-source, inexpensive, and low-powered modular system—capable of convectively heating samples while simultaneously imaging them with transmitted light. We develop and validate a computational fluid dynamics (CFD) model to design and optimize the heating chamber. The model simulates velocity and temperature profiles within the heating chamber for various chamber materials and sizes. The computational model yielded an optimal chamber dimension capable of achieving a stable temperature ranging from ambient to 95 °C with a spatial discrepancy of less than 1.5 °C, utilizing less than 8.5 W of power. The dual-functionality of the MOTE system, enabling synchronous heating and transmitted light imaging, was demonstrated through the successful execution of paper-based LAMP reactions to detect λ DNA samples in real-time down to 10 copies/µL of the target concentration. The MOTE system offers a promising and flexible platform for various applications, from molecular diagnostics to biochemical analyses, cell biology, genomics, and education.
Open AccessMiniaturized Non-Contact Heating and Transmitted Light Imaging Using an Inexpensive and Modular 3D-Printed Platform for Molecular Diagnostics
The ability to simultaneously heat and image samples using transmitted light is crucial for several biological applications. However, existing techniques such as heated stage microscopes, thermal cyclers equipped with imaging capabilities, or non-contact heating systems are often bulky, expensive, and complex. This work presents the development and characterization of a Miniaturized Optically-clear Thermal Enclosure (MOTE) system—an open-source, inexpensive, and low-powered modular system—capable of convectively heating samples while simultaneously imaging them with transmitted light. We develop and validate a computational fluid dynamics (CFD) model to design and optimize the heating chamber. The model simulates velocity and temperature profiles within the heating chamber for various chamber materials and sizes. The computational model yielded an optimal chamber dimension capable of achieving a stable temperature ranging from ambient to 95 °C with a spatial discrepancy of less than 1.5 °C, utilizing less than 8.5 W of power. The dual-functionality of the MOTE system, enabling synchronous heating and transmitted light imaging, was demonstrated through the successful execution of paper-based LAMP reactions to detect λ DNA samples in real-time down to 10 copies/µL of the target concentration. The MOTE system offers a promising and flexible platform for various applications, from molecular diagnostics to biochemical analyses, cell biology, genomics, and education.
- 14 August 2023
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 11 (34) , 12667-12676
From Waste to Filament: Development of Biomass-Derived Activated Carbon-Reinforced PETG Composites for Sustainable 3D Printing
- 14 August 2023
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 11 (34) , 12667-12676
From Waste to Filament: Development of Biomass-Derived Activated Carbon-Reinforced PETG Composites for Sustainable 3D Printing