Rogério R. Gerbatin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rogério R. Gerbatin has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Catherine Mooney
University College Dublin, Dublin, Ireland
1 shared publication - Cristina R. Reschke
FutureNeuro Research Ireland Centre Royal College of Surgeons in Ireland Dublin Ireland
1 shared publication - David Clifford Henshall
Department of Physiology & Medical Physics, RCSI University of Medicine and Health Sciences, Dublin, Ireland
1 shared publication - Federico Del Gallo
Department of Neuroscience, Biomedicine and Movement Sciences, University of Verona, Verona, Italy
1 shared publication - Fernando Dobrachinski
Universidade Federal de Santa Maria
1 shared publication Félix A.A. Soares
Department of Biochemistry and Molecular Biology, Center for Natural and Exact Sciences, Federal University of Santa Maria, Santa Maria, RS, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 October 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056060
Detection of spontaneous seizures in EEGs in multiple experimental mouse models of epilepsy
Objective. Electroencephalography (EEG) is a key tool for non-invasive recording of brain activity and the diagnosis of epilepsy. EEG monitoring is also widely employed in rodent models to track epilepsy development and evaluate experimental therapies and interventions. Whereas automated seizure detection algorithms have been developed for clinical EEG, preclinical versions face challenges of inter-model differences and lack of EEG standardization, leaving researchers relying on time-consuming visual annotation of signals. Approach. In this study, a machine learning-based seizure detection approach, ‘Epi-AI’, which can semi-automate EEG analysis in multiple mouse models of epilepsy was developed. Twenty-six mice with a total EEG recording duration of 6451 h were used to develop and test the Epi-AI approach. EEG recordings were obtained from two mouse models of kainic acid-induced epilepsy (Models I and III), a genetic model of Dravet syndrome (Model II) and a pilocarpine mouse model of epilepsy (Model IV). The Epi-AI algorithm was compared against two threshold-based approaches for seizure detection, a local Teager-Kaiser energy operator (TKEO) approach and a global Teager-Kaiser energy operator-discrete wavelet transform (TKEO-DWT) combination approach. Main results. Epi-AI demonstrated a superior sensitivity, 91.4%–98.8%, and specificity, 93.1%–98.8%, in Models I–III, to both of the threshold-based approaches which performed well on individual mouse models but did not generalise well across models. The performance of the TKEO approach in Models I–III ranged from 66.9%–91.3% sensitivity and 60.8%–97.5% specificity to detect spontaneous seizures when compared with expert annotations. The sensitivity and specificity of the TKEO-DWT approach were marginally better than the TKEO approach in Models I–III at 73.2%–80.1% and 75.8%–98.1%, respectively. When tested on EEG from Model IV which was not used in developing the Epi-AI approach, Epi-AI was able to identify seizures with 76.3% sensitivity and 98.1% specificity. Significance. Epi-AI has the potential to provide fast, objective and reproducible semi-automated analysis of multiple types of seizure in long-duration EEG recordings in rodents.
- 1 October 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (5) , 056060
Open AccessDetection of spontaneous seizures in EEGs in multiple experimental mouse models of epilepsy
Objective. Electroencephalography (EEG) is a key tool for non-invasive recording of brain activity and the diagnosis of epilepsy. EEG monitoring is also widely employed in rodent models to track epilepsy development and evaluate experimental therapies and interventions. Whereas automated seizure detection algorithms have been developed for clinical EEG, preclinical versions face challenges of inter-model differences and lack of EEG standardization, leaving researchers relying on time-consuming visual annotation of signals. Approach. In this study, a machine learning-based seizure detection approach, ‘Epi-AI’, which can semi-automate EEG analysis in multiple mouse models of epilepsy was developed. Twenty-six mice with a total EEG recording duration of 6451 h were used to develop and test the Epi-AI approach. EEG recordings were obtained from two mouse models of kainic acid-induced epilepsy (Models I and III), a genetic model of Dravet syndrome (Model II) and a pilocarpine mouse model of epilepsy (Model IV). The Epi-AI algorithm was compared against two threshold-based approaches for seizure detection, a local Teager-Kaiser energy operator (TKEO) approach and a global Teager-Kaiser energy operator-discrete wavelet transform (TKEO-DWT) combination approach. Main results. Epi-AI demonstrated a superior sensitivity, 91.4%–98.8%, and specificity, 93.1%–98.8%, in Models I–III, to both of the threshold-based approaches which performed well on individual mouse models but did not generalise well across models. The performance of the TKEO approach in Models I–III ranged from 66.9%–91.3% sensitivity and 60.8%–97.5% specificity to detect spontaneous seizures when compared with expert annotations. The sensitivity and specificity of the TKEO-DWT approach were marginally better than the TKEO approach in Models I–III at 73.2%–80.1% and 75.8%–98.1%, respectively. When tested on EEG from Model IV which was not used in developing the Epi-AI approach, Epi-AI was able to identify seizures with 76.3% sensitivity and 98.1% specificity. Significance. Epi-AI has the potential to provide fast, objective and reproducible semi-automated analysis of multiple types of seizure in long-duration EEG recordings in rodents.
- 1 June 2019
- Published by Elsevier in Neuroscience Letters
- Vol. 704, 141-144
A1 rather than A2A adenosine receptor as a possible target of Guanosine effects on mitochondrial dysfunction following Traumatic Brain Injury in rats
- 1 June 2019
- Published by Elsevier in Neuroscience Letters
- Vol. 704, 141-144
A1 rather than A2A adenosine receptor as a possible target of Guanosine effects on mitochondrial dysfunction following Traumatic Brain Injury in rats