Chan-Jin Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chan-Jin Park has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Lee-Ra Cho
Department of Prosthodontics & Research Institute of Oral Science, College of Dentistry, Kangwon National University, Gangneung, Republic of Korea
80 shared publications - Yoon-Hyuk Huh
Department of Prosthodontics & Research Institute of Oral Science, College of Dentistry, Kangwon National University, Gangneung, Republic of Korea
73 shared publications - Kyung-Ho Ko
Department of Prosthodontics & Research Institute of Oral Science, College of Dentistry, Kangwon National University, Gangneung, Republic of Korea
57 shared publications Lee-Ra Cho
Gangneung Wonju Natl Univ, Dept Prosthodont, Kangnung, South Korea
13 shared publicationsDae-Gon Kim
12 shared publications- Hyeon-Goo Kang
Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
8 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by Korean Academy of Stomatognathic Function and Occlusion in Journal of Dental Rehabilitation and Applied Science
- Vol. 42 (3) , 166-180
A review on the chewing side preference: etiology, clinical implications and assessment methods
Seung-Woo Lee, Seung-Seok Chi, Kyung-Ho Ko, Yoon-Hyuk Huh, Lee-Ra Cho, Chan-Jin Park. J Dent Rehabil Appl Sci 2026;42:166-80. https://doi.org/10.14368/jdras.2026.42.3.166
- 31 August 2026
- Published by Korean Academy of Stomatognathic Function and Occlusion in Journal of Dental Rehabilitation and Applied Science
- Vol. 42 (3) , 166-180
Open AccessA review on the chewing side preference: etiology, clinical implications and assessment methods
Seung-Woo Lee, Seung-Seok Chi, Kyung-Ho Ko, Yoon-Hyuk Huh, Lee-Ra Cho, Chan-Jin Park. J Dent Rehabil Appl Sci 2026;42:166-80. https://doi.org/10.14368/jdras.2026.42.3.166
- Open Access
- 31 August 2026
- Published by Korean Academy of Stomatognathic Function and Occlusion in Journal of Dental Rehabilitation and Applied Science
- Vol. 42 (3) , 153-165
Zirconia design, milling, and sintering process affecting the fit of restorations
Sun-Ho Kim, Kyung-Ho Ko, Yoon-Hyuk Huh, Lee-Ra Cho, Chan-Jin Park. J Dent Rehabil Appl Sci 2026;42:153-65. https://doi.org/10.14368/jdras.2026.42.3.153
- 31 August 2026
- Published by Korean Academy of Stomatognathic Function and Occlusion in Journal of Dental Rehabilitation and Applied Science
- Vol. 42 (3) , 153-165
Open AccessZirconia design, milling, and sintering process affecting the fit of restorations
Sun-Ho Kim, Kyung-Ho Ko, Yoon-Hyuk Huh, Lee-Ra Cho, Chan-Jin Park. J Dent Rehabil Appl Sci 2026;42:153-65. https://doi.org/10.14368/jdras.2026.42.3.153
- Open Access
- 21 August 2026
- Published by Wiley in Journal of Prosthodontics
Effect of metal framework design on the fracture resistance of implant‐supported metal–ceramic crowns fabricated by selective laser melting
Purpose: To evaluate the fracture resistance of implant‐supported metal–ceramic crowns fabricated using selective laser melting (SLM), according to the metal support height around the screw access hole (SAH) and the substructure design. Materials and Methods: Metal–ceramic crowns and rectangular bilayer specimens were fabricated using SLM in two independent experimental series. In the SAH design series, the substructure design was kept constant while the metal support height around the SAH was varied (none, half, and complete metal support; n = 12 per group). In the substructure design series, the SAH configuration was held constant (complete metal support), and the metal substructure design was varied (uniform cut‐back, lingual support, and circumferential ring support; n = 12 per group). Crown specimens underwent thermomechanical aging (50 N, 100,000 cycles, 2 Hz, 5°C–55°C), followed by fracture resistance testing, Weibull analysis, failure mode classification, and fractographic analysis. Rectangular bilayer specimens representing each framework design were used for edge‐chipping evaluation. Statistical analyses used one‐way ANOVA and Tukey HSD tests (α = 0.05). Results: The complete metal support SAH design showed significantly greater fracture resistance than the other SAH configurations ( p < 0.05). However, in the corresponding rectangular bilayer specimens, this design showed the lowest edge‐chipping resistance among the SAH configurations. Fractographic analysis showed that fractures originated at the occlusal loading site and propagated toward the crown margin. Among substructure designs, the circumferential ring design exhibited significantly greater fracture resistance and superior edge‐chipping resistance compared with other designs ( p < 0.05). Conclusions: Complete metal support around the SAH improved fracture resistance. Loading close to the SAH may increase susceptibility to veneering ceramic chipping under the tested conditions. A circumferential ring design providing uniform ceramic support enhanced overall mechanical performance.
- 21 August 2026
- Published by Wiley in Journal of Prosthodontics
Open AccessEffect of metal framework design on the fracture resistance of implant‐supported metal–ceramic crowns fabricated by selective laser melting
Purpose: To evaluate the fracture resistance of implant‐supported metal–ceramic crowns fabricated using selective laser melting (SLM), according to the metal support height around the screw access hole (SAH) and the substructure design. Materials and Methods: Metal–ceramic crowns and rectangular bilayer specimens were fabricated using SLM in two independent experimental series. In the SAH design series, the substructure design was kept constant while the metal support height around the SAH was varied (none, half, and complete metal support; n = 12 per group). In the substructure design series, the SAH configuration was held constant (complete metal support), and the metal substructure design was varied (uniform cut‐back, lingual support, and circumferential ring support; n = 12 per group). Crown specimens underwent thermomechanical aging (50 N, 100,000 cycles, 2 Hz, 5°C–55°C), followed by fracture resistance testing, Weibull analysis, failure mode classification, and fractographic analysis. Rectangular bilayer specimens representing each framework design were used for edge‐chipping evaluation. Statistical analyses used one‐way ANOVA and Tukey HSD tests (α = 0.05). Results: The complete metal support SAH design showed significantly greater fracture resistance than the other SAH configurations ( p < 0.05). However, in the corresponding rectangular bilayer specimens, this design showed the lowest edge‐chipping resistance among the SAH configurations. Fractographic analysis showed that fractures originated at the occlusal loading site and propagated toward the crown margin. Among substructure designs, the circumferential ring design exhibited significantly greater fracture resistance and superior edge‐chipping resistance compared with other designs ( p < 0.05). Conclusions: Complete metal support around the SAH improved fracture resistance. Loading close to the SAH may increase susceptibility to veneering ceramic chipping under the tested conditions. A circumferential ring design providing uniform ceramic support enhanced overall mechanical performance.
- Open Access
Effect of Laser Surface Texturing on Bond Strength and Mechanical Properties of 3Y and 5Y Zirconia
This study evaluated the influence of various surface treatments on the bonding performance and mechanical behavior of zirconia, with particular emphasis on the effect of laser surface texturing (LST) compared with conventional 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) and airborne particle abrasion (APA) methods. Two zirconia compositions, 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) and 5 mol% partially stabilized zirconia (5Y-PSZ), were subjected to four surface treatment protocols: as-milled, 10-MDP, APA, and LST (n = 12). Shear bond strength (SBS) to titanium and biaxial flexural strength (BFS) of zirconia were measured. Surface morphology, failure mode, and phase composition were analyzed using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and X-ray diffraction (XRD). Data were analyzed with two-way ANOVA and Tukey’s post hoc test (α = 0.05), and the reliability of flexural strength was assessed using Weibull analysis. Surface treatment significantly affected SBS (p < 0.05). The LST groups exhibited the highest SBS values and a higher proportion of mixed failures, whereas other groups predominantly showed adhesive failures. However, LST-treated specimens, particularly 5Y-PSZ, showed reduced BFS. XRD confirmed phase stability, although localized microstructural changes were observed after LST. LST enhanced the zirconia–titanium interfacial bond strength and promoted mixed failure modes; however, this improvement was accompanied by a reduction in flexural strength, particularly in 5Y-PSZ.
Open AccessEffect of Laser Surface Texturing on Bond Strength and Mechanical Properties of 3Y and 5Y Zirconia
This study evaluated the influence of various surface treatments on the bonding performance and mechanical behavior of zirconia, with particular emphasis on the effect of laser surface texturing (LST) compared with conventional 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) and airborne particle abrasion (APA) methods. Two zirconia compositions, 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) and 5 mol% partially stabilized zirconia (5Y-PSZ), were subjected to four surface treatment protocols: as-milled, 10-MDP, APA, and LST (n = 12). Shear bond strength (SBS) to titanium and biaxial flexural strength (BFS) of zirconia were measured. Surface morphology, failure mode, and phase composition were analyzed using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), and X-ray diffraction (XRD). Data were analyzed with two-way ANOVA and Tukey’s post hoc test (α = 0.05), and the reliability of flexural strength was assessed using Weibull analysis. Surface treatment significantly affected SBS (p < 0.05). The LST groups exhibited the highest SBS values and a higher proportion of mixed failures, whereas other groups predominantly showed adhesive failures. However, LST-treated specimens, particularly 5Y-PSZ, showed reduced BFS. XRD confirmed phase stability, although localized microstructural changes were observed after LST. LST enhanced the zirconia–titanium interfacial bond strength and promoted mixed failure modes; however, this improvement was accompanied by a reduction in flexural strength, particularly in 5Y-PSZ.
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (4) , 326-336
Influence of impression technique and screw access hole configuration on distortion in conventional impressions of prepared CAD-CAM abutment geometries
Cho SS, et al. J Adv Prosthodont. 2026 Aug;18(4):326-336. https://doi.org/10.4047/jap.2026.18.4.326
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (4) , 326-336
Open AccessInfluence of impression technique and screw access hole configuration on distortion in conventional impressions of prepared CAD-CAM abutment geometries
Cho SS, et al. J Adv Prosthodont. 2026 Aug;18(4):326-336. https://doi.org/10.4047/jap.2026.18.4.326
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (3) , 241-251
Effects of surface treatment and screw access hole filling method on the retention of CAD-CAM milled PMMA restoration
To evaluate the effects of titanium abutment surface treatment, screw access hole (SAH) filling method, and restoration internal surface treatment on the retention of CAD-CAM milled PMMA restorations. The study was conducted in two phases. First, the effects of abutment airborne particle abrasion (APA) and SAH filling method (full, partial) on retention were evaluated (n = 19). Second, the effect of PMMA internal surface treatment (no treatment, MDP-containing primer, APA) was evaluated (n = 19). All specimens were cemented with a non–eugenol temporary cement. Thermomechanical aging was performed prior to pull-out test. Surface characteristics were analyzed using scanning electron microscope (SEM) and atomic force microscope (AFM). Statistical analysis included one-way and two-way ANOVA, Tukey’s HSD test, multiple regression, and chi-square test (α = .05). Abutment APA significantly increased retention compared with untreated abutments (mean difference, 33.71 N; 95% CI, 21.34 to 46.08; P < .001), and partial SAH filling produced higher retention than full filling (mean difference, 13.54 N; 95% CI, 1.17 to 25.91; P = .033). PMMA internal surface treatment significantly affected retention, with MDP-containing primer treated PMMA showing the lowest values, whereas APA resulted in the highest (P < .05). SEM and AFM revealed smoothing of the PMMA intaglio surface after MDP-containing primer application and pronounced microroughness after APA. Within the limitations of this in vitro study, abutment APA may improve the retention of CAD-CAM milled PMMA restorations under the tested conditions, and partial SAH filling may provide an additional retention. In contrast, application of an MDP-containing primer to the PMMA internal surface may reduce retention.
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (3) , 241-251
Open AccessEffects of surface treatment and screw access hole filling method on the retention of CAD-CAM milled PMMA restoration
To evaluate the effects of titanium abutment surface treatment, screw access hole (SAH) filling method, and restoration internal surface treatment on the retention of CAD-CAM milled PMMA restorations. The study was conducted in two phases. First, the effects of abutment airborne particle abrasion (APA) and SAH filling method (full, partial) on retention were evaluated (n = 19). Second, the effect of PMMA internal surface treatment (no treatment, MDP-containing primer, APA) was evaluated (n = 19). All specimens were cemented with a non–eugenol temporary cement. Thermomechanical aging was performed prior to pull-out test. Surface characteristics were analyzed using scanning electron microscope (SEM) and atomic force microscope (AFM). Statistical analysis included one-way and two-way ANOVA, Tukey’s HSD test, multiple regression, and chi-square test (α = .05). Abutment APA significantly increased retention compared with untreated abutments (mean difference, 33.71 N; 95% CI, 21.34 to 46.08; P < .001), and partial SAH filling produced higher retention than full filling (mean difference, 13.54 N; 95% CI, 1.17 to 25.91; P = .033). PMMA internal surface treatment significantly affected retention, with MDP-containing primer treated PMMA showing the lowest values, whereas APA resulted in the highest (P < .05). SEM and AFM revealed smoothing of the PMMA intaglio surface after MDP-containing primer application and pronounced microroughness after APA. Within the limitations of this in vitro study, abutment APA may improve the retention of CAD-CAM milled PMMA restorations under the tested conditions, and partial SAH filling may provide an additional retention. In contrast, application of an MDP-containing primer to the PMMA internal surface may reduce retention.
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 64 (1)
Prosthetic rehabilitation of traumatized maxillary anterior teeth using a digital workflow: a case report
- 1 January 2026
- Published by XMLink in The Journal of Korean Academy of Prosthodontics
- Vol. 64 (1)
Open AccessProsthetic rehabilitation of traumatized maxillary anterior teeth using a digital workflow: a case report
- 31 December 2025
- Published by Korean Society for Dental Materials in Korean Journal of Dental Materials
- Vol. 52 (4) , 343-356
Comparative analysis of translucency and flexural strength in heterogeneous and homogeneous multilayered dental zirconia
본 연구의 목적은 이트리아 함량과 구조적 설계(이종 조성 대 동종 조성)를 달리한 다층 구조 치과용 지르코니아의 투광도, 복굴절, 이축굴곡 강도 및 비커스 경도를 평가하는 것이다. 본 연구에서는 두 종류의 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) 대조군(IPS e.max ZirCAD [IPS], Zirtooth Fulluster [ZTF])과 세 종류의 다층 구조 지르코니아 실험군을 선정하였다. 실험군은 이종 조성 구조인 Zirtooth Multiluster (ZTM)와 동종 조성 구조인 Zirtooth MultiNeo (ZTN), Zirtooth UltraLuster (ZTU)로 구성되었다. 분광광도계를 이용하여 투광도를 측정하였으며, 광학적 등방성을 평가하기 위해 복굴절을 분석하였다. 이축 굴곡 강도와 비커스 경도는 ISO 6872 규격에 의거하여 측정하였다. 주사전자현미경(SEM)과 X선 회절 분석(XRD)을 통해 미세구조와 결정상을 분석하였다. 그 결과, 동종 조성인 ZTU 그룹이 가장 높은 투광도와 가장 낮은 복굴절을 나타냈다 (p<0.05). ZTN 그룹은 가장 높은 이축 굴곡 강도(1741.62±138.55 MPa)를 보였다. 비커스 경도는 그룹 간 통계적으로 유의한 차이가 없었다. 본 연구의 한계 내에서, 동종 조성의 4Y-PSZ 기반 ZTN 그룹은 우수한 기계적 강도를 보여 높은 교합력이 가해지는 구치부 수복에 적합하다. ZTU 그룹은 뛰어난 투광도와 광학적 등방성을 나타내어 심미적인 전치부 수복에 적합한 것으로 판단된다.
- 31 December 2025
- Published by Korean Society for Dental Materials in Korean Journal of Dental Materials
- Vol. 52 (4) , 343-356
Comparative analysis of translucency and flexural strength in heterogeneous and homogeneous multilayered dental zirconia
본 연구의 목적은 이트리아 함량과 구조적 설계(이종 조성 대 동종 조성)를 달리한 다층 구조 치과용 지르코니아의 투광도, 복굴절, 이축굴곡 강도 및 비커스 경도를 평가하는 것이다. 본 연구에서는 두 종류의 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) 대조군(IPS e.max ZirCAD [IPS], Zirtooth Fulluster [ZTF])과 세 종류의 다층 구조 지르코니아 실험군을 선정하였다. 실험군은 이종 조성 구조인 Zirtooth Multiluster (ZTM)와 동종 조성 구조인 Zirtooth MultiNeo (ZTN), Zirtooth UltraLuster (ZTU)로 구성되었다. 분광광도계를 이용하여 투광도를 측정하였으며, 광학적 등방성을 평가하기 위해 복굴절을 분석하였다. 이축 굴곡 강도와 비커스 경도는 ISO 6872 규격에 의거하여 측정하였다. 주사전자현미경(SEM)과 X선 회절 분석(XRD)을 통해 미세구조와 결정상을 분석하였다. 그 결과, 동종 조성인 ZTU 그룹이 가장 높은 투광도와 가장 낮은 복굴절을 나타냈다 (p<0.05). ZTN 그룹은 가장 높은 이축 굴곡 강도(1741.62±138.55 MPa)를 보였다. 비커스 경도는 그룹 간 통계적으로 유의한 차이가 없었다. 본 연구의 한계 내에서, 동종 조성의 4Y-PSZ 기반 ZTN 그룹은 우수한 기계적 강도를 보여 높은 교합력이 가해지는 구치부 수복에 적합하다. ZTU 그룹은 뛰어난 투광도와 광학적 등방성을 나타내어 심미적인 전치부 수복에 적합한 것으로 판단된다.
- 8 December 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (6) , 1015-1019
Digital facial analysis for prosthodontic rehabilitation of a patient with decreased vertical dimension of occlusion associated with severe tooth wear: A clinical report
- 8 December 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (6) , 1015-1019
Digital facial analysis for prosthodontic rehabilitation of a patient with decreased vertical dimension of occlusion associated with severe tooth wear: A clinical report
- Open Access
- 31 August 2025
- Published by Korean Academy of Stomatognathic Function and Occlusion in Journal of Dental Rehabilitation and Applied Science
- Vol. 41 (3) , 217-230
Prosthetic rehabilitation using digital facebow transfer for severely erosive dentition caused by bulimia nervosa
Seong-Soo Cho, Kyung-Ho Ko, Yoon-Hyuk Huh, Lee-Ra Cho, Chan-Jin Park. J Dent Rehabil Appl Sci 2025;41:217-30. https://doi.org/10.14368/jdras.2025.41.3.217
- 31 August 2025
- Published by Korean Academy of Stomatognathic Function and Occlusion in Journal of Dental Rehabilitation and Applied Science
- Vol. 41 (3) , 217-230
Open AccessProsthetic rehabilitation using digital facebow transfer for severely erosive dentition caused by bulimia nervosa
Seong-Soo Cho, Kyung-Ho Ko, Yoon-Hyuk Huh, Lee-Ra Cho, Chan-Jin Park. J Dent Rehabil Appl Sci 2025;41:217-30. https://doi.org/10.14368/jdras.2025.41.3.217