Wendy Marie Murray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wendy Marie Murray has a total of 134 co-authors. Here are the top co-authors by number of shared publications:
- Katherine R. Saul
North Carolina State University
9 shared publications - Eric Jon Perreault
Northwestern University
8 shared publications - Jennifer A. Nichols
J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, USA
8 shared publications Michael S. Bednar
Edward Hines, Jr. VA Hospital, Hines, IL, USA
7 shared publicationsSarah J. Wohlman
Department of Biomedical Engineering, Northwestern University, USA
7 shared publicationsVincent R. Hentz
Veterans Affairs Palo Alto Health Care System, Palo Alto, CA; Department of Surgery, Stanford University, Palo Alto, CA
7 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 207
Arm and shoulder muscle segmentation in axial MRI with UNet deep learning model
- 1 September 2026
- Published by Elsevier in Journal of Biomechanics
- Vol. 207
Open AccessArm and shoulder muscle segmentation in axial MRI with UNet deep learning model
- Open Access
High-density surface EMG grid enables non-invasive characterization of intrinsic hand muscles activity
Understanding the neuromuscular properties that allow dexterous manipulation of objects remains a major challenge in neurorehabilitation, largely due to the difficulty of characterizing intrinsic hand muscle activity. These muscles are small, densely packed, and anatomically complex, making selective recordings with intramuscular electromyography (EMG) technically demanding and impractical for comprehensive studies. In this work, we present a custom, high-density (HD) surface EMG grid designed to non-invasively capture activity from intrinsic hand muscles from both dorsal and palmar surfaces. We evaluated the quality and spatial selectivity of the recordings by directly comparing them with intramuscular EMG signals obtained from the dorsal and palmar interossei. Surface EMG signals corresponded closely to the intramuscular recordings, with high correlation values for all subjects and tasks. Double differential spatial filtering significantly improved selectivity, although some residual volume conduction remained. The dorsal grid primarily captured dorsal interossei activity, while the palmar grid was more sensitive to lumbrical activation. The palmar interossei recordings were spatially more varied, with the second palmar interosseous predominantly detected on the dorsal grid and the third and fourth on the palmar grid. Together, these results demonstrate that non-invasive HD surface EMG will allow more complete measurement of intrinsic muscle activity, to provide a better understanding of the complex relation between the intrinsic and extrinsic hand muscles during dexterous movements. This basic information will allow refinement of biomechanical hand models and prosthetic devices, and the development of biomimetic brain computer interfaces aimed at restoring natural hand function after neurological injury.
Open AccessHigh-density surface EMG grid enables non-invasive characterization of intrinsic hand muscles activity
Understanding the neuromuscular properties that allow dexterous manipulation of objects remains a major challenge in neurorehabilitation, largely due to the difficulty of characterizing intrinsic hand muscle activity. These muscles are small, densely packed, and anatomically complex, making selective recordings with intramuscular electromyography (EMG) technically demanding and impractical for comprehensive studies. In this work, we present a custom, high-density (HD) surface EMG grid designed to non-invasively capture activity from intrinsic hand muscles from both dorsal and palmar surfaces. We evaluated the quality and spatial selectivity of the recordings by directly comparing them with intramuscular EMG signals obtained from the dorsal and palmar interossei. Surface EMG signals corresponded closely to the intramuscular recordings, with high correlation values for all subjects and tasks. Double differential spatial filtering significantly improved selectivity, although some residual volume conduction remained. The dorsal grid primarily captured dorsal interossei activity, while the palmar grid was more sensitive to lumbrical activation. The palmar interossei recordings were spatially more varied, with the second palmar interosseous predominantly detected on the dorsal grid and the third and fourth on the palmar grid. Together, these results demonstrate that non-invasive HD surface EMG will allow more complete measurement of intrinsic muscle activity, to provide a better understanding of the complex relation between the intrinsic and extrinsic hand muscles during dexterous movements. This basic information will allow refinement of biomechanical hand models and prosthetic devices, and the development of biomimetic brain computer interfaces aimed at restoring natural hand function after neurological injury.
- Open Access
Muscle-driven hand simulations emphasize the critical role of the extensor mechanism
Biomechanical simulations of complex hand motions remain scarce, due to challenges that span computation and data acquisition. Using a computer vision-based motion capture approach, a 23-degree of freedom musculoskeletal model, and direct collocation optimization, we performed muscle-driven simulations to track hand kinematics from 7 participants performing American Sign Language gestures. While proximal joints were tracked accurately, interphalangeal joint tracking was significantly worse, with a consistent flexion bias. Modifications to finger extensor muscle paths that incorporated the dual-inserting nature of the extensors improved accuracy, suggesting better representation of extensor force distribution across distal joints may be necessary for accurate hand simulations.
Open AccessMuscle-driven hand simulations emphasize the critical role of the extensor mechanism
Biomechanical simulations of complex hand motions remain scarce, due to challenges that span computation and data acquisition. Using a computer vision-based motion capture approach, a 23-degree of freedom musculoskeletal model, and direct collocation optimization, we performed muscle-driven simulations to track hand kinematics from 7 participants performing American Sign Language gestures. While proximal joints were tracked accurately, interphalangeal joint tracking was significantly worse, with a consistent flexion bias. Modifications to finger extensor muscle paths that incorporated the dual-inserting nature of the extensors improved accuracy, suggesting better representation of extensor force distribution across distal joints may be necessary for accurate hand simulations.
- Open Access
Soft, 3D printed muscle ultrasound phantom with structurally tunable B-mode echo intensity
OBJECTIVES: Imaging phantoms for training and validation are vital to improving the performance and adoption of ultrasound imaging modalities in clinical and pre-clinical applications, and the goal of this study was to assess the viability of 3D printed muscle ultrasound phantoms to meet this need. METHODS: We used a soft stereolithography resin to 3D print phantoms that mimicked the fascicle- and perimysium-scale structure of skeletal muscle and compared the long axis B-mode imaging quality and pattern of the phantom to that of healthy, adult Biceps brachii. We used a pulse-echo, time-of-flight method to measure the acoustic impedance of the resin for comparison to skeletal muscle and common soft tissue mimicking materials. We analyzed the echo intensity (EI) of muscle images to establish a physiological range and compared the EI of different phantom designs to assess the ability to control imaging brightness through structural modification. RESULTS: A linear, striated hyper-/hypo-echoic B-mode imaging pattern mimicking long axis Biceps brachii muscle images was achieved with two 3D structure paradigms, rod and honeycomb. Acoustic impedance of Elastic 50A resin is higher than skeletal muscle in bulk, but appears suitable for use in a 3D structured phantom. EI measured in the Biceps images were found to vary both within and across images with an overall mean ± SD of 87 ±13 AU. EI measured in honeycomb phantoms (55 ±15 AU) was higher than in rod phantoms (42 ±13 AU), and a latticed honeycomb further increased EI (90 ±11 AU). CONCLUSIONS: This study serves as proof-of-concept for soft, 3D printed phantoms that replicate the characteristic muscle ultrasound imaging pattern with the ability to tune clinically relevant EI values via structural design.
Open AccessSoft, 3D printed muscle ultrasound phantom with structurally tunable B-mode echo intensity
OBJECTIVES: Imaging phantoms for training and validation are vital to improving the performance and adoption of ultrasound imaging modalities in clinical and pre-clinical applications, and the goal of this study was to assess the viability of 3D printed muscle ultrasound phantoms to meet this need. METHODS: We used a soft stereolithography resin to 3D print phantoms that mimicked the fascicle- and perimysium-scale structure of skeletal muscle and compared the long axis B-mode imaging quality and pattern of the phantom to that of healthy, adult Biceps brachii. We used a pulse-echo, time-of-flight method to measure the acoustic impedance of the resin for comparison to skeletal muscle and common soft tissue mimicking materials. We analyzed the echo intensity (EI) of muscle images to establish a physiological range and compared the EI of different phantom designs to assess the ability to control imaging brightness through structural modification. RESULTS: A linear, striated hyper-/hypo-echoic B-mode imaging pattern mimicking long axis Biceps brachii muscle images was achieved with two 3D structure paradigms, rod and honeycomb. Acoustic impedance of Elastic 50A resin is higher than skeletal muscle in bulk, but appears suitable for use in a 3D structured phantom. EI measured in the Biceps images were found to vary both within and across images with an overall mean ± SD of 87 ±13 AU. EI measured in honeycomb phantoms (55 ±15 AU) was higher than in rod phantoms (42 ±13 AU), and a latticed honeycomb further increased EI (90 ±11 AU). CONCLUSIONS: This study serves as proof-of-concept for soft, 3D printed phantoms that replicate the characteristic muscle ultrasound imaging pattern with the ability to tune clinically relevant EI values via structural design.
- Open Access
- 10 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (2) , 497-512
Sensitivity analyses of probabilistic and deterministic DTI tractography methodologies for studying arm muscle architecture
Purpose: To determine the sensitivity profiles of probabilistic and deterministic DTI tractography methods in estimating geometric properties in arm muscle anatomy.Methods: Spin‐echo diffusion‐weighted MR images were acquired in the dominant arm of 10 participants. Both deterministic and probabilistic tractography were performed in two different muscle architectures of the parallel‐structured biceps brachii (and the pennate‐structured flexor carpi ulnaris. Muscle fascicle geometry estimates and number of fascicles were evaluated with respect to tractography turning angle, polynomial fitting order, and SNR. The DTI tractography estimated fascicle lengths were compared with measurements obtained from conventional cadaveric dissection and ultrasound modalities.Results: The probabilistic method generally estimated fascicle lengths closer to ranges reported by conventional methods than the deterministic method, most evident in the biceps brachii (p > 0.05), consisting of longer, arc‐like fascicles. For both methods, a wide turning angle (50º–90°) generated fascicle lengths that were in close agreement with conventional methods, most evident in the flexor carpi ulnaris (p > 0.05), consisting of shorter, feather‐like fascicles. The probabilistic approach produced at least two times more fascicles than the deterministic approach. For both approaches, second‐order fitting yielded about double the complete tracts as third‐order fitting. In both muscles, as SNR decreased, deterministic tractography produced less fascicles but consistent geometry (p > 0.05), whereas probabilistic tractography produced a consistent number but altered geometry of fascicles (p < 0.001).Conclusion: Findings from this study provide best practice recommendations for implementing DTI tractography in skeletal muscle and will inform future in vivo studies of healthy and pathological muscle structure.
- 10 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (2) , 497-512
Open AccessSensitivity analyses of probabilistic and deterministic DTI tractography methodologies for studying arm muscle architecture
Purpose: To determine the sensitivity profiles of probabilistic and deterministic DTI tractography methods in estimating geometric properties in arm muscle anatomy.Methods: Spin‐echo diffusion‐weighted MR images were acquired in the dominant arm of 10 participants. Both deterministic and probabilistic tractography were performed in two different muscle architectures of the parallel‐structured biceps brachii (and the pennate‐structured flexor carpi ulnaris. Muscle fascicle geometry estimates and number of fascicles were evaluated with respect to tractography turning angle, polynomial fitting order, and SNR. The DTI tractography estimated fascicle lengths were compared with measurements obtained from conventional cadaveric dissection and ultrasound modalities.Results: The probabilistic method generally estimated fascicle lengths closer to ranges reported by conventional methods than the deterministic method, most evident in the biceps brachii (p > 0.05), consisting of longer, arc‐like fascicles. For both methods, a wide turning angle (50º–90°) generated fascicle lengths that were in close agreement with conventional methods, most evident in the flexor carpi ulnaris (p > 0.05), consisting of shorter, feather‐like fascicles. The probabilistic approach produced at least two times more fascicles than the deterministic approach. For both approaches, second‐order fitting yielded about double the complete tracts as third‐order fitting. In both muscles, as SNR decreased, deterministic tractography produced less fascicles but consistent geometry (p > 0.05), whereas probabilistic tractography produced a consistent number but altered geometry of fascicles (p < 0.001).Conclusion: Findings from this study provide best practice recommendations for implementing DTI tractography in skeletal muscle and will inform future in vivo studies of healthy and pathological muscle structure.
- 22 February 2023
- Published by Elsevier in Journal of Biomechanics
- Vol. 151, 111501
Multi-sweep 3-dimensional ultrasound is accurate for in vivo muscle volume quantification, expanding use to larger muscles
- 22 February 2023
- Published by Elsevier in Journal of Biomechanics
- Vol. 151, 111501
Multi-sweep 3-dimensional ultrasound is accurate for in vivo muscle volume quantification, expanding use to larger muscles
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (5) , 1424-1435
A Musculoskeletal Model of the Hand and Wrist Capable of Simulating Functional Tasks
Objective: The purpose of this work was to develop an open-source musculoskeletal model of the hand and wrist and to evaluate its performance during simulations of functional tasks. Methods: The current model was developed by adapting and expanding upon existing models. An optimal control theory framework that combines forward-dynamics simulations with a simulated-annealing optimization was used to simulate maximum grip and pinch force. Active and passive hand opening were simulated to evaluate coordinated kinematic hand movements. Results: The model's maximum grip force production matched experimental measures of grip force, force distribution amongst the digits, and displayed sensitivity to wrist flexion. Simulated lateral pinch strength replicated in vivo palmar pinch strength data. Additionally, predicted activations for 7 of 8 muscles fell within variability of EMG data during palmar pinch. The active and passive hand opening simulations predicted reasonable activations and demonstrated passive motion mimicking tenodesis, respectively. Conclusion: This work advances simulation capabilities of hand and wrist models and provides a foundation for future work to build upon. Significance: This is the first open-source musculoskeletal model of the hand and wrist to be implemented during both functional kinetic and kinematic tasks. We provide a novel simulation framework to predict maximal grip and pinch force which can be used to evaluate how potential surgical and rehabilitation interventions influence these functional outcomes while requiring minimal experimental data.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (5) , 1424-1435
A Musculoskeletal Model of the Hand and Wrist Capable of Simulating Functional Tasks
Objective: The purpose of this work was to develop an open-source musculoskeletal model of the hand and wrist and to evaluate its performance during simulations of functional tasks. Methods: The current model was developed by adapting and expanding upon existing models. An optimal control theory framework that combines forward-dynamics simulations with a simulated-annealing optimization was used to simulate maximum grip and pinch force. Active and passive hand opening were simulated to evaluate coordinated kinematic hand movements. Results: The model's maximum grip force production matched experimental measures of grip force, force distribution amongst the digits, and displayed sensitivity to wrist flexion. Simulated lateral pinch strength replicated in vivo palmar pinch strength data. Additionally, predicted activations for 7 of 8 muscles fell within variability of EMG data during palmar pinch. The active and passive hand opening simulations predicted reasonable activations and demonstrated passive motion mimicking tenodesis, respectively. Conclusion: This work advances simulation capabilities of hand and wrist models and provides a foundation for future work to build upon. Significance: This is the first open-source musculoskeletal model of the hand and wrist to be implemented during both functional kinetic and kinematic tasks. We provide a novel simulation framework to predict maximal grip and pinch force which can be used to evaluate how potential surgical and rehabilitation interventions influence these functional outcomes while requiring minimal experimental data.
- Open Access
- 8 February 2022
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12, 817334
Variability of in vivo Sarcomere Length Measures in the Upper Limb Obtained With Second Harmonic Generation Microendoscopy
The lengths of a muscle’s sarcomeres are a primary determinant of its ability to contract and produce force. In addition, sarcomere length is a critical parameter that is required to make meaningful comparisons of both the force-generating and excursion capacities of different muscles. Until recently, in vivo sarcomere length data have been limited to invasive or intraoperative measurement techniques. With the advent of second harmonic generation microendoscopy, minimally invasive measures of sarcomere length can be made for the first time. This imaging technique expands our ability to study muscle adaptation due to changes in stimulus, use, or disease. However, due to past inability to measure sarcomeres outside of surgery or biopsy, little is known about the natural, anatomical variability in sarcomere length in living human subjects. To develop robust experimental protocols that ensure data provide accurate representations of a muscle’s sarcomere lengths, we sought to quantify experimental uncertainty associated with in vivo measures of sarcomere lengths. Specifically, we assessed the variability in sarcomere length measured (1) within a single image, along a muscle fiber, (2) across images captured within a single trial, across trials, and across days, as well as (3) across locations in the muscle using second harmonic generation in two upper limb muscles with different muscle architectures, functions, and sizes. Across all of our measures of variability we estimate that the magnitude of the uncertainty for in vivo sarcomere length is on the order of ∼0.25 μm. In the two upper limb muscles studied we found larger variability in sarcomere lengths within a single insertion than across locations. We also developed custom code to make measures of sarcomere length variability across a single fiber and determined that this codes’ accuracy is an order of magnitude smaller than our measurement uncertainty due to sarcomere variability. Together, our findings provide guidance for the development of robust experimental design and analysis of in vivo sarcomere lengths in the upper limb.
- 8 February 2022
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 12, 817334
Open AccessVariability of in vivo Sarcomere Length Measures in the Upper Limb Obtained With Second Harmonic Generation Microendoscopy
The lengths of a muscle’s sarcomeres are a primary determinant of its ability to contract and produce force. In addition, sarcomere length is a critical parameter that is required to make meaningful comparisons of both the force-generating and excursion capacities of different muscles. Until recently, in vivo sarcomere length data have been limited to invasive or intraoperative measurement techniques. With the advent of second harmonic generation microendoscopy, minimally invasive measures of sarcomere length can be made for the first time. This imaging technique expands our ability to study muscle adaptation due to changes in stimulus, use, or disease. However, due to past inability to measure sarcomeres outside of surgery or biopsy, little is known about the natural, anatomical variability in sarcomere length in living human subjects. To develop robust experimental protocols that ensure data provide accurate representations of a muscle’s sarcomere lengths, we sought to quantify experimental uncertainty associated with in vivo measures of sarcomere lengths. Specifically, we assessed the variability in sarcomere length measured (1) within a single image, along a muscle fiber, (2) across images captured within a single trial, across trials, and across days, as well as (3) across locations in the muscle using second harmonic generation in two upper limb muscles with different muscle architectures, functions, and sizes. Across all of our measures of variability we estimate that the magnitude of the uncertainty for in vivo sarcomere length is on the order of ∼0.25 μm. In the two upper limb muscles studied we found larger variability in sarcomere lengths within a single insertion than across locations. We also developed custom code to make measures of sarcomere length variability across a single fiber and determined that this codes’ accuracy is an order of magnitude smaller than our measurement uncertainty due to sarcomere variability. Together, our findings provide guidance for the development of robust experimental design and analysis of in vivo sarcomere lengths in the upper limb.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Multi-Sweep 3-Dimensional Ultrasound is Accurate for in Vivo Muscle Volume Quantification, Expanding Use to Larger Muscles
Muscle volume is an important parameter in analyzing three-dimensional structure of muscle-tendon units. Three-dimensional ultrasound (3DUS) enables excellent quantification of muscle volume in small muscles; however, when a muscle’s cross sectional area is larger than the field of view of the ultrasound transducer at any point along its length, more than one sweep is necessary to reconstruct muscle anatomy. Confounding image registration errors have been reported between multiple sweeps. Here, we detail imaging phantom studies used to (1) define an acquisition protocol that reduces misalignment in 3D reconstruction caused by muscle deformation, and (2) quantify accuracy of 3DUS for measures of volume when phantoms are too large to be fully imaged via a single transducer sweep. Finally, we (3) establish the feasibility of our protocol for in vivo measures by comparing biceps brachii muscle volumes using 3DUS and magnetic resonance imaging (MRI). Phantom studies indicate operator intent to use constant pressure across multiple sweeps effectively mitigates image misalignment, yielding minimal volume error (1.70 ± 1.30%). Intentional application of different pressure between sweeps replicated discontinuity observed previously, leading to larger errors (5.30 ± 0.94%). Based on these findings, we adopted a gel bag standoff and acquired in vivo images of biceps brachii muscles using 3DUS and compared this volume to MRI. We did not observe misalignment errors and there were no significant differences between imaging modalities (-0.71 ± 5.03%), indicating 3DUS can reliably be used to quantify muscle volume in larger muscles requiring multiple transducer sweeps.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessMulti-Sweep 3-Dimensional Ultrasound is Accurate for in Vivo Muscle Volume Quantification, Expanding Use to Larger Muscles
Muscle volume is an important parameter in analyzing three-dimensional structure of muscle-tendon units. Three-dimensional ultrasound (3DUS) enables excellent quantification of muscle volume in small muscles; however, when a muscle’s cross sectional area is larger than the field of view of the ultrasound transducer at any point along its length, more than one sweep is necessary to reconstruct muscle anatomy. Confounding image registration errors have been reported between multiple sweeps. Here, we detail imaging phantom studies used to (1) define an acquisition protocol that reduces misalignment in 3D reconstruction caused by muscle deformation, and (2) quantify accuracy of 3DUS for measures of volume when phantoms are too large to be fully imaged via a single transducer sweep. Finally, we (3) establish the feasibility of our protocol for in vivo measures by comparing biceps brachii muscle volumes using 3DUS and magnetic resonance imaging (MRI). Phantom studies indicate operator intent to use constant pressure across multiple sweeps effectively mitigates image misalignment, yielding minimal volume error (1.70 ± 1.30%). Intentional application of different pressure between sweeps replicated discontinuity observed previously, leading to larger errors (5.30 ± 0.94%). Based on these findings, we adopted a gel bag standoff and acquired in vivo images of biceps brachii muscles using 3DUS and compared this volume to MRI. We did not observe misalignment errors and there were no significant differences between imaging modalities (-0.71 ± 5.03%), indicating 3DUS can reliably be used to quantify muscle volume in larger muscles requiring multiple transducer sweeps.
- Open Access
A Musculoskeletal Model of the Hand and Wrist Capable of Simulating Functional Tasks
Objective: The purpose of this work was to develop an open-source musculoskeletal model of the hand and wrist and to evaluate its performance during simulations of functional tasks. Methods: The musculoskeletal model was developed by adapting and expanding upon existing musculoskeletal models. An optimal control theory framework that combines forward-dynamics simulations with a simulated-annealing optimization was used to simulate maximum grip and pinch force. Active and passive hand opening were simulated to evaluate coordinated kinematic hand movements. Results: The model’s maximum grip force production matched experimental measures of grip force, force distribution amongst the digits, and displayed sensitivity to wrist flexion. Simulated lateral pinch strength fell within variability of in vivo palmar pinch strength data. Additionally, predicted activation for 7 of 8 muscles fell within variability of EMG data during palmar pinch. The active and passive hand opening simulations predicted reasonable activations and demonstrated passive motion mimicking tenodesis, respectively. Conclusion: This work advances simulation capabilities of hand and wrist models and provides a foundation for future work to build upon. Significance: This is the first open-source musculoskeletal model of the hand and wrist to be implemented during both functional kinetic and kinematic tasks. We provide a novel simulation framework to predict maximal grip and pinch force which can be used to evaluate how potential surgical and rehabilitation interventions influence these functional outcomes while requiring minimal experimental data.
Open AccessA Musculoskeletal Model of the Hand and Wrist Capable of Simulating Functional Tasks
Objective: The purpose of this work was to develop an open-source musculoskeletal model of the hand and wrist and to evaluate its performance during simulations of functional tasks. Methods: The musculoskeletal model was developed by adapting and expanding upon existing musculoskeletal models. An optimal control theory framework that combines forward-dynamics simulations with a simulated-annealing optimization was used to simulate maximum grip and pinch force. Active and passive hand opening were simulated to evaluate coordinated kinematic hand movements. Results: The model’s maximum grip force production matched experimental measures of grip force, force distribution amongst the digits, and displayed sensitivity to wrist flexion. Simulated lateral pinch strength fell within variability of in vivo palmar pinch strength data. Additionally, predicted activation for 7 of 8 muscles fell within variability of EMG data during palmar pinch. The active and passive hand opening simulations predicted reasonable activations and demonstrated passive motion mimicking tenodesis, respectively. Conclusion: This work advances simulation capabilities of hand and wrist models and provides a foundation for future work to build upon. Significance: This is the first open-source musculoskeletal model of the hand and wrist to be implemented during both functional kinetic and kinematic tasks. We provide a novel simulation framework to predict maximal grip and pinch force which can be used to evaluate how potential surgical and rehabilitation interventions influence these functional outcomes while requiring minimal experimental data.