AMAndrei Morozov

Andrei Morozov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrei Morozov has a total of 229 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Microfacet projected area-based correction for unified model of Geant4 for rough surfaces

    by A. Morozov

    A modification of the optical model for rough surfaces, implemented in Geant4 as a part of the unified model, is suggested. The modified model takes into account the variation of the interaction probability of the photon with the microfacet based on the relative orientation of the photon and the sampled microfacet's normal. The implementation is using a rejection algorithm and assumes the interaction probability to be proportional to the projection of the microfacet area on the plane perpendicular to the photon direction. A comparison of the results obtained with the original and the modified models, as well as obtained in direct Monte Carlo simulations are presented for several test surfaces constructed using a pattern of elementary geometrical shapes.

  • First PET Studies of a FLASH Proton Beam: Summary and Future Prospects

    by John P. Cesar, Firas Abouzahr, Paulo Crespo, Michael Gajda, Alex Kuo, Osama Mawlawi, Andrey Morozov, Aryan Ojha, Falk Poenisch, Marek Proga, et al.

    Objectives: Proton therapy, while highly effective and successful, still lacks a key feature: the ability to assess, in-vivo, the dose and end-point location of irradiations. Known as proton range verification, this capability can be realized by incorporating positron emission tomography (PET) systems in both conventional and emerging modalities, such as FLASH proton therapy. FLASH itself may revolutionize radiation oncology with its purported ability to better spare healthy tissues, but only if the underlying mechanisms can be understood. We summarize our work towards establishing in-beam PET modalities and elucidating the mystery of the FLASH effect. Materials: We've developed a PET scanner designed for live, in-beam imaging during therapeutic proton irradiations that can use short-lived positron emitting species (PES) activated by the beam to validate the range and dose of proton depositions. This scanner is made up of PET modules consisting of arrays of LYSO (lutetium-yttrium oxyorthosilicate) scintillating crystals coupled one-to-one to silicon photomultiplier (SiPM) arrays. These modules are readout by electronics based on the TOFPET2 ASIC platform from PETsys Electronics. Methods: Our collaboration with MD Anderson Cancer Center has given us opportunities to take real in-beam data using a non-clinical beamline capable of delivering FLASH proton irradiations into target phantoms made of polymethyl methacrylate (PMMA), high density polyethylene (HDPE), and water. Data collected both during and afterirradiations were used to perform novel analyses and to reconstruct images of PES activity due to the beam. Results: Exploratory studies, using a subset of our PET scanner, have demonstrated successful data acquisition during and after FLASH beam spills including quantitative imaging and dosimetry of activated phantoms. The full results, explored in this work, are highly promising and prove that in-beam PET can deliver on its goals. Upcoming experiments conducted using both FLASH and conventional beams will employ the full PET scanner and involve a rich experimental program with novel ideas for irradiation targets, beam characterization, and in-depth comparisons of the two irradiation modalities. Conclusions: This work demonstrates the unprecedented proof-of-principle for the capabilities of an in-beam PET scanner for imaging and dosimetry of both conventional and FLASH proton beams. These results open a new PET modality with proton beams which is particularly attractive for FLASH therapy but can serve effectively all proton irradiations, leading to improved treatment monitoring and image-guided therapy.


  • Open Access

    The first probe of a FLASH proton beam by PET

    by F Abouzahr, J P Cesar, P Crespo, M Gajda, Z Hu, K Klein, A S Kuo, S Majewski, O Mawlawi, A Morozov, et al.

    The recently observed FLASH effect related to high doses delivered with high rates has the potential to revolutionize radiation cancer therapy if promising results are confirmed and an underlying mechanism understood. Comprehensive measurements are essential to elucidate the phenomenon. We report the first-ever demonstration of measurements of successive in-spill and post-spill emissions of gammas arising from irradiations by a FLASH proton beam. A small positron emission tomography (PET) system was exposed in an ocular beam of the Proton Therapy Center at MD Anderson Cancer Center to view phantoms irradiated by 3.5 × 10 10 protons with a kinetic energy of 75.8 MeV delivered in 101.5 ms-long spills yielding a dose rate of 164 Gy s −1 . Most in-spill events were due to prompt gammas. Reconstructed post-spill tomographic events, recorded for up to 20 min, yielded quantitative imaging and dosimetric information. These findings open a new and novel modality for imaging and monitoring of FLASH proton therapy exploiting in-spill prompt gamma imaging followed by post-spill PET imaging.


  • Open Access

    The first PET glimpse of a proton FLASH beam

    by F Abouzahr, J P Cesar, P Crespo, M Gajda, Z Hu, W Kaye, K Klein, A S Kuo, S Majewski, O Mawlawi, et al.

    We demonstrate the first ever recorded positron-emission tomography (PET) imaging and dosimetry of a FLASH proton beam at the Proton Center of the MD Anderson Cancer Center. Two scintillating LYSO crystal arrays, read out by silicon photomultipliers, were configured with a partial field of view of a cylindrical poly-methyl methacrylate (PMMA) phantom irradiated by a FLASH proton beam. The proton beam had a kinetic energy of 75.8 MeV and an intensity of about 3.5 × 10 10 protons that were extracted over 101.5 ms-long spills. The radiation environment was characterized by cadmium–zinc–telluride and plastic scintillator counters. Preliminary results indicate that the PET technology used in our tests can efficiently record FLASH beam events. The instrument yielded informative and quantitative imaging and dosimetry of beam-activated isotopes in a PMMA phantom, as supported by Monte Carlo simulations. These studies open a new PET modality that can lead to improved imaging and monitoring of FLASH proton therapy.


  • Analysis of the Process of Electrical Steel Production

    by A. A. Zhemkov, A. O. Morozov, A. Yu. Em, O. A. Komolova, K. V. Grigorovich

    The technology of melting and secondary processing of electrical silicon steel and the changes in the content of oxide nonmetallic inclusions (NIs) in the metal at the stages of its secondary processing and casting is analyzed. Fractional gas analysis and scanning electron microscopy with electron-probe microanalysis are used to study samples of three heats taken at the stages of secondary processing and casting of electrical silicon steel. The total oxygen and nitrogen content and the amount and the main types of oxide NIs (silicates, aluminosilicates, spinels) in the samples are determined. The increase in the amount of spinel NIs in the metal samples is assumed to be related to the influence of deoxidizers, and the increase in the oxygen and nitrogen content in the samples taken in a steel degassing plant and in a tundish during heat I can indicate the influence of secondary oxidation at these processing stages. Commercial heat logs are analyzed and thermodynamic calculations are performed in order to determine the factors affecting the destruction intensity of the steel-teeming ladle lining and the increase in the content of NIs and carbon in the metal samples.

  • Statistical position reconstruction for RPC-based thermal neutron detectors

    by A. Morozov, L.M.S. Margato, V. Solovov, A. Blanco, J. Saraiva, T. Wilpert, K. Zeitelhack, K. Roemer, C. Höglund, L. Robinson, et al.

    Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a statistical approach. Using experimental data, we compare the performance of this method with that of the centroid reconstruction. Both methods result in a similar image linearity/uniformity and spatial resolution. However, the statistical method allows to improve the image quality at the detector periphery, offers more flexible event filtering and allows to develop automatic quality monitoring procedures for early detection of situations when a change in the detector operation conditions starts to affect reconstruction quality.

  • Open Access

    Statistical position reconstruction for RPC-based thermal neutron detectors

    by A. Morozov, L. M. S. Margato, V. Solovov, A. Blanco, J. Saraiva, T. Wilpert, K. Zeitelhack, K. Roemer, C. Höglund, L. Robinson, et al.

    Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a statistical approach. Using experimental data, we compare the performance of this method with that of the centroid reconstruction. Both methods result in a similar image linearity/uniformity and spatial resolution. However, the statistical method allows to improve the image quality at the detector periphery, offers more flexible event filtering and allows to develop automatic quality monitoring procedures for early detection of situations when a change in the detector operation conditions starts to affect reconstruction quality.