Kathryn A. Haass
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kathryn A. Haass has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Sridhar V. Basavaraju
Division of Healthcare Quality Promotion Centers for Disease Control and Prevention Atlanta Georgia
9 shared publicationsAlexandra A. Savinkina
Division of Healthcare Quality Promotion Centers for Disease Control and Prevention Atlanta Georgia
6 shared publicationsJames J. Berger
Office of HIV/AIDS and Infectious Disease Policy Office of the Assistant Secretary for Health, U.S. Department of Health and Human Services Washington District of Columbia
6 shared publicationsRichard A. Henry
Office of HIV/AIDS and Infectious Disease Policy Office of the Assistant Secretary for Health, U.S. Department of Health and Human Services Washington District of Columbia
5 shared publicationsMatthew J. Kuehnert
Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention (CDC) Atlanta Georgia
4 shared publicationsMisha L. Baker
Northrup Grumman Corporation, Atlanta, Georgia
4 shared publications
Latest Publications
- 3 June 2026
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 47 (7) , 1-4
Adoption of water management programs and risk assessment practices in hospitals—United States, 2017–2022
By 2022, 96% of U.S. acute care hospitals reported having water management programs (WMPs). Hospitals with more ICU beds and greater infection prevention expertise were more likely to conduct water infection control risk assessments (WICRAs). Smaller, rural hospitals showed lower adoption of both WMPs and WICRAs, suggesting resource-based disparities in WMP implementation.
- 3 June 2026
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 47 (7) , 1-4
Adoption of water management programs and risk assessment practices in hospitals—United States, 2017–2022
By 2022, 96% of U.S. acute care hospitals reported having water management programs (WMPs). Hospitals with more ICU beds and greater infection prevention expertise were more likely to conduct water infection control risk assessments (WICRAs). Smaller, rural hospitals showed lower adoption of both WMPs and WICRAs, suggesting resource-based disparities in WMP implementation.
- 10 September 2025
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
The Impact of a Nationwide Blood Culture Bottle Shortage in 2024 on Healthcare Facilities in the United States
Background: A shortage of BD BACTECTM blood culture bottles occurred in 2024. We describe the clinical impact of that shortage. Methods: We conducted a National Healthcare Safety Network (NHSN) questionnaire and retrospective cohort study using inpatient hospitalization data from the Premier Healthcare Database. In the retrospective cohort, facilities were categorized into BD BACTEC™ (n = 11) and non-BD BACTEC™ (n = 28) hospitals; non-shortage and shortage periods were considered from May 2023 to June 2024 and July to November 2024. We used a generalized linear model for the rate of blood cultures with an offset for patient days and adjusted for facility characteristics and other factors. Similarly, we modeled the rate of unique adult hospitalizations with a pathogen-positive blood culture per hospitalization. Results: Of 3196 facilities responding, 1456 (45.6%) indicated a use of BD BACTECTM to the NHSN questionnaire; of those, 1103 (75.8%) reported a shortage impact. In the retrospective cohort study, there was a 27.4% decrease in cultures at BD BACTEC™ hospitals during the shortage period (95% CI: −31.2% to −23.4%). BD BACTEC™ facilities had a median change in culturing rate of −33.3% (IQR: −47.0% to 2.0%) between the non-shortage and shortage periods. There was a 15.3% decrease in the rate of patients positive for a pathogen at affected facilities during the shortage (95% CI: −22.4% to −7.5%). Conclusions: BD BACTEC™ facilities experienced substantial and non-uniform decreases in blood culture rates. Impacted facilities had a decrease in the rate of observed bloodstream infections, which has implications for patient safety and surveillance.
- 10 September 2025
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
The Impact of a Nationwide Blood Culture Bottle Shortage in 2024 on Healthcare Facilities in the United States
Background: A shortage of BD BACTECTM blood culture bottles occurred in 2024. We describe the clinical impact of that shortage. Methods: We conducted a National Healthcare Safety Network (NHSN) questionnaire and retrospective cohort study using inpatient hospitalization data from the Premier Healthcare Database. In the retrospective cohort, facilities were categorized into BD BACTEC™ (n = 11) and non-BD BACTEC™ (n = 28) hospitals; non-shortage and shortage periods were considered from May 2023 to June 2024 and July to November 2024. We used a generalized linear model for the rate of blood cultures with an offset for patient days and adjusted for facility characteristics and other factors. Similarly, we modeled the rate of unique adult hospitalizations with a pathogen-positive blood culture per hospitalization. Results: Of 3196 facilities responding, 1456 (45.6%) indicated a use of BD BACTECTM to the NHSN questionnaire; of those, 1103 (75.8%) reported a shortage impact. In the retrospective cohort study, there was a 27.4% decrease in cultures at BD BACTEC™ hospitals during the shortage period (95% CI: −31.2% to −23.4%). BD BACTEC™ facilities had a median change in culturing rate of −33.3% (IQR: −47.0% to 2.0%) between the non-shortage and shortage periods. There was a 15.3% decrease in the rate of patients positive for a pathogen at affected facilities during the shortage (95% CI: −22.4% to −7.5%). Conclusions: BD BACTEC™ facilities experienced substantial and non-uniform decreases in blood culture rates. Impacted facilities had a decrease in the rate of observed bloodstream infections, which has implications for patient safety and surveillance.
- Open Access
- 24 June 2021
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 43 (10) , 1473-1476
Hospital capacities and shortages of healthcare resources among US hospitals during the coronavirus disease 2019 (COVID-19) pandemic, National Healthcare Safety Network (NHSN), March 27–July 14, 2020
During March 27–July 14, 2020, the Centers for Disease Control and Prevention’s National Healthcare Safety Network extended its surveillance to hospital capacities responding to COVID-19 pandemic. The data showed wide variations across hospitals in case burden, bed occupancies, ventilator usage, and healthcare personnel and supply status. These data were used to inform emergency responses.
- 24 June 2021
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 43 (10) , 1473-1476
Open AccessHospital capacities and shortages of healthcare resources among US hospitals during the coronavirus disease 2019 (COVID-19) pandemic, National Healthcare Safety Network (NHSN), March 27–July 14, 2020
During March 27–July 14, 2020, the Centers for Disease Control and Prevention’s National Healthcare Safety Network extended its surveillance to hospital capacities responding to COVID-19 pandemic. The data showed wide variations across hospitals in case burden, bed occupancies, ventilator usage, and healthcare personnel and supply status. These data were used to inform emergency responses.
- Open Access
- 5 March 2020
- Published by Wiley in Transfusion
- Vol. 60 (S2) , S17-S37
Supplemental findings of the 2017 National Blood Collection and Utilization Survey
INTRODUCTION: This report provides supplemental results from the 2017 National Blood Collection and Utilization Survey on characteristics of the donor population, autologous and directed donations and transfusions, platelets, plasma and granulocyte transfusions, pediatric transfusions, severe donor‐related adverse events, cost of blood units, hospitals policies and practices, and inventory, dosing, and supply.METHODS: Weighting and imputation were used to generate national estimates including number of donors, donations, donor deferrals, autologous and directed donations and transfusions, severe donor‐related adverse events, platelet and plasma collections and transfusions, number of cross‐match procedures, irradiation and leukoreduction, and pediatric transfusions.RESULTS: Between 2015 and 2017, successful donations decreased slightly by 2.1% with a 10.3% decrease in donations by persons aged 16‐18 years and a 14.4% increase in donations by donors aged >65 years. The median price paid for blood components by hospitals decreased from $211 to $207 for leukoreduced red blood cell units, from $523 to $517 for leukoreduced apheresis platelet units, and from $54 to $51 for fresh frozen plasma units. Plasma transfusions decreased 13.6%, but group AB plasma units transfused increased 24.7%.CONCLUSION: Between 2015 and 2017, blood donations declined slightly because of decreases in donations from younger donors, but the number of donations from older donors increased. The price hospitals pay for blood has continued to decrease. Plasma transfusions have decreased, but the proportion of plasma transfusions involving group AB plasma have increased.
- 5 March 2020
- Published by Wiley in Transfusion
- Vol. 60 (S2) , S17-S37
Open AccessSupplemental findings of the 2017 National Blood Collection and Utilization Survey
INTRODUCTION: This report provides supplemental results from the 2017 National Blood Collection and Utilization Survey on characteristics of the donor population, autologous and directed donations and transfusions, platelets, plasma and granulocyte transfusions, pediatric transfusions, severe donor‐related adverse events, cost of blood units, hospitals policies and practices, and inventory, dosing, and supply.METHODS: Weighting and imputation were used to generate national estimates including number of donors, donations, donor deferrals, autologous and directed donations and transfusions, severe donor‐related adverse events, platelet and plasma collections and transfusions, number of cross‐match procedures, irradiation and leukoreduction, and pediatric transfusions.RESULTS: Between 2015 and 2017, successful donations decreased slightly by 2.1% with a 10.3% decrease in donations by persons aged 16‐18 years and a 14.4% increase in donations by donors aged >65 years. The median price paid for blood components by hospitals decreased from $211 to $207 for leukoreduced red blood cell units, from $523 to $517 for leukoreduced apheresis platelet units, and from $54 to $51 for fresh frozen plasma units. Plasma transfusions decreased 13.6%, but group AB plasma units transfused increased 24.7%.CONCLUSION: Between 2015 and 2017, blood donations declined slightly because of decreases in donations from younger donors, but the number of donations from older donors increased. The price hospitals pay for blood has continued to decrease. Plasma transfusions have decreased, but the proportion of plasma transfusions involving group AB plasma have increased.
- Open Access
- 5 March 2020
- Published by Wiley in Transfusion
- Vol. 60 (S2) , S10-S16
Transfusion‐associated adverse events and implementation of blood safety measures ‐ findings from the 2017 National Blood Collection and Utilization Survey
BACKGROUND: Serious transfusion‐associated adverse events are rare in the United States. To enhance blood safety, various measures have been developed. With use of data from the 2017 National Blood Collection and Utilization Survey (NBCUS), we describe the rate of transfusion‐associated adverse events and the implementation of specific blood safety measures.STUDY DESIGN AND METHODS: Data from the 2017 NBCUS were used with comparison to already published estimates from 2015. Survey weighting and imputation were used to obtain national estimates of transfusion‐associated adverse events, and the number of units treated with pathogen reduction technology (PRT), screened for Babesia, and leukoreduced.RESULTS: The rate of transfusion‐associated adverse events requiring any diagnostic or therapeutic interventions was stable (275 reactions per 100,000 transfusions in 2015 and 282 reactions per 100,000 transfusions in 2017). In 2017 among US blood collection centers, 16 of 141 (11.3%) reported screening units for Babesia and 28 of 144 (19.4%) reported PRT implementation; 138 of 2279 (6.1%) hospitals reported transfusing PRT‐treated platelets. In 2017, 134 of 2336 (5.7%) hospitals reported performing secondary bacterial testing of platelets (50,922 culture‐based and 63,220 rapid immunoassay tests); in 2015, 71 of 1877 (3.8%) hospitals performed secondary testing (87,155 culture‐based and 21,779 rapid immunoassay tests). Nearly all whole blood/red blood cell units and platelet units were leukoreduced.CONCLUSIONS: Besides leukoreduction, implementation of most blood safety measures reported in this study remains low. Nationally, hospitals might be shifting from culture‐based secondary bacterial testing to rapid immunoassays.
- 5 March 2020
- Published by Wiley in Transfusion
- Vol. 60 (S2) , S10-S16
Open AccessTransfusion‐associated adverse events and implementation of blood safety measures ‐ findings from the 2017 National Blood Collection and Utilization Survey
BACKGROUND: Serious transfusion‐associated adverse events are rare in the United States. To enhance blood safety, various measures have been developed. With use of data from the 2017 National Blood Collection and Utilization Survey (NBCUS), we describe the rate of transfusion‐associated adverse events and the implementation of specific blood safety measures.STUDY DESIGN AND METHODS: Data from the 2017 NBCUS were used with comparison to already published estimates from 2015. Survey weighting and imputation were used to obtain national estimates of transfusion‐associated adverse events, and the number of units treated with pathogen reduction technology (PRT), screened for Babesia, and leukoreduced.RESULTS: The rate of transfusion‐associated adverse events requiring any diagnostic or therapeutic interventions was stable (275 reactions per 100,000 transfusions in 2015 and 282 reactions per 100,000 transfusions in 2017). In 2017 among US blood collection centers, 16 of 141 (11.3%) reported screening units for Babesia and 28 of 144 (19.4%) reported PRT implementation; 138 of 2279 (6.1%) hospitals reported transfusing PRT‐treated platelets. In 2017, 134 of 2336 (5.7%) hospitals reported performing secondary bacterial testing of platelets (50,922 culture‐based and 63,220 rapid immunoassay tests); in 2015, 71 of 1877 (3.8%) hospitals performed secondary testing (87,155 culture‐based and 21,779 rapid immunoassay tests). Nearly all whole blood/red blood cell units and platelet units were leukoreduced.CONCLUSIONS: Besides leukoreduction, implementation of most blood safety measures reported in this study remains low. Nationally, hospitals might be shifting from culture‐based secondary bacterial testing to rapid immunoassays.
- Open Access
- 21 February 2020
- Published by Wiley in Transfusion
- Vol. 60 (S2) , S1-S9
Slowing decline in blood collection and transfusion in the United States – 2017
INTRODUCTION: The National Blood Collection and Utilization Survey (NBCUS) has demonstrated declines in blood collection and transfusion in the United States since 2008, including declines of 11.6% in red blood cell (RBC) collections and 13.9% in RBC transfusions during 2013‐2015. This study described the 2017 NBCUS results.METHODS: The 2017 NBCUS was distributed to all US blood collection centers, all hospitals performing at least 1000 surgeries annually, and a 40% random sample of hospitals performing 100 to 999 surgeries annually. Weighting and imputation were used to generate national estimates for units of blood and components collected, deferred, distributed, transfused, and outdated.RESULTS: Response rates for the 2017 NBCUS were 88% for blood collection centers and 86% for transfusing hospitals. Compared with 2015, the number of RBC units collected during 2017 (12,211,000; 95% confidence interval [CI], 11,680,000‐12,742,000) declined by 3.0%, and transfused RBC units (10,654,000, 95% CI, 10,314,000‐10,995,000) declined by 6.1%. Distributed platelet (PLT) units (2,560,000; 95% CI, 2,391,000‐2,730,000 units) increased by 5.1%, and transfused PLT units (1,937,000, 95% CI, 1,794,000‐2,079,000) declined by 2.3%. Distributed plasma units (3,209,000; 95% CI, 2,879,000‐3,539,000) declined by 13.6%, and transfused plasma units (2,374,000; 95% CI, 2,262,000‐2,487,000) declined by 12.9%.CONCLUSION: The 2017 NBCUS suggests a continued but slowing decline in demand for RBCs. The decline in blood collection and use will likely continue. Despite decreasing demand and increasing manufacturing costs of blood products, the US blood industry has met the regular and emergent needs of the country.
- 21 February 2020
- Published by Wiley in Transfusion
- Vol. 60 (S2) , S1-S9
Open AccessSlowing decline in blood collection and transfusion in the United States – 2017
INTRODUCTION: The National Blood Collection and Utilization Survey (NBCUS) has demonstrated declines in blood collection and transfusion in the United States since 2008, including declines of 11.6% in red blood cell (RBC) collections and 13.9% in RBC transfusions during 2013‐2015. This study described the 2017 NBCUS results.METHODS: The 2017 NBCUS was distributed to all US blood collection centers, all hospitals performing at least 1000 surgeries annually, and a 40% random sample of hospitals performing 100 to 999 surgeries annually. Weighting and imputation were used to generate national estimates for units of blood and components collected, deferred, distributed, transfused, and outdated.RESULTS: Response rates for the 2017 NBCUS were 88% for blood collection centers and 86% for transfusing hospitals. Compared with 2015, the number of RBC units collected during 2017 (12,211,000; 95% confidence interval [CI], 11,680,000‐12,742,000) declined by 3.0%, and transfused RBC units (10,654,000, 95% CI, 10,314,000‐10,995,000) declined by 6.1%. Distributed platelet (PLT) units (2,560,000; 95% CI, 2,391,000‐2,730,000 units) increased by 5.1%, and transfused PLT units (1,937,000, 95% CI, 1,794,000‐2,079,000) declined by 2.3%. Distributed plasma units (3,209,000; 95% CI, 2,879,000‐3,539,000) declined by 13.6%, and transfused plasma units (2,374,000; 95% CI, 2,262,000‐2,487,000) declined by 12.9%.CONCLUSION: The 2017 NBCUS suggests a continued but slowing decline in demand for RBCs. The decline in blood collection and use will likely continue. Despite decreasing demand and increasing manufacturing costs of blood products, the US blood industry has met the regular and emergent needs of the country.
- 1 April 2019
- Published by Elsevier in Transfusion Medicine Reviews
- Vol. 33 (2) , 84-91
Transfusion-Transmitted Infections Reported to the National Healthcare Safety Network Hemovigilance Module
- 1 April 2019
- Published by Elsevier in Transfusion Medicine Reviews
- Vol. 33 (2) , 84-91
Transfusion-Transmitted Infections Reported to the National Healthcare Safety Network Hemovigilance Module
- Open Access
- 14 November 2018
- Published by Wiley in Transfusion
- Vol. 59 (2) , 524-533
Evaluation of the National Healthcare Safety Network Hemovigilance Module for transfusion‐related adverse reactions in the United States
INTRODUCTION: The National Healthcare Safety Network (NHSN) Hemovigilance Module (HM) collects data on the frequency, severity, and imputability of transfusion‐associated adverse events. These events contribute to significant morbidity and mortality among transfusion patients. We report results from the first systematic assessment of eight attributes of the HM.MATERIALS AND METHODS: Standard methods were used to assess the HM. Evaluation data included training materials, system modification history, and facility survey information. A concordance analysis was performed using data from the Baystate Medical Center's (Springfield, MA) electronic transfusion reporting system.RESULTS: In 2016, system representativeness remained low, with 6% (277 of 4690) of acute care facilities across 43 jurisdictions enrolled in the HM. In 2016, 48% (2147 of 4453) and 89% (3969 of 4,453) of adverse reactions were reported within 30 and 90 days of the reaction date, respectively, compared to 21% (109 of 511) and 56% (284 of 511) in 2010, demonstrating improved reporting timeliness. Data quality from most reactions was adequate, with 10% (45 of 442) misclassified transfusion‐associated circulatory overload reactions, and no incomplete transfusion‐transmitted infection data reported from 2010 to 2013. When compared to the Baystate system to assess concordance, 43% (24 of 56) of NHSN‐reported febrile reactions were captured in both systems (unweighted kappa value, 0.47; confidence interval, 0.33–0.61).CONCLUSION: Since the 2010 HM pilot, improvements have led to enhanced simplicity, timeliness, and strengthened data quality. The HM serves an important and unique role despite incomplete adoption nationwide. Facility efforts to track and prevent transfusion‐associated adverse events through systems like the NHSN HM are a key step toward improving transfusion safety in the United States.
- 14 November 2018
- Published by Wiley in Transfusion
- Vol. 59 (2) , 524-533
Open AccessEvaluation of the National Healthcare Safety Network Hemovigilance Module for transfusion‐related adverse reactions in the United States
INTRODUCTION: The National Healthcare Safety Network (NHSN) Hemovigilance Module (HM) collects data on the frequency, severity, and imputability of transfusion‐associated adverse events. These events contribute to significant morbidity and mortality among transfusion patients. We report results from the first systematic assessment of eight attributes of the HM.MATERIALS AND METHODS: Standard methods were used to assess the HM. Evaluation data included training materials, system modification history, and facility survey information. A concordance analysis was performed using data from the Baystate Medical Center's (Springfield, MA) electronic transfusion reporting system.RESULTS: In 2016, system representativeness remained low, with 6% (277 of 4690) of acute care facilities across 43 jurisdictions enrolled in the HM. In 2016, 48% (2147 of 4453) and 89% (3969 of 4,453) of adverse reactions were reported within 30 and 90 days of the reaction date, respectively, compared to 21% (109 of 511) and 56% (284 of 511) in 2010, demonstrating improved reporting timeliness. Data quality from most reactions was adequate, with 10% (45 of 442) misclassified transfusion‐associated circulatory overload reactions, and no incomplete transfusion‐transmitted infection data reported from 2010 to 2013. When compared to the Baystate system to assess concordance, 43% (24 of 56) of NHSN‐reported febrile reactions were captured in both systems (unweighted kappa value, 0.47; confidence interval, 0.33–0.61).CONCLUSION: Since the 2010 HM pilot, improvements have led to enhanced simplicity, timeliness, and strengthened data quality. The HM serves an important and unique role despite incomplete adoption nationwide. Facility efforts to track and prevent transfusion‐associated adverse events through systems like the NHSN HM are a key step toward improving transfusion safety in the United States.
- 7 June 2017
- Published by Wiley in Transfusion
- Vol. 57 (S2) , 1599-1624
Supplemental findings from the National Blood Collection and Utilization Surveys, 2013 and 2015
- 7 June 2017
- Published by Wiley in Transfusion
- Vol. 57 (S2) , 1599-1624
Supplemental findings from the National Blood Collection and Utilization Surveys, 2013 and 2015
- Top Cited PapersOpen Access
- 7 June 2017
- Published by Wiley in Transfusion
- Vol. 57 (S2) , 1588-1598
Continued decline in blood collection and transfusion in the United States–2015
BACKGROUND: In 2011 and 2013, the National Blood Collection and Utilization Survey (NBCUS) revealed declines in blood collection and transfusion in the United States. The objective of this study was to describe blood services in 2015.STUDY DESIGN AND METHODS: The 2015 NBCUS was distributed to all US blood collection centers, all hospitals performing at least 1000 surgeries annually, and a 40% random sample of hospitals performing 100 to 999 surgeries annually. Weighting and imputation were used to generate national estimates for units of blood and components collected, deferred, distributed, transfused, and outdated.RESULTS: Response rates for the 2015 NBCUS were 78.4% for blood collection centers and 73.9% for transfusing hospitals. In 2015, 12,591,000 units of red blood cells (RBCs) (95% confidence interval [CI], 11,985,000‐13,197,000 units of RBCs) were collected, and 11,349,000 (95% CI, 10,592,000‐11,747,000) were transfused, representing declines since 2013 of 11.6% and 13.9%, respectively. Total platelet units distributed (2,436,000; 95% CI, 2,230,000‐2,642,000) and transfused (1,983,000; 95% CI, 1,816,000 = 2,151,000) declined by 0.5% and 13.1%, respectively, since 2013. Plasma distributions (3,714,000; 95% CI, 3,306,000‐4,121,000) and transfusions (2,727,000; 95% CI, 2,594,000‐2,859,000) in 2015 declined since 2013. The median price paid per unit in 2015—$211 for leukocyte‐reduced RBCs, $524 for apheresis platelets, and $54 for fresh frozen plasma—was less for all components than in 2013.CONCLUSIONS: The 2015 NBCUS findings suggest that continued declines in demand for blood products resulted in fewer units collected and distributed Maintaining a blood inventory sufficient to meet routine and emergent demands will require further monitoring and understanding of these trends.
- 7 June 2017
- Published by Wiley in Transfusion
- Vol. 57 (S2) , 1588-1598
Top Cited PapersOpen AccessContinued decline in blood collection and transfusion in the United States–2015
BACKGROUND: In 2011 and 2013, the National Blood Collection and Utilization Survey (NBCUS) revealed declines in blood collection and transfusion in the United States. The objective of this study was to describe blood services in 2015.STUDY DESIGN AND METHODS: The 2015 NBCUS was distributed to all US blood collection centers, all hospitals performing at least 1000 surgeries annually, and a 40% random sample of hospitals performing 100 to 999 surgeries annually. Weighting and imputation were used to generate national estimates for units of blood and components collected, deferred, distributed, transfused, and outdated.RESULTS: Response rates for the 2015 NBCUS were 78.4% for blood collection centers and 73.9% for transfusing hospitals. In 2015, 12,591,000 units of red blood cells (RBCs) (95% confidence interval [CI], 11,985,000‐13,197,000 units of RBCs) were collected, and 11,349,000 (95% CI, 10,592,000‐11,747,000) were transfused, representing declines since 2013 of 11.6% and 13.9%, respectively. Total platelet units distributed (2,436,000; 95% CI, 2,230,000‐2,642,000) and transfused (1,983,000; 95% CI, 1,816,000 = 2,151,000) declined by 0.5% and 13.1%, respectively, since 2013. Plasma distributions (3,714,000; 95% CI, 3,306,000‐4,121,000) and transfusions (2,727,000; 95% CI, 2,594,000‐2,859,000) in 2015 declined since 2013. The median price paid per unit in 2015—$211 for leukocyte‐reduced RBCs, $524 for apheresis platelets, and $54 for fresh frozen plasma—was less for all components than in 2013.CONCLUSIONS: The 2015 NBCUS findings suggest that continued declines in demand for blood products resulted in fewer units collected and distributed Maintaining a blood inventory sufficient to meet routine and emergent demands will require further monitoring and understanding of these trends.