Julio Cesar Guerra Justino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Julio Cesar Guerra Justino has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Braz J. Cardoso Filho
3 shared publicationsBraz de J. Cardoso Filho
Department of Electrical Eng.- UFMG
3 shared publicationsGiovani G. Rodrigues
2 shared publicationsThiago M. Parreiras
Graduate Program in Electrical Engineering - Federal University of Minas Gerais, Belo Horizonte, Brazil
2 shared publications- Alex Sander Amável Luiz
Department of Electrical Engineering, Centro Federal de Educao Tecnolgica de Minas Gerais, Belo Horizonte, Brazil
1 shared publication Alex-Sander A. Luiz
Department Belo Horizonte, CEFET/MG Electrical Engineering, Brazil
1 shared publication
Latest Publications
- 3 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 2087-2096
A Simple Torque Estimator for In-Service Efficiency Determination of Inverter-Fed Induction Motors
- 3 January 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 2087-2096
A Simple Torque Estimator for In-Service Efficiency Determination of Inverter-Fed Induction Motors
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
A Simple Torque Estimator for In-Service Efficiency Determination of Inverter Fed Induction Motors
This work deals with air-gap torque estimation in inverter fed induction motors. Torque estimation is one of the main functions needed to successful implementation of energy consumption and efficiency estimation methods used today. Those methods are essential to monitoring electric motors and processes in mining and metals industries. Given that some of the drives have voltage and current sensors already installed in them for condition monitoring, it is very attractive to use measurement data available to perform torque and efficiency estimation. The goal is to implement these functions without process interruption and/or requiring minimum changes on the drive configuration. Most of the torque estimation algorithms require two or three voltage and current measurement to be implemented. Aiming to reduce the number of sensors and obtain a lower cost setup, a solution requiring data acquisition of the current and voltage of only one phase suited to be used in algorithms of efficiency estimation of in-service induction motors was presented in a previous paper. It was investigated in it the performance of the method when applied to induction motors directly connected to the mains. In this paper, the performance of the method is additionally investigated, but, at this time, the induction motor is supplied by means of a PWM frequency inverter. The effects of unbalance in voltage supply are described and analyzed. Simulation and experimental results are used to check the validity and performance of the proposed technique.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
A Simple Torque Estimator for In-Service Efficiency Determination of Inverter Fed Induction Motors
This work deals with air-gap torque estimation in inverter fed induction motors. Torque estimation is one of the main functions needed to successful implementation of energy consumption and efficiency estimation methods used today. Those methods are essential to monitoring electric motors and processes in mining and metals industries. Given that some of the drives have voltage and current sensors already installed in them for condition monitoring, it is very attractive to use measurement data available to perform torque and efficiency estimation. The goal is to implement these functions without process interruption and/or requiring minimum changes on the drive configuration. Most of the torque estimation algorithms require two or three voltage and current measurement to be implemented. Aiming to reduce the number of sensors and obtain a lower cost setup, a solution requiring data acquisition of the current and voltage of only one phase suited to be used in algorithms of efficiency estimation of in-service induction motors was presented in a previous paper. It was investigated in it the performance of the method when applied to induction motors directly connected to the mains. In this paper, the performance of the method is additionally investigated, but, at this time, the induction motor is supplied by means of a PWM frequency inverter. The effects of unbalance in voltage supply are described and analyzed. Simulation and experimental results are used to check the validity and performance of the proposed technique.
- 23 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (3) , 2737-2746
True Unit Power Factor Active Front End for High-Capacity Belt-Conveyor Systems
Belt conveyors in mining industry constitute an efficient and economical way for minerals and heavy-load transportation from mines to their destination. The ongoing desire to further extend the length, speed, and capacity of the conveyors has led to the increasing size of the conveyor-drive systems. More and more frequently, high-capacity belt conveyors are efficiently driven employing medium-voltage power converters connected with large induction motors. Power converters in the megawatt (MW) range are often used, increasing the power-quality issues in the grid system. This work proposes a new true unit power factor active front end for regenerative multimotor conveyor-drive systems. The proposed solution eliminates all the current harmonics in the range considered by the international standards without using sinusoidal filters. Three-winding conventional transformer and well-established medium-voltage power converters are considered to ensure the robustness and simplicity requirements.
- 23 February 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (3) , 2737-2746
True Unit Power Factor Active Front End for High-Capacity Belt-Conveyor Systems
Belt conveyors in mining industry constitute an efficient and economical way for minerals and heavy-load transportation from mines to their destination. The ongoing desire to further extend the length, speed, and capacity of the conveyors has led to the increasing size of the conveyor-drive systems. More and more frequently, high-capacity belt conveyors are efficiently driven employing medium-voltage power converters connected with large induction motors. Power converters in the megawatt (MW) range are often used, increasing the power-quality issues in the grid system. This work proposes a new true unit power factor active front end for regenerative multimotor conveyor-drive systems. The proposed solution eliminates all the current harmonics in the range considered by the international standards without using sinusoidal filters. Three-winding conventional transformer and well-established medium-voltage power converters are considered to ensure the robustness and simplicity requirements.
- 27 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (00939994) , 1
Hundreds kW Charging Stations for e-Buses Operating Under Regular Ultra-Fast Charging
A natural evolution in public transportation vehicles is the development toward electric-driven buses (e-buses). Battery weight and volume is still a challenge in the electrification of general-purpose vehicles, but the urban bus systems have some characteristics that can be explored to address such issues. In particular, the predefined routes and stops create opportunities for reduction of onboard storage capacity through regular ultra-fast charging (R-UFC), based on chargers installed next to the boarding stations. This paper proposes a power architecture for UFC stations using the true unity power factor (TUPF) rectifier as the charger front end and interleaved dc-dc converters as the charger output. Both technologies contribute significantly to the reduction of filter components and assure high power quality standards. The proposed TUPF rectifier eliminates all harmonic orders up to the 50th, operates with low switching frequency, and does not require sinusoidal filters. The UFC stations are presented, and their investigation is carried on using computer simulations of a 400-kW application. The proposed concept is verified experimentally using a laboratory test setup.
- 27 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (00939994) , 1
Hundreds kW Charging Stations for e-Buses Operating Under Regular Ultra-Fast Charging
A natural evolution in public transportation vehicles is the development toward electric-driven buses (e-buses). Battery weight and volume is still a challenge in the electrification of general-purpose vehicles, but the urban bus systems have some characteristics that can be explored to address such issues. In particular, the predefined routes and stops create opportunities for reduction of onboard storage capacity through regular ultra-fast charging (R-UFC), based on chargers installed next to the boarding stations. This paper proposes a power architecture for UFC stations using the true unity power factor (TUPF) rectifier as the charger front end and interleaved dc-dc converters as the charger output. Both technologies contribute significantly to the reduction of filter components and assure high power quality standards. The proposed TUPF rectifier eliminates all harmonic orders up to the 50th, operates with low switching frequency, and does not require sinusoidal filters. The UFC stations are presented, and their investigation is carried on using computer simulations of a 400-kW application. The proposed concept is verified experimentally using a laboratory test setup.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506078,p. 2557-2565
The True Unity Power Factor converter — A practical filterless solution for sinusoidal currents
High power conversion entails the necessity of converters interfacing with the grid which have both low losses and low harmonic content. For this purpose several topologies have been proposed, but, due to the restriction imposed on the switching frequency, these topologies often make use of complex multi winding transformers or large sinusoidal filters. These features increase cost, losses and reduce reliability of the converters. This paper proposes a new solution called True Unity Power Factor (TUPF) converter, which makes use of a well selected PWM pattern, a simple three winding transformer and two or three level active rectifier topologies. As the name implies, this converter is capable of delivering a true unity power factor conversion and accomplish these task keeping a low enough switching frequency without using any capacitive filter element. This paper shows the mains elements of the TUPF concept, some applicable regenerative or non-regenerative topologies, simulation and experimental results.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21506078,p. 2557-2565
The True Unity Power Factor converter — A practical filterless solution for sinusoidal currents
High power conversion entails the necessity of converters interfacing with the grid which have both low losses and low harmonic content. For this purpose several topologies have been proposed, but, due to the restriction imposed on the switching frequency, these topologies often make use of complex multi winding transformers or large sinusoidal filters. These features increase cost, losses and reduce reliability of the converters. This paper proposes a new solution called True Unity Power Factor (TUPF) converter, which makes use of a well selected PWM pattern, a simple three winding transformer and two or three level active rectifier topologies. As the name implies, this converter is capable of delivering a true unity power factor conversion and accomplish these task keeping a low enough switching frequency without using any capacitive filter element. This paper shows the mains elements of the TUPF concept, some applicable regenerative or non-regenerative topologies, simulation and experimental results.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 3101-3107
Aspects of the operation of regular ultra fast charging e-Bus in high grade BRT routes
Nowadays the public transportation is submitted to severe restrictions on emissions and there are considerable incentives for low-emission technologies. In this scenario, e-bus stands out as a viable alternative. Although the weight and volume of batteries has been the an issue for electric vehicles, the urban bus has some characteristics such as predefined routes and stops that contribute to optimized onboard storage and regular recharging. This paper shows the analysis of a system based on regular ultra-fast charging at the bus stops for applications on a Bus Rapid Transit using battery e-bus and utracapacitor e-bus. Also, it is proposed the using of batteies as secondary source in the utracapacitor e-bus for operating on more demanded consumptions cycles. This allows to reduce the storage pack sizing. Based on computer simulation and e-bus technology considerations, an actual high grade BRT route in Brazil is analyzed.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 3101-3107
Aspects of the operation of regular ultra fast charging e-Bus in high grade BRT routes
Nowadays the public transportation is submitted to severe restrictions on emissions and there are considerable incentives for low-emission technologies. In this scenario, e-bus stands out as a viable alternative. Although the weight and volume of batteries has been the an issue for electric vehicles, the urban bus has some characteristics such as predefined routes and stops that contribute to optimized onboard storage and regular recharging. This paper shows the analysis of a system based on regular ultra-fast charging at the bus stops for applications on a Bus Rapid Transit using battery e-bus and utracapacitor e-bus. Also, it is proposed the using of batteies as secondary source in the utracapacitor e-bus for operating on more demanded consumptions cycles. This allows to reduce the storage pack sizing. Based on computer simulation and e-bus technology considerations, an actual high grade BRT route in Brazil is analyzed.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 2731-2737
Design and implementation of a low-cost robotic load carrier
Many professional or daily activities demand load displacement by human arms or by human powered vehicles. Those activities may cause muscle-skeleton diseases even in load carrying professionals as in people carrying their daily objects. In the field of robotics, the research developments to help people at those activities are made through human-robot cooperation systems actuated by servo drives. Due to the cost of those drives, many people are not able to acquire the robots and so they are prohibited from getting the associated health benefits. To promote robot-aided solutions, this paper presents the design and implementation of a load carrier human-robot cooperation system, which is built through an electrical load cart and driven by frequency inverter and induction motor. The robot controller is implemented by a force regulation structure which allows the conductor to set the mechanical trajectories through the multiplication of the force applied by his/her arms. Since the arms have a higher positioning bandwidth than the conductor's legs, the controller dynamic response is tuned with human leg dynamics in mind, so as to increase the operational safety. The paper presents details of mounting, firmware design and measurements to show the robot performance.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 2731-2737
Design and implementation of a low-cost robotic load carrier
Many professional or daily activities demand load displacement by human arms or by human powered vehicles. Those activities may cause muscle-skeleton diseases even in load carrying professionals as in people carrying their daily objects. In the field of robotics, the research developments to help people at those activities are made through human-robot cooperation systems actuated by servo drives. Due to the cost of those drives, many people are not able to acquire the robots and so they are prohibited from getting the associated health benefits. To promote robot-aided solutions, this paper presents the design and implementation of a load carrier human-robot cooperation system, which is built through an electrical load cart and driven by frequency inverter and induction motor. The robot controller is implemented by a force regulation structure which allows the conductor to set the mechanical trajectories through the multiplication of the force applied by his/her arms. Since the arms have a higher positioning bandwidth than the conductor's legs, the controller dynamic response is tuned with human leg dynamics in mind, so as to increase the operational safety. The paper presents details of mounting, firmware design and measurements to show the robot performance.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 892-899
Hundreds kW charging stations for e-buses operating under regular ultra-fast charging
A natural evolution for public transportation vehicles is to develop towards the electric driven buses (e-buses). Batteries weight and volume is still an issue for passenger electric cars. However, the urban bus has interesting characteristics as predefined routes and stops which allow an optimized onboard storage capacity and strategies of Regular Ultra Fast Charging (R-UFC). This way, some hundreds kW charging stations (UFC-Station) may be installed next to the bus boarding stations for providing the R-UFC in e-bus. This paper proposes a power architecture for UFC-stations using the new True Unit Power Factor (TUPF) Rectifier as a charger front-end and interleaved dc-dc converters as charger output. Both technologies contribute significantly to the reduction of filter components and assure high power quality standards. The proposed TUPF rectifier eliminates all harmonic order up to 50th, operates with low switching frequency and does not use sinusoidal filter. The UFC-stations are explained and evaluated based on computer simulations of a 400 kW application.
- 1 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 892-899
Hundreds kW charging stations for e-buses operating under regular ultra-fast charging
A natural evolution for public transportation vehicles is to develop towards the electric driven buses (e-buses). Batteries weight and volume is still an issue for passenger electric cars. However, the urban bus has interesting characteristics as predefined routes and stops which allow an optimized onboard storage capacity and strategies of Regular Ultra Fast Charging (R-UFC). This way, some hundreds kW charging stations (UFC-Station) may be installed next to the bus boarding stations for providing the R-UFC in e-bus. This paper proposes a power architecture for UFC-stations using the new True Unit Power Factor (TUPF) Rectifier as a charger front-end and interleaved dc-dc converters as charger output. Both technologies contribute significantly to the reduction of filter components and assure high power quality standards. The proposed TUPF rectifier eliminates all harmonic order up to 50th, operates with low switching frequency and does not use sinusoidal filter. The UFC-stations are explained and evaluated based on computer simulations of a 400 kW application.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Avaliação de um sistema de recuperação de energia baseado em armazenadores de energia como alternativa ao uso dos retificadores PWM
This paper discusses the main features of two regenerative braking systems, using PWM rectifiers and using an energy storage system connected on the DC bus. Will be presented the features of these systems and simulation results.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Avaliação de um sistema de recuperação de energia baseado em armazenadores de energia como alternativa ao uso dos retificadores PWM
This paper discusses the main features of two regenerative braking systems, using PWM rectifiers and using an energy storage system connected on the DC bus. Will be presented the features of these systems and simulation results.