Hatice Eser Ökten
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hatice Eser Ökten has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Aysegul Yagmur Goren
Clean Energy Research Laboratory, Faculty of Engineering and Applied Science Ontario Tech University Ontario Canada
5 shared publications - Huseyin Kurtulus Ozcan
Department of Environmental Engineering, Engineering Faculty, Istanbul University-Cerrahpasa, Avcilar, Istanbul, Turkey
5 shared publications Goksel Demir
4 shared publications- Asli Coban
Trinity College Dublin, The University of Dublin, School of Chemistry, CRANN & AMBER, Dublin, Ireland
3 shared publications - Daniel R. Noguera
Great Lakes Bioenergy Research Center, University of Wisconsin-Madison
3 shared publications - Ummugulsum Alyuz3 shared publications
Latest Publications
- 12 September 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 10 (12) , 3279-3289
Concurrent boron removal from reverse osmosis concentrate and energy production using a microbial desalination cell-Donnan dialysis hybrid system
The removal of boron from aqueous solutions offers an important opportunity to improve the management of sustainable resources. In this regard, microbial desalination cells (MDCs) are a promising bioelectrochemical approach for effective water treatment, but the integrated MDC-Donnan Dialysis (DD) process for boron removal from reverse osmosis (RO) concentrated effluents has not been investigated before. Integration of the DD process with MDC is investigated in this paper for the first time to enhance the efficiency of the process by providing pre-treatment and natural pH manipulation. Therefore, the MDC process was evaluated for boron removal from boron-containing synthetic solution, geothermal water, and RO-concentrated effluent with the help of the DD system. The highest boron removal performance, with an efficiency of 72.1% in the desalination chamber and 74.8% in the DD-feed chamber, was obtained for boron-containing synthetic solution, while the COD removal efficiency was almost 90% in all water resources. However, the maximum power density was 4818 mW m−2 with a closed circuit voltage of 1317 mV for RO concentrated water treatment due to its high ionic strength. Moreover, the most crucial output of this study is that the pH value of the system did not need to be adjusted continuously to convert the uncharged boric acid into the borate ion in the charged form owing to better manipulation of the pH by the DD system. Overall, the integrated MDC-DD system provided promising results, presenting effective boron-containing water desalination, yeast wastewater treatment, and enhanced energy production.
- 12 September 2024
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Water Research & Technology
- Vol. 10 (12) , 3279-3289
Concurrent boron removal from reverse osmosis concentrate and energy production using a microbial desalination cell-Donnan dialysis hybrid system
The removal of boron from aqueous solutions offers an important opportunity to improve the management of sustainable resources. In this regard, microbial desalination cells (MDCs) are a promising bioelectrochemical approach for effective water treatment, but the integrated MDC-Donnan Dialysis (DD) process for boron removal from reverse osmosis (RO) concentrated effluents has not been investigated before. Integration of the DD process with MDC is investigated in this paper for the first time to enhance the efficiency of the process by providing pre-treatment and natural pH manipulation. Therefore, the MDC process was evaluated for boron removal from boron-containing synthetic solution, geothermal water, and RO-concentrated effluent with the help of the DD system. The highest boron removal performance, with an efficiency of 72.1% in the desalination chamber and 74.8% in the DD-feed chamber, was obtained for boron-containing synthetic solution, while the COD removal efficiency was almost 90% in all water resources. However, the maximum power density was 4818 mW m−2 with a closed circuit voltage of 1317 mV for RO concentrated water treatment due to its high ionic strength. Moreover, the most crucial output of this study is that the pH value of the system did not need to be adjusted continuously to convert the uncharged boric acid into the borate ion in the charged form owing to better manipulation of the pH by the DD system. Overall, the integrated MDC-DD system provided promising results, presenting effective boron-containing water desalination, yeast wastewater treatment, and enhanced energy production.
- 18 October 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 907, 167778
Microbial desalination cell treated spent geothermal brine as a nutrient medium in hydroponic lettuce cultivation: Health risk assessment
- 18 October 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 907, 167778
Microbial desalination cell treated spent geothermal brine as a nutrient medium in hydroponic lettuce cultivation: Health risk assessment
- Open Access
- 1 December 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (49) , 45422-45431
Novel Hybrid Adsorption-Electrodialysis (AdED) System for Removal of Boron from Geothermal Brine
A novel hybrid adsorption-electrodialysis (AdED) system to remove environmentally harmful boron from geothermal brine was designed and effective operating parameters such as pH, voltage, and flow rate were studied. A cellulose-based adsorbent was synthesized from glycidyl methacrylate (GMA) grafted cellulose and modified with a boron selective n-methyl-d-glucamine (NMDG) group and characterized with SEM-EDX, FT-IR, and TGA analyses. Batch adsorption studies revealed that cellulose-based adsorbent showed a remarkable boron removal capacity (19.29 mg/g), a wide stable operating pH range (2-10), and an adsorption process that followed the Freundlich isotherm (R 2 = 0.95) and pseudo-second-order kinetics (R 2 = 0.99). In the hybrid AdED system, the optimum operating parameters for boron removal were found to be a pH of 10, a voltage of 10 V, a flow rate of 100 mL/min, and an adsorbent dosage of 4 g/L. The presence of the adsorbent in the hybrid system increased boron removal from real geothermal brine (containing 199 ppm boron) from 7.2% to 73.3%. The results indicate that the designed AdED system performs better than bare electrodialysis for boron removal from ion-rich real geothermal brine while utilizing environmentally friendly cellulose-based adsorbent.
- 1 December 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (49) , 45422-45431
Open AccessNovel Hybrid Adsorption-Electrodialysis (AdED) System for Removal of Boron from Geothermal Brine
A novel hybrid adsorption-electrodialysis (AdED) system to remove environmentally harmful boron from geothermal brine was designed and effective operating parameters such as pH, voltage, and flow rate were studied. A cellulose-based adsorbent was synthesized from glycidyl methacrylate (GMA) grafted cellulose and modified with a boron selective n-methyl-d-glucamine (NMDG) group and characterized with SEM-EDX, FT-IR, and TGA analyses. Batch adsorption studies revealed that cellulose-based adsorbent showed a remarkable boron removal capacity (19.29 mg/g), a wide stable operating pH range (2-10), and an adsorption process that followed the Freundlich isotherm (R 2 = 0.95) and pseudo-second-order kinetics (R 2 = 0.99). In the hybrid AdED system, the optimum operating parameters for boron removal were found to be a pH of 10, a voltage of 10 V, a flow rate of 100 mL/min, and an adsorbent dosage of 4 g/L. The presence of the adsorbent in the hybrid system increased boron removal from real geothermal brine (containing 199 ppm boron) from 7.2% to 73.3%. The results indicate that the designed AdED system performs better than bare electrodialysis for boron removal from ion-rich real geothermal brine while utilizing environmentally friendly cellulose-based adsorbent.
- Open Access
- 2 September 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (36) , 32640-32652
Electrochemical Degradation of Methylene Blue by a Flexible Graphite Electrode: Techno-Economic Evaluation
In this study, electrochemical removal of methylene blue (MB) from water using commercially available and low-cost flexible graphite was investigated. The operating conditions such as initial dye concentration, initial solution pH, electrolyte dose, electrical potential, and operating time were investigated. The Box-Behnken experimental design (BBD) was used to optimize the system's performance with the minimum number of tests possible, as well as to examine the independent variables' impact on the removal efficiency, energy consumption, operating cost, and effluent MB concentration. The electrical potential and electrolyte dosage both improved the MB removal efficiency, since increased electrical potential facilitated production of oxidizing agents and increase in electrolyte dosage translated into an increase in electrical current transfer. As expected, MB removal efficiency increased with longer operational periods. The combined effects of operating time-electrical potential and electrical potential-electrolyte concentration improved the MB removal efficiency. The maximum removal efficiency (99.9%) and lowest operating cost (0.012 $/m3) were obtained for initial pH 4, initial MB concentration 26.5 mg/L, electrolyte concentration 0.6 g/L, electrical potential 3 V, and operating time 30 min. The reaction kinetics was maximum for pH 5, and as the pH increased the reaction rates decreased. Consequent techno-economic assessment showed that electrochemical removal of MB using low-cost and versatile flexible graphite had a competitive advantage.
- 2 September 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (36) , 32640-32652
Open AccessElectrochemical Degradation of Methylene Blue by a Flexible Graphite Electrode: Techno-Economic Evaluation
In this study, electrochemical removal of methylene blue (MB) from water using commercially available and low-cost flexible graphite was investigated. The operating conditions such as initial dye concentration, initial solution pH, electrolyte dose, electrical potential, and operating time were investigated. The Box-Behnken experimental design (BBD) was used to optimize the system's performance with the minimum number of tests possible, as well as to examine the independent variables' impact on the removal efficiency, energy consumption, operating cost, and effluent MB concentration. The electrical potential and electrolyte dosage both improved the MB removal efficiency, since increased electrical potential facilitated production of oxidizing agents and increase in electrolyte dosage translated into an increase in electrical current transfer. As expected, MB removal efficiency increased with longer operational periods. The combined effects of operating time-electrical potential and electrical potential-electrolyte concentration improved the MB removal efficiency. The maximum removal efficiency (99.9%) and lowest operating cost (0.012 $/m3) were obtained for initial pH 4, initial MB concentration 26.5 mg/L, electrolyte concentration 0.6 g/L, electrical potential 3 V, and operating time 30 min. The reaction kinetics was maximum for pH 5, and as the pH increased the reaction rates decreased. Consequent techno-economic assessment showed that electrochemical removal of MB using low-cost and versatile flexible graphite had a competitive advantage.
- Open Access
- 9 August 2022
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 167
Boron in geothermal energy: Sources, environmental impacts, and management in geothermal fluid
- 9 August 2022
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 167
Open AccessBoron in geothermal energy: Sources, environmental impacts, and management in geothermal fluid
- Open Access
Desalination and Detoxification of Textile Wastewater by Novel Photocatalytic Electrolysis Membrane Reactor for Ecosafe Hydroponic Farming
In this study, a novel photoelectrocatalytic membrane (PECM) reactor was tested as an option for the desalination, disinfection, and detoxification of biologically treated textile wastewater (BTTWW), with the aim to reuse it in hydroponic farming. The anionic ion exchange (IEX) process was used before PECM treatment to remove toxic residual dyes. The toxicity evaluation for every effluent was carried out using the Vibrio fischeri, Microtox® test protocol. The disinfection effect of the PECM reactor was studied against E. coli. After PECM treatment, the 78.7% toxicity level of the BTTWW was reduced to 14.6%. However, photocatalytic desalination during treatment was found to be slow (2.5 mg L−1 min−1 at 1 V potential). The reactor demonstrated approximately 52% COD and 63% TOC removal efficiency. The effects of wastewater reuse on hydroponic production were comparatively investigated by following the growth of the lettuce plant. A detrimental effect was observed on the lettuce plant by the reuse of BTTWW, while no negative impact was reported using the PECM treated textile wastewater. In addition, all macro/micronutrient elements in the PECM treated textile wastewater were recovered by hydroponic farming, and the PECM treatment may be an eco-safe wastewater reuse method for crop irrigation.
Open AccessDesalination and Detoxification of Textile Wastewater by Novel Photocatalytic Electrolysis Membrane Reactor for Ecosafe Hydroponic Farming
In this study, a novel photoelectrocatalytic membrane (PECM) reactor was tested as an option for the desalination, disinfection, and detoxification of biologically treated textile wastewater (BTTWW), with the aim to reuse it in hydroponic farming. The anionic ion exchange (IEX) process was used before PECM treatment to remove toxic residual dyes. The toxicity evaluation for every effluent was carried out using the Vibrio fischeri, Microtox® test protocol. The disinfection effect of the PECM reactor was studied against E. coli. After PECM treatment, the 78.7% toxicity level of the BTTWW was reduced to 14.6%. However, photocatalytic desalination during treatment was found to be slow (2.5 mg L−1 min−1 at 1 V potential). The reactor demonstrated approximately 52% COD and 63% TOC removal efficiency. The effects of wastewater reuse on hydroponic production were comparatively investigated by following the growth of the lettuce plant. A detrimental effect was observed on the lettuce plant by the reuse of BTTWW, while no negative impact was reported using the PECM treated textile wastewater. In addition, all macro/micronutrient elements in the PECM treated textile wastewater were recovered by hydroponic farming, and the PECM treatment may be an eco-safe wastewater reuse method for crop irrigation.
- 1 December 2021
- Published by Elsevier in Chemosphere
- Vol. 285, 131370
Energy production from treatment of industrial wastewater and boron removal in aqueous solutions using microbial desalination cell
- 1 December 2021
- Published by Elsevier in Chemosphere
- Vol. 285, 131370
Energy production from treatment of industrial wastewater and boron removal in aqueous solutions using microbial desalination cell
- 30 September 2021
- Published by Echo Academic Publishing in Environmental Research and Technology
- Vol. 4 (3) , 190-198
An experimental study on release mechanism of iron and manganese from sediments to the water column in reservoirs
Iron and manganese accumulation in drinking water reservoirs is a challenging issue and should be controlled to prevent their adverse effects on human health. Accumulation of these elements not only clogs pipeline systems but also causes stains on fixtures and laundry. Also, high concentrations of iron and manganese may lead to various health problems when ingested. This study focuses on the release mechanism of iron and manganese from sediments to the water column in reservoirs and investigates methods to prevent this release. Effects of hypoxia, hypolimnetic aeration, alkalinity of water, and thermal stratification on iron and manganese concentrations were investigated through laboratory experiments. Experiments done simulating the water column showed that hypoxia caused more dissolution of ferrous iron when compared with that of manganese. Accordingly, aeration of the water column in hypoxic conditions lead to a significant decrease in ferrous iron concentrations (in our case reaching zero). However, manganese and total iron levels were not affected by the aeration of the water column. Alkalinity level of the water column was observed to have a great effect on the solubility of iron and manganese. Concentrations of total Fe and total Mn measured for acidic (pH=5) conditions were considerably greater than concentrations measured at neutral conditions. As for alkaline (pH=11) conditions, the opposite was observed with measured concentrations of total Fe and total Mn being lower than the ones measured for neutral conditions. Thermal stratification had an enhancing effect on the solubility of both iron and manganese ions. While aeration of the stratified water column slightly decreased the concentrations of Total Fe and Mn, it had a greater impact on decreasing Fe2+ concentrations.
- 30 September 2021
- Published by Echo Academic Publishing in Environmental Research and Technology
- Vol. 4 (3) , 190-198
An experimental study on release mechanism of iron and manganese from sediments to the water column in reservoirs
Iron and manganese accumulation in drinking water reservoirs is a challenging issue and should be controlled to prevent their adverse effects on human health. Accumulation of these elements not only clogs pipeline systems but also causes stains on fixtures and laundry. Also, high concentrations of iron and manganese may lead to various health problems when ingested. This study focuses on the release mechanism of iron and manganese from sediments to the water column in reservoirs and investigates methods to prevent this release. Effects of hypoxia, hypolimnetic aeration, alkalinity of water, and thermal stratification on iron and manganese concentrations were investigated through laboratory experiments. Experiments done simulating the water column showed that hypoxia caused more dissolution of ferrous iron when compared with that of manganese. Accordingly, aeration of the water column in hypoxic conditions lead to a significant decrease in ferrous iron concentrations (in our case reaching zero). However, manganese and total iron levels were not affected by the aeration of the water column. Alkalinity level of the water column was observed to have a great effect on the solubility of iron and manganese. Concentrations of total Fe and total Mn measured for acidic (pH=5) conditions were considerably greater than concentrations measured at neutral conditions. As for alkaline (pH=11) conditions, the opposite was observed with measured concentrations of total Fe and total Mn being lower than the ones measured for neutral conditions. Thermal stratification had an enhancing effect on the solubility of both iron and manganese ions. While aeration of the stratified water column slightly decreased the concentrations of Total Fe and Mn, it had a greater impact on decreasing Fe2+ concentrations.
- 1 September 2021
- Published by Marmara University in International Journal of Advances in Engineering and Pure Sciences
- Vol. 33 (3) , 337-346
Noktasal Kaynaklar İçin Ulusal Hava Kirliliği Emisyon Faktörleri ve Envanterinin Belirlenmesi: Metal Sektörü İçin Örnek Bir Çalışma
Günümüzde hava kalitesinin korunması ve izlenmesi için yürütülen çalışmalar ve yasal uygulamalar, çevre bilincinin yerleşmesi ile daha da önemli hale gelmiştir. Gelişen teknolojiler, alternatif yakıtlar, çevre dostu düzenlemeler ile hava kalitesinin iyileştirilmesi artık ülke politikalarında yer almaktadır. Hava kalitesinin korunması amacıyla kirletici parametrelerin hem kaynaktaki hem de dış ortamdaki sınır değerlerinin azaltılmasına yönelik çalışmalar ülkemizde yürütülmektedir. Hava kalitesinin iyileştirilmesine yönelik politika belirlenmesinde mevcut durum tespiti büyük önem taşımaktadır. Mevcut durumun doğru olarak tespit edilebilmesi ve temiz hava eylem planlarının hazırlanabilmesi için ulusal ölçekte, kaynaklarına göre hava kirleticilerinin emisyon envanterinin hesaplanması, ulusal ve uluslararası sorumluluklar gereği atmosfere verdiğimiz emisyonların belirli periyotlarda raporlanması gerekmektedir. Bu nedenle, emisyon envanterinin belirli formatlarda, kirlilik kaynaklarına ait bilgiler ve emisyon faktörleri kullanılarak hazırlanması gerekmektedir. Bu çalışmada, Marmara Bölgesi pilot bölge seçilerek Çevre ve Şehircilik Bakanlığı ile birlikte ülkemizde ilk defa ulusal emisyon envanteri geliştirilmesi projesi gerçekleştirilmiştir. Bu çalışmadaki noktasal kaynaklar için yapılan kısım bu makalede anlatılmış ve metal sektörüyle ilgili elde edilen sonuçlar verilmiştir.
- 1 September 2021
- Published by Marmara University in International Journal of Advances in Engineering and Pure Sciences
- Vol. 33 (3) , 337-346
Noktasal Kaynaklar İçin Ulusal Hava Kirliliği Emisyon Faktörleri ve Envanterinin Belirlenmesi: Metal Sektörü İçin Örnek Bir Çalışma
Günümüzde hava kalitesinin korunması ve izlenmesi için yürütülen çalışmalar ve yasal uygulamalar, çevre bilincinin yerleşmesi ile daha da önemli hale gelmiştir. Gelişen teknolojiler, alternatif yakıtlar, çevre dostu düzenlemeler ile hava kalitesinin iyileştirilmesi artık ülke politikalarında yer almaktadır. Hava kalitesinin korunması amacıyla kirletici parametrelerin hem kaynaktaki hem de dış ortamdaki sınır değerlerinin azaltılmasına yönelik çalışmalar ülkemizde yürütülmektedir. Hava kalitesinin iyileştirilmesine yönelik politika belirlenmesinde mevcut durum tespiti büyük önem taşımaktadır. Mevcut durumun doğru olarak tespit edilebilmesi ve temiz hava eylem planlarının hazırlanabilmesi için ulusal ölçekte, kaynaklarına göre hava kirleticilerinin emisyon envanterinin hesaplanması, ulusal ve uluslararası sorumluluklar gereği atmosfere verdiğimiz emisyonların belirli periyotlarda raporlanması gerekmektedir. Bu nedenle, emisyon envanterinin belirli formatlarda, kirlilik kaynaklarına ait bilgiler ve emisyon faktörleri kullanılarak hazırlanması gerekmektedir. Bu çalışmada, Marmara Bölgesi pilot bölge seçilerek Çevre ve Şehircilik Bakanlığı ile birlikte ülkemizde ilk defa ulusal emisyon envanteri geliştirilmesi projesi gerçekleştirilmiştir. Bu çalışmadaki noktasal kaynaklar için yapılan kısım bu makalede anlatılmış ve metal sektörüyle ilgili elde edilen sonuçlar verilmiştir.
- Open Access
- 20 August 2021
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 25 (2) , 217-228
Phytoremediation of Boron using Lemna minor from Synthetic Aqueous Solutions and Real Geothermal Water
Bu çalışma kapsamında bor içeren sentetik çözeltilerin ve jeotermal suların Lemna minor L. bitkisi kullanılarak ıslahı çalışılmıştır. Çalışmada başlangıç bor konsantrasyonu, pH, arıtım hücresindeki su yüksekliği ve başlangıç hümik asit konsantrasyonlarının giderim verimi üzerine etkisi incelenmiştir. 5 mg L-1 başlangıç bor konsantrasyonu, pH 8 ve 1,5 cm su derinliğinde yürütülen deneysel çalışma ile maksimum bor giderim verimi % 96,7 olarak bulunmuştur. Başlangıç bor konsantrasyonunun 5’den 30 mg L-1’e yükseltilmesi ile bitkinin rengi ve yapısı yüksek bor içeriğinin bitki üzerindeki toksik etkisi nedeni ile bozulmuştur ve sonucunda giderim verimi 36,6% olarak bulunmuştur. SEM, FTIR ve kütle dengesi analizleri, bor giderim mekanizmasının esas olarak biyosorpsiyon olduğunu ortaya koymuştur. Ek olarak, jeotermal su arıtımı çalışmaları, L. minor'un 59,5% bor giderim verimliliği ile uygulanabilirliğini göstermiştir ve yüksek bor içeriğine sahip jeotermal suların son arıtımı için çalışmanın yüksek potansiyeli olduğunu kanıtlamıştır. In this study, phytoremediation performance of Lemna minor L. on boron removal from synthetic solution and real geothermal water was evaluated. Effects of initial boron concentration, initial pH, water height in cell, and initial humic acid concentration were investigated. The maximum removal efficiency was achieved as 96.7 % with the experimental run with 5 mg L-1 initial boron concentration, pH 8, and 1.5 cm water depth. Increasing the initial boron concentration from 5 to 30 mg L-1 resulted in a drastic decrease in removal efficiency to 36.6 %, due to the toxic effect of high boron content, which was clearly observed from deterioration of plant’s color and structure. SEM, FTIR, and mass balance analyses revealed that the boron removal mechanism was mainly biosorption. Geothermal water experiments indicated L. minor’s applicability with 59.5% removal efficiency, proving high potential in being used for post-treatment of geothermal waters with high boron content.
- 20 August 2021
- Published by SDU Journal of Natural and Applied Sciences in SDÜ Fen Bilimleri Enstitüsü Dergisi
- Vol. 25 (2) , 217-228
Open AccessPhytoremediation of Boron using Lemna minor from Synthetic Aqueous Solutions and Real Geothermal Water
Bu çalışma kapsamında bor içeren sentetik çözeltilerin ve jeotermal suların Lemna minor L. bitkisi kullanılarak ıslahı çalışılmıştır. Çalışmada başlangıç bor konsantrasyonu, pH, arıtım hücresindeki su yüksekliği ve başlangıç hümik asit konsantrasyonlarının giderim verimi üzerine etkisi incelenmiştir. 5 mg L-1 başlangıç bor konsantrasyonu, pH 8 ve 1,5 cm su derinliğinde yürütülen deneysel çalışma ile maksimum bor giderim verimi % 96,7 olarak bulunmuştur. Başlangıç bor konsantrasyonunun 5’den 30 mg L-1’e yükseltilmesi ile bitkinin rengi ve yapısı yüksek bor içeriğinin bitki üzerindeki toksik etkisi nedeni ile bozulmuştur ve sonucunda giderim verimi 36,6% olarak bulunmuştur. SEM, FTIR ve kütle dengesi analizleri, bor giderim mekanizmasının esas olarak biyosorpsiyon olduğunu ortaya koymuştur. Ek olarak, jeotermal su arıtımı çalışmaları, L. minor'un 59,5% bor giderim verimliliği ile uygulanabilirliğini göstermiştir ve yüksek bor içeriğine sahip jeotermal suların son arıtımı için çalışmanın yüksek potansiyeli olduğunu kanıtlamıştır. In this study, phytoremediation performance of Lemna minor L. on boron removal from synthetic solution and real geothermal water was evaluated. Effects of initial boron concentration, initial pH, water height in cell, and initial humic acid concentration were investigated. The maximum removal efficiency was achieved as 96.7 % with the experimental run with 5 mg L-1 initial boron concentration, pH 8, and 1.5 cm water depth. Increasing the initial boron concentration from 5 to 30 mg L-1 resulted in a drastic decrease in removal efficiency to 36.6 %, due to the toxic effect of high boron content, which was clearly observed from deterioration of plant’s color and structure. SEM, FTIR, and mass balance analyses revealed that the boron removal mechanism was mainly biosorption. Geothermal water experiments indicated L. minor’s applicability with 59.5% removal efficiency, proving high potential in being used for post-treatment of geothermal waters with high boron content.