EBEmre Bukusoglu

Emre Bukusoglu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Emre Bukusoglu has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Liquid crystal soft interfaces reveal molecular-level influences on microscopic flow characteristics

    by Cansu Erdil, Emre Bukusoglu

    Understanding boundary interactions at fluidic interfaces is critical for advancing synthetic and natural functional interfaces. However, classical hydrodynamic frameworks often fail to capture flow characteristics induced by localized molecular and ionic structuring at these boundaries. We present a microfluidic experimental oil–water co-flow platform, utilizing either a thermotropic liquid crystal (LC) or an isotropic oil, designed to systematically isolate the interfacial molecular and ionic mechanisms governing dynamic transport. Specifically, we provide experimental evidence of how water structuring, electroviscous drag, and molecular director alignment dictate interfacial flow, which remain poorly understood in conventional microfluidic systems. Our findings reveal that the precise spatial LC director configuration and ionic structuring at the interface fundamentally alter boundary layer slip conditions and drag. By bridging the long-standing gap between microscopic molecular events and macroscopic fluid mechanics near interfaces, this work introduces a design paradigm for engineering next-generation microfluidic and nanofluidic technologies, smart functional interfaces, and complex biological or technological systems.

  • Open Access

    Optically Active Birefringent Polymer–Lipid Hybrid Microparticles With Dual‐Stimuli Responsiveness

    by Burcu Okmen Altas, Emre Bukusoglu, Nihal Aydogan

    Organic‐material‐based hybrid microstructures that integrate structural anisotropy with dual‐stimuli responsiveness offer emerging opportunities for externally driven functional systems. We present multi‐functional dual‐stimuli‐responsive microparticles that exhibit optical birefringence due to their lamellar crystalline architecture, enabling label‐free detection under a polarized light. The anisotropic internal structure generates polarization‐dependent optical contrast, enabling label‐free tracking through birefringence‐based microscopy, with birefringence values (Δn) ranging from 0.04 to 0.07. Simultaneously, these microparticles are composed of polymer‐lipid material (polycaprolactone and stearic acid), magnetic nanoparticles (MNPs), and polypyrrole nanoparticles (PPy NPs), enabling responsiveness to both magnetic and near‐infrared (NIR) stimuli. The magnetic and photothermal responses of microparticles are investigated in aqueous solutions and under biologically relevant conditions. As a proof‐of‐concept demonstration, we show directional actuation in response to magnetic fields and NIR light in these multifunctional anisotropic microstructures, highlighting their potential for microrobotic applications. Furthermore, we show their low hemolytic activity and cytotoxicity, thereby confirming their biocompatibility. The present study introduces a pioneering integration of birefringent optical tracking into a dual‐stimulus soft‐material platform that possesses shapes depending on the formation condition, ranging from flower‐like to ship‐like. This innovation establishes a structure‐enabled, multifunctional soft‐material platform in which optical, magnetic, and thermal responses are intrinsically coupled within a single microstructure.


  • Open Access

    Nematic liquid crystal flow in microchannels with patterned anchoring

    by İrEm Özen, Metin Ege Ozdemir, Osman Karaman, Gorkem Gunbas, Giuseppe Negro, Livio Nicola Carenza, Emre Bukusoglu

    Non-Newtonian microfluidics play a crucial role in modern industrial and technological advancements, and in biological phenomena. We report how local variations in the alignment at the boundary of nematic liquid crystals (LCs) govern their flow characteristics under pressure-driven microfluidic conditions. Specifically, we micropatterned the LC anchoring conditions using a photocleavable self-assembled monolayers and investigated the resulting flow characteristics through measurement of flow resistances, and spatial variations in LC director fields as a function of the microfluidic flow. Combined experimental measurements and computational simulations showed that patterned anchoring induces pronounced coupling between flow and molecular alignment, leading to spatially heterogeneous flow regimes revealing backflow mechanisms, hysteresis, pattern-dependent, and rich topological structures. These findings establish a framework for controlling soft anisotropic fluids through interfacial patterning, offering new opportunities for adaptive and reconfigurable microfluidic systems.


  • Open Access

    Nanoparticle-Induced Interfacial Director Straining Enables Ultrasensitive Molecular Detection at Microfluidic Liquid Crystal Interfaces

    by Pouriya Esmaeilzadeh, Emre Bukusoglu

    Detecting aqueous trace pollutants is a challenge in tracking environmental and public health. We report nanoparticle-decorated liquid crystal (LC) soft interfaced microfluidic platforms for detecting trace-level aqueous analytes. Silica nanoparticles functionalized with alkyl-terminated silanes were used to decorate the LC-aqueous interfaces and induce LC strain. The response of the LC flow sensor to various analytes, including industrial dyes, pharmaceuticals, and persistent chemicals, was investigated through the optically observable LC ordering transitions. The microfluidic results, supported by nanoparticle-integrated LC droplet-based sensors, showed a limit of detection (LOD) of 0.1 ppb with LC interfaces decorated with concentrated nanoparticles. Lowering the interfacial nanoparticle loading resulted in sensors achieving an impressive 4 orders of magnitude reduction in the LOD. While LC droplet-based sensors were unable to reach this sensitivity limit, such ultralow responses were strikingly observed in microfluidic sensor platforms by leveraging the interface geometry and localized straining at LC interfaces induced by nanoparticle positioning. We show that the sensors demonstrate selectivity for analytes characterized by aromatic structures. These features hold potential for various applications, including continuous tracking of micropollutants and medical diagnostics.

  • Open Access

    Soft-interfaced liquid crystal microfluidics can probe the rigidity of lipid vesicles

    by Cansu Dedeoglu, Emre Bukusoglu

    Liquid crystal (LC)-aqueous interfaces were shown to respond to the phospholipid interactions via optically observable ordering transitions; however, past attempts lack the quantification of the transport and fusion kinetics of the vesicles at the interfaces. Herein, we investigated the response of flowing LC-aqueous interfaces upon fusion of the vesicles formed by pure 1,2-dilauroyl-sn-glycero-3-phosphocholine (DLPC), 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC), 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), or egg sphingomyelin or their mixtures with guest molecules. Using stabilized LC-aqueous interfaces in transparent microfluidic chips that allow spatiotemporal quantification using fluorescence, confocal, and polarized light microscopy, we demonstrated that flowing LC interfaces provide a rapid response to lipid adsorption, where their spatiotemporal interfacial distribution differs depending on the mechanical properties of their vesicles. We show that cholesterol-dissolved lipid complexes result in distinct LC-response kinetics, mainly associated to the changes in their rigidities. Considering the critical role of the mechanical properties of cell membranes in proper cellular function, this study is significant as it offers a continuous and rapid early diagnosis platform for detecting minor mechanical alterations in lipid bilayers, which may lead to cell dysfunction that contributes to critical diseases.


  • Open Access

    Engineered Fullerene-Based Enzyme Mimics for Enhanced Sensing of Aqueous-Phase Reactions Using Liquid Crystals

    by Deniz Karaman, Elif Akar, Aytül Saylam, Salih Özçubukçu, Emre Bukusoglu


  • Open Access

    Liquid Crystals that Respond to the Aqueous Phase Reactions Catalyzed by Synthetic Enzyme Mimics

    by Deniz Karaman, Aytül Saylam, Elif Akar, Salih Özçubukçu, Emre Bukusoglu

    Liquid crystal (LC)‐aqueous soft interface sensors have shown potential toward a wide range of analytes, which also include tracking of their reactions. While these sensors have shown promise in studying enzymatic activity, they have been limited to natural enzymes. A whole‐synthetic approach is introduced for the detection of molecular species through their interactions with enzyme mimics. Highly stable and robust, fullerene‐based synthetic enzyme mimics are employed, and the response of nematic LC droplets to their hydrolysis activity is investigated. This involves characterizing the structures of the LC droplets in the aqueous phase that facilitate enzymatic reactions, monitoring the responses of LC droplets to these interactions to sense enzymatic activity. Polarized light microscopy is employed to image the LC droplets, spectrophotometry to measure kinetics, and interfacial tension measurements for structural characterization of LC interfaces. These findings revealed an instantaneous response of the LC droplets that originate from the enzyme mimic‐substrate interactions in the bulk phase, and the presence of the LC droplets does not noticeably influence the function and interactions of the enzyme mimics. These findings offer a new perspective on LC‐based sensing systems that can be tailored to a wide range of substrates or enzyme‐substrate interactions.


  • Open Access

    Shear-induced structural transitions in confined nematic soft interfaces

    by Gülce İlHan, Livio Nicola Carenza, Emre Bukusoglu

    Research on aqueous-interfaced liquid crystals (LCs) offered valuable outcomes leading to successful applications in sensing and actuation systems. The forward leap of the promising findings in stagnant LC systems will be achieved by the integration of LCs into automated flow systems. In fundamental microfluidics studies, the structural transitions of LC were induced by external fields; yet they were constrained to hard-interfaced flow confinements. In this study, we investigate the structural transitions in flowing nematic LCs confined in microfluidic channels with accessible, stable LC-aqueous soft interfaces. We demonstrate in experiments and in simulations that the applied bulk and interfacial shear significantly transform the director configurations of the nematic LC, due to the anchoring properties at the soft interface. The director profiles, as well as the topology, are influenced substantially by the mechanical stresses induced at the vicinity of the aqueous interfaces depending on the interfacial anchoring conditions, bulk nematic directors, and the direction of the shear. The experimental observations presented herein will guide the ongoing research on the flow of LC in microenvironments and are likely to open new horizons in the development of autonomous platforms including more complex LC phases.


  • Open Access

    Responsive Soft Interface Liquid Crystal Microfluidics

    by Ayşe Nurcan Özşahin, Emre Bukusoglu

    The multifunctional responsive interfaces of liquid crystal (LC) and water are employed in fundamental research (colloidal assembly) and promising applications (sensing, release, and material synthesis). The stagnant LC systems, however, limit their use in continuous, automated applications. A microfluidic platform is reported where stable LC flow is maintained between aqueous interfaces. The LC‐water soft interface is defined by the preferential wetting of the two phases at the chemically heterogeneous microchannel interfaces. It is shown that the LC‐water interfaces are stable up to significant pressure differences across the interfaces and maintain responsive characteristics. The stability is in a range to cover the perpendicular and flow‐aligned regimes at low and high flow velocities, respectively, in co‐current or counter‐current flow configurations. The LC configuration at the vicinity of the aqueous interfaces is influenced by the shear induced by the bulk LC flow and by the contacting aqueous phases allowing modulation of the LC strain at the responsive interfaces. The simplicity of the construction and operation of the soft‐interface LC flow platform shows promise and meets the fundamental requirements for their integration into next‐generation autonomous platforms.


  • Open Access

    Cross-Linked Cellulose Nanocrystal Membranes with Cholesteric Assembly

    by Berk C. İçTen, Emre Bukusoglu, P. Zeynep Çulfaz-Emecen

    Forming membranes by tangential flow deposition of cellulose nanocrystal (CNC) suspensions is an attractive new approach to bottom-up membrane fabrication, providing control of separation performance using shear rate and ionic strength. Previously, the stabilization of these membranes was achieved by irreversibly coagulating the deposited layer upon the permeation of a high-ionic-strength salt solution. Here, we demonstrate for the first time the chemical cross-linking of carboxyl-containing TEMPO-oxidized CNCs by Ag(I)-catalyzed oxidative decarboxylation and the stabilization of CNC membranes using this post-treatment. Cross-linking of TEMPO-CNCs was first demonstrated in suspension via turbidity, dynamic light scattering, and storage (G') and loss (G″) moduli measurements. Membranes were formed by filtering a 0.15 wt % TEMPO-CNC suspension onto a porous support, followed by permeation of the cross-linking solution containing AgNO3 and KPS through the deposited layer. Rejection for Blue Dextran with a 5 kDa molecular weight was 95.3 ± 1.9%, 90.6 ± 3.7%, and 95.9 ± 1.0% for membranes made from suspensions of TEMPO-CNC, desulfated TEMPO-CNC. and TEMPO-CNC with 100 mM NaCl, respectively. Suspensions with added NaCl led to membranes with improved stability and cholesteric self-assembly in the membrane layer. Membranes subjected to cross-linking post-treatment remained intact upon drying, while those stabilized physically using 200 mM AlCl3 solution were cracked, demonstrating the advantage of the cross-linking approach for scale-up, which requires drying of the membranes for module preparation and storage.