Gabriele Woebker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gabriele Woebker has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
A.N. Obeid
Oxford Optronics
1 shared publicationAndreas Hecker
1 shared publicationAndreas Weyland
Department of Anesthesiology, Intensive Care Medicine, Emergency Medicine, and Pain Therapy, Hospital Oldenburg, Oldenburg, Germany
1 shared publicationAnna Leidorf
University Medical Center of the Johannes Gutenberg University, Institut for Neurosurgical Pathophysiology, Langenbeckstr 1, Mainz, Germany
1 shared publicationArmin Sommerer
Department of Anesthesiology and Intensive Care Medicine, Bundeswehrkrankenhaus Berlin, Berlin, Germany
1 shared publication- Axel Heimann
Institute for Neurosurgical Pathophysiology, University Medicine of the Johannes Gutenberg-University Mainz, Mainz, Germany
1 shared publication
Latest Publications
- 16 June 2017
- Published by SAGE Publications in Perfusion
- Vol. 32 (8) , 698-701
Perioperative single-site veno-venous extracorporeal CO2 removal for minimally invasive giant bulla resection
Giant pulmonary bullae are rare and surgical management of patients with severe emphysema and advanced chronic obstructive lung disease (COPD) presenting with giant bullae can be very challenging. Previously, perioperative, two-site, high-flow, veno-venous extracorporeal membrane oxygenation (ECMO) was successfully utilized during giant bulla resection. Here we report the perioperative application of single-site, low-flow extracorporeal CO2 removal (ECCO2R) for minimally invasive thoracoscopic giant bulla resection. This approach of low-flow, veno-venous ECCO2R, which is less invasive than conventional ECLS approaches, has enabled the safe performance of surgery and facilitated protective intraoperative single-lung ventilation while avoiding possible complications of aggressive mechanical ventilation.
- 16 June 2017
- Published by SAGE Publications in Perfusion
- Vol. 32 (8) , 698-701
Perioperative single-site veno-venous extracorporeal CO2 removal for minimally invasive giant bulla resection
Giant pulmonary bullae are rare and surgical management of patients with severe emphysema and advanced chronic obstructive lung disease (COPD) presenting with giant bullae can be very challenging. Previously, perioperative, two-site, high-flow, veno-venous extracorporeal membrane oxygenation (ECMO) was successfully utilized during giant bulla resection. Here we report the perioperative application of single-site, low-flow extracorporeal CO2 removal (ECCO2R) for minimally invasive thoracoscopic giant bulla resection. This approach of low-flow, veno-venous ECCO2R, which is less invasive than conventional ECLS approaches, has enabled the safe performance of surgery and facilitated protective intraoperative single-lung ventilation while avoiding possible complications of aggressive mechanical ventilation.
- 1 April 2015
- Published by Elsevier in Journal of Critical Care
- Vol. 30 (2) , 439.e1-439.e6
Hyperlactatemia is an independent predictor of mortality and denotes distinct subtypes of severe sepsis and septic shock
- 1 April 2015
- Published by Elsevier in Journal of Critical Care
- Vol. 30 (2) , 439.e1-439.e6
Hyperlactatemia is an independent predictor of mortality and denotes distinct subtypes of severe sepsis and septic shock
- 1 January 2014
- Published by Turkish Neurosurgical Society in Turkish Neurosurgery
- Vol. 24 (6) , 913-22
Description of the response of a new multi-parametric brain sensor to physiological and pathophysiological challenges in the cortex of juvenile pigs
Monitoring of intracranial pressure (ICP), local cerebral blood flow (CBF) and oxygen is part of modern intensive critical care medicine. Preclinical evaluation of newly developed catheters that should monitor several parameters simultaneously is reported poorly in the literature. The goal of our study was (1) to evaluate a new multi-parametric sensor in brain tissue and (2) to establish a testing protocol using pathophysiological challenges that target measured parameters of the sensor and autoregulatory boundaries and could be used as preclinical standard protocol in future studies. We describe data from 12 new multi-parametric brain sensors (MPBS) that were implanted into 3 porcine brains and combined measurement of brain tissue oxygenation (ptiO2), ICP, CBF and brain temperature for the first time. Pigs were treated with a period of hyperoxygenation, hypercapnia, hypoxia, dobutamine, and norepinephrine. None of the 12 MPBS failed. Our testing protocol induced standardized pathophysiological changes that were picked up by the new MPBS as significant alterations in brain ptiO2, ICP and CBF. The magnitude of changes was >20% in most tested MPBS. An experimental protocol with pre-defined end-points for O2, CO2, blood pressure and cardiac output should be standardized and reported if new sensors for multi-parametric brain monitoring are evaluated. The use of several sensors per brain of only a few animals is sufficient to determine functionality of new sensors in vivo as basis for a larger study with reference sensors and brain injury.
- 1 January 2014
- Published by Turkish Neurosurgical Society in Turkish Neurosurgery
- Vol. 24 (6) , 913-22
Description of the response of a new multi-parametric brain sensor to physiological and pathophysiological challenges in the cortex of juvenile pigs
Monitoring of intracranial pressure (ICP), local cerebral blood flow (CBF) and oxygen is part of modern intensive critical care medicine. Preclinical evaluation of newly developed catheters that should monitor several parameters simultaneously is reported poorly in the literature. The goal of our study was (1) to evaluate a new multi-parametric sensor in brain tissue and (2) to establish a testing protocol using pathophysiological challenges that target measured parameters of the sensor and autoregulatory boundaries and could be used as preclinical standard protocol in future studies. We describe data from 12 new multi-parametric brain sensors (MPBS) that were implanted into 3 porcine brains and combined measurement of brain tissue oxygenation (ptiO2), ICP, CBF and brain temperature for the first time. Pigs were treated with a period of hyperoxygenation, hypercapnia, hypoxia, dobutamine, and norepinephrine. None of the 12 MPBS failed. Our testing protocol induced standardized pathophysiological changes that were picked up by the new MPBS as significant alterations in brain ptiO2, ICP and CBF. The magnitude of changes was >20% in most tested MPBS. An experimental protocol with pre-defined end-points for O2, CO2, blood pressure and cardiac output should be standardized and reported if new sensors for multi-parametric brain monitoring are evaluated. The use of several sensors per brain of only a few animals is sufficient to determine functionality of new sensors in vivo as basis for a larger study with reference sensors and brain injury.
- 31 December 2008
- Published by Springer Nature
- Vol. 645, 175-180
One Sensor Fits All – A New Approach In Monitoring Brain Physiology
Oxygen plays a pivotal role as a nutrient to the brain. Monitoring partial pressure of oxygen (ptO2) has been shown to correlate with outcome after brain injury if certain tissue-ptO2-goals can be achieved. Oxford Optronix has recently developed a new fiber-optic based sensor (MPBS) with a large tissue sampling volume and long-term stability up to 10 days. Direct comparison of the MPBS sensor with the Licox system was performed using an in-vitro and in-vivo model. No statistically significant differences between the MPBS and the Licox sensor in different settings were found. The response times to a sudden drop in ptO2 was faster for the MPBS than for the Licox probes (time of 80% signal change; 65 +/- 11 vs 110 +/- 14 s; p<0.05).
- 31 December 2008
- Published by Springer Nature
- Vol. 645, 175-180
One Sensor Fits All – A New Approach In Monitoring Brain Physiology
Oxygen plays a pivotal role as a nutrient to the brain. Monitoring partial pressure of oxygen (ptO2) has been shown to correlate with outcome after brain injury if certain tissue-ptO2-goals can be achieved. Oxford Optronix has recently developed a new fiber-optic based sensor (MPBS) with a large tissue sampling volume and long-term stability up to 10 days. Direct comparison of the MPBS sensor with the Licox system was performed using an in-vitro and in-vivo model. No statistically significant differences between the MPBS and the Licox sensor in different settings were found. The response times to a sudden drop in ptO2 was faster for the MPBS than for the Licox probes (time of 80% signal change; 65 +/- 11 vs 110 +/- 14 s; p<0.05).
- 22 November 2005
- Published by Wolters Kluwer Health in Neurology
- Vol. 65 (10) , 1674-1675
Herpes encephalitis after meningioma resection
- 22 November 2005
- Published by Wolters Kluwer Health in Neurology
- Vol. 65 (10) , 1674-1675
Herpes encephalitis after meningioma resection
- 1 February 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 102 (2) , 318-327
Multimodal metabolic imaging of cerebral gliomas: positron emission tomography with [18F]fluoroethyl-l-tyrosine and magnetic resonance spectroscopy
Object. The purpose of this study was to determine the predictive value of [18F]fluoroethyl-l-tyrosine (FET)—positron emission tomography (PET) and magnetic resonance (MR) spectroscopy for tumor diagnosis in patients with suspected gliomas. Methods. Both FET-PET and MR spectroscopy analyses were performed in 50 consecutive patients with newly diagnosed intracerebral lesions supposed to be diffuse gliomas on contrast-enhanced MR imaging. Lesion/brain ratios of FET uptake greater than 1.6 were considered positive, that is, indicative of tumor. Results of MR spectroscopy were considered positive when N-acetylaspartate (NAA) was decreased in conjunction with an absolute increase of choline (Cho) and an NAA/Cho ratio of 0.7 or less. An FET lesion/brain ratio, an NAA/Cho ratio, and signal abnormalities on MR images were compared with histological findings in neuronavigated biopsy specimens. The FET lesion/brain ratio and the NAA/Cho ratio were identified as significant independent predictors for the histological identification of tumor tissue. The accuracy in distinguishing neoplastic from nonneoplastic tissue could be increased from 68% with the use of MR imaging alone to 97% with MR imaging in conjunction with FET-PET and MR spectroscopy. Sensitivity and specificity for tumor detection were 100 and 81% for MR spectroscopy and 88 and 88% for FET-PET, respectively. Results of histological studies did not reveal tumor tissue in any of the lesions that were negative on FET-PET and MR spectroscopy. In contrast, a tumor diagnosis was made in 97% of the lesions that were positive with both methods. Conclusions. In patients with intracerebral lesions supposed to be diffuse gliomas on MR imaging, FET-PET and MR spectroscopy analyses markedly improved the diagnostic efficacy of targeted biopsies.
- 1 February 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 102 (2) , 318-327
Multimodal metabolic imaging of cerebral gliomas: positron emission tomography with [18F]fluoroethyl-l-tyrosine and magnetic resonance spectroscopy
Object. The purpose of this study was to determine the predictive value of [18F]fluoroethyl-l-tyrosine (FET)—positron emission tomography (PET) and magnetic resonance (MR) spectroscopy for tumor diagnosis in patients with suspected gliomas. Methods. Both FET-PET and MR spectroscopy analyses were performed in 50 consecutive patients with newly diagnosed intracerebral lesions supposed to be diffuse gliomas on contrast-enhanced MR imaging. Lesion/brain ratios of FET uptake greater than 1.6 were considered positive, that is, indicative of tumor. Results of MR spectroscopy were considered positive when N-acetylaspartate (NAA) was decreased in conjunction with an absolute increase of choline (Cho) and an NAA/Cho ratio of 0.7 or less. An FET lesion/brain ratio, an NAA/Cho ratio, and signal abnormalities on MR images were compared with histological findings in neuronavigated biopsy specimens. The FET lesion/brain ratio and the NAA/Cho ratio were identified as significant independent predictors for the histological identification of tumor tissue. The accuracy in distinguishing neoplastic from nonneoplastic tissue could be increased from 68% with the use of MR imaging alone to 97% with MR imaging in conjunction with FET-PET and MR spectroscopy. Sensitivity and specificity for tumor detection were 100 and 81% for MR spectroscopy and 88 and 88% for FET-PET, respectively. Results of histological studies did not reveal tumor tissue in any of the lesions that were negative on FET-PET and MR spectroscopy. In contrast, a tumor diagnosis was made in 97% of the lesions that were positive with both methods. Conclusions. In patients with intracerebral lesions supposed to be diffuse gliomas on MR imaging, FET-PET and MR spectroscopy analyses markedly improved the diagnostic efficacy of targeted biopsies.