ACAlan Cottenden

Alan Cottenden

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alan Cottenden has a total of 320 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Trial to compare mixed-use (multi-use and single-use) intermittent catheter management with single-use management over 12 months (The MultICath Trial): protocol for a non-inferiority randomised controlled trial

    by Mandy Fader, Margaret Macaulay, Nina Wilson, Nicola Goudie, Thomas J Chadwick, Alaa Abouhajar, Jeremy Jones, Gillian Watson, Miriam R Avery, Jackie Broadbridge, et al.

    Introduction Evaluating the safety and acceptability of reusing catheters for intermittent catheterisation (IC) is one of the top 10 continence research priorities identified by the UK James Lind Alliance Priority Setting Partnership in 2008. There are an estimated 50 000 IC users in England and this number is rising. Globally, both single-use catheters (thrown away after use) and multi-use/reusable ones (cleaned between uses) are used. Using multi-use catheters as well as single-use ones (mixed-use) could bring benefits (eg, reducing plastic waste and patients never running out of catheters) and offer more choice to users. Evidence is needed that mixed-use is at least as safe and acceptable as using only single-use catheters. Methods The MultICath Trial is a non-inferiority randomised controlled trial involving 578 participants. The aim is to compare mixed-use catheter management with single-use catheter management over 12 months. Participants are randomised on a 1:1 basis to either mixed-use catheter management, which includes an evidence-based cleaning method for the multi-use catheters (intervention) or single-use catheter management (control). Following randomisation, participants are followed up for 12 months. The primary outcome is at least one episode of microbiologically confirmed symptomatic urinary tract infection with help-seeking or self-help behaviour over the 12-month follow-up period. Laboratory analysis of patient-initiated urine samples is blind. Secondary outcomes include antibiotic use, microhaematuria, visible blood on catheter/in urine, quality of life and health economics. A qualitative sub-study to examine participant experiences using mixed-use is included. Ethics and dissemination Ethical review was undertaken by South Central-Hampshire A Research Ethics Committee and favourable opinion was granted on 12 July 2019 (reference: 19/SC/0334). Written, informed consent to participate was obtained from all participants. Results will be disseminated in peer-reviewed publications, in the National Institute for Health and Care Research journal library and to participants and the public via a lay summary published on the trial website. Trial registration number ISRCTN42028483.


  • Open Access

    Technology for managing incontinence: What are the research priorities?

    by Mandy Fader, Cathy L Murphy, Donna Z Bliss, Brian S Buckley, Rowan Cockerell, Alan M Cottenden, Jan Kottner, Joan Ostaszkiewicz

    Incontinence and toileting difficulties can often be successfully addressed by treating their underlying causes. However, (complete) cure is not always possible and continence products to prevent or contain unresolved leakage or to facilitate toileting are in widespread use. Many people use them successfully but identifying the product(s) most likely to meet individual needs can be challenging and the recently published Seventh International Consultation on Incontinence includes a chapter which draws on the literature to provide evidence-based recommendations to help clinicians and product users to select appropriate products. This paper is based on the same evidence, but reviewed from the different perspective of those keen to identify unmet needs and develop improved products. For each of the main continence product categories it (i) outlines the design approach and key features of what is currently available; (ii) provides a generic functional design specification; (iii) reviews how well existing products meet the requirements of their main user groups; and (iv) suggests priorities for the attention of product designers. It also flags some core scientific problems which – if successfully addressed – would likely yield benefits in multiple incontinence product contexts.


  • Open Access

    Management using continence products: Report of the 7th International Consultation on Incontinence

    by Cathy Murphy, Mandy Fader, Donna Z. Bliss, Brian Buckley, Rowan Cockerell, Alan Cottenden, Jan Kottner, Joan Ostaszkiewicz


  • Open Access

    An International Continence Society (ICS) report on the terminology for single‐use body worn absorbent incontinence products

    by Mandy Fader, Alan Cottenden, Chris Chatterton, Helena Engqvist, Sharon Eustice, Diane K. Newman, Joan Ostaszkiewicz, Mary H. Palmer, Tara Willson, Bernard Haylen

    Aims In 2016, the International Continence Society (ICS) Standardization Steering Committee appointed a working group to address the confusing plethora of synonyms currently used to describe single‐use body worn absorbent incontinence products by recommending preferred terminology. Methods An online questionnaire was posted in 2016/17 inviting input from stakeholders internationally. The data were analyzed and conclusions progressively refined through working group discussions, an open meeting at the 2017 annual ICS conference, and a review of further iterations—including from the parent ICS Standardization Committee—until consensus was reached. Partway in, the International Organization for Standardization started a project with similar scope and the two organizations liaised to harmonize their conclusions while respecting each other's processes. Results A hundred people from 18 countries responded to the questionnaire. About a third (32.2%) of those declaring their nationality were from the UK and a further third (34.5%) from other English‐speaking countries. Two‐thirds (67.8%) lived in Europe; around a quarter (23%) in North America; and 9.2% in Australasia. Seven main design categories of products were identified and, while clear consensus was readily achieved in naming some of them, others required more work to determine the best term among multiple contenders. Conclusions The working group concluded that the seven product design categories should be called: (a) pads; (b) unbacked pads; (c) male pads; (d) male pouches; (e) pull‐on pads (protective underwear); (f) all‐in‐ones (wrap‐around pads, adult briefs); and (g) belted pads (belted products), in which the bracketed terms are judged acceptable (though not preferred) alternatives.


  • In vivo estimation of water diffusivity in occluded human skin using terahertz reflection spectroscopy

    by Qiushuo Sun, Rayko I. Stantchev, Jiarui Wang, Edward P. J. Parrott, Alan Cottenden, Tor‐Wo Chiu, Anil T. Ahuja, Emma Pickwell‐MacPherson

    Water diffusion and the concentration profile within the skin significantly affect the surrounding chemical absorption and molecular synthesis. Occluding the skin causes water to accumulate in the top layer of the skin (the stratum corneum) and also affects the water diffusivity. Scar treatments such as silicone gel and silicone sheets make use of occlusion to increase skin hydration. However with existing techniques, it is not possible to quantitatively measure the diffusivity of the water during occlusion: current methods determine water diffusivity by measuring the water evaporated through the skin and thus require the skin to breathe. In this work we use the high sensitivity of terahertz light to water to study how the water content in the stratum corneum changes upon occlusion. From our measurements, we can solve the diffusion equations in the stratum corneum to deduce the water concentration profile in occluded skin and subsequently to determine the diffusivity. To our knowledge this is the first work showing how the diffusivity of human skin can be measured during occlusion and we envisage this paper as being used as a guide for non‐invasively determining the diffusivity of occluded human skin in vivo.


  • An experimental study of friction between volar forearm skin and nonwoven fabrics used in disposable absorbent products for incontinence

    by Sabrina S Falloon, Vasileios Asimakopoulos, Alan M Cottenden

    Incontinence-associated dermatitis is common among wearers of absorbent incontinence products and friction between product materials and skin is thought to be a contributing factor, but the details of its role are unclear. In this study, friction was measured between the dry volar forearm of 19 women (20–95 years) and five nonwovens typical of those in commercial disposable products. Euler’s model/Amontons’ law held to high precision for all person–fabric pairs for both static and dynamic friction, despite substantial variations in forearm size, soft tissue compliance and skin smoothness between subjects, sometimes substantial lateral contraction in fabric strips, and skin rucking beneath them. For a given subject, the highest coefficients of friction among the fabrics exceeded the lowest by ∼30% to 75%, while – for a given fabric – the highest coefficients of friction among the subjects exceeded the lowest by ∼55% to 85%. The order of coefficient of friction values across fabrics was similar for each subject, and across subjects for each fabric. There was no systematic variation with subject age. The data were well modelled by estimating the coefficients of friction for a given person–fabric combination as the product of the mean coefficient of friction across all fabrics for that person, and the mean coefficient of friction across all persons for that fabric, normalised to the mean coefficient of friction across all person–fabric combinations. Predicted values were within 10% of measured figures for ∼97% of person–fabric combinations. Stick-and-slip behaviour was observed with seven person–fabric combinations, but especially strongly for two subjects with each of two fabrics. It is not clear why and further investigation is merited. Comparison of the data with results from earlier work with the same fabrics and a skin surrogate (Lorica Soft) suggests that measurements with Lorica Soft may be helpful to screen, evaluate and compare candidate materials preparatory to human studies.


  • Open Access

    An investigation of laboratory test methods for predicting the in-use leakage performance of urine-absorbing aids in nursing homes

    by Alan Cottenden, Margaret Macaulay

    The absorption before leakage method for measuring the absorption capacity of urine-absorbing aids was investigated. Along with the existing international standard (ISO 11948-1:1996, the Rothwell method), it was run on 12 experimental products whose in-use leakage performance was established by 55 incontinent nursing home residents. Methods were evaluated by considering their simplicity, their repeatability within – and their reproducibility between – six laboratories, and their correlation with in-use product performance. ISO 11948-1:1996 – which measures the absorption capacity of products under simple conditions – showed good repeatability and reproducibility, and reasonable correlation with in-use data. However, it proved blind to the effects of leg cuffs that conferred measurable benefits in real use. It should, therefore, be used with caution. The absorption before leakage method – which measures how much a product will hold before leakage when it is mounted on a manikin and standard aliquots of liquid are applied – is more complex and had poorer repeatability and reproducibility. However, it had stronger correlations with in-use data and successfully detected the benefits of leg cuffs on insert products. It is concluded that it holds potential as a new international standard to replace or complement ISO 11948-1:1996, and the necessary refinement work has been ongoing since the 2007 project described here. Two other laboratory methods were run opportunistically. A rewet method (Spanish national standard UNE 153601-2:2008) – for measuring the escape of fluid from a product under pressure – showed poor repeatability and reproducibility. Finally, an acquisition method was used to measure how quickly products absorbed two successive standard aliquots of liquid. It proved robust, showing good repeatability and reproducibility. Although measurements generally correlated well with in-use leakage performance, a direct causal link is unlikely. Products with high absorption capacity tend also to absorb quickly.


  • Top Cited Papers

    6th International Consultation on Incontinence. Recommendations of the International Scientific Committee: EVALUATION AND TREATMENT OF URINARY INCONTINENCE, PELVIC ORGAN PROLAPSE AND FAECAL INCONTINENCE

    by Paul Abrams, Karl‐Erik Andersson, Apostolos Apostolidis, Lori Birder, Donna Bliss, Linda Brubaker, Linda Cardozo, David Castro‐Diaz, P.R. O'COnnell, Alan Cottenden, et al.