LCLim Kwong Cheung

Lim Kwong Cheung

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lim Kwong Cheung has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Orbit Segmentation by Surface Reconstruction With Automatic Sliced Vertex Screening

    by Tai-Chiu Hsung, John Lo, Mei-Man Chong, Tazuko K. Goto, Lim-Kwong Cheung

    In segmentation of human orbit in computer tomography (CT) images, traditional approaches are slice-by-slice manual editing or shape interpolation with selected slices interactively. It is not only time consuming, but also inefficient, exhibits inter-operator variability and repeatability problems. In this study, we aim to develop a computational approach to the segmentation of orbits. The first step is to perform Hounsfield unit thresholding to segment the bony structure around the orbit. Then a three dimensional (3D) mesh model is generated. Poisson surface reconstruction is applied to a set of automatically screened vertices, which are facing the inner orbital walls. These procedures effectively close orbital fissures; various nerves foramina; and interpolate the broken surfaces due to thin bone structures around the orbit. We also developed validation models with five dried skulls and clinical CT images, where the orbits were filled with dental impression. Validations on the proposed algorithm were performed with the corresponding CT images and verified by experienced radiographer. The mean volume differences are less than 0.3%. Surface differences are within 0.3 mm of root mean square (RMS). Both differences are not clinically significant. Significance: Traditional approaches are slice-by-slice manual editing or shape interpolation with selected slices interactively. It is not only time consuming, but also inefficient, exhibits inter-operator variability and repeatability problems. In the proposed method, most of the manual processes are eliminated with adjustable vertex screening parameters. It makes the proposed method repeatable.


  • Open Access

    Psychosocial and Quality of Life Outcomes of Prosthetic Auricular Rehabilitation with CAD/CAM Technology

    by Chi Keung Tam, Colman Patrick McGrath, Samuel Mun Yin Ho, Edmond Ho Nang Pow, Henry Wai Kuen Luk, Lim Kwong Cheung

    Introduction. The psychosocial and quality of life (QoL) of patients with deformed or missing ears are frequently compromised. The aim of this study is to develop innovative techniques using CAD/CAM technology in prosthetic auricular rehabilitation and provide improvement in the treatment outcomes, including their psychology and QoL.Methods. This is a preliminary clinical cohort study. Six patients requesting for auricular reconstruction were recruited and rehabilitated with implant-supported prosthesis using CAD/CAM technology. Different treatment outcomes including QoL and psychological changes were assessed at different time points.Results. A significant reduction in severity of depressive symptoms(P=0.038)and an improving trend of satisfaction with life were found at 1 year postoperatively when compared with the preoperative findings. The domain scores in ‘‘Body image’’, ‘‘Family/friends/strangers’’, and ‘‘Mood’’ were also significantly higher(P<0.05)at 1 year postoperatively than 1 week postoperatively. However, only 50% of the patients wear their auricular prosthesis regularly.Conclusion. This preliminary study has confirmed that implant-supported auricular prosthesis could induce improvement in the psychology and QoL with statistically significant differences in the domains of the body image, social interaction, and mood. Our present findings can inform research design and hypotheses generation of future studies.


  • Responses of distraction regenerate to high-frequency traction at a rapid rate

    by Xi Ling Liu, Hua Xiang Zhang, Li Ma, Lin Peng, Lim Kwong Cheung, Li Wu Zheng

    Continuous traction is capable of creating an optimal biological environment for bone healing which may finally compensate for the rapid distraction rate in distraction osteogenesis. This study was designed to investigate the response of distraction callus to continuous distraction at a rapid rate using a rabbit model of mandibular lengthening. Thirty adult New Zealand white rabbits were randomly assigned to the intermittent (1 step/d) or continuous distraction (8 steps/s) group, with 15 in each. After osteotomy, manual-driven or autodriven distractor was adapted accordingly. The distraction was activated at a rate of 3.0 mm/d for 4 days. Five rabbits in each group were killed at week 2, week 4, and week 12 of consolidation, respectively. Plain radiography, microcomputed tomography, and histology examinations were used to evaluate the bone regeneration status. Plain radiographs and histologic studies demonstrated more advanced bone healing in continuous distraction group than that in intermittent distraction group at all the examined time points. Quantitative microcomputed tomography analysis showed significantly higher bone volume in continuous distraction group at week 2 (p < 0.01) and week 4 (p < 0.05) of consolidation. Continuous traction by autodriven distractor could be a promising clinical alternative to shorten the treatment course of distraction osteogenesis. Further studies to test its clinical potential using large animals that have similar metabolic rate and muscular resistance with human being are necessary.


  • Quasi-Continuous Autodriven System With Multiple Rates for Distraction Osteogenesis

    by Li Wu Zheng, Martin C. M. Wong, Lim Kwong Cheung

    Introduction. For a given rate of distraction a greater frequency of distraction improves bone formation. However, the current distractors used in clinic are activated manually and produces intermittent advancement. Method. The authors developed an automatic driver that is capable of producing quasi-continuous distraction at a set of rates of 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm/d. Using a customized in vitro experimental system, the function and stability of the autodriven system were tested during loading. Results. The angular displacement of the automatic driver was quite regular while driving a constant torque of 4.268 × 10−3 kg m. The driving achieved the target speed with the constant torque. Conclusions. The automatic driven system provides a useful tool to assess the tissue healing at variable distraction rates with quasi-continuous traction. It demonstrates a potential for clinical application to shorten the treatment course of distraction osteogenesis.


  • Open Access

    Three‐dimensional photogrammetry for surgical planning of tissue expansion in hemifacial microsomia

    by Yasas S. N. Jayaratne, John Lo, Roger A. Zwahlen, Lim K. Cheung

    Background. We aim to illustrate the applications of 3‐dimensional (3‐D) photogrammetry for surgical planning and longitudinal assessment of the volumetric changes in hemifacial microsomia. Methods. A 3‐D photogrammetric system was employed for planning soft tissue expansion and transplantation of a vascularized scapular flap for a patient with hemifacial microsomia. The facial deficiency was calculated by superimposing a mirror of the normal side on the preoperative image. Postsurgical volumetric changes were monitored by serial superimposition of 3‐D images. Results. A total of 31 cm3 of tissue expansion was achieved within a period of 4 weeks. A scapular free flap measuring 8 cm × 5 cm was transplanted to augment the facial deficiency. Postsurgical shrinkage of the flap was observed mainly in the first 3 months and it was minimal thereafter. Conclusion. 3‐D photogrammetry can be used as a noninvasive objective tool for assessing facial deformity, planning, and postoperative follow‐up of surgical correction of facial asymmetry. © 2009 Wiley Periodicals, Inc. Head Neck, 2010


  • Three-Dimensional Color Maps: A Novel Tool for Assessing Craniofacial Changes

    by Yasas S. N. Jayaratne, Roger A. Zwahlen, John Lo, Lim K. Cheung

    Introduction. Three-dimensional (3D) color maps are useful for analyzing data acquired by laser scanning, stereophotography, or computed tomography (CT). The authors aim to illustrate the different applications of color maps in the craniomaxillofacial region. Methods. The images obtained from the above techniques at 2 different time points are superimposed based on a common area unaffected by the surgical intervention or growth. Using specialized software, the distance differences between the 2 superimposed images are depicted in a graphical format as a 3D color map. A color-coded scale indicating the distances accompanies these maps. Results. 3D color maps can be manipulated and viewed in a variety of angles to extract the maximum diagnostic information. They facilitate the critical evaluation of facial asymmetry, accuracy of fusing CT and 3D photo data sets, and postsurgical changes. Conclusion. 3D color maps aid the objective assessment of craniofacial structures while enhancing visual comprehension and communication with patients.


    • 1 March 2010
      • Vol. 20, 93-4

    Coronectomy as the treatment of choice in wisdom teeth showing radiographic signs of close proximity to inferior dental nerve.

    by Yiu Yan Leung, Lim Kwong Cheung

    The aim of the study is to compare the prevalence of post-operative inferior dental nerve (IDN) deficit after coronectomy with total removal of wisdom teeth showing specific radiographic signs of close proximity to IDN. A randomized clinical trial comparing total removal and coronectomy of wisdom tooth was conducted. Analyses of the correlations of IDN deficit and various radiographic signs of wisdom tooth roots showing close proximity to IDN were performed. Two radiographic signs were found to be positive predictors ofintra-operative IDN exposure. Specific radiographic signs or the presence of two or more radiographic signs are positive predictors of post-operative IDN deficit. The study concluded that darkening of the wisdom tooth root and presence of two or more specific signs in radiographs significantly increased the risk of IDN deficit in lower wisdom tooth surgery. Coronectomy can significantly reduce the prevalence of an IDN deficit in patients with lower wisdom teeth showing radiographic signs of close proximity to IDN. It also carries less surgical morbidities when compared with total removal of lower wisdom tooth.


    • 1 June 2008
      • Vol. 19, 50-1

    Can coronectomy of wisdom teeth reduce the incidence of inferior dental nerve injury?

    by Yiu Yan Leung, Lim Kwong Cheung

    The aim of the study was to compare the surgical complications and neurosensory disturbance of coronectomy and conventional excision of lower third molars with roots in close proximity to inferior dental nerve. We conducted a randomized clinical trial of patients with lower third molars showing specific radiographic signs was conducted. Patients were randomized to undergo either coronectomy or total excision (control) of the lower third molar. It was concluded that coronectomy can significantly reduce the incidence of inferior dental nerve deficit when compared with conventional excision when the roots show radiographic signs of close proximity, and the technique showed a similar rate of other surgical morbidities.