Paul Struszewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Paul Struszewski has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Mark Bieler
Physikalisch-Technische Bundesanstalt
8 shared publications - Alessia Pasquazi
Loughborough University
1 shared publication B Güttler
Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Germany
1 shared publicationB Liu
TU Braunschweig, Institut für Physik der Kondensierten Materie, Mendelssohnstr. 3, D-38106 Braunschweig, Germany
1 shared publication- Benedikt Hampel
National Institute of Standards and Technology 1 , Boulder, Colorado 80305
1 shared publication - David A. Humphreys
National Physical Laboratory, Teddington, UK
1 shared publication
Latest Publications
- 12 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (6) , 2295-2302
Asynchronous Optical Sampling for Laser-Based Vector Network Analysis on Coplanar Waveguides
- 12 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (6) , 2295-2302
Asynchronous Optical Sampling for Laser-Based Vector Network Analysis on Coplanar Waveguides
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
All-optical vector network analyzer with 500 GHz bandwidth and 76 MHz frequency resolution
We demonstrate an all-optical time-domain vector network analyzer with a frequency resolution of 76 MHz and a bandwidth exceeding 500 GHz in a single measurement configuration. Electrical reflection coefficients are obtained from measurements of ultra-short voltage pulses at different positions on a coplanar waveguide using femtosecond laser pulses and an asynchronous optical sampling technique. In contrast to our previous synchronous sampling experiments, the new technique leads to a significant improvement of the frequency resolution and potentially more accurate measurements being important for future calibration tasks.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
All-optical vector network analyzer with 500 GHz bandwidth and 76 MHz frequency resolution
We demonstrate an all-optical time-domain vector network analyzer with a frequency resolution of 76 MHz and a bandwidth exceeding 500 GHz in a single measurement configuration. Electrical reflection coefficients are obtained from measurements of ultra-short voltage pulses at different positions on a coplanar waveguide using femtosecond laser pulses and an asynchronous optical sampling technique. In contrast to our previous synchronous sampling experiments, the new technique leads to a significant improvement of the frequency resolution and potentially more accurate measurements being important for future calibration tasks.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of a Portable Femtosecond-Laser-Driven Ultrashort Voltage Pulse Standard with a Footprint of 25 × 30 cm2
We describe the development of a portable laser-based voltage pulse standard for the V and W band providing a pulse width of a few picoseconds and frequency components significantly exceeding 100 GHz. The device has a very small footprint and allows easy handling. It is based on femtosecond laser technology and ultrafast photodiodes, both of which are commercially available. Realization of the device is accomplished in two steps: (i) characterization of ultrafast photodiodes in a stationary system using femtosecond electro-optic sampling techniques and (ii) integration of the characterized photodiodes into a small box together with a small femtosecond laser module. Such portable standards are ideal devices for waveform metrology and calibration tasks at both, national metrology institutes and industry.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Development of a Portable Femtosecond-Laser-Driven Ultrashort Voltage Pulse Standard with a Footprint of 25 × 30 cm2
We describe the development of a portable laser-based voltage pulse standard for the V and W band providing a pulse width of a few picoseconds and frequency components significantly exceeding 100 GHz. The device has a very small footprint and allows easy handling. It is based on femtosecond laser technology and ultrafast photodiodes, both of which are commercially available. Realization of the device is accomplished in two steps: (i) characterization of ultrafast photodiodes in a stationary system using femtosecond electro-optic sampling techniques and (ii) integration of the characterized photodiodes into a small box together with a small femtosecond laser module. Such portable standards are ideal devices for waveform metrology and calibration tasks at both, national metrology institutes and industry.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Asynchronous Optical Sampling for Laser-Based Vector Network Analysis on Coplanar Waveguides
We employ asynchronous optical sampling to realize a laser-based vector network analyzer. This time-domain approach utilizes two separate femtosecond lasers for the generation and detection of ultrashort voltage pulses on a waveguide structure and does not require any optical delay lines. The new scheme allows us to increase the measurement epoch, enabling a frequency resolution of 76 MHz while simultaneously covering a broad frequency range up to approximately 500 GHz.
- 1 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Asynchronous Optical Sampling for Laser-Based Vector Network Analysis on Coplanar Waveguides
We employ asynchronous optical sampling to realize a laser-based vector network analyzer. This time-domain approach utilizes two separate femtosecond lasers for the generation and detection of ultrashort voltage pulses on a waveguide structure and does not require any optical delay lines. The new scheme allows us to increase the measurement epoch, enabling a frequency resolution of 76 MHz while simultaneously covering a broad frequency range up to approximately 500 GHz.
- Open Access
- 14 February 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (3) , 035003
Approach to determine measurement uncertainty in complex nanosystems with multiparametric dependencies and multivariate output quantities
In many cases, the determination of the measurement uncertainty of complex nanosystems provides unexpected challenges. This is in particular true for complex systems with many degrees of freedom, i.e. nanosystems with multiparametric dependencies and multivariate output quantities. The aim of this paper is to address specific questions arising during the uncertainty calculation of such systems. This includes the division of the measurement system into subsystems and the distinction between systematic and statistical influences. We demonstrate that, even if the physical systems under investigation are very different, the corresponding uncertainty calculation can always be realized in a similar manner. This is exemplarily shown in detail for two experiments, namely magnetic nanosensors and ultrafast electro-optical sampling of complex time-domain signals. For these examples the approach for uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) is explained, in which correlations between multivariate output quantities are captured. To illustate the versatility of the proposed approach, its application to other experiments, namely nanometrological instruments for terahertz microscopy, dimensional scanning probe microscopy, and measurement of concentration of molecules using surface enhanced Raman scattering, is shortly discussed in the appendix. We believe that the proposed approach provides a simple but comprehensive orientation for uncertainty calculation in the discussed measurement scenarios and can also be applied to similar or related situations.
- 14 February 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (3) , 035003
Open AccessApproach to determine measurement uncertainty in complex nanosystems with multiparametric dependencies and multivariate output quantities
In many cases, the determination of the measurement uncertainty of complex nanosystems provides unexpected challenges. This is in particular true for complex systems with many degrees of freedom, i.e. nanosystems with multiparametric dependencies and multivariate output quantities. The aim of this paper is to address specific questions arising during the uncertainty calculation of such systems. This includes the division of the measurement system into subsystems and the distinction between systematic and statistical influences. We demonstrate that, even if the physical systems under investigation are very different, the corresponding uncertainty calculation can always be realized in a similar manner. This is exemplarily shown in detail for two experiments, namely magnetic nanosensors and ultrafast electro-optical sampling of complex time-domain signals. For these examples the approach for uncertainty calculation following the guide to the expression of uncertainty in measurement (GUM) is explained, in which correlations between multivariate output quantities are captured. To illustate the versatility of the proposed approach, its application to other experiments, namely nanometrological instruments for terahertz microscopy, dimensional scanning probe microscopy, and measurement of concentration of molecules using surface enhanced Raman scattering, is shortly discussed in the appendix. We believe that the proposed approach provides a simple but comprehensive orientation for uncertainty calculation in the discussed measurement scenarios and can also be applied to similar or related situations.
- 15 September 2017
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 38 (11) , 1416-1431
Time-Domain Characterization of High-Speed Photodetectors
- 15 September 2017
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 38 (11) , 1416-1431
Time-Domain Characterization of High-Speed Photodetectors
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The laser-based vector network analyzer project at PTB
- 1 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
The laser-based vector network analyzer project at PTB
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-196
Optical and RF metrology for 5G
Specification standards will soon be available for 5G mobile RF communications. What optical and electrical metrology is needed or available to support the development of the supporting optical communication systems? Device measurement, digital oscilloscope impairments and improving system resolution are discussed.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 195-196
Optical and RF metrology for 5G
Specification standards will soon be available for 5G mobile RF communications. What optical and electrical metrology is needed or available to support the development of the supporting optical communication systems? Device measurement, digital oscilloscope impairments and improving system resolution are discussed.
- 26 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (6) , 1613-1620
Characterization of High-Speed Balanced Photodetectors
We report the characterization of a balanced ultrafast photodetector. For this purpose, we use a recently developed time-domain laser-based vector network analyzer (VNA) to determine the common-mode rejection ratio (CMRR) of the device under test. This includes the frequency-domain response above the single-mode frequency of the coaxial connector. Although the balanced photodetector has a nominal bandwidth of 43 GHz, it generates voltage pulses with frequency components up to 180 GHz. We obtain a CMRR of better than 30 dB up to 70 GHz and better than 20 dB up to 110 GHz. The laser-based measurements are compared with the measurements using a digital sampling oscilloscope and with the frequency-domain measurements using a conventional VNA. We obtain good agreement between the three techniques with the laser-based method providing the largest measurement bandwidth, although it also constitutes the most complicated characterization setup.
- 26 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 66 (6) , 1613-1620
Characterization of High-Speed Balanced Photodetectors
We report the characterization of a balanced ultrafast photodetector. For this purpose, we use a recently developed time-domain laser-based vector network analyzer (VNA) to determine the common-mode rejection ratio (CMRR) of the device under test. This includes the frequency-domain response above the single-mode frequency of the coaxial connector. Although the balanced photodetector has a nominal bandwidth of 43 GHz, it generates voltage pulses with frequency components up to 180 GHz. We obtain a CMRR of better than 30 dB up to 70 GHz and better than 20 dB up to 110 GHz. The laser-based measurements are compared with the measurements using a digital sampling oscilloscope and with the frequency-domain measurements using a conventional VNA. We obtain good agreement between the three techniques with the laser-based method providing the largest measurement bandwidth, although it also constitutes the most complicated characterization setup.
- 11 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Characterization of high-speed photodetectors using a laser-based vector network analyzer
We report the characterization of single and balanced ultrafast photodetectors. For this purpose we use a recently developed laser-based vector network analyzer, but no other measurement instrumentation. Our analysis includes full mismatch correction and takes into account the frequency-domain responses above the single-mode frequency of the coaxial connectors. We show that such measurements are essential if the time-domain response of the photodetectors has to be specified.
- 11 August 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Characterization of high-speed photodetectors using a laser-based vector network analyzer
We report the characterization of single and balanced ultrafast photodetectors. For this purpose we use a recently developed laser-based vector network analyzer, but no other measurement instrumentation. Our analysis includes full mismatch correction and takes into account the frequency-domain responses above the single-mode frequency of the coaxial connectors. We show that such measurements are essential if the time-domain response of the photodetectors has to be specified.