Shau Poh Chong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shau Poh Chong has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Vivek Jay Srinivasan
NYU Langone Health
10 shared publications - Conrad William Merkle
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090 Vienna, Vienna, Austria
8 shared publications Nanguang Chen
National Univ. of Singapore (Singapore)
8 shared publicationsHarsha Radhakrishnan
Univ. of California, Davis (United States)
6 shared publicationsChee Howe Wong
Division of Bioengineering, National University of Singapore, 7 Engineering Drive, Singapore 117576
5 shared publications- Colin James Richard Sheppard
School of Optometry and Vision Science, UNSW Medicine, Sydney, NSW 2052, Australia
5 shared publications
Latest Publications
- 15 April 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (5) , 2442-2466
Ultrabroadband OCT for simultaneous visible and near-infrared light imaging of the mouse retina
Hyperspectral optical coherence tomographic imaging of the retina using the visible-near-infrared wavelength range improves the use of spectroscopic information for biomarkers of retinal diseases without compromising the achievable axial resolution. Previous efforts to develop an optical coherence tomograph that covers both visible and near-infrared wavelengths were hampered by the challenges in designing a broadband spectrometer with adequate performance. In this work, we describe an ultrabroadband OCT system we designed that advances the state-of-the art in two major aspects: the design and implementation of a broadband spectrometer employing a 4k-pixel line camera achieving a spectral range of greater than 450nm with a central wavelength of 680nm; and an achromatised imaging system that minimises aberrations in the visible-near-infrared wavelength range for imaging mouse retina. The system provides an axial imaging range greater than 0.67mm within the retina with a larger than 40 ∘ field angle. With this, we demonstrated ultrabroadband mouse retinal structural imaging in vivo and simultaneous visible and NIR waveband visualization of axon fiber bundle within the retinal nerve fiber layer for the first time. Our system opens new avenues for enhanced functional imaging of the mouse retina.
- 15 April 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (5) , 2442-2466
Ultrabroadband OCT for simultaneous visible and near-infrared light imaging of the mouse retina
Hyperspectral optical coherence tomographic imaging of the retina using the visible-near-infrared wavelength range improves the use of spectroscopic information for biomarkers of retinal diseases without compromising the achievable axial resolution. Previous efforts to develop an optical coherence tomograph that covers both visible and near-infrared wavelengths were hampered by the challenges in designing a broadband spectrometer with adequate performance. In this work, we describe an ultrabroadband OCT system we designed that advances the state-of-the art in two major aspects: the design and implementation of a broadband spectrometer employing a 4k-pixel line camera achieving a spectral range of greater than 450nm with a central wavelength of 680nm; and an achromatised imaging system that minimises aberrations in the visible-near-infrared wavelength range for imaging mouse retina. The system provides an axial imaging range greater than 0.67mm within the retina with a larger than 40 ∘ field angle. With this, we demonstrated ultrabroadband mouse retinal structural imaging in vivo and simultaneous visible and NIR waveband visualization of axon fiber bundle within the retinal nerve fiber layer for the first time. Our system opens new avenues for enhanced functional imaging of the mouse retina.
- 21 March 2024
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (4) , 552-564
Influence of laser pulse shape and cleanliness on two-photon microscopy
Nonlinear microscopy, including two-photon microscopy, requires pulsed lasers as light source. Typically, when choosing the appropriate pulsed laser for two-photon microscopy, the pulse repetition rate, pulse width, total power output, and output beam diameter are among the critical parameters which are often emphasised. Here, we demonstrate that the pulse shape, often overlooked, can have significant impact on the two-photon microscopy excitation efficiency and the effective signal brightness. We provide metrics to ease practical selection of pulsed laser sources for two-photon microscopy.
- 21 March 2024
- Published by Optica Publishing Group in Optics Continuum
- Vol. 3 (4) , 552-564
Influence of laser pulse shape and cleanliness on two-photon microscopy
Nonlinear microscopy, including two-photon microscopy, requires pulsed lasers as light source. Typically, when choosing the appropriate pulsed laser for two-photon microscopy, the pulse repetition rate, pulse width, total power output, and output beam diameter are among the critical parameters which are often emphasised. Here, we demonstrate that the pulse shape, often overlooked, can have significant impact on the two-photon microscopy excitation efficiency and the effective signal brightness. We provide metrics to ease practical selection of pulsed laser sources for two-photon microscopy.
- Open Access
- 13 June 2023
- Published by Springer Nature in Research Square
The influence of laser pulse shape and cleanliness on two-photon microscopy
Nonlinear microscopy, including two-photon microscopy, requires pulsed lasers as light source. Typically, when choosing the appropriate pulsed laser for two-photon microscopy, the pulse repetition rate, pulse width, total power output, and output beam diameter are among the critical parameters which are often emphasised. Here, we demonstrate that the pulse shape, often overlooked, can have significant impact on the two-photon microscopy excitation efficiency and the effective signal brightness. We provide metrics to ease practical selection of pulsed laser sources for two-photon microscopy.
- 13 June 2023
- Published by Springer Nature in Research Square
Open AccessThe influence of laser pulse shape and cleanliness on two-photon microscopy
Nonlinear microscopy, including two-photon microscopy, requires pulsed lasers as light source. Typically, when choosing the appropriate pulsed laser for two-photon microscopy, the pulse repetition rate, pulse width, total power output, and output beam diameter are among the critical parameters which are often emphasised. Here, we demonstrate that the pulse shape, often overlooked, can have significant impact on the two-photon microscopy excitation efficiency and the effective signal brightness. We provide metrics to ease practical selection of pulsed laser sources for two-photon microscopy.
- 13 March 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (4) , 2007-2016
Multifunctional laser speckle imaging
We have developed a multi-functional laser speckle imaging system, which can be operated in both the surface illumination laser speckle contrast imaging (SI-LSCI) mode and the line scan laser speckle contrast imaging (LS-LSCI) mode. The system has been applied to imaging the chicken embryos to visualize both the blood flow and morphological details of the vasculature. The experimental results demonstrated that LS-LSCI is capable of detecting and quantifying blood flow in blood vessels smaller and deeper than those detectable by conventional SI-LSCI. Furthermore, the line scan mode is also capable of producing depth-resolved absorption-based morphological images of tissue, augmenting flow-based functional images.
- 13 March 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (4) , 2007-2016
Multifunctional laser speckle imaging
We have developed a multi-functional laser speckle imaging system, which can be operated in both the surface illumination laser speckle contrast imaging (SI-LSCI) mode and the line scan laser speckle contrast imaging (LS-LSCI) mode. The system has been applied to imaging the chicken embryos to visualize both the blood flow and morphological details of the vasculature. The experimental results demonstrated that LS-LSCI is capable of detecting and quantifying blood flow in blood vessels smaller and deeper than those detectable by conventional SI-LSCI. Furthermore, the line scan mode is also capable of producing depth-resolved absorption-based morphological images of tissue, augmenting flow-based functional images.
- 19 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11211, 1121109
Visible light optical coherence microscopy for quantitative imaging of human skin in vivo
Recent development of visible light Optical Coherence Microscopy (i.e. Optical Coherence Tomography employing high numerical aperture Objective) has pushed the axial/transverse resolution limit to < 2 μm within tissues. Here, a fiber-based visible light Fourier domain (FD) Optical Coherence Microscopy system is presented, employing a 10x water immersion objective to achieve higher transverse resolution and reduced specular reflection when imaging human skin in vivo, using ~ 1-2 mW of incident power. Though with limited penetration depth, we demonstrated its application for in vivo imaging of human skin, and further measured the thicknesses of epidermis and dermo-epidermal junction. Furthermore, the total attenuation coefficient of the skin tissues was also estimated across epidermis and dermis.
- 19 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11211, 1121109
Visible light optical coherence microscopy for quantitative imaging of human skin in vivo
Recent development of visible light Optical Coherence Microscopy (i.e. Optical Coherence Tomography employing high numerical aperture Objective) has pushed the axial/transverse resolution limit to < 2 μm within tissues. Here, a fiber-based visible light Fourier domain (FD) Optical Coherence Microscopy system is presented, employing a 10x water immersion objective to achieve higher transverse resolution and reduced specular reflection when imaging human skin in vivo, using ~ 1-2 mW of incident power. Though with limited penetration depth, we demonstrated its application for in vivo imaging of human skin, and further measured the thicknesses of epidermis and dermo-epidermal junction. Furthermore, the total attenuation coefficient of the skin tissues was also estimated across epidermis and dermis.
- 1 September 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (17) , 4147-4150
Noninvasive, in vivo rodent brain optical coherence tomography at 21 microns
In biological tissue, longer near-infrared wavelengths generally experience less scattering and more water absorption. Here we demonstrate an optical coherence tomography (OCT) system centered at 2.1 microns, whose bandwidth falls in the 2.2 micron water absorption optical window, for in vivo imaging of the rodent brain. We show in vivo that at 2.1 microns, the OCT signal is actually attenuated less in cranial bone than at 1.3 microns, and is also less susceptible to multiple scattering tails. We also show that the 2.2 micron window enables direct spectroscopic OCT assessment of tissue water content. We conclude that with further optimization, 2.2 micron OCT will have advantages in low-water-content tissue such as bone, as well as applications where extensive averaging is possible to compensate absorption losses.
- 1 September 2019
- Published by Optica Publishing Group in Optics Letters
- Vol. 44 (17) , 4147-4150
Noninvasive, in vivo rodent brain optical coherence tomography at 21 microns
In biological tissue, longer near-infrared wavelengths generally experience less scattering and more water absorption. Here we demonstrate an optical coherence tomography (OCT) system centered at 2.1 microns, whose bandwidth falls in the 2.2 micron water absorption optical window, for in vivo imaging of the rodent brain. We show in vivo that at 2.1 microns, the OCT signal is actually attenuated less in cranial bone than at 1.3 microns, and is also less susceptible to multiple scattering tails. We also show that the 2.2 micron window enables direct spectroscopic OCT assessment of tissue water content. We conclude that with further optimization, 2.2 micron OCT will have advantages in low-water-content tissue such as bone, as well as applications where extensive averaging is possible to compensate absorption losses.
- Open Access
- 30 April 2018
- Published by Optica Publishing Group in Optica
- Vol. 5 (5) , 518-527
Highly parallel, interferometric diffusing wave spectroscopy for monitoring cerebral blood flow dynamics
Light-scattering methods are widely used in soft matter physics and biomedical optics to probe dynamics in turbid media, such as diffusion in colloids or blood flow in biological tissue. These methods typically rely on fluctuations of coherent light intensity, and therefore cannot accommodate more than a few modes per detector. This limitation has hindered efforts to measure deep tissue blood flow with high speed, since weak diffuse light fluxes, together with low single-mode fiber throughput, result in low photon count rates. To solve this, we introduce multimode fiber (MMF) interferometry to the field of diffuse optics. In doing so, we transform a standard complementary metal-oxide-semiconductor (CMOS) camera into a sensitive detector array for weak light fluxes that probe deep in biological tissue. Specifically, we build a novel CMOS-based, multimode interferometric diffusing wave spectroscopy (iDWS) system and show that it can measure speckles simultaneously near the shot noise limit, acting essentially as independent photon-counting channels. We develop a matrix formalism, based on MMF mode field solutions and detector geometry, to predict both coherence and speckle number in iDWS. After validation in liquid phantoms, we demonstrate iDWS pulsatile blood flow measurements at 2.5 cm source-detector separation in the adult human brain in vivo. By achieving highly sensitive and parallel measurements of coherent light fluctuations with a CMOS camera, this work promises to enhance performance and reduce cost of diffuse optical instruments.- 30 April 2018
- Published by Optica Publishing Group in Optica
- Vol. 5 (5) , 518-527
Open AccessHighly parallel, interferometric diffusing wave spectroscopy for monitoring cerebral blood flow dynamics
Light-scattering methods are widely used in soft matter physics and biomedical optics to probe dynamics in turbid media, such as diffusion in colloids or blood flow in biological tissue. These methods typically rely on fluctuations of coherent light intensity, and therefore cannot accommodate more than a few modes per detector. This limitation has hindered efforts to measure deep tissue blood flow with high speed, since weak diffuse light fluxes, together with low single-mode fiber throughput, result in low photon count rates. To solve this, we introduce multimode fiber (MMF) interferometry to the field of diffuse optics. In doing so, we transform a standard complementary metal-oxide-semiconductor (CMOS) camera into a sensitive detector array for weak light fluxes that probe deep in biological tissue. Specifically, we build a novel CMOS-based, multimode interferometric diffusing wave spectroscopy (iDWS) system and show that it can measure speckles simultaneously near the shot noise limit, acting essentially as independent photon-counting channels. We develop a matrix formalism, based on MMF mode field solutions and detector geometry, to predict both coherence and speckle number in iDWS. After validation in liquid phantoms, we demonstrate iDWS pulsatile blood flow measurements at 2.5 cm source-detector separation in the adult human brain in vivo. By achieving highly sensitive and parallel measurements of coherent light fluctuations with a CMOS camera, this work promises to enhance performance and reduce cost of diffuse optical instruments. - 3 April 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10483, 104831X
Visible light optical coherence microscopy imaging of the mouse cortex with femtoliter volume resolution
Most flying-spot Optical Coherence Tomography (OCT) and Optical Coherence Microscopy (OCM) systems use a symmetric confocal geometry, where the detection path retraces the illumination path starting from and ending with the spatial mode of a single mode optical fiber. Here, we describe a visible light OCM instrument that breaks this symmetry to improve transverse resolution without sacrificing collection efficiency in scattering tissue. This was achieved by overfilling a 0.3 numerical aperture (NA) water immersion objective on the illumination path, while maintaining a conventional Gaussian mode detection path (1/e2 intensity diameter ~0.82 Airy disks), enabling ~1.1 μm full-width at half-maximum (FWHM) transverse resolution. At the same time, a ~0.9 μm FWHM axial resolution in tissue, achieved by a broadband visible light source, enabled femtoliter volume resolution. We characterized this instrument according to paraxial coherent microscopy theory, and then used it to image the meningeal layers, intravascular red blood cell-free layer, and myelinated axons in the mouse neocortex in vivo through the thinned skull. Finally, by introducing a 0.8 NA water immersion objective, we improved the lateral resolution to 0.44 μm FWHM, which provided a volumetric resolution of ~0.2 fL, revealing cell bodies in cortical layer I of the mouse brain with OCM for the first time.
- 3 April 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10483, 104831X
Visible light optical coherence microscopy imaging of the mouse cortex with femtoliter volume resolution
Most flying-spot Optical Coherence Tomography (OCT) and Optical Coherence Microscopy (OCM) systems use a symmetric confocal geometry, where the detection path retraces the illumination path starting from and ending with the spatial mode of a single mode optical fiber. Here, we describe a visible light OCM instrument that breaks this symmetry to improve transverse resolution without sacrificing collection efficiency in scattering tissue. This was achieved by overfilling a 0.3 numerical aperture (NA) water immersion objective on the illumination path, while maintaining a conventional Gaussian mode detection path (1/e2 intensity diameter ~0.82 Airy disks), enabling ~1.1 μm full-width at half-maximum (FWHM) transverse resolution. At the same time, a ~0.9 μm FWHM axial resolution in tissue, achieved by a broadband visible light source, enabled femtoliter volume resolution. We characterized this instrument according to paraxial coherent microscopy theory, and then used it to image the meningeal layers, intravascular red blood cell-free layer, and myelinated axons in the mouse neocortex in vivo through the thinned skull. Finally, by introducing a 0.8 NA water immersion objective, we improved the lateral resolution to 0.44 μm FWHM, which provided a volumetric resolution of ~0.2 fL, revealing cell bodies in cortical layer I of the mouse brain with OCM for the first time.
- Open Access
- 5 March 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (4) , 1477-1491
Ultrahigh resolution retinal imaging by visible light OCT with longitudinal achromatization
Chromatic aberrations are an important design consideration in high resolution, high bandwidth, refractive imaging systems that use visible light. Here, we present a fiber-based spectral/Fourier domain, visible light OCT ophthalmoscope corrected for the average longitudinal chromatic aberration (LCA) of the human eye. Analysis of complex speckles from in vivo retinal images showed that achromatization resulted in a speckle autocorrelation function that was ~20% narrower in the axial direction, but unchanged in the transverse direction. In images from the improved, achromatized system, the separation between Bruch’s membrane (BM), the retinal pigment epithelium (RPE), and the outer segment tips clearly emerged across the entire 6.5 mm field-of-view, enabling segmentation and morphometry of BM and the RPE in a human subject. Finally, cross-sectional images depicted distinct inner retinal layers with high resolution. Thus, with chromatic aberration compensation, visible light OCT can achieve volume resolutions and retinal image quality that matches or exceeds ultrahigh resolution near-infrared OCT systems with no monochromatic aberration compensation.
- 5 March 2018
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 9 (4) , 1477-1491
Open AccessUltrahigh resolution retinal imaging by visible light OCT with longitudinal achromatization
Chromatic aberrations are an important design consideration in high resolution, high bandwidth, refractive imaging systems that use visible light. Here, we present a fiber-based spectral/Fourier domain, visible light OCT ophthalmoscope corrected for the average longitudinal chromatic aberration (LCA) of the human eye. Analysis of complex speckles from in vivo retinal images showed that achromatization resulted in a speckle autocorrelation function that was ~20% narrower in the axial direction, but unchanged in the transverse direction. In images from the improved, achromatized system, the separation between Bruch’s membrane (BM), the retinal pigment epithelium (RPE), and the outer segment tips clearly emerged across the entire 6.5 mm field-of-view, enabling segmentation and morphometry of BM and the RPE in a human subject. Finally, cross-sectional images depicted distinct inner retinal layers with high resolution. Thus, with chromatic aberration compensation, visible light OCT can achieve volume resolutions and retinal image quality that matches or exceeds ultrahigh resolution near-infrared OCT systems with no monochromatic aberration compensation.
- 3 January 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (2) , 198-201
Visible light optical coherence microscopy of the brain with isotropic femtoliter resolution in vivo
Most flying-spot optical coherence tomography and optical coherence microscopy (OCM) systems use a symmetric confocal geometry, where the detection path retraces the illumination path starting from and ending with the spatial mode of a single-mode optical fiber. Here we describe a visible light OCM instrument that breaks this symmetry to improve transverse resolution without sacrificing collection efficiency in scattering tissue. This was achieved by overfilling a water immersion objective on the illumination path while maintaining a conventional Gaussian mode detection path ( intensity diameter Airy disks), enabling full width at half-maximum (FWHM) transverse resolution. At the same time, a FWHM axial resolution in tissue, achieved by a broadband visible light source, enabled femtoliter volume resolution. We characterized this instrument according to paraxial coherent microscopy theory and, finally, used it to image the meningeal layers, intravascular red blood cell-free layer, and myelinated axons in the mouse neocortex in vivo through the thinned skull.- 3 January 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (2) , 198-201
Visible light optical coherence microscopy of the brain with isotropic femtoliter resolution in vivo
Most flying-spot optical coherence tomography and optical coherence microscopy (OCM) systems use a symmetric confocal geometry, where the detection path retraces the illumination path starting from and ending with the spatial mode of a single-mode optical fiber. Here we describe a visible light OCM instrument that breaks this symmetry to improve transverse resolution without sacrificing collection efficiency in scattering tissue. This was achieved by overfilling a water immersion objective on the illumination path while maintaining a conventional Gaussian mode detection path ( intensity diameter Airy disks), enabling full width at half-maximum (FWHM) transverse resolution. At the same time, a FWHM axial resolution in tissue, achieved by a broadband visible light source, enabled femtoliter volume resolution. We characterized this instrument according to paraxial coherent microscopy theory and, finally, used it to image the meningeal layers, intravascular red blood cell-free layer, and myelinated axons in the mouse neocortex in vivo through the thinned skull.