NSNiklas Schofer

Niklas Schofer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Niklas Schofer has a total of 325 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Katheterbasierte Therapie der Trikuspidalklappeninsuffizienz – wann Rekonstruktion, wann Prothese?

    by Niklas Schofer

    Zusammenfassung: Die höhergradige Trikuspidalklappeninsuffizienz (TI) ist mit erhöhter Morbidität, Letalität und eingeschränkter Lebensqualität assoziiert. Mit der Einführung katheterbasierter Therapien stehen heute wirksame Behandlungsoptionen für Patientinnen und Patienten mit hohem Operationsrisiko zur Verfügung. Die trikuspidale Transkatheter-Edge-to-Edge-Reparatur (T-TEER) zeichnet sich durch ein hohes Maß an Sicherheit aus und verbessert Lebensqualität sowie Herzinsuffizienzhospitalisationen, ihre Effektivität ist jedoch von der Klappenanatomie abhängig. Der katheterbasierte Trikuspidalklappenersatz (Transcatheter Tricuspid Valve Replacement [TTVR]) ermöglicht häufiger eine nahezu vollständige Beseitigung der Insuffizienz, geht jedoch mit spezifischen Risiken wie Reizleitungsstörungen, Blutungen und der Notwendigkeit einer dauerhaften Antikoagulation einher. Die Wahl des geeigneten Verfahrens basiert derzeit auf anatomischen und klinischen Kriterien und sollte durch ein erfahrenes interdisziplinäres Heart Team erfolgen.

  • Pulmonary Artery Systolic Pressure Trajectories After Transcatheter Edge-to-Edge Repair in Atrial and Ventricular Secondary Mitral Regurgitation

    by Philipp von Stein, Jörg Hausleiter, Patrick Horn, Mirjam Kessler, Volker Rudolph, Bernhard Unsöld, Philipp Lurz, Marcel Weber, Niklas Schofer, Mathias H. Konstandin, et al.


  • Relation of Residual Mitral Regurgitation and Gradient Following Mitral Valve Transcatheter Edge-to-Edge Repair

    by Donika Mustafa, Jennifer von Stein, Lukas Stolz, Jean Marc Haurand, Matthias Gröger, Felix Rudolph, Jannik Jobst, Christoph Alexander Mues, Amir Abbas Mahabadi, Isabel A. Hoerbrand, et al.

    BACKGROUND: Residual mitral regurgitation (rMR) ≤1+ has been associated with improved 1-year outcomes after mitral valve transcatheter edge-to-edge repair, regardless of the mean mitral pressure gradient (MPG). Prior evidence is limited to 30-day echocardiographic follow-up and patients treated with the MitraClip (Abbott Structural Heart). Whether rMR and MPG assessed at discharge are associated with outcomes after PASCAL mitral valve transcatheter edge-to-edge repair (Edwards Lifesciences) remains unknown. METHODS: REPAIR (Registry of Pascal for Mitral Regurgitation) is an investigator-initiated, multicenter registry including all consecutive patients treated with PASCAL mitral valve transcatheter edge-to-edge repair. Based on discharge echocardiography, patients were stratified into 4 groups: optimal (rMR ≤1+, MPG P P Bonferroni P <0.001) and remained significant, independent of dichotomized (MPG, 0.450). CONCLUSIONS: Discharge rMR ≤1+ is independently associated with lower 1-year mortality after PASCAL mitral valve transcatheter edge-to-edge repair. Although MPG was not independently associated, modestly elevated gradients may be acceptable when rMR ≤1+ is achieved, but should still warrant clinical attention. REGISTRATION: URL: https://www.drks.de ; Unique identifier: DRKS00033959.


  • Open Access

    Mitral repair on the edge: a case report of redo transcatheter mitral edge-to-edge repair for recurrent regurgitation in Complex lateral jet anatomy

    by Christoph Pauschinger, Benedikt Koell, Lara Waldschmidt, Niklas Schofer, Daniel Kalbacher

    Background: Degenerative mitral regurgitation (DMR) is associated with substantial morbidity and mortality if left untreated. While surgical repair remains the gold standard, mitral transcatheter edge-to-edge repair (M-TEER) is an established alternative for patients at high surgical risk. However, recurrent MR after initial M-TEER remains a therapeutic challenge and is associated with poor outcomes. Case summary: A 77-year-old patient presented with recurrent heart failure symptoms due to MR after prior CARILLON® device implantation for secondary MR at an external hospital in September 2019. Transoesophageal echocardiography revealed degenerative mitral valve disease characterized by a complex combination of posterior leaflet prolapse and anterior leaflet flail, resulting in a severe eccentric regurgitant jet. The patient underwent successful M-TEER with the MitraClip® system in December 2021. In June 2023, the patient was re-hospitalized for recurrent heart failure symptoms. Imaging revealed severe recurrent MR originating lateral to the implanted device. A redo M-TEER was performed using the PASCAL® system, requiring careful navigation through a narrow residual lateral orifice. The procedure resulted in a durable reduction to mild MR with sustained clinical stability at 18-month follow-up. Discussion: This case illustrates the anatomical challenges of DMR and demonstrates the feasibility and durability of redo M-TEER in high surgical risk patients with recurrent MR. It emphasizes the importance of individualized anatomical assessment and tailored device selection in complex valve anatomies.

  • Transcatheter Aortic Valve Replacement With Balloon- Versus Self-Expandable Bioprostheses for the Treatment of Bicuspid Aortic Valve Stenosis

    by Daniele Giacoppo, Hector A. Alvarez-Covarrubias, Erion Xhepa, Yuji Matsuda, Stefano Cangemi, Jonathan M. Michel, Anna Sannino, Johannes Ziegelmüller, Enrico Criscione, Motoki Fukutomi, et al.

    BACKGROUND: Differences between balloon- and self-expandable transcatheter heart valves (BE-THVs and SE-THVs, respectively) may influence the outcomes of transcatheter aortic valve replacement for bicuspid aortic valve (BAV) stenosis. METHODS: Consecutive patients undergoing transcatheter aortic valve replacement with BE-THV or SE-THV for computed tomography–diagnosed bicuspid aortic valve stenosis at 29 centers were included. The primary outcome was death or stroke. After propensity score matching in 10 data sets generated by multiple imputation, outcomes from transcatheter aortic valve replacement to 3-year follow-up were computed by multivariable binomial logistic mixed-effects models, multivariable linear mixed-effects models, or multivariable frailty models accounting for center-related influences and residual confounding effects (doubly robust adjustment). The results were replicated by inverse probability of treatment weighting and multivariable adjustment. RESULTS: A total of 1443 consecutive patients with bicuspid aortic valve stenosis undergoing BE-THV (n=860) or SE-THV (n=583) implantation were included. In-hospital and 30-day death or stroke did not significantly differ between BE-THV and SE-THV groups (5.1% versus 6.1%; hazard ratio after propensity score matching, 1.02 [95% CI, 0.51–2.02]). BE-THV implantation was associated with higher annulus rupture and mean transvalvular gradient compared with SE-THV implantation. In contrast, SE-THV implantation was associated with higher additional valve implantation and paravalvular regurgitation compared with BE-THV implantation. The results were consistent across the statistical methods used and between early- and new-generation THVs. At 30 days, pacemaker implantation was lower in the BE-THV group compared with the SE-THV group (11.9% versus 18.6%; hazard ratio after propensity score matching, 0.58 [95% CI, 0.36–0.93]). This result did not depend on the statistical method used. At 3 years, consistent with the 1- and 2-year analyses, death or stroke was not significantly different between the BE-THV and SE-THV groups (23.7% versus 26.2%; hazard ratio after propensity score matching, 0.99 [95% CI, 0.65–1.51]). Death or stroke across major clinical, anatomical, functional, and procedural conditions was consistent with the main analysis. After inverse probability of treatment weighting and multivariable adjustment, these conclusions remained unchanged. CONCLUSIONS: In patients undergoing transcatheter aortic valve replacement for bicuspid aortic valve stenosis, death or stroke does not significantly differ between those receiving a BE-THV and those receiving an SE-THV over a follow-up of 3 years. BE-THV is associated with higher transvalvular mean gradient and more frequent annulus rupture, whereas SE-THV is associated with more frequent moderate to severe aortic regurgitation, additional THV implantation, and permanent pacemaker implantation.


  • Procedural and Clinical Outcomes According to Ultrasound-Guided Access in TAVI: A Propensity-Matched Comparative Subanalysis From the PULSE Registry

    by David Grundmann, Tanja Rudolph, Matti Adam, Caroline Kellner, Sabine Bleiziffer, Daniel Braun, Alexander R. Tamm, Max Meertens, Matthias Renker, Jonas Gmeiner, et al.

    BACKGROUND: Access-related vascular and bleeding complications during transcatheter aortic valve implantation (TAVI) are associated with significant morbidity and mortality. Ultrasound-guided (USG) puncture may reduce the incidence of these adverse events, particularly in large-bore arterial access. However, large-scale data on this approach are limited, and it has not yet been fully implemented into standard clinical practice. We compared access-related vascular and bleeding complications in USG versus fluoroscopy-guided access from a large multicenter TAVI registry. METHODS: The PULSE registry (Plug- or Suture-Based Vascular Closure After TAVI) retrospectively evaluated data of 9295 patients who underwent transfemoral TAVI at 10 high-volume German heart centers (2016–2021). USG and fluoroscopy-guided access were performed in 1992 (21.4%) and 7303 (78.6%) patients, respectively. Propensity score matching (1:1) yielded 895 matched pairs. The primary end point, a composite of minor and major vascular complications or bleeding type II-IV, was assessed according to Valve Academic Research Consortium definitions. RESULTS: Patients in the USG and fluoroscopy-guided groups (median age, 81.9 [78.3–85.0] years; 47.8% female patients) showed well-balanced baseline characteristics. The overall risk profile was comparable (median EuroSCORE II: 3.2 versus 3.5; SD, 0.007 [−0.086 to 0.099]). The composite primary end point occurred less frequently in the USG group (11.7% versus 16.0%; odds ratio, 0.7; P =0.01), driven by lower rates of procedural bleeding (5.4% versus 9.2%; odds ratio, 0.56; P =0.002) and with lower rates of endovascular treatment (0.7% versus 2.5%; P =0.005). CONCLUSIONS: In patients with transfemoral TAVI, USG access demonstrated lower rates of access-related vascular complications and type II-IV bleeding compared with fluoroscopy-guided access. Implementing USG puncture as the standard of care may improve access-related outcomes after TAVI.


  • Open Access

    Comparison of Latest Generation Intra‐ and Supra‐Annular Self‐Expanding Transcatheter Heart Valves for Aortic Valve‐in‐Valve Procedures

    by Antonia Katharina Stötzel, Oliver D. Bhadra, Lara Waldschmidt, Till J. Demal, David Grundmann, Lisa Voigtländer, Stefan Blankenberg, Hermann Reichenspurner, Niklas Schofer, Andreas Schaefer

    Background: Valve‐in‐valve (ViV) procedures are an established therapy. Self‐expanding (SE) supra‐annular transcatheter heart valves (THV) achieve superior hemodynamics compared to balloon‐expandable (BE) intra‐annular THV, but influence of stent design versus valve position remains unclear. Aims: This study compares SE intra‐ and supra‐annular THV for aortic ViV procedures to further elucidate this topic. Methods: From 05/2022 to 11/2023, 10 patients underwent ViV procedures with the SE intra‐annular Navitor valve. A control group of 22 patients treated with the SE supra‐annular Evolut R/PRO valve during the same period was retrieved from our database. Data were retrospectively analyzed according to updated valve academic research consortium (VARC) 3 definitions. A subgroup analysis matched patients for true internal diameter (ID) and body mass index (BMI). Results: Postprocedural transvalvular gradients were similar between groups. No differences in rates of significant paravalvular leakage (PVL) were seen ( p = 0.131). No all‐cause mortality occurred in either group. Device success (study group, Navitor: 70 [7] vs. control group, Evolut: 90.1 [20]; p = 0.293), early safety (90 [9] vs. 86.4 [19]; p = 1.000), permanent pacemaker implantation (PPI) (0 [0] vs. 9.1 [2]; p = 1.000), and stroke (0 [0] vs. 4.5 [1]; p = 1.000) were similar between groups. Procedure time was shorter for the study group (65.8 ± 27.9 min vs. 145.7 ± 51.3 min; p < 0.001). After matching for True ID and BMI these results persisted. Conclusion: Intra‐ and supra‐annular THV showed similar clinical and hemodynamic outcomes in aortic ViV procedures. These findings highlight the applicability of SE intra‐annular THV for aortic ViV procedures.


  • Open Access

    Rationale and Design of the REPEAT Trial: A Multicenter Randomized Trial Comparing Redo Surgical Aortic Valve Replacement to Valve‐in‐Valve Transcatheter Aortic Valve Replacement

    by Matthias Raschpichler, Suzanne de Waha, Stefan Blankenberg, Marcio A. Diniz, Emilia Bagiella, Annetine C. Gelijns, Vinicius F. Calsavara, Aakriti Gupta, Niklas Schofer, Tsuyoshi Kaneko, et al.

    Background: Redo surgical aortic valve replacement (rSAVR) has for long been the therapeutic reference standard for degenerated surgical aortic bioprostheses. Valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR) has emerged as an alternative for patients at high surgical risk due to its lower invasiveness. The long‐term clinical efficacy of ViV‐TAVR in patients at low to intermediate surgical risk remains unknown. Methods and Results: To compare clinical outcomes of redo surgical aortic valve replacement versus ViV‐TAVR in low‐ to intermediate‐risk patients with degenerated surgical aortic bioprostheses. REPEAT (Repeat Intervention for Deteriorated Surgical Bioprosthetic Aortic Valves) is an investigator‐initiated, international, multicenter, randomized, parallel, open‐label trial. A total of 890 patients aged <75 years with a failed surgical aortic bioprosthesis due to structural valve degeneration and low to intermediate surgical risk (ie, Society of Thoracic Surgeons predicted risk of death of <8%) will be randomly assigned in a 1:1 ratio to either redo surgical aortic valve replacement or ViV‐TAVR. The primary end point of REPEAT is a composite of all‐cause death, stroke (including both disabling and nondisabling), myocardial infarction, and rehospitalization for heart failure or aortic valve reintervention at 5 years, based on Valve Academic Research Consortium‐3 definitions. Secondary end points include each of the individual components of the primary composite end point, Valve Academic Research Consortium‐3–based conduction disturbances and arrhythmia, Valve Academic Research Consortium‐3–based wound and bleeding complications, functional status (ie, 6‐minute walk test, Kansas City Cardiomyopathy questionnaire), and treatment costs. Conclusions: The REPEAT trial has been designed to test the hypothesis that redo surgical aortic valve replacement is superior to ViV‐TAVR regarding clinical outcomes at 5 years in patients with degenerated surgical aortic bioprostheses and low to intermediate surgical risk.


  • Tricuspid valve replacement after dislocation of a transcatheter tricuspid heart valve

    by Andreas Schaefer, Niklas Schofer, Liesa Castro, Hermann Reichenspurner

    A 77-year-old female patient was referred to our department with dyspnoea, peripheral oedema and a history of right heart failure. Echocardiography revealed torrential tricuspid regurgitation. Since tricuspid-transcatheter edge-to-edge repair was not feasible and the patient refused open heart surgery, heart team decision was made to perform transcatheter tricuspid valve implantation in a borderline annulus dimension. During the procedure, migration of the valve in the right ventricle occurred. After patients’ consent was obtained surgical explantation of the valve with subsequent surgical tricuspid valve replacement was performed. Postoperative course was complicated by pneumonia, pleural effusion and right heart and respiratory failure. The patient was discharged home on postoperative day 19 in good clinical condition.

  • Open Access

    When the heart becomes suicidal: a case report of severe left ventricular outflow tract obstruction following transcatheter aortic valve implantation

    by Carl Schulz, Fabian J Brunner, Simon Pecha, Nils Sörensen, Niklas Schofer

    Background: Replacement of the aortic valve is a Class I recommendation for treatment of patients suffering from severe, symptomatic aortic stenosis. However, aortic valve replacement can occasionally lead to complications, including development of acute left ventricular outflow tract (LVOT) obstruction. This rare but severe complication is referred to as the so-called ‘suicide left ventricle’ phenomenon. Case summary: This case report presents an 88-year-old woman who developed severe LVOT obstruction following a successful transcatheter aortic valve implantation (TAVI), complicated by septal anterior motion of the mitral valve resulting in severe mitral regurgitation. Despite initial intensive care management, her symptoms persisted, necessitating the application of transcoronary ablation of septal hypertrophy as a bail-out procedure. Transcoronary ablation of septal hypertrophy, typically used in hypertrophic obstructive cardiomyopathy, successfully reduced the LVOT gradient and relieved symptoms. Discussion: This case emphasizes the importance of pre-operative identification of LVOT obstruction risk factors, awareness for this complication and a well-experience multidisciplinary team for the management of TAVI-associated complications.