Cameron Forbrigger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cameron Forbrigger has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Andrew Warkentin
Department of Mechanical Engineering, Dalhousie University, Halifax, Canada
3 shared publications- Eric Diller
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
3 shared publications Robert Bauer
Department of Mechanical Engineering, Dalhousie University, Halifax, Canada
3 shared publications- James Mbbs Drake
Wilfred and Joyce Posluns Centre for Image Guided Innovation and Therapeutic Intervention, Hospital for Sick Children, Toronto, ON, Canada
2 shared publications S Warnat
Dalhousie University
2 shared publications- Sajad Salmanipour
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ON M5S3G8 Canada
2 shared publications
Latest Publications
- 1 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 980-991
Electromagnets Under the Table: An Unobtrusive Magnetic Navigation System for Microsurgery
Miniature magnetic tools have the potential to enable minimally invasive surgical techniques to be applied to space-restricted surgical procedures in areas such as neurosurgery. However, typical magnetic navigation systems, which create the magnetic fields to drive such tools, either cannot generate large enough fields, or surround the patient in a way that obstructs surgeon access to the patient. This paper introduces the design of a magnetic navigation system with eight electromagnets arranged completely under the operating table, to endow the system with maximal workspace accessibility, which allows the patient to lie down on the top surface of the system without any constraints. The found geometric layout of the electromagnets maximizes the field strength and uniformity over a reasonable neurosurgical operating volume. The system can generate non-uniform magnetic fields up to 38 mT along the x and y axes and 47 mT along the z axis at a working distance of 120 mm away from the actuation system workbench, deep enough to deploy magnetic microsurgical tools in the brain. The forces which can be exerted on millimeter-scale magnets used in prototype neurosurgical tools are validated experimentally. Due to its large workspace, this system could be used to control milli-robots in a variety of surgical applications.
- 1 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 980-991
Electromagnets Under the Table: An Unobtrusive Magnetic Navigation System for Microsurgery
Miniature magnetic tools have the potential to enable minimally invasive surgical techniques to be applied to space-restricted surgical procedures in areas such as neurosurgery. However, typical magnetic navigation systems, which create the magnetic fields to drive such tools, either cannot generate large enough fields, or surround the patient in a way that obstructs surgeon access to the patient. This paper introduces the design of a magnetic navigation system with eight electromagnets arranged completely under the operating table, to endow the system with maximal workspace accessibility, which allows the patient to lie down on the top surface of the system without any constraints. The found geometric layout of the electromagnets maximizes the field strength and uniformity over a reasonable neurosurgical operating volume. The system can generate non-uniform magnetic fields up to 38 mT along the x and y axes and 47 mT along the z axis at a working distance of 120 mm away from the actuation system workbench, deep enough to deploy magnetic microsurgical tools in the brain. The forces which can be exerted on millimeter-scale magnets used in prototype neurosurgical tools are validated experimentally. Due to its large workspace, this system could be used to control milli-robots in a variety of surgical applications.
- Open Access
- 5 September 2023
- Published by Oxford University Press (OUP) in PNAS Nexus
- Vol. 2 (9) , pgad297
Inductive sensing of magnetic microrobots under actuation by rotating magnetic fields
The engineering space for magnetically manipulated biomedical microrobots is rapidly expanding. This includes synthetic, bioinspired, and biohybrid designs, some of which may eventually assume clinical roles aiding drug delivery or performing other therapeutic functions. Actuating these microrobots with rotating magnetic fields (RMFs) and the magnetic torques they exert offers the advantages of efficient mechanical energy transfer and scalable instrumentation. Nevertheless, closed-loop control still requires a complementary noninvasive imaging modality to reveal position and trajectory, such as ultrasound or X-rays, increasing complexity and posing a barrier to use. Here, we investigate the possibility of combining actuation and sensing via inductive detection of model microrobots under field magnitudes ranging from 100 s of microtesla to 10 s of millitesla rotating at 1 to 100 Hz. A prototype apparatus accomplishes this using adjustment mechanisms for both phase and amplitude to finely balance sense and compensation coils, suppressing the background signal of the driving RMF by 90 dB. Rather than relying on frequency decomposition to analyze signals, we show that, for rotational actuation, phase decomposition is more appropriate. We demonstrate inductive detection of a micromagnet placed in two distinct viscous environments using RMFs with fixed and time-varying frequencies. Finally, we show how magnetostatic selection fields can spatially isolate inductive signals from a micromagnet actuated by an RMF, with the resolution set by the relative magnitude of the selection field and the RMF. The concepts developed here lay a foundation for future closed-loop control schemes for magnetic microrobots based on simultaneous inductive sensing and actuation.
- 5 September 2023
- Published by Oxford University Press (OUP) in PNAS Nexus
- Vol. 2 (9) , pgad297
Open AccessInductive sensing of magnetic microrobots under actuation by rotating magnetic fields
The engineering space for magnetically manipulated biomedical microrobots is rapidly expanding. This includes synthetic, bioinspired, and biohybrid designs, some of which may eventually assume clinical roles aiding drug delivery or performing other therapeutic functions. Actuating these microrobots with rotating magnetic fields (RMFs) and the magnetic torques they exert offers the advantages of efficient mechanical energy transfer and scalable instrumentation. Nevertheless, closed-loop control still requires a complementary noninvasive imaging modality to reveal position and trajectory, such as ultrasound or X-rays, increasing complexity and posing a barrier to use. Here, we investigate the possibility of combining actuation and sensing via inductive detection of model microrobots under field magnitudes ranging from 100 s of microtesla to 10 s of millitesla rotating at 1 to 100 Hz. A prototype apparatus accomplishes this using adjustment mechanisms for both phase and amplitude to finely balance sense and compensation coils, suppressing the background signal of the driving RMF by 90 dB. Rather than relying on frequency decomposition to analyze signals, we show that, for rotational actuation, phase decomposition is more appropriate. We demonstrate inductive detection of a micromagnet placed in two distinct viscous environments using RMFs with fixed and time-varying frequencies. Finally, we show how magnetostatic selection fields can spatially isolate inductive signals from a micromagnet actuated by an RMF, with the resolution set by the relative magnitude of the selection field and the RMF. The concepts developed here lay a foundation for future closed-loop control schemes for magnetic microrobots based on simultaneous inductive sensing and actuation.
- 4 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (6) , 5541-5550
A Novel Magnetic Transmission for Powerful Miniature Surgical Robots
Untethered magnetically actuated robots present significant advantages for biomedical applications by allowing power to be delivered wirelessly to remote, miniature robots through flesh and bone. Nevertheless, generating enough usable force to interact with their environment remains a challenge: Most millimeter-size magnetic robots achieve forces of much less than 0.1 N, which limits their medical applications. Therefore, a compact, millimeter-scale transmission is needed to amplify the output force. A novel microtransmission system is presented, composed of a driving magnet suspended between two twisted string actuators. An analytical model of the transmission is formulated to predict its behavior under both fixed load and fixed displacement configurations. Experimental measurements are used to validate the predicted maximum achievable force, to quantify the transmission performance over numerous cycles, to determine the effect of different string materials, and to determine the impact of hysteresis and viscoelasticity. Finally, the transmission is integrated into a 3 mm diameter surgical gripper prototype to demonstrate its effectiveness. With only a modest 20 mT of applied magnetic field, the gripper generates 1.09 N gripping force—a factor of 35 improvement in mechanical advantage and a factor of 62 improvement in gripping force compared to a similar size gripper using direct magnetic actuation. This microtransmission for miniature magnetic robots will enable high-strength untethered robots for minimally invasive surgical applications.
- 4 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 27 (6) , 5541-5550
A Novel Magnetic Transmission for Powerful Miniature Surgical Robots
Untethered magnetically actuated robots present significant advantages for biomedical applications by allowing power to be delivered wirelessly to remote, miniature robots through flesh and bone. Nevertheless, generating enough usable force to interact with their environment remains a challenge: Most millimeter-size magnetic robots achieve forces of much less than 0.1 N, which limits their medical applications. Therefore, a compact, millimeter-scale transmission is needed to amplify the output force. A novel microtransmission system is presented, composed of a driving magnet suspended between two twisted string actuators. An analytical model of the transmission is formulated to predict its behavior under both fixed load and fixed displacement configurations. Experimental measurements are used to validate the predicted maximum achievable force, to quantify the transmission performance over numerous cycles, to determine the effect of different string materials, and to determine the impact of hysteresis and viscoelasticity. Finally, the transmission is integrated into a 3 mm diameter surgical gripper prototype to demonstrate its effectiveness. With only a modest 20 mT of applied magnetic field, the gripper generates 1.09 N gripping force—a factor of 35 improvement in mechanical advantage and a factor of 62 improvement in gripping force compared to a similar size gripper using direct magnetic actuation. This microtransmission for miniature magnetic robots will enable high-strength untethered robots for minimally invasive surgical applications.
- 21 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 4 (2) , 1202-1207
Cable-Less, Magnetically Driven Forceps for Minimally Invasive Surgery
A novel end-effector for surgical applications is presented that uses magnetic actuation in lieu of a more traditional cable-driven system. The gripper and wrist device consists of several magnets connected with compliant Nitinol joints that allow two rotational degrees of freedom and one gripping degree of freedom. As an end effector for an existing surgical robot arm, this device could augment existing minimally invasive surgical robots by allowing high distal dexterity in surgical sites with narrow and restricted access. A static deflection model of the device is used to design an open loop controller. The current prototype is capable of exerting pushing/pulling forces of 9 mN and gripping forces of 6 mN when magnetic flux densities of 20 mT are applied by a laboratory-scale electromagnetic coil system. These forces could be greatly amplified in a clinical-scale system to make brain tissue resection feasible. Under open loop control, the wrist of the device can maneuver from +π/4 rad to -π/4 rad in less than one second with a maximum error of 0.12 rad.
- 21 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 4 (2) , 1202-1207
Cable-Less, Magnetically Driven Forceps for Minimally Invasive Surgery
A novel end-effector for surgical applications is presented that uses magnetic actuation in lieu of a more traditional cable-driven system. The gripper and wrist device consists of several magnets connected with compliant Nitinol joints that allow two rotational degrees of freedom and one gripping degree of freedom. As an end effector for an existing surgical robot arm, this device could augment existing minimally invasive surgical robots by allowing high distal dexterity in surgical sites with narrow and restricted access. A static deflection model of the device is used to design an open loop controller. The current prototype is capable of exerting pushing/pulling forces of 9 mN and gripping forces of 6 mN when magnetic flux densities of 20 mT are applied by a laboratory-scale electromagnetic coil system. These forces could be greatly amplified in a clinical-scale system to make brain tissue resection feasible. Under open loop control, the wrist of the device can maneuver from +π/4 rad to -π/4 rad in less than one second with a maximum error of 0.12 rad.
- 31 July 2018
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 98 (9-12) , 3205-3216
Improving the accuracy of a profile grinding wheel grooving robot attachment for a CNC grinding machine
- 31 July 2018
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 98 (9-12) , 3205-3216
Improving the accuracy of a profile grinding wheel grooving robot attachment for a CNC grinding machine
- 11 May 2018
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 97 (5-8) , 2331-2340
Improving the performance of profile grinding wheels with helical grooves
- 11 May 2018
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 97 (5-8) , 2331-2340
Improving the performance of profile grinding wheels with helical grooves
- 11 October 2016
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 90 (5-8) , 2207-2216
A review of state-of-the-art vitrified bond grinding wheel grooving processes
- 11 October 2016
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 90 (5-8) , 2207-2216
A review of state-of-the-art vitrified bond grinding wheel grooving processes
- 6 August 2015
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (9)
Nano-scale measurement of sub-micrometer MEMS in-plane dynamics using synchronized illumination
A method for measuring the sub-micrometer in-plane dynamics of MEMS devices with nano-scale precision using a CCD camera and synchronized pulsating illumination is presented. Typical MEMS actuators have fast responses (generally in the 1–200 kHz range), much faster than typical cameras which record a time averaged motion. Under constant illumination the average displacement is steady state and independent of dynamic amplitude or phase. Methods such as strobe illumination use short light pulses to freeze the motion. This paper develops the use of longer pulses of illumination that do not freeze the image, but make the average displacement depend on dynamic amplitude and phase; thus allowing both properties to be extracted. The expected signal is derived as a function of light pulse width and delay, and short versus longer pulses are compared. Measurements using a conventional microscope with replacement of the lamp with LEDs confirmed the derived equations. The system was used to measure sub-micrometer motion of MEMS actuators with ~5 nm precision. The time constant of a thermal actuator was measured and found to be 48 µ s. A resonant peak of a MEMS device was measured at 123.30 kHz with an amplitude of 238 nm.
- 6 August 2015
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (9)
Nano-scale measurement of sub-micrometer MEMS in-plane dynamics using synchronized illumination
A method for measuring the sub-micrometer in-plane dynamics of MEMS devices with nano-scale precision using a CCD camera and synchronized pulsating illumination is presented. Typical MEMS actuators have fast responses (generally in the 1–200 kHz range), much faster than typical cameras which record a time averaged motion. Under constant illumination the average displacement is steady state and independent of dynamic amplitude or phase. Methods such as strobe illumination use short light pulses to freeze the motion. This paper develops the use of longer pulses of illumination that do not freeze the image, but make the average displacement depend on dynamic amplitude and phase; thus allowing both properties to be extracted. The expected signal is derived as a function of light pulse width and delay, and short versus longer pulses are compared. Measurements using a conventional microscope with replacement of the lamp with LEDs confirmed the derived equations. The system was used to measure sub-micrometer motion of MEMS actuators with ~5 nm precision. The time constant of a thermal actuator was measured and found to be 48 µ s. A resonant peak of a MEMS device was measured at 123.30 kHz with an amplitude of 238 nm.
- 22 January 2015
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (2)
PolyMUMPs MEMS device to measure mechanical stiffness of single cells in aqueous media
A method of experimentally determining the mechanical stiffness of single cells by using differential displacement measurements in a two stage spring system is presented. The spring system consists of a known MEMS reference spring and an unknown cellular stiffness: the ratio of displacements is related to the ratio of stiffness. A polyMUMPs implementation for aqueous media is presented and displacement measurements made from optical microphotographs using a FFT based displacement method with a repeatability of ~20 nm. The approach was first validated on a MEMS two stage spring system of known stiffness. The measured stiffness ratios of control structures (i) MEMS spring systems and (ii) polystyrene microspheres were found to agree with theoretical values. Mechanical tests were then performed on Saccharomyces cerevisiae (Baker’s yeast) in aqueous media. Cells were placed (using a micropipette) inside MEMS measuring structures and compressed between two jaws using an electrostatic actuator and displacements measured. Tested cells showed stiffness values between 5.4 and 8.4 N m −1 with an uncertainty of 11%. In addition, non-viable cells were tested by exposing viable cells to methanol. The resultant mean cell stiffness dropped by factor of 3 × and an explicit discrimination between viable and non-viable cells based on mechanical stiffness was seen.
- 22 January 2015
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (2)
PolyMUMPs MEMS device to measure mechanical stiffness of single cells in aqueous media
A method of experimentally determining the mechanical stiffness of single cells by using differential displacement measurements in a two stage spring system is presented. The spring system consists of a known MEMS reference spring and an unknown cellular stiffness: the ratio of displacements is related to the ratio of stiffness. A polyMUMPs implementation for aqueous media is presented and displacement measurements made from optical microphotographs using a FFT based displacement method with a repeatability of ~20 nm. The approach was first validated on a MEMS two stage spring system of known stiffness. The measured stiffness ratios of control structures (i) MEMS spring systems and (ii) polystyrene microspheres were found to agree with theoretical values. Mechanical tests were then performed on Saccharomyces cerevisiae (Baker’s yeast) in aqueous media. Cells were placed (using a micropipette) inside MEMS measuring structures and compressed between two jaws using an electrostatic actuator and displacements measured. Tested cells showed stiffness values between 5.4 and 8.4 N m −1 with an uncertainty of 11%. In addition, non-viable cells were tested by exposing viable cells to methanol. The resultant mean cell stiffness dropped by factor of 3 × and an explicit discrimination between viable and non-viable cells based on mechanical stiffness was seen.