Jaewon Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jaewon Park has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Arum Han
Texas A&M University
15 shared publications Jee Young Kim
Department of Earth Resources and Environmental Engineering, Hanyang University, Seoul, 04763, South Korea
7 shared publications- Jianrong Li
Texas A&M Institute for Neuroscience, Texas A&M University, College Station, TX, United States
7 shared publications - Yoon-E Choi
Division of Environmental Science & Ecological Engineering, Korea University, Seoul, Republic of Korea
7 shared publications Hyun Soo Kim
Department of Electronic Engineering, Kwangwoon University, Seoul, 01897, South Korea
6 shared publications- Hyun Soo Kim
Department of Electronic Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea
6 shared publications
Latest Publications
- 1 July 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (7) , 075011
Variable roughness soft gripper fingertip with pneumatically deployable microspike array
This paper presents a pneumatically actuated variable-roughness fingertip that reversibly switches a single polydimethylsiloxane (PDMS) contact surface between flat and spike modes. Under negative pressure, the internal chamber contracts, retracting the spikes beneath the cover to form a flat contact state. Conversely, under positive pressure, the chamber expands and deploys the spikes, creating a contact state in which the microstructures can engage the counter surface directly. The protruding geometry in the spike mode can deteriorate under increasing normal load; therefore, we encapsulated a resin-based medial axis tree support structure inside the PDMS spikes to enhance the load-bearing capability and preserve the deployed shape. Friction tests performed on glass, paper, and sandpaper revealed that the friction coefficient was higher in the flat mode on glass, while it was higher in the spike mode on paper and sandpaper, indicating a crossover in the preferred mode based on surface conditions. Grasping tests confirmed the same trend: on glass, the gripping force in the flat mode was 35.8% higher, while on sandpaper, the gripping force in the spike mode was 23.9% higher. These results demonstrate that the performance advantage of flat versus spike contact can be reversed with surface roughness, highlighting the utility of a switchable contact interface for mixed-roughness environments.
- 1 July 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (7) , 075011
Variable roughness soft gripper fingertip with pneumatically deployable microspike array
This paper presents a pneumatically actuated variable-roughness fingertip that reversibly switches a single polydimethylsiloxane (PDMS) contact surface between flat and spike modes. Under negative pressure, the internal chamber contracts, retracting the spikes beneath the cover to form a flat contact state. Conversely, under positive pressure, the chamber expands and deploys the spikes, creating a contact state in which the microstructures can engage the counter surface directly. The protruding geometry in the spike mode can deteriorate under increasing normal load; therefore, we encapsulated a resin-based medial axis tree support structure inside the PDMS spikes to enhance the load-bearing capability and preserve the deployed shape. Friction tests performed on glass, paper, and sandpaper revealed that the friction coefficient was higher in the flat mode on glass, while it was higher in the spike mode on paper and sandpaper, indicating a crossover in the preferred mode based on surface conditions. Grasping tests confirmed the same trend: on glass, the gripping force in the flat mode was 35.8% higher, while on sandpaper, the gripping force in the spike mode was 23.9% higher. These results demonstrate that the performance advantage of flat versus spike contact can be reversed with surface roughness, highlighting the utility of a switchable contact interface for mixed-roughness environments.
- Open Access
- 31 May 2025
- Published by Elsevier in Materials & Design
- Vol. 255
Jamming-induced stiffness modulation using 3D-printed hexagonal microfibers in cylindrical structures
- 31 May 2025
- Published by Elsevier in Materials & Design
- Vol. 255
Open AccessJamming-induced stiffness modulation using 3D-printed hexagonal microfibers in cylindrical structures
- 5 April 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (9) , 2217-2227
Facilitation of axonal transcriptome analysis with quantitative microfluidic devices
Two newly developed quantitative chambers, multi-compartmental quantitative bipartite chamber (MQBC) and long quantitative tripartite chamber (LQTC), could dramatically increase the efficiency in collecting axonal RNA.
- 5 April 2023
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (9) , 2217-2227
Facilitation of axonal transcriptome analysis with quantitative microfluidic devices
Two newly developed quantitative chambers, multi-compartmental quantitative bipartite chamber (MQBC) and long quantitative tripartite chamber (LQTC), could dramatically increase the efficiency in collecting axonal RNA.
- 24 January 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 870, 161783
The cytotoxicity of nano- and micro-sized graphene oxides on microalgae depends on the characteristics of cell wall and flagella
- 24 January 2023
- Published by Elsevier in Science of The Total Environment
- Vol. 870, 161783
The cytotoxicity of nano- and micro-sized graphene oxides on microalgae depends on the characteristics of cell wall and flagella
- Open Access
- 15 January 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (1) , 223
Monodisperse Micro-Droplet Generation in Microfluidic Channel with Asymmetric Cross-Sectional Shape
Micro-droplets are widely used in the fields of chemical and biological research, such as drug delivery, material synthesis, point-of-care diagnostics, and digital PCR. Droplet-based microfluidics has many advantages, such as small reagent consumption, fast reaction time, and independent control of each droplet. Therefore, various micro-droplet generation methods have been proposed, including T-junction breakup, capillary flow-focusing, planar flow-focusing, step emulsification, and high aspect (height-to-width) ratio confinement. In this study, we propose a microfluidic device for generating monodisperse micro-droplets, the microfluidic channel of which has an asymmetric cross-sectional shape and high hypotenuse-to-width ratio (HTWR). It was fabricated using basic MEMS processes, such as photolithography, anisotropic wet etching of Si, and polydimethylsiloxane (PDMS) molding. Due to the geometric similarity of a Si channel and a PDMS mold, both of which were created through the anisotropic etching process of a single crystal Si, the microfluidic channel with the asymmetric cross-sectional shape and high HTWR was easily realized. The effects of HTWR of channels on the size and uniformity of generated micro-droplets were investigated. The monodisperse micro-droplets were generated as the HTWR of the asymmetric channel was over 3.5. In addition, it was found that the flow direction of the oil solution (continuous phase) affected the size of micro-droplets due to the asymmetric channel structures. Two kinds of monodisperse droplets with different sizes were successfully generated for a wider range of flow rates using the asymmetric channel structure in the developed microfluidic device.
- 15 January 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (1) , 223
Open AccessMonodisperse Micro-Droplet Generation in Microfluidic Channel with Asymmetric Cross-Sectional Shape
Micro-droplets are widely used in the fields of chemical and biological research, such as drug delivery, material synthesis, point-of-care diagnostics, and digital PCR. Droplet-based microfluidics has many advantages, such as small reagent consumption, fast reaction time, and independent control of each droplet. Therefore, various micro-droplet generation methods have been proposed, including T-junction breakup, capillary flow-focusing, planar flow-focusing, step emulsification, and high aspect (height-to-width) ratio confinement. In this study, we propose a microfluidic device for generating monodisperse micro-droplets, the microfluidic channel of which has an asymmetric cross-sectional shape and high hypotenuse-to-width ratio (HTWR). It was fabricated using basic MEMS processes, such as photolithography, anisotropic wet etching of Si, and polydimethylsiloxane (PDMS) molding. Due to the geometric similarity of a Si channel and a PDMS mold, both of which were created through the anisotropic etching process of a single crystal Si, the microfluidic channel with the asymmetric cross-sectional shape and high HTWR was easily realized. The effects of HTWR of channels on the size and uniformity of generated micro-droplets were investigated. The monodisperse micro-droplets were generated as the HTWR of the asymmetric channel was over 3.5. In addition, it was found that the flow direction of the oil solution (continuous phase) affected the size of micro-droplets due to the asymmetric channel structures. Two kinds of monodisperse droplets with different sizes were successfully generated for a wider range of flow rates using the asymmetric channel structure in the developed microfluidic device.
- Open Access
- 14 February 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (2) , 118
High-Aspect-Ratio Microfluidic Channel with Parallelogram Cross-Section for Monodisperse Droplet Generation
Droplet-based microfluidics has been widely used as a potent high-throughput platform due to various advantages, such as a small volume of reagent consumption, massive production of droplets, fast reaction time, and independent control of each droplet. Therefore, droplet microfluidic systems demand the reliable generation of droplets with precise and effective control over their size and distribution, which is critically important for various applications in the fields of chemical analysis, material synthesis, lab-on-a-chip, cell research, diagnostic test, and so on. In this study, we propose a microfluidic device with a high-aspect-ratio (HAR) channel, which has a parallelogram cross-section, for generating monodisperse droplets. The HAR channel was fabricated using simple and cheap MEMS processes, such as photolithography, anisotropic wet etching, and PDMS molding, without expensive equipment. In addition, the parallelogram cross-section channel structure, regarded as a difficult shape to implement in previous fabrication methods, was easily formed by the self-alignment between the silicon channel and the PDMS mold, both of which were created from a single crystal silicon through an anisotropic etching process. We investigated the effects of the cross-sectional shape (parallelogram vs. rectangle) and height-to-width ratio of microfluidic channels on the size and uniformity of generated droplets. Using the developed HAR channel with the parallelogram cross-section, we successfully obtained smaller monodisperse droplets for a wider range of flow rates, compared with a previously reported HAR channel with a rectangular cross-section.
- 14 February 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (2) , 118
Open AccessHigh-Aspect-Ratio Microfluidic Channel with Parallelogram Cross-Section for Monodisperse Droplet Generation
Droplet-based microfluidics has been widely used as a potent high-throughput platform due to various advantages, such as a small volume of reagent consumption, massive production of droplets, fast reaction time, and independent control of each droplet. Therefore, droplet microfluidic systems demand the reliable generation of droplets with precise and effective control over their size and distribution, which is critically important for various applications in the fields of chemical analysis, material synthesis, lab-on-a-chip, cell research, diagnostic test, and so on. In this study, we propose a microfluidic device with a high-aspect-ratio (HAR) channel, which has a parallelogram cross-section, for generating monodisperse droplets. The HAR channel was fabricated using simple and cheap MEMS processes, such as photolithography, anisotropic wet etching, and PDMS molding, without expensive equipment. In addition, the parallelogram cross-section channel structure, regarded as a difficult shape to implement in previous fabrication methods, was easily formed by the self-alignment between the silicon channel and the PDMS mold, both of which were created from a single crystal silicon through an anisotropic etching process. We investigated the effects of the cross-sectional shape (parallelogram vs. rectangle) and height-to-width ratio of microfluidic channels on the size and uniformity of generated droplets. Using the developed HAR channel with the parallelogram cross-section, we successfully obtained smaller monodisperse droplets for a wider range of flow rates, compared with a previously reported HAR channel with a rectangular cross-section.
- 1 February 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 198, 113839
Fluorogenic “on-off” nanosensor based on dual-quenching effect for imaging intracellular metabolite of various microalgae
- 1 February 2022
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 198, 113839
Fluorogenic “on-off” nanosensor based on dual-quenching effect for imaging intracellular metabolite of various microalgae
- Open Access
- 29 June 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (7) , 213
Wearable Intracranial Pressure Monitoring Sensor for Infants
Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To date, invasive measurements are still the standard method for monitoring ICP; however, these methods can not only cause bleeding or infection but are also very inconvenient to use, particularly for infants. Currently, none of the non-invasive methods can provide sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use at low cost. Here, we have developed a wearable, non-invasive ICP sensor that can be used like a band-aid. For the fabrication of the ICP sensor, a novel freeze casting method was developed to encapsulate the liquid metal microstructures within thin and flexible polymers. The final thickness of the ICP sensor demonstrated is 500 µm and can be further reduced. Three different designs of ICP sensors were tested under various pressure actuation conditions as well as different temperature environments, where the measured pressure changes were stable with the largest stability coefficient of variation being only CV = 0.0206. In addition, the sensor output values showed an extremely high linear correlation (R2 > 0.9990) with the applied pressures.
- 29 June 2021
- Published by MDPI AG in Biosensors
- Vol. 11 (7) , 213
Open AccessWearable Intracranial Pressure Monitoring Sensor for Infants
Monitoring of intracranial pressure (ICP) is important for patients at risk of raised ICP, which may indicate developing diseases in brains that can lead to brain damage or even death. Monitoring ICP can be invaluable in the management of patients suffering from brain injury or hydrocephalus. To date, invasive measurements are still the standard method for monitoring ICP; however, these methods can not only cause bleeding or infection but are also very inconvenient to use, particularly for infants. Currently, none of the non-invasive methods can provide sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use at low cost. Here, we have developed a wearable, non-invasive ICP sensor that can be used like a band-aid. For the fabrication of the ICP sensor, a novel freeze casting method was developed to encapsulate the liquid metal microstructures within thin and flexible polymers. The final thickness of the ICP sensor demonstrated is 500 µm and can be further reduced. Three different designs of ICP sensors were tested under various pressure actuation conditions as well as different temperature environments, where the measured pressure changes were stable with the largest stability coefficient of variation being only CV = 0.0206. In addition, the sensor output values showed an extremely high linear correlation (R2 > 0.9990) with the applied pressures.
- Open Access
Detection of Particulate Matters with a Field-Portable Microscope Using Side-Illuminated Total Internal Reflection
Field-portable observation and analysis of particulate matter (PM) is required to enhance healthy lives. Various types of the PM measurement methods are in use; however, each of these methods has significant limitations in that real time measurement is impossible, the detection system is bulky, or the measurement accuracy is insufficient. In this work, we introduce an optical method to perform a fast and accurate PM analysis with a higher-contrast microscopic image enabled by a side-illuminated total internal reflection (TIR) technique to be implemented in a compact device. The superiority of the proposed method was quantitatively demonstrated by comparing the signal-to-noise ratio of the proposed side-illuminated TIR method with a traditional halogen lamp-based transmission microscope. With the proposed device, signal-to-noise ratios (SNRs) for microbeads (5~20 µm) and ultrafine dust particles (>5 µm) increased 4.5~17 and 4~10 dB, respectively, compared to the conventional transmission microscope. As a proof of concept, the proposed method was also applied to a low-cost commercial smartphone toy microscope enabling field-portable detection of PMs. We believe that the proposed side-illuminated TIR PM detection device holds significant advantages over other commonly used systems due to its sufficient detection capability along with simple and compact configuration as well as low cost.
Open AccessDetection of Particulate Matters with a Field-Portable Microscope Using Side-Illuminated Total Internal Reflection
Field-portable observation and analysis of particulate matter (PM) is required to enhance healthy lives. Various types of the PM measurement methods are in use; however, each of these methods has significant limitations in that real time measurement is impossible, the detection system is bulky, or the measurement accuracy is insufficient. In this work, we introduce an optical method to perform a fast and accurate PM analysis with a higher-contrast microscopic image enabled by a side-illuminated total internal reflection (TIR) technique to be implemented in a compact device. The superiority of the proposed method was quantitatively demonstrated by comparing the signal-to-noise ratio of the proposed side-illuminated TIR method with a traditional halogen lamp-based transmission microscope. With the proposed device, signal-to-noise ratios (SNRs) for microbeads (5~20 µm) and ultrafine dust particles (>5 µm) increased 4.5~17 and 4~10 dB, respectively, compared to the conventional transmission microscope. As a proof of concept, the proposed method was also applied to a low-cost commercial smartphone toy microscope enabling field-portable detection of PMs. We believe that the proposed side-illuminated TIR PM detection device holds significant advantages over other commonly used systems due to its sufficient detection capability along with simple and compact configuration as well as low cost.