Fathin Saifur Rahman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fathin Saifur Rahman has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Nanang Hariyanto
3 shared publicationsMuhammad Nurdin
2 shared publications- Thongchart Kerdphol
Department of Electrical Engineering, Faculty of Engineering, Kasetsart University, Bangkok, Thailand
2 shared publications - Kanet Katchasuwanmanee
Department of Mechanical Engineering, Faculty of Engineering, Kasetsart University, Bangkok 10900, Thailand
1 shared publication Masayuki Watanabe
1 shared publication- Nottakorn Sukmanont
Department of Electrical Engineering, Faculty of Engineering, Kasetsart University, Bangkok, Thailand
1 shared publication
Latest Publications
- Open Access
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 44403-44416
Stability-Oriented Design of Adaptive Model Predictive Control With LCL-Filtered for Grid-Forming Inverters
In a future grid transitioning from conventional synchronous generation to clean-energy-dominated operation, grid-forming inverters (GFMIs) are pivotal for the seamless integration of renewable sources. However, conventional proportional–integral (PI) control has limited robustness to operating-point shifts, disturbances, and cyber threats. This study proposes an adaptive model predictive control (AMPC) scheme for GFMIs that combines constraint-aware optimal control with online adaptation and incorporates a Kalman-filter-based state estimator to mitigate measurement noise and reduce vulnerability to sensor spoofing and other cyber-induced disturbances. The AMPC scheme is evaluated in simulation under nominal conditions, in adaptation-critical scenarios including cyber-attack emulation, and during fault events that drive transitions to islanded operation. Results show that AMPC achieves superior transient and steady-state performance, with improved regulation of voltage, current, and frequency compared with PI control and non-adaptive MPC, and it demonstrates enhanced transient harmonic performance. These outcomes demonstrate the controller’s robustness across diverse operating scenarios and highlight its potential to support reliable renewable-rich power systems, aligning with long-term pathways toward carbon neutrality.
- 19 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 44403-44416
Open AccessStability-Oriented Design of Adaptive Model Predictive Control With LCL-Filtered for Grid-Forming Inverters
In a future grid transitioning from conventional synchronous generation to clean-energy-dominated operation, grid-forming inverters (GFMIs) are pivotal for the seamless integration of renewable sources. However, conventional proportional–integral (PI) control has limited robustness to operating-point shifts, disturbances, and cyber threats. This study proposes an adaptive model predictive control (AMPC) scheme for GFMIs that combines constraint-aware optimal control with online adaptation and incorporates a Kalman-filter-based state estimator to mitigate measurement noise and reduce vulnerability to sensor spoofing and other cyber-induced disturbances. The AMPC scheme is evaluated in simulation under nominal conditions, in adaptation-critical scenarios including cyber-attack emulation, and during fault events that drive transitions to islanded operation. Results show that AMPC achieves superior transient and steady-state performance, with improved regulation of voltage, current, and frequency compared with PI control and non-adaptive MPC, and it demonstrates enhanced transient harmonic performance. These outcomes demonstrate the controller’s robustness across diverse operating scenarios and highlight its potential to support reliable renewable-rich power systems, aligning with long-term pathways toward carbon neutrality.
- 1 May 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 170, 294-302
Optimization of virtual inertia considering system frequency protection scheme
- 1 May 2019
- Published by Elsevier in Electric Power Systems Research
- Vol. 170, 294-302
Optimization of virtual inertia considering system frequency protection scheme
- Open Access
- 30 June 2014
- Published by School of Electrical Engineering and Informatics (STEI) ITB in International Journal on Electrical Engineering and Informatics
- Vol. 6 (2) , 435-446
Placement of Shunt VAR Compensator Based on Sensitivity Analysis
- 30 June 2014
- Published by School of Electrical Engineering and Informatics (STEI) ITB in International Journal on Electrical Engineering and Informatics
- Vol. 6 (2) , 435-446
Open AccessPlacement of Shunt VAR Compensator Based on Sensitivity Analysis
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 750-753
Underfrequency load shedding scheme using generator coherency approach
In power system operation, frequency issue caused by power imbalance between generation and load can occur in power system. If generation is smaller than load, system frequency will drop. When generation deficiency is too large, system frequency will decrease significantly which can lead to system blackout. To solve this frequency issue, proper underfrequency load shedding and islanding scheme is essential to prevent further deviation of system frequency from its nominal frequency. In this research, conventional underfrequency load shedding and islanding scheme using generator coherency approach are designed for Southern Sulawesi system, one of power system in Sulawesi, Indonesia. Southern Sulawesi system is not too large with peak load of about 800-1000 MW therefore easier to analyze performance of the method used in this research. The simulations were performed using DIgSILENT PowerFactory. Underfrequency load shedding and islanding scheme obtained can be applied to all scenarios simulated in this research with good performance.
- 1 May 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 750-753
Underfrequency load shedding scheme using generator coherency approach
In power system operation, frequency issue caused by power imbalance between generation and load can occur in power system. If generation is smaller than load, system frequency will drop. When generation deficiency is too large, system frequency will decrease significantly which can lead to system blackout. To solve this frequency issue, proper underfrequency load shedding and islanding scheme is essential to prevent further deviation of system frequency from its nominal frequency. In this research, conventional underfrequency load shedding and islanding scheme using generator coherency approach are designed for Southern Sulawesi system, one of power system in Sulawesi, Indonesia. Southern Sulawesi system is not too large with peak load of about 800-1000 MW therefore easier to analyze performance of the method used in this research. The simulations were performed using DIgSILENT PowerFactory. Underfrequency load shedding and islanding scheme obtained can be applied to all scenarios simulated in this research with good performance.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1231-1235
An approach of generator coherency for underfrequency load shedding and islanding mechanism: Study on Sulawesi Selatan-Tenggara-Barat (Sulselrabar) System, Sulawesi, Indonesia
In power system operation, frequency issue caused by power imbalance between generation and load can be happened in power system. If generation is smaller than load, system frequency will drop. When generation deficiency is too large, system frequency will decrease significantly which can lead to system blackout. To solve this frequency issue, proper under-frequency load shedding and also islanding scheme is essential to prevent continuous decreasing of system frequency. In this paper, conventional under-frequency load shedding and islanding scheme based on generator coherency is designed for Sulawesi Selatan-Tenggara-Barat (Sulselrabar) system, one of power system in Sulawesi, Indonesia. Sulselrabar system isn't too large with peak load of about 800 MW therefore application of conventional under-frequency load shedding and islanding scheme is adequate. All simulations in this paper were performed using DIgSILENT Power Factory.
- 1 September 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1231-1235
An approach of generator coherency for underfrequency load shedding and islanding mechanism: Study on Sulawesi Selatan-Tenggara-Barat (Sulselrabar) System, Sulawesi, Indonesia
In power system operation, frequency issue caused by power imbalance between generation and load can be happened in power system. If generation is smaller than load, system frequency will drop. When generation deficiency is too large, system frequency will decrease significantly which can lead to system blackout. To solve this frequency issue, proper under-frequency load shedding and also islanding scheme is essential to prevent continuous decreasing of system frequency. In this paper, conventional under-frequency load shedding and islanding scheme based on generator coherency is designed for Sulawesi Selatan-Tenggara-Barat (Sulselrabar) system, one of power system in Sulawesi, Indonesia. Sulselrabar system isn't too large with peak load of about 800 MW therefore application of conventional under-frequency load shedding and islanding scheme is adequate. All simulations in this paper were performed using DIgSILENT Power Factory.