David F. Black
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David F. Black has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Kirk M. Welker
Department of Radiology, Mayo Clinic, Rochester, USA
4 shared publications - Norbert G. Campeau
From the Department of Radiology (G.B., P.R., P.J.F., N.g.C., V.M.S.), Mayo Clinic, 200 1st Street Southwest, Rochester, MN 55902
4 shared publications - Steven A. Messina
Division of Neuroradiology, Department of Radiology, Mayo Clinic, Rochester, Minn
4 shared publications - Amit Agarwal
The University of Texas MD Anderson Cancer Center, Houston, USA
3 shared publications - Brice Fernandez
GE Healthcare Buc France
3 shared publications - Daehun Kang
Department of Radiology, Mayo Clinic, Rochester, MN
3 shared publications
Latest Publications
- 5 September 2026
- Published by Springer Nature in Neuroradiology
- p. 1-11
Large language models in neuroradiology: an international survey of awareness, applications, and concerns
- 5 September 2026
- Published by Springer Nature in Neuroradiology
- p. 1-11
Large language models in neuroradiology: an international survey of awareness, applications, and concerns
- Open Access
- 30 September 2025
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 11 (1) , 1-10
3D printing of an optic pathway model from 7T MRI for education
The optic pathway is a complex neural structure responsible for transmitting visual information from the retina to the brain. Traditionally, the optic pathway has been depicted using two-dimensional (2D) illustrations, which, while useful for simplification, can obscure depth, orientation, and connectivity, limiting a full understanding of its three-dimensional (3D) nature which is important for surgical planning and neuroanatomy education. Due to a convergence of advancing technologies in MRI image acquisition, medical CAD and 3D illustration software, as well as 3D printing technologies, these 3D visualizations can now be physically manufactured to provide life size, patient specific, physical, color-coded 3D models. 3D models manufactured from advanced imaging can provide a more accurate, interactive, non-invasive, cost-effective alternative to medical illustration and animation than traditional dissected cadaveric anatomical specimens for both clinical and educational purposes. The source data for this project came from both a 42 year old male patient and a 21 year old male volunteer after both had been scanned on the same seven tesla MRI including DTI for the patient and volumetric sequences for the volunteer. The model was created by segmenting the optic pathway using medical CAD software and 3D illustration software. The DTI tracts were coregistered to the anatomic brain. The model was optimized for printing and hypothetical “lesions” were added along the pathway with their corresponding visual deficits. The model was printed on an HP580 multijet fusion color printer and photorealistic eyes were printed using material jetting of photopolymer via a Stratasys J750 printer. Multiple challenges were overcome to successfully create a life size, physical, multicolor 3D printed representation of the optic pathway created from 7T MRI data. This workflow resulted in a unique educational 3D representation of the human optic pathway that allows for direct manipulation, haptic feedback, and clear understanding of the anatomic relations both of this system normally and the correlations between lesion location and resultant expected visual field impairment. As opposed to the inconvenience, costs, and limited access accompanying the classical standard of advanced dissections of human specimens, this model is available to all learners in all environments.
- 30 September 2025
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 11 (1) , 1-10
Open Access3D printing of an optic pathway model from 7T MRI for education
The optic pathway is a complex neural structure responsible for transmitting visual information from the retina to the brain. Traditionally, the optic pathway has been depicted using two-dimensional (2D) illustrations, which, while useful for simplification, can obscure depth, orientation, and connectivity, limiting a full understanding of its three-dimensional (3D) nature which is important for surgical planning and neuroanatomy education. Due to a convergence of advancing technologies in MRI image acquisition, medical CAD and 3D illustration software, as well as 3D printing technologies, these 3D visualizations can now be physically manufactured to provide life size, patient specific, physical, color-coded 3D models. 3D models manufactured from advanced imaging can provide a more accurate, interactive, non-invasive, cost-effective alternative to medical illustration and animation than traditional dissected cadaveric anatomical specimens for both clinical and educational purposes. The source data for this project came from both a 42 year old male patient and a 21 year old male volunteer after both had been scanned on the same seven tesla MRI including DTI for the patient and volumetric sequences for the volunteer. The model was created by segmenting the optic pathway using medical CAD software and 3D illustration software. The DTI tracts were coregistered to the anatomic brain. The model was optimized for printing and hypothetical “lesions” were added along the pathway with their corresponding visual deficits. The model was printed on an HP580 multijet fusion color printer and photorealistic eyes were printed using material jetting of photopolymer via a Stratasys J750 printer. Multiple challenges were overcome to successfully create a life size, physical, multicolor 3D printed representation of the optic pathway created from 7T MRI data. This workflow resulted in a unique educational 3D representation of the human optic pathway that allows for direct manipulation, haptic feedback, and clear understanding of the anatomic relations both of this system normally and the correlations between lesion location and resultant expected visual field impairment. As opposed to the inconvenience, costs, and limited access accompanying the classical standard of advanced dissections of human specimens, this model is available to all learners in all environments.
- 21 June 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (3) , 457-464
Imaging Findings in Giant Cell Arteritis: Don’t Turn a Blind Eye to the Obvious!
Giant cell arteritis (GCA) is the most common primary large vessel systemic vasculitis in the western world. Even though the involvement of scalp and intracranial vessels has received much attention in the neuroradiology literature, GCA, being a systemic vasculitis can involve multiple other larger vessels including aorta and its major head and neck branches. Herein, the authors present a pictorial review of the various cranial, extracranial and orbital manifestations of GCA. An increased awareness of this entity may help with timely and accurate diagnosis, helping expedite therapy and preventing serious complications. ABBREVIATIONS: ACR= American College of Rheumatology, AION= Anterior Ischemic Optic Neuropathy, EULAR= European League Against Rheumatism, GCA= Giant Cell Arteritis, LV-GCA= Large vessel GCA, PMR= Polymyalgia Rheumatica, US= Ultrasound, VWI= Vessel Wall Imaging.
- 21 June 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (3) , 457-464
Imaging Findings in Giant Cell Arteritis: Don’t Turn a Blind Eye to the Obvious!
Giant cell arteritis (GCA) is the most common primary large vessel systemic vasculitis in the western world. Even though the involvement of scalp and intracranial vessels has received much attention in the neuroradiology literature, GCA, being a systemic vasculitis can involve multiple other larger vessels including aorta and its major head and neck branches. Herein, the authors present a pictorial review of the various cranial, extracranial and orbital manifestations of GCA. An increased awareness of this entity may help with timely and accurate diagnosis, helping expedite therapy and preventing serious complications. ABBREVIATIONS: ACR= American College of Rheumatology, AION= Anterior Ischemic Optic Neuropathy, EULAR= European League Against Rheumatism, GCA= Giant Cell Arteritis, LV-GCA= Large vessel GCA, PMR= Polymyalgia Rheumatica, US= Ultrasound, VWI= Vessel Wall Imaging.
- 18 June 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (11) , 1655-1660
Deep Learning–Based Reconstruction of 3D T1 SPACE Vessel Wall Imaging Provides Improved Image Quality with Reduced Scan Times: A Preliminary Study
BACKGROUND AND PURPOSE: Intra-cranial vessel wall imaging (IC-VWI) is technically challenging to implement, given the simultaneous requirements of high spatial resolution, excellent blood and CSF signal suppression and clinically acceptable gradient times. Herein, we present our preliminary findings on the evaluation of a deep learning optimized sequence using T1 weighted imaging. MATERIALS AND METHODS: Clinical and optimized Deep learning-based image reconstruction (DLBIR) T1 SPACE sequences were evaluated, comparing non-contrast sequences in ten healthy controls and post-contrast sequences in five consecutive patients. Images were reviewed on a Likert-like scale by four fellowship-trained neuroradiologists. Scores (range 1-4) were separately assigned for eleven vessel segments in terms of vessel wall and lumen delineation. Additionally, images were evaluated in terms of overall background noise, image sharpness and homogenous CSF signal. Segment-wise scores were compared using paired samples t-tests. RESULTS: The scan time for the clinical and DLBIR sequences were 7:26 minutes and 5:23 minutes respectively. DLBIR images showed consistently higher wall signal and lumen visualization scores, with the differences being statistically significant in the majority of vessel segments on both pre and post contrast images. DLBIR images had lower background noise, higher image sharpness and uniform CSF signal. Depiction of intracranial pathologies was better or similar on the DLBIR images. CONCLUSIONS: Our preliminary findings suggest that DLBIR optimized IC-VWI sequences may be helpful in achieving shorter gradient times with improved vessel wall visualization and overall image quality. These improvements may help with wider adoption of ICVWI in clinical practice and should be further validated on a larger cohort. ABBREVIATIONS: DL deep learning; VWI = vessel wall imaging.
- 18 June 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (11) , 1655-1660
Deep Learning–Based Reconstruction of 3D T1 SPACE Vessel Wall Imaging Provides Improved Image Quality with Reduced Scan Times: A Preliminary Study
BACKGROUND AND PURPOSE: Intra-cranial vessel wall imaging (IC-VWI) is technically challenging to implement, given the simultaneous requirements of high spatial resolution, excellent blood and CSF signal suppression and clinically acceptable gradient times. Herein, we present our preliminary findings on the evaluation of a deep learning optimized sequence using T1 weighted imaging. MATERIALS AND METHODS: Clinical and optimized Deep learning-based image reconstruction (DLBIR) T1 SPACE sequences were evaluated, comparing non-contrast sequences in ten healthy controls and post-contrast sequences in five consecutive patients. Images were reviewed on a Likert-like scale by four fellowship-trained neuroradiologists. Scores (range 1-4) were separately assigned for eleven vessel segments in terms of vessel wall and lumen delineation. Additionally, images were evaluated in terms of overall background noise, image sharpness and homogenous CSF signal. Segment-wise scores were compared using paired samples t-tests. RESULTS: The scan time for the clinical and DLBIR sequences were 7:26 minutes and 5:23 minutes respectively. DLBIR images showed consistently higher wall signal and lumen visualization scores, with the differences being statistically significant in the majority of vessel segments on both pre and post contrast images. DLBIR images had lower background noise, higher image sharpness and uniform CSF signal. Depiction of intracranial pathologies was better or similar on the DLBIR images. CONCLUSIONS: Our preliminary findings suggest that DLBIR optimized IC-VWI sequences may be helpful in achieving shorter gradient times with improved vessel wall visualization and overall image quality. These improvements may help with wider adoption of ICVWI in clinical practice and should be further validated on a larger cohort. ABBREVIATIONS: DL deep learning; VWI = vessel wall imaging.
- Open Access
Detection and Mitigation of Neurovascular Uncoupling in Brain Gliomas
Functional magnetic resonance imaging (fMRI) with blood oxygen level-dependent (BOLD) technique is useful for preoperative mapping of brain functional networks in tumor patients, providing reliable in vivo detection of eloquent cortex to help reduce the risk of postsurgical morbidity. BOLD task-based fMRI (tb-fMRI) is the most often used noninvasive method that can reliably map cortical networks, including those associated with sensorimotor, language, and visual functions. BOLD resting-state fMRI (rs-fMRI) is emerging as a promising ancillary tool for visualization of diverse functional networks. Although fMRI is a powerful tool that can be used as an adjunct for brain tumor surgery planning, it has some constraints that should be taken into consideration for proper clinical interpretation. BOLD fMRI interpretation may be limited by neurovascular uncoupling (NVU) induced by brain tumors. Cerebrovascular reactivity (CVR) mapping obtained using breath-hold methods is an effective method for evaluating NVU potential.
Open AccessDetection and Mitigation of Neurovascular Uncoupling in Brain Gliomas
Functional magnetic resonance imaging (fMRI) with blood oxygen level-dependent (BOLD) technique is useful for preoperative mapping of brain functional networks in tumor patients, providing reliable in vivo detection of eloquent cortex to help reduce the risk of postsurgical morbidity. BOLD task-based fMRI (tb-fMRI) is the most often used noninvasive method that can reliably map cortical networks, including those associated with sensorimotor, language, and visual functions. BOLD resting-state fMRI (rs-fMRI) is emerging as a promising ancillary tool for visualization of diverse functional networks. Although fMRI is a powerful tool that can be used as an adjunct for brain tumor surgery planning, it has some constraints that should be taken into consideration for proper clinical interpretation. BOLD fMRI interpretation may be limited by neurovascular uncoupling (NVU) induced by brain tumors. Cerebrovascular reactivity (CVR) mapping obtained using breath-hold methods is an effective method for evaluating NVU potential.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Benefits of echo combination for high-spatial-resolution ME resting state FMRI on a compact 3T scanner
For multi-echo EPI, the T2*-weighted echo combination (T2EC) is a commonly used pre-processing step to boost the data quality. We assessed the benefit of T2EC in high-spatial-resolution multi-echo fMRI with explained variances and functional connectivity detectability. The performance was evaluated and compared with single-echo EPI for resting state fMRI on a compact 3T scanner with high-performance gradients. It was shown that a large portion of unwanted signal variance was globally suppressed through T2EC. Multi-echo acquisition shows improved image intensity and enhanced functional sensitivity in brain regions affected by signal-dropout.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Benefits of echo combination for high-spatial-resolution ME resting state FMRI on a compact 3T scanner
For multi-echo EPI, the T2*-weighted echo combination (T2EC) is a commonly used pre-processing step to boost the data quality. We assessed the benefit of T2EC in high-spatial-resolution multi-echo fMRI with explained variances and functional connectivity detectability. The performance was evaluated and compared with single-echo EPI for resting state fMRI on a compact 3T scanner with high-performance gradients. It was shown that a large portion of unwanted signal variance was globally suppressed through T2EC. Multi-echo acquisition shows improved image intensity and enhanced functional sensitivity in brain regions affected by signal-dropout.
- 3 August 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (9) , 999-1001
Benign Enhancing Foramen Magnum Lesions
SUMMARY: Benign enhancing foramen magnum lesions have been previously described as T2-hyperintense small, enhancing lesions located posterior to the intradural vertebral artery. We present the first case with pathologic correlation. These lesions are fibrotic nodules adhering to the spinal accessory nerve. While they can enlarge with time on subsequent examinations, on the basis of the imaging characteristics and location, they do not necessitate surgical resection.
- 3 August 2023
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 44 (9) , 999-1001
Benign Enhancing Foramen Magnum Lesions
SUMMARY: Benign enhancing foramen magnum lesions have been previously described as T2-hyperintense small, enhancing lesions located posterior to the intradural vertebral artery. We present the first case with pathologic correlation. These lesions are fibrotic nodules adhering to the spinal accessory nerve. While they can enlarge with time on subsequent examinations, on the basis of the imaging characteristics and location, they do not necessitate surgical resection.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Improved Fidelity for Resting-State Connectivity Measurements in High-Spatial-Resolution ME-fMRI on a Compact 3T Scanner
Through echo-combination, multi-echo echo-planar-imaging (ME-EPI) has shown improved performance for fMRI over single-echo (SE)-EPI. The high-performance gradients on a compact 3T scanner enable whole-brain high-spatial-resolution ME-EPI with reasonable echo times and comparable TR to SE-EPI. To evaluate the fidelity of the ME-EPI sequence in resting state fMRI and compare with that of SE-EPI sequence, seed-based and ICA-based functional connectivity (FC) analyses were applied to evaluate scan-time-dependency and accuracy improvement. ME-EPI extracted more and stronger FCs in seed-based connectivity analysis and produced higher sensitivity and accuracy in ICA-based method, compared to SE-EPI.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Improved Fidelity for Resting-State Connectivity Measurements in High-Spatial-Resolution ME-fMRI on a Compact 3T Scanner
Through echo-combination, multi-echo echo-planar-imaging (ME-EPI) has shown improved performance for fMRI over single-echo (SE)-EPI. The high-performance gradients on a compact 3T scanner enable whole-brain high-spatial-resolution ME-EPI with reasonable echo times and comparable TR to SE-EPI. To evaluate the fidelity of the ME-EPI sequence in resting state fMRI and compare with that of SE-EPI sequence, seed-based and ICA-based functional connectivity (FC) analyses were applied to evaluate scan-time-dependency and accuracy improvement. ME-EPI extracted more and stronger FCs in seed-based connectivity analysis and produced higher sensitivity and accuracy in ICA-based method, compared to SE-EPI.
- Open Access
Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.
Open AccessImproved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.
- 2 January 2021
- Published by Springer Nature in Neuroradiology
- Vol. 63 (2) , 167-177
Clinical 7-T MRI for neuroradiology: strengths, weaknesses, and ongoing challenges
Since the relatively recent regulatory approval for clinical use in both Europe and North America, 7-Tesla (T) MRI has been adopted for clinical practice at our institution. Based on this experience, this article reviews the unique features of 7-T MRI neuroimaging and addresses the challenges of establishing a 7-T MRI clinical practice. The underlying fundamental physics principals of high-field strength MRI are briefly reviewed. Scanner installation, safety considerations, and artifact mitigation techniques are discussed. Seven-tesla MRI case examples of neurologic diseases including epilepsy, vascular abnormalities, and tumor imaging are presented to illustrate specific applications of 7-T MRI. The advantages of 7-T MRI in conjunction with advanced neuroimaging techniques such as functional MRI are presented. Seven-tesla MRI produces more detailed information and, in some cases, results in specific diagnoses where previous 3-T studies were insufficient. Still, persistent technical issues for 7-T scanning present ongoing challenges for radiologists.
- 2 January 2021
- Published by Springer Nature in Neuroradiology
- Vol. 63 (2) , 167-177
Clinical 7-T MRI for neuroradiology: strengths, weaknesses, and ongoing challenges
Since the relatively recent regulatory approval for clinical use in both Europe and North America, 7-Tesla (T) MRI has been adopted for clinical practice at our institution. Based on this experience, this article reviews the unique features of 7-T MRI neuroimaging and addresses the challenges of establishing a 7-T MRI clinical practice. The underlying fundamental physics principals of high-field strength MRI are briefly reviewed. Scanner installation, safety considerations, and artifact mitigation techniques are discussed. Seven-tesla MRI case examples of neurologic diseases including epilepsy, vascular abnormalities, and tumor imaging are presented to illustrate specific applications of 7-T MRI. The advantages of 7-T MRI in conjunction with advanced neuroimaging techniques such as functional MRI are presented. Seven-tesla MRI produces more detailed information and, in some cases, results in specific diagnoses where previous 3-T studies were insufficient. Still, persistent technical issues for 7-T scanning present ongoing challenges for radiologists.