Malte Storm
Malte Storm has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
Christoph Rau
Diamond Light Source, Harwell Science and Innovation Campus, Didcot, UK
4 shared publications- Alexandra Pacureanu
ESRF, The European Synchrotron, Grenoble, France
2 shared publications - Andreas T. Schaefer
The Francis Crick Institute
2 shared publications - Anne Bonnin
Paul Scherrer Institut, Swiss Light Source, Villigen PSI
2 shared publications - Berit Zeller-Plumhoff
Institute of Metallic Biomaterials, Helmholtz Zentrum Hereon, Geesthacht, Germany
2 shared publications C. Rau
2 shared publications
Latest Publications
- Open Access
- 16 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (4) , 1476-1485
Pydidas: a tool for automated X-ray diffraction data analysis
The processing and analysis of X-ray diffraction (XRD) data at synchrotrons is often left to the user groups, which limits the user base to groups with a background in analyzing XRD data. Pydidas is a new Python package for processing XRD data. It provides an easy and intuitive interface and versatile processing options with the aim of being accessible to non-experts in XRD analysis. A graphical user interface (GUI) allows users to perform the full pipeline of data browsing, experiment calibration, workflow setup, processing and visualization in a single tool. In addition, pydidas' logic is decoupled from the GUI and it can be fully used from within scripts or embedded into other processing pipelines. The pydidas processing pipeline is assembled from individual plugins which perform specific processing steps. This modular design allows for very versatile pipelines covering a wide range of applications. To improve the usability even further, custom plugins can be integrated in the pydidas workflow to allow specialized processing steps.
- 16 June 2025
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 58 (4) , 1476-1485
Open AccessPydidas: a tool for automated X-ray diffraction data analysis
The processing and analysis of X-ray diffraction (XRD) data at synchrotrons is often left to the user groups, which limits the user base to groups with a background in analyzing XRD data. Pydidas is a new Python package for processing XRD data. It provides an easy and intuitive interface and versatile processing options with the aim of being accessible to non-experts in XRD analysis. A graphical user interface (GUI) allows users to perform the full pipeline of data browsing, experiment calibration, workflow setup, processing and visualization in a single tool. In addition, pydidas' logic is decoupled from the GUI and it can be fully used from within scripts or embedded into other processing pipelines. The pydidas processing pipeline is assembled from individual plugins which perform specific processing steps. This modular design allows for very versatile pipelines covering a wide range of applications. To improve the usability even further, custom plugins can be integrated in the pydidas workflow to allow specialized processing steps.
- Open Access
- 1 November 2024
- Published by KEAI Publishing in Bioactive Materials
- Vol. 41, 657-671
Multi-modal investigation of the bone micro- and ultrastructure, and elemental distribution in the presence of Mg-xGd screws at mid-term healing stages
Magnesium (Mg) - based alloys are becoming attractive materials for medical applications as temporary bone implants for support of fracture healing, e.g. as a suture anchor. Due to their mechanical properties and biocompatibility, they may replace titanium or stainless-steel implants, commonly used in orthopedic field. Nevertheless, patient safety has to be assured by finding a long-term balance between metal degradation, osseointegration, bone ultrastructure adaptation and element distribution in organs. In order to determine the implant behavior and its influence on bone and tissues, we investigated two Mg alloys with gadolinium contents of 5 and 10 wt percent in comparison to permanent materials titanium and polyether ether ketone. The implants were present in rat tibia for 10, 20 and 32 weeks before sacrifice of the animal. Synchrotron radiation-based micro computed tomography enables the distinction of features like residual metal, degradation layer and bone structure. Additionally, X-ray diffraction and X-ray fluorescence yield information on parameters describing the bone ultrastructure and elemental composition at the bone-to-implant interface. Finally, with element specific mass spectrometry, the elements and their accumulation in the main organs and tissues are traced. The results show that Mg-xGd implants degrade in vivo under the formation of a stable degradation layer with bone remodeling similar to that of Ti after 10 weeks. No accumulation of Mg and Gd was observed in selected organs, except for the interfacial bone after 8 months of healing. Thus, we confirm that Mg-5Gd and Mg-10Gd are suitable material choices for bone implants.
- 1 November 2024
- Published by KEAI Publishing in Bioactive Materials
- Vol. 41, 657-671
Open AccessMulti-modal investigation of the bone micro- and ultrastructure, and elemental distribution in the presence of Mg-xGd screws at mid-term healing stages
Magnesium (Mg) - based alloys are becoming attractive materials for medical applications as temporary bone implants for support of fracture healing, e.g. as a suture anchor. Due to their mechanical properties and biocompatibility, they may replace titanium or stainless-steel implants, commonly used in orthopedic field. Nevertheless, patient safety has to be assured by finding a long-term balance between metal degradation, osseointegration, bone ultrastructure adaptation and element distribution in organs. In order to determine the implant behavior and its influence on bone and tissues, we investigated two Mg alloys with gadolinium contents of 5 and 10 wt percent in comparison to permanent materials titanium and polyether ether ketone. The implants were present in rat tibia for 10, 20 and 32 weeks before sacrifice of the animal. Synchrotron radiation-based micro computed tomography enables the distinction of features like residual metal, degradation layer and bone structure. Additionally, X-ray diffraction and X-ray fluorescence yield information on parameters describing the bone ultrastructure and elemental composition at the bone-to-implant interface. Finally, with element specific mass spectrometry, the elements and their accumulation in the main organs and tissues are traced. The results show that Mg-xGd implants degrade in vivo under the formation of a stable degradation layer with bone remodeling similar to that of Ti after 10 weeks. No accumulation of Mg and Gd was observed in selected organs, except for the interfacial bone after 8 months of healing. Thus, we confirm that Mg-5Gd and Mg-10Gd are suitable material choices for bone implants.
- Open Access
- 13 May 2024
- Published by Elsevier in Composites Part A: Applied Science and Manufacturing
- Vol. 184
The role of cavitation in the toughening of elastomer nanocomposites reinforced with graphene nanoplatelets
- 13 May 2024
- Published by Elsevier in Composites Part A: Applied Science and Manufacturing
- Vol. 184
Open AccessThe role of cavitation in the toughening of elastomer nanocomposites reinforced with graphene nanoplatelets
- Open Access
- 25 May 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-16
Functional and multiscale 3D structural investigation of brain tissue through correlative in vivo physiology, synchrotron microtomography and volume electron microscopy
Understanding the function of biological tissues requires a coordinated study of physiology and structure, exploring volumes that contain complete functional units at a detail that resolves the relevant features. Here, we introduce an approach to address this challenge: Mouse brain tissue sections containing a region where function was recorded using in vivo 2-photon calcium imaging were stained, dehydrated, resin-embedded and imaged with synchrotron X-ray computed tomography with propagation-based phase contrast (SXRT). SXRT provided context at subcellular detail, and could be followed by targeted acquisition of multiple volumes using serial block-face electron microscopy (SBEM). In the olfactory bulb, combining SXRT and SBEM enabled disambiguation of in vivo-assigned regions of interest. In the hippocampus, we found that superficial pyramidal neurons in CA1a displayed a larger density of spine apparati than deeper ones. Altogether, this approach can enable a functional and structural investigation of subcellular features in the context of cells and tissues.
- 25 May 2022
- Published by Springer Nature in Nature Communications
- Vol. 13 (1) , 1-16
Open AccessFunctional and multiscale 3D structural investigation of brain tissue through correlative in vivo physiology, synchrotron microtomography and volume electron microscopy
Understanding the function of biological tissues requires a coordinated study of physiology and structure, exploring volumes that contain complete functional units at a detail that resolves the relevant features. Here, we introduce an approach to address this challenge: Mouse brain tissue sections containing a region where function was recorded using in vivo 2-photon calcium imaging were stained, dehydrated, resin-embedded and imaged with synchrotron X-ray computed tomography with propagation-based phase contrast (SXRT). SXRT provided context at subcellular detail, and could be followed by targeted acquisition of multiple volumes using serial block-face electron microscopy (SBEM). In the olfactory bulb, combining SXRT and SBEM enabled disambiguation of in vivo-assigned regions of interest. In the hippocampus, we found that superficial pyramidal neurons in CA1a displayed a larger density of spine apparati than deeper ones. Altogether, this approach can enable a functional and structural investigation of subcellular features in the context of cells and tissues.
- Open Access
- 1 January 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (1) , 138-147
Optimizing the energy bandwidth for transmission full-field X-ray microscopy experiments
Full-field transmission X-ray microscopy (TXM) is a very potent high-resolution X-ray imaging technique. However, it is challenging to achieve fast acquisitions because of the limited efficiency of the optics. Using a broader energy bandwidth, for example using a multilayer monochromator, directly increases the flux in the experiment. The advantage of more counts needs to be weighed against a deterioration in achievable resolution because focusing optics show chromatic aberrations. This study presents theoretical considerations of how much the resolution is affected by an increase in bandwidth as well as measurements at different energy bandwidths (ΔE/E = 0.013%, 0.27%, 0.63%) and the impact on achievable resolution. It is shown that using a multilayer monochromator instead of a classical silicon double-crystal monochromator can increase the flux by an order of magnitude with only a limited effect on the resolution.
- 1 January 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (1) , 138-147
Open AccessOptimizing the energy bandwidth for transmission full-field X-ray microscopy experiments
Full-field transmission X-ray microscopy (TXM) is a very potent high-resolution X-ray imaging technique. However, it is challenging to achieve fast acquisitions because of the limited efficiency of the optics. Using a broader energy bandwidth, for example using a multilayer monochromator, directly increases the flux in the experiment. The advantage of more counts needs to be weighed against a deterioration in achievable resolution because focusing optics show chromatic aberrations. This study presents theoretical considerations of how much the resolution is affected by an increase in bandwidth as well as measurements at different energy bandwidths (ΔE/E = 0.013%, 0.27%, 0.63%) and the impact on achievable resolution. It is shown that using a multilayer monochromator instead of a classical silicon double-crystal monochromator can increase the flux by an order of magnitude with only a limited effect on the resolution.
- Open Access
- 1 December 2021
- Published by KEAI Publishing in Bioactive Materials
- Vol. 6 (12) , 4368-4376
Evaluating the morphology of the degradation layer of pure magnesium via 3D imaging at resolutions below 40 nm
Magnesium is attractive for the application as a temporary bone implant due to its inherent biodegradability, non-toxicity and suitable mechanical properties. The degradation process of magnesium in physiological environments is complex and is thought to be a diffusion-limited transport problem. We use a multi-scale imaging approach using micro computed tomography and transmission X-ray microscopy (TXM) at resolutions below 40 nm. Thus, we are able to evaluate the nanoporosity of the degradation layer and infer its impact on the degradation process of pure magnesium in two physiological solutions. Magnesium samples were degraded in simulated body fluid (SBF) or Dulbecco's modified Eagle's medium (DMEM) with 10% fetal bovine serum (FBS) for one to four weeks. TXM reveals the three-dimensional interconnected pore network within the degradation layer for both solutions. The pore network morphology and degradation layer composition are similar for all samples. By contrast, the degradation layer thickness in samples degraded in SBF was significantly higher and more inhomogeneous than in DMEM+10%FBS. Distinct features could be observed within the degradation layer of samples degraded in SBF, suggesting the formation of microgalvanic cells, which are not present in samples degraded in DMEM+10%FBS. The results suggest that the nanoporosity of the degradation layer and the resulting ion diffusion processes therein have a limited influence on the overall degradation process. This indicates that the influence of organic components on the dampening of the degradation rate by the suppression of microgalvanic degradation is much greater in the present study.
- 1 December 2021
- Published by KEAI Publishing in Bioactive Materials
- Vol. 6 (12) , 4368-4376
Open AccessEvaluating the morphology of the degradation layer of pure magnesium via 3D imaging at resolutions below 40 nm
Magnesium is attractive for the application as a temporary bone implant due to its inherent biodegradability, non-toxicity and suitable mechanical properties. The degradation process of magnesium in physiological environments is complex and is thought to be a diffusion-limited transport problem. We use a multi-scale imaging approach using micro computed tomography and transmission X-ray microscopy (TXM) at resolutions below 40 nm. Thus, we are able to evaluate the nanoporosity of the degradation layer and infer its impact on the degradation process of pure magnesium in two physiological solutions. Magnesium samples were degraded in simulated body fluid (SBF) or Dulbecco's modified Eagle's medium (DMEM) with 10% fetal bovine serum (FBS) for one to four weeks. TXM reveals the three-dimensional interconnected pore network within the degradation layer for both solutions. The pore network morphology and degradation layer composition are similar for all samples. By contrast, the degradation layer thickness in samples degraded in SBF was significantly higher and more inhomogeneous than in DMEM+10%FBS. Distinct features could be observed within the degradation layer of samples degraded in SBF, suggesting the formation of microgalvanic cells, which are not present in samples degraded in DMEM+10%FBS. The results suggest that the nanoporosity of the degradation layer and the resulting ion diffusion processes therein have a limited influence on the overall degradation process. This indicates that the influence of organic components on the dampening of the degradation rate by the suppression of microgalvanic degradation is much greater in the present study.
- Open Access
- 1 June 2021
- Published by Elsevier in Materials Today Communications
- Vol. 27
3D analysis of enamel demineralisation in human dental caries using high-resolution, large field of view synchrotron X-ray micro-computed tomography
- 1 June 2021
- Published by Elsevier in Materials Today Communications
- Vol. 27
Open Access3D analysis of enamel demineralisation in human dental caries using high-resolution, large field of view synchrotron X-ray micro-computed tomography
- 1 April 2021
- Published by Elsevier in Combustion and Flame
- Vol. 226, 478-489
4D micro-scale, phase-contrast X-ray imaging and computed tomography of HMX-based polymer-bonded explosives during thermal runaway
- 1 April 2021
- Published by Elsevier in Combustion and Flame
- Vol. 226, 478-489
4D micro-scale, phase-contrast X-ray imaging and computed tomography of HMX-based polymer-bonded explosives during thermal runaway
- Open Access
Functional and multiscale 3D structural investigation of brain tissue through correlative in vivo physiology, synchrotron micro-tomography and volume electron microscopy
Attributing in vivo neurophysiology to the brains’ ultrastructure requires a large field of view containing contextual anatomy. Electron microscopy (EM) is the gold standard technique to identify ultrastructure, yet acquiring volumes containing full mammalian neural circuits is challenging and time consuming using EM. Here, we show that synchrotron X-ray computed tomography (SXRT) provides rapid imaging of EM-prepared tissue volumes of several cubic millimetres. Resolution was sufficient for distinguishing cell bodies as well as for tracing apical dendrites in olfactory bulb and hippocampus, for up to 350 μm. Correlating EM with SXRT allowed us to associate dendritic spines on pyramidal cell apical dendrites in the stratum radiatum to their corresponding soma locations. Superficial pyramidal neurons had larger spine apparatus density compared to deeper ones, implying differential synaptic plasticity for superficial and deeper cells. Finally, we show that X-ray tomography and volume EM can be reliably correlated to prior in vivo imaging. Thus, combining functional measurements with multiscale X-ray microscopy and volume EM establishes a correlative workflow that enables functional and structural investigation of subcellular features in the context of cellular morphologies, tissues and ultimately whole organs.
Open AccessFunctional and multiscale 3D structural investigation of brain tissue through correlative in vivo physiology, synchrotron micro-tomography and volume electron microscopy
Attributing in vivo neurophysiology to the brains’ ultrastructure requires a large field of view containing contextual anatomy. Electron microscopy (EM) is the gold standard technique to identify ultrastructure, yet acquiring volumes containing full mammalian neural circuits is challenging and time consuming using EM. Here, we show that synchrotron X-ray computed tomography (SXRT) provides rapid imaging of EM-prepared tissue volumes of several cubic millimetres. Resolution was sufficient for distinguishing cell bodies as well as for tracing apical dendrites in olfactory bulb and hippocampus, for up to 350 μm. Correlating EM with SXRT allowed us to associate dendritic spines on pyramidal cell apical dendrites in the stratum radiatum to their corresponding soma locations. Superficial pyramidal neurons had larger spine apparatus density compared to deeper ones, implying differential synaptic plasticity for superficial and deeper cells. Finally, we show that X-ray tomography and volume EM can be reliably correlated to prior in vivo imaging. Thus, combining functional measurements with multiscale X-ray microscopy and volume EM establishes a correlative workflow that enables functional and structural investigation of subcellular features in the context of cellular morphologies, tissues and ultimately whole organs.
- Open Access
4D In-Situ Microscopy of Aerosol Filtration in a Wall Flow Filter
The transient nature of the internal pore structure of particulate wall flow filters, caused by the continuous deposition of particulate matter, makes studying their flow and filtration characteristics challenging. In this article we present a new methodology and first experimental demonstration of time resolved in-situ synchrotron micro X-ray computed tomography (micro-CT) to study aerosol filtration. We directly imaged in 4D (3D plus time) pore scale deposits of TiO nanoparticles (nominal mean primary diameter of 25 nm) with a pixel resolution of 1.6 m. We obtained 3D tomograms at a rate of ∼1 per minute. The combined spatial and temporal resolution allows us to observe pore blocking and filling phenomena as they occur in the filter’s pore space. We quantified the reduction in filter porosity over time, from an initial porosity of 0.60 to a final porosity of 0.56 after 20 min. Furthermore, the penetration depth of particulate deposits and filtration rate was quantified. This novel image-based method offers valuable and statistically relevant insights into how the pore structure and function evolves during particulate filtration. Our data set will allow validation of simulations of automotive wall flow filters. Evolutions of this experimental design have potential for the study of a wide range of dry aerosol filters and could be directly applied to catalysed automotive wall flow filters.Open Access4D In-Situ Microscopy of Aerosol Filtration in a Wall Flow Filter
The transient nature of the internal pore structure of particulate wall flow filters, caused by the continuous deposition of particulate matter, makes studying their flow and filtration characteristics challenging. In this article we present a new methodology and first experimental demonstration of time resolved in-situ synchrotron micro X-ray computed tomography (micro-CT) to study aerosol filtration. We directly imaged in 4D (3D plus time) pore scale deposits of TiO nanoparticles (nominal mean primary diameter of 25 nm) with a pixel resolution of 1.6 m. We obtained 3D tomograms at a rate of ∼1 per minute. The combined spatial and temporal resolution allows us to observe pore blocking and filling phenomena as they occur in the filter’s pore space. We quantified the reduction in filter porosity over time, from an initial porosity of 0.60 to a final porosity of 0.56 after 20 min. Furthermore, the penetration depth of particulate deposits and filtration rate was quantified. This novel image-based method offers valuable and statistically relevant insights into how the pore structure and function evolves during particulate filtration. Our data set will allow validation of simulations of automotive wall flow filters. Evolutions of this experimental design have potential for the study of a wide range of dry aerosol filters and could be directly applied to catalysed automotive wall flow filters.