Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luis Hector Quintero has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Temperature-Driven Formation and Consolidation of Magnetite-Type Nano-Assemblies in a PEI-Assisted Solvothermal System

    by Daniel Ramírez-De-Alba, José Antonio Pérez-Tavares, Pablo Eduardo Cardoso-Avila, Luis H. Quintero, Merced Martínez-Rosales, Jairo Francisco Juárez-Vera, Mario Eduardo Cano-González, Israel Águila-Martínez, Rita Patakfalvi

    Magnetite-type iron oxide nano-assemblies are widely investigated because of their strong magnetic response, chemical stability, and tunable surface chemistry. However, the lower-temperature threshold for crystalline spinel formation in polyethylenimine-assisted solvothermal systems remains insufficiently defined. In this work, an FeCl3·6H2O–ethylene glycol–sodium acetate–branched polyethylenimine system was systematically investigated between 150 and 200 °C to determine the onset of magnetite-type spinel formation and its associated physicochemical evolution. Rietveld refinement identified the crystalline fraction of the product synthesized at 150 °C as 60.1 wt.% hematite and 39.9 wt.% goethite, whereas the materials obtained at 160–200 °C were satisfactorily described using a cubic Fd3¯m magnetite-type spinel model. This structural transformation was accompanied by an abrupt increase in saturation magnetization from 0.806 emu g–1 at 150 °C to 62.86 emu g−1 at 160 °C, reaching 79.99 emu g−1 at 200 °C. Temperature-dependent zero-field-cooled and field-cooled magnetization (ZFC–FC) measurements revealed an anomaly within 99–104 K, with a representative derivative maximum near 101 K, assigned to a Verwey-type transition and supporting the presence of magnetite-containing domains. Brunauer–Emmett–Teller surface-area (BET) analysis, thermogravimetric analysis (TGA), scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS) revealed a concurrent consolidation process involving goethite dehydroxylation, progressive removal or transformation of organic species, reduction in accessible surface area, and the emergence of spherical nano-assemblies from 160 °C onward. Additional PEI-free control syntheses at 160, 180, and 200 °C showed that a well-developed cubic spinel diffraction pattern was not obtained at 160 °C in the absence of PEI, whereas clear spinel reflections emerged at 180 and 200 °C. These results identify 160 °C as the lowest tested temperature for reproducible magnetite-type spinel formation under the investigated PEI-assisted solvothermal conditions and demonstrate that phase transformation, ferrimagnetic ordering, and nano-assembly consolidation are closely coupled.

  • Open Access

    Magnetic Properties of Commercial Cornflakes

    by Francisco A. Cholico, Aldo A. Orozco, Luis H. Quintero, Peter Knauth, Zaira López, José A. Paz, Celso A. Velásquez, Jose de Jesús Bernal, Mario E. Cano

    This study reports on the magnetic properties of commercial cornflakes, which are primarily influenced by the iron content. An initial analysis of X-ray fluorescence on a brand of cornflakes evidenced the presence of a high concentration of Cl and up to 10.9 mg/100 g of Fe. After the extraction of iron from the cornflakes of two different brands, as iron filings, X-ray diffraction measurements indicate the presence of crystals of elemental iron, and no traces of other crystals of iron-derived compounds were found. The Fourier Transform Infrared analysis on the iron filings does not show any binding between iron and oxygen, which further discards the presence of iron oxides. The magnetic hysteresis loops of whole powdered cornflakes exhibit weak Langevin-like magnetizations, which principally correspond to the iron used as a fortification element. The diamagnetic behavior of the higher organic material content significantly attenuates this magnetic response. The hysteresis loops of the iron filings reached magnetic saturations 1% and 5% lower than those of a pure iron sample. Additionally, the indirect measurement of magnetic susceptibility of the iron filings by magneto-thermograms revealed only one Curie transition very close to 771 °C, which corresponds to pure elemental iron.

  • Sustainable Synthesis of Magnetic PolyHIPE Nanocomposites Using a Menthol-Based Deep Eutectic Solvent for Efficient Fenton Catalytic Dye Degradation

    by Carolina L. Recio-Colmenares, Daniela Ortiz-Ríos, Fernando Espinola-Portilla, Luis Héctor Quintero Hernández, Sergio Gómez-Salazar, Josué D. Mota-Morales, J. Félix Armando Soltero, José B. Pelayo-Vázquez, María G. Pérez-García

    This work presents a sustainable approach for synthesizing magnetic macroporous nanocomposites (NCs) via Pickering-type high-internal phase emulsions (HIPEs) using a deep eutectic solvent (DES) composed of d,l-menthol/acetic acid (MA, 1:1 molar ratio) as a green alternative to traditional organic solvents for the internal phase. The DES-in-water HIPEs were formulated with acrylamide/N,N'-methylenebis(acrylamide) (AAm:BAAm, 10:1 molar ratio) as the continuous phase and stabilized by a synergistic combination of the Pluronic F127 surfactant and magnetite nanoparticles (MNPs). HIPEs formulated with tetradecane as the internal phase were comparatively studied. The resulting materials exhibited an interconnected macroporous structure with embedded MNPs, enhancing their performance as heterogeneous Fenton catalysts. Magnetic polyHIPE NCs synthesized using MA DES demonstrated outstanding dye degradation efficiency within an 8 h reaction time, achieving removal rates of approximately 98.2% for methyl orange, 97.1% for neutral red, 98.5% for gentian violet, and 92.3% for a complex dye mixture. These materials demonstrated successful reuse across 10 cycles, with performance directly correlated to their specific surface area (SBET) and MNP content. In contrast, materials synthesized with tetradecane displayed significantly lower dye degradation efficiency (ca. 80.7% for gentian violet) due to a substantial reduction in SBET (19.84 and 7.14 m2/g for polyHIPEs synthesized using MA DES and tetradecane, respectively). These findings underscore the potential of hydrophobic DESs as sustainable media for developing advanced macroporous nanocomposites for environmental remediation, particularly in degrading organic pollutants from wastewater.


  • Open Access

    Comparing the Pressure on the Carpal Tunnel When Using an Ergonomic Pointer Driver and an Optical Alternative

    by Francisco A. Cholico, José A. Paz, Zaira López, Alfonso Hernández Sámano, Eri Mena-Barboza, José Bernal-Alvarado, Celso Velasquez, Rodolfo Hernández-Gutiérrez, Luis H. Quintero, Mario E. Cano

    Objectives: The objective of this paper is to introduce a method to measure the force or pressure over the carpal tunnel indirectly, using a new device to drive the pointer of a computer system. The measurements were compared with those obtained using an ergonomic mouse. Simultaneously, measurements of muscular stress on the digitorum extensor muscle were performed to correlate the applied force against muscle activity. Methods: An experimental setup was constructed using an infrared static receiver plus two wearable moving light emitters, which can be displaced inside a rectangular projected region. The pointer functions are performed through two finger gestures, while the hand is naturally extended. A microcontroller was used to communicate with the computer, which works as a human interface device and possesses firmware to associate the position of each light source with the pointer functions. Meanwhile, force and electromyography sensing circuits were developed to transmit and measure carpal tunnel strength and muscular stress. The system was tested on five healthy volunteers, who were encouraged to solve the same computational tasks using this new device and a trademark ergonomic mouse. Results: Our results show great differences (greater than one magnitude) between the efforts of the same volunteers performing the same predefined tasks using both pointer controllers. Only when the new device was used did the Pearson’s correlation coefficients show a higher correlation between the effort measured on the carpal tunnel and the muscular activity. Conclusions: The optic pointer driver diminishes the strength on the carpal tunnel, causing slightly increased stress on the digitorum extensor muscle.


  • Open Access

    The Fluorescent Cell Line SW620-GFP Is a Valuable Model to Monitor Magnetic Hyperthermia

    by Saray Rosales, Rodolfo Hernández-Gutiérrez, Alma Oaxaca, Zaira López, Norberto Casillas, Peter Knauth, Luis H. Quintero, José A. Paz, Francisco Cholico, Celso Velásquez, et al.

    In this work, the cell line SW620-GFP has been used in a complete magnetic hyperthermia assay, from the preparation of the ferrofluid with folate-coated iron oxide nanoparticles to in vivo experiments. The physical and chemical characterization of the nanoparticles evidenced their superparamagnetic behaviour, an average diameter of 12 ± 4 nm, a 2 nm coat thickness, and a high-power loss density. The main innovation of the work is the exclusive capability of viable SW620-GFP cells to emit fluorescence, enabling fast analysis of both, cell viability in vitro with an epifluorescence microscope and tumour size and shape in vivo in a non-invasive manner using the iBox technology. Moreover, with this imaging technique, it was possible to demonstrate the successful tumour size reduction in mice applying magnetic hyperthermia three times a week over 3 weeks.


  • Open Access

    Tetrahydroxyquinone: A Suitable Coating for Ferrofluids Used in Magnetic Hyperthermia

    by Ana G. González, Norberto Casillas, Zaira López, Oscar Cervantes, Peter Knauth, Rodolfo Hernández-Gutiérrez, Antonio Topete-Camacho, Saray Rosales, Luis H. Quintero, José A. Paz, et al.

    In this work, tetrahydroxyquinone (THQ) was used for the first time to coat iron oxide nanoparticles (IONPs) and to carry out in vitro experiments in magnetic hyperthermia. Synthesis by co-precipitation resulted in spherical IONPs with a core diameter of 13 ± 3 nm and covered by a 0.5 nm thick coat of THQ, which provided them with a reasonably good zeta potential of ζ = −28 ± 2 mV at pH = 7.3, and thus colloidal stability. The magnetic properties of the THQ-coated IONPs are promising: the low coercive field of Hc = 7 Oe, the high magnetic saturation of Ms = 70.5 emu/g and the low blocking temperature of Tb = 273 K indicate superparamagnetic characteristics at room temperature. Additionally, a high specific absorption rate SAR = 135 W/g (at 300 Oe and 530 kHz) was determined. Cell biological experiments using the human cell line HT-29 evidenced negligible cytotoxicity up to 2 mg/mL. Magnetic hyperthermia (MHT) assays demonstrated fast and reliable heating and reduced the metabolic activity of the cells to 42% upon reaching 42 °C within 15 min. The production of ROS by THQ-coated IONPs could not be detected, which may indicate a reduction in the undesired side effects caused by oxidative stress. Considering these good physicochemical and cell biological properties, this ferrofluid is a promising candidate for the initiation of in vivo experiments for cancer treatment by MHT in murine models.


  • Open Access

    Analysis of the nagnetic properties of core-shell iron oxide nanoparticles

    by Francisco Apolinar Cholico Hernández, Alfonso Hernández Sámano, Ramón Castañeda Priego, José Ávila Paz, Luis Héctor Quintero Hernández, Mario Eduardo Cano González

    We report on the magnetization of core-shells nanoparticles. Magnetic nanoparticles with a core of magnetite of 13 nm diameter covered with a shell of dopamine (1.1 nm thickness) are studied through vibrating sample magnetometer (VSM), Monte Carlo (MC) computer simulations, and analytical equations. All parameters involved in the theoretical analysis are experimentally determined, namely, the magnetic moment, temperature, magnetic field, core diameter, shell thickness, magnetic anisotropy, and particle concentration. The dependence of the magnetization with the magnetic field obtained through VSM and MC shows a 1% discrepancy in the magnetic saturation and up to 40% in the initial magnetic susceptibility. However, the dependence of the magnetization with the temperature obtained by MC indicates that the MNPs obey the Curie law above a critical temperature of 100 K, and dipolar interactions play an important role in the interval 20 < T < 100 K. That critical temperature is very close to the blocking temperature measured following the zero-field-cooled and zero-cooled protocols, where the dipolar interactions between MNPs become significant. Further analysis shows a Langevin-like behavior for both experimental and theoretical magnetizations.


  • Open Access

    A Ferrofluid with High Specific Absorption Rate Prepared in a Single Step Using a Biopolymer

    by Dulce A. Guzmán-Rocha, Teodoro Córdova-Fraga, José J. Bernal-Alvarado, Zaira López, Francisco A. Cholico, Luis H. Quintero, José A. Paz, Mario E. Cano

    An exhaustive characterization of the physicochemical properties of gum arabic (GA)-coated Fe3O4 magnetic nanoparticles was conducted in this work. These nanoparticles were obtained via the in-situ coprecipitation method (a fast single-step method) in two GA:Fe ratios, 10:1 and 20:1, respectively. Several experimental techniques were applied in the characterization process, all of them described below. Using Transmission Electron Microcopy images, they were shown to have spherical-like morphology with 11 nm diameter. The Fourier Transform Infrared spectra confirmed the attachment of the GA on the surface of the magnetic nanoparticles (MNPs), providing good colloidal stability from pH 7 to 8. The thickness of the coatings (1.7 nm and 1.1 nm) was determined using thermogravimetric measurements. A high specific absorption rate and superparamagnetic properties were determined using alternant and static magnetic fields, respectively. The GA-coated MNPs were non-cytotoxic, according to tests on HT-29 human intestine cells. Additionally, HT-29 cells were exposed to magnetic fluid hyperthermia at 530 kHz, and the induction of cell death by the magnetic field, due to the heating of GA-coated MNP, was observed.


  • Open Access

    A Ferrofluid with Surface Modified Nanoparticles for Magnetic Hyperthermia and High ROS Production

    by Oscar Cervantes, Zaira del Rocio Lopez, Norberto Casillas, Peter Knauth, Nayeli Checa, Francisco Apolinar Cholico, Rodolfo Hernandez-Gutiérrez, Luis Hector Quintero, Jose Avila Paz, Mario Eduardo Cano

    A ferrofluid with 1,2-Benzenediol-coated iron oxide nanoparticles was synthesized and physicochemically analyzed. This colloidal system was prepared following the typical co-precipitation method, and superparamagnetic nanoparticles of 13.5 nm average diameter, 34 emu/g of magnetic saturation, and 285 K of blocking temperature were obtained. Additionally, the zeta potential showed a suitable colloidal stability for cancer therapy assays and the magneto-calorimetric trails determined a high power absorption density. In addition, the oxidative capability of the ferrofluid was corroborated by performing the Fenton reaction with methylene blue (MB) dissolved in water, where the ferrofluid was suitable for producing reactive oxygen species (ROS), and surprisingly a strong degradation of MB was also observed when it was combined with H2O2. The intracellular ROS production was qualitatively corroborated using the HT-29 human cell line, by detecting the fluorescent rise induced in 2,7-dichlorofluorescein diacetate. In other experiments, cell metabolic activity was measured, and no toxicity was observed, even with concentrations of up to 4 mg/mL of magnetic nanoparticles (MNPs). When the cells were treated with magnetic hyperthermia, 80% of cells were dead at 43 °C using 3 mg/mL of MNPs and applying a magnetic field of 530 kHz with 20 kA/m amplitude.


  • Open Access

    A dynamic hysteresis meter for studying ferrofluids designed for magnetic hyperthermia

    by Alfonso Hernández Sámano, S Rosales, E E Mazon, Norberto Casillas, Antonio Topete, J A Paz, Luis Quintero, J C Estrada, M E Cano, Saray Rosales De Los Santos, et al.

    An AC magnetometer system is developed to determine the specific absorption rate (SAR) of ferrofluids designed to work in the range of interest for magnetic hyperthermia. The experimental setup contains a set of configurable RL coil sensors (resistance plus inductance) to obtain the inner area of the dynamic hysteresis loops of colloidal dispersions, which are stimulated using a multi-range alternating magnetic field generator. This magnetometer is suitable for covering the frequency band of 100–450 kHz, and special considerations concerning sample size and placement inside the magnetic field region are taken into account. The performance of the system is tested using a ferrofluid of water-dispersed iron oxide nanoparticles. The SAR determined with the developed system is compared with that obtained using the typical calorimetric procedure. The observations are consistent with both kinds of measurement, and also coincide with the results for other previously reported experimental systems.