Ahmed F. Abdou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ahmed F. Abdou has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
E. E. El-Kholy
Department of Electrical Engineering, Faculty of Engineering, Menoufia University, Shebin El-kom, 32511, Egypt
6 shared publications- Hany A. Hamed
Department of Electrical and Automation Engineering, Emirates Steel, Abu Dhabi, United Arab Emirates
3 shared publications - Hemanshu Roy Pota
University of New South Wales
3 shared publications - Ahmed Abu-Siada
Curtin University, Perth, WA, Australia
2 shared publications - Ehab Hassan Eid Bayoumi
Mechatronics and Robotics Section, Mechanical Engineering Department, Faculty of Engineering, The British University in Egypt, El Sherouk City, Suez Desert Road, Cairo 11837, Egypt
2 shared publications - Mohamed Shawky El Moursi
Department of Electrical Engineering, Advanced Power and Energy Center, Khalifa University, Abu Dhabi, UAE
2 shared publications
Latest Publications
- Open Access
- 10 September 2020
- Published by Springer Nature in Journal of Electrical Systems and Information Technology
- Vol. 7 (1) , 1-14
A flexible model for studying fringe field effect on parallel plate actuators
Electrostatic parallel plate actuators are common in micro-electro-mechanical systems due to their compatibility with micro-fabrication technology. Parallel plate actuators suffer from an instability problem called the pull-in phenomenon that happens when the applied DC voltage exceeds a certain value called the static pull-in voltage. The value of this critical voltage is important in many applications that depend on parallel plate actuators such as switches and static gas sensors. The fringe field around the edges of the plates could severely affect the performance of the actuator. This paper introduces a new model for the parallel plate actuator to calculate the value of static pull-in voltage. The proposed model considers the fringe field between the two plates. The static pull-in voltage of some PolyMUMPs actuators is practically measured and compared to the simulation results that involve the fringe field effect. The model is simulated using MATLAB to show the influence of that field on the static pull-in voltage. The MATLAB results of the proposed model are validated with ANSYS.
- 10 September 2020
- Published by Springer Nature in Journal of Electrical Systems and Information Technology
- Vol. 7 (1) , 1-14
Open AccessA flexible model for studying fringe field effect on parallel plate actuators
Electrostatic parallel plate actuators are common in micro-electro-mechanical systems due to their compatibility with micro-fabrication technology. Parallel plate actuators suffer from an instability problem called the pull-in phenomenon that happens when the applied DC voltage exceeds a certain value called the static pull-in voltage. The value of this critical voltage is important in many applications that depend on parallel plate actuators such as switches and static gas sensors. The fringe field around the edges of the plates could severely affect the performance of the actuator. This paper introduces a new model for the parallel plate actuator to calculate the value of static pull-in voltage. The proposed model considers the fringe field between the two plates. The static pull-in voltage of some PolyMUMPs actuators is practically measured and compared to the simulation results that involve the fringe field effect. The model is simulated using MATLAB to show the influence of that field on the static pull-in voltage. The MATLAB results of the proposed model are validated with ANSYS.
- Open Access
- 2 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 747
Stability Analysis of Grid-Connected Photovoltaic Systems with Dynamic Phasor Model
The typical layout of power systems is experiencing significant change, due to the high penetration of renewable energy sources (RESs). The ongoing evaluation of power systems is expecting more detailed and accurate mathematical modeling approaches for RESs which are dominated by power electronics. Although modeling techniques based on state–space averaging (SSA) have traditionally been used to mathematically represent the dynamics of power systems, the performance of such a model-based system degrades under high switching frequency. The multi-frequency averaging (MFA)-based higher-index dynamic phasor modeling tool is proposed in this paper, which is entirely new and can provide better estimations of dynamics. Dynamic stability analysis is presented in this paper for the MFA-based higher-index dynamical model of single-stage single-phase (SSSP) grid-connected photovoltaic (PV) systems under different switching frequencies.
- 2 July 2019
- Published by MDPI AG in Electronics
- Vol. 8 (7) , 747
Open AccessStability Analysis of Grid-Connected Photovoltaic Systems with Dynamic Phasor Model
The typical layout of power systems is experiencing significant change, due to the high penetration of renewable energy sources (RESs). The ongoing evaluation of power systems is expecting more detailed and accurate mathematical modeling approaches for RESs which are dominated by power electronics. Although modeling techniques based on state–space averaging (SSA) have traditionally been used to mathematically represent the dynamics of power systems, the performance of such a model-based system degrades under high switching frequency. The multi-frequency averaging (MFA)-based higher-index dynamic phasor modeling tool is proposed in this paper, which is entirely new and can provide better estimations of dynamics. Dynamic stability analysis is presented in this paper for the MFA-based higher-index dynamical model of single-stage single-phase (SSSP) grid-connected photovoltaic (PV) systems under different switching frequencies.
- Open Access
- 5 November 2018
- Published by MDPI AG in Electronics
- Vol. 7 (11) , 298
Solid State Transformers Topologies, Controllers, and Applications: State-of-the-Art Literature Review
With the global trend to produce clean electrical energy, the penetration of renewable energy sources in existing electricity infrastructure is expected to increase significantly within the next few years. The solid state transformer (SST) is expected to play an essential role in future smart grid topologies. Unlike traditional magnetic transformer, SST is flexible enough to be of modular construction, enabling bi-directional power flow and can be employed for AC and DC grids. Moreover, SSTs can control the voltage level and modulate both active and reactive power at the point of common coupling without the need to external flexible AC transmission system device as per the current practice in conventional electricity grids. The rapid advancement in power semiconductors switching speed and power handling capacity will soon allow for the commercialisation of grid-rated SSTs. This paper is aimed at introducing a state-of-the-art review for SST proposed topologies, controllers, and applications. Additionally, strengths, weaknesses, opportunities, and threats (SWOT) analysis along with a brief review of market drivers for prospective commercialisation are elaborated.
- 5 November 2018
- Published by MDPI AG in Electronics
- Vol. 7 (11) , 298
Open AccessSolid State Transformers Topologies, Controllers, and Applications: State-of-the-Art Literature Review
With the global trend to produce clean electrical energy, the penetration of renewable energy sources in existing electricity infrastructure is expected to increase significantly within the next few years. The solid state transformer (SST) is expected to play an essential role in future smart grid topologies. Unlike traditional magnetic transformer, SST is flexible enough to be of modular construction, enabling bi-directional power flow and can be employed for AC and DC grids. Moreover, SSTs can control the voltage level and modulate both active and reactive power at the point of common coupling without the need to external flexible AC transmission system device as per the current practice in conventional electricity grids. The rapid advancement in power semiconductors switching speed and power handling capacity will soon allow for the commercialisation of grid-rated SSTs. This paper is aimed at introducing a state-of-the-art review for SST proposed topologies, controllers, and applications. Additionally, strengths, weaknesses, opportunities, and threats (SWOT) analysis along with a brief review of market drivers for prospective commercialisation are elaborated.
- Open Access
- 11 September 2018
- Published by MDPI AG in Inventions
- Vol. 3 (3) , 66
Cyber Physical Energy Systems Modules for Power Sharing Controllers in Inverter Based Microgrids
The Microgrids (MGs) are an effective way to deal with the smart grid challenges, including service continuity in the event of a grid interruption, and renewable energy integration. The MGs are compounded by multiple distributed generators (DGs), and the main control goals are load demand sharing and voltage and frequency stability. Important research has been reported to cope with the implementation challenges of the MGs including the power sharing control problem, where the use of cybernetic components such as virtual components, and communication systems is a common characteristic. The use of these cybernetic components to control complex physical systems generates new modeling challenges in order to achieve an adequate balance between complexity and accuracy in the MG model. The standardization problem of the cyber-physical MG models is addressed in this work, using a cyber-physical energy systems (CPES) modeling methodology to build integrated modules, and define the communication architectures that each power sharing control strategy requires in an AC-MG. Based on these modules, the control designer can identify the signals and components that eventually require a time delay analysis, communication requirements evaluation, and cyber-attacks’ prevention strategies. Similarly, the modules of each strategy allow for analyzing the potential advantages and drawbacks of each power sharing control technique from a cyber physical perspective.
- 11 September 2018
- Published by MDPI AG in Inventions
- Vol. 3 (3) , 66
Open AccessCyber Physical Energy Systems Modules for Power Sharing Controllers in Inverter Based Microgrids
The Microgrids (MGs) are an effective way to deal with the smart grid challenges, including service continuity in the event of a grid interruption, and renewable energy integration. The MGs are compounded by multiple distributed generators (DGs), and the main control goals are load demand sharing and voltage and frequency stability. Important research has been reported to cope with the implementation challenges of the MGs including the power sharing control problem, where the use of cybernetic components such as virtual components, and communication systems is a common characteristic. The use of these cybernetic components to control complex physical systems generates new modeling challenges in order to achieve an adequate balance between complexity and accuracy in the MG model. The standardization problem of the cyber-physical MG models is addressed in this work, using a cyber-physical energy systems (CPES) modeling methodology to build integrated modules, and define the communication architectures that each power sharing control strategy requires in an AC-MG. Based on these modules, the control designer can identify the signals and components that eventually require a time delay analysis, communication requirements evaluation, and cyber-attacks’ prevention strategies. Similarly, the modules of each strategy allow for analyzing the potential advantages and drawbacks of each power sharing control technique from a cyber physical perspective.
- 3 July 2018
- Published by Taylor & Francis in Australian Journal of Electrical and Electronics Engineering
- Vol. 15 (3) , 131-143
SBO-based selective harmonic elimination for nine levels asymmetrical cascaded H-bridge multilevel inverter
The number of bridges, gate drive circuits and dc sources decrease by using asymmetrical is used to solve SHE equations to get the optimal switching angles. Genetic algorithm (GA) is also used to solve these equations to make comparison between Satin bowerbird optimisation (SBO) and GA algorithms. Matlab/Simulink software tool is used to carry out the simulation construction multilevel inverter. The selective harmonic elimination pulse width modulation (SHE-PWM) and sinusoidal pulse width modulation (SPWM) are carried out for a nine levels cascaded H-bridge (CHB) inverter with asymmetrical construction. Comparison between SHE and SPWM is done to get the benefit of SHE over SPWM. The elimination of some lower order harmonics and satisfy fundamental component in output voltage are the major purpose of SHE-PWM. The solving of the non-linear transcendental equations of SHE is the challenge to find out the switching angles, SBO technique.
- 3 July 2018
- Published by Taylor & Francis in Australian Journal of Electrical and Electronics Engineering
- Vol. 15 (3) , 131-143
SBO-based selective harmonic elimination for nine levels asymmetrical cascaded H-bridge multilevel inverter
The number of bridges, gate drive circuits and dc sources decrease by using asymmetrical is used to solve SHE equations to get the optimal switching angles. Genetic algorithm (GA) is also used to solve these equations to make comparison between Satin bowerbird optimisation (SBO) and GA algorithms. Matlab/Simulink software tool is used to carry out the simulation construction multilevel inverter. The selective harmonic elimination pulse width modulation (SHE-PWM) and sinusoidal pulse width modulation (SPWM) are carried out for a nine levels cascaded H-bridge (CHB) inverter with asymmetrical construction. Comparison between SHE and SPWM is done to get the benefit of SHE over SPWM. The elimination of some lower order harmonics and satisfy fundamental component in output voltage are the major purpose of SHE-PWM. The solving of the non-linear transcendental equations of SHE is the challenge to find out the switching angles, SBO technique.
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (3) , 1086-1097
A Novel Dynamic Switching Table Based Direct Power Control Strategy for Grid Connected Converters
Direct power control (DPC) has gained much attention for medium-voltage applications due to its fast power control capability. However, a conventional static switching table based DPC can lead to unsatisfactory response when the converter is connected to an electric grid because it is commonly designed assuming ideal and constant voltages of the grid and the dc link. Therefore, the actual grid voltage and the actual converter dc-link voltage should be considered while designing the switching table. This paper proposes a novel dynamic switching table for the DPC, considering actual grid and dc-link voltages variation. The proposed dynamic switching table incorporates a new definition of power influence crossover angles of each converter space vector. The proposed scheme dynamically adapts the switching table by feeding forward the actual grid and dc-link voltages, and hence the converter's power is precisely controlled. The proposed technique is verified for the three-level neutral point clamped converters connected to a standard IEEE 9-bus test system. Moreover, the real-time simulations are performed in a real-time digital simulator, OPAL-RT. The obtained results verified the effectiveness of the proposed DPC strategy under different grid fault scenarios.
- 23 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (3) , 1086-1097
A Novel Dynamic Switching Table Based Direct Power Control Strategy for Grid Connected Converters
Direct power control (DPC) has gained much attention for medium-voltage applications due to its fast power control capability. However, a conventional static switching table based DPC can lead to unsatisfactory response when the converter is connected to an electric grid because it is commonly designed assuming ideal and constant voltages of the grid and the dc link. Therefore, the actual grid voltage and the actual converter dc-link voltage should be considered while designing the switching table. This paper proposes a novel dynamic switching table for the DPC, considering actual grid and dc-link voltages variation. The proposed dynamic switching table incorporates a new definition of power influence crossover angles of each converter space vector. The proposed scheme dynamically adapts the switching table by feeding forward the actual grid and dc-link voltages, and hence the converter's power is precisely controlled. The proposed technique is verified for the three-level neutral point clamped converters connected to a standard IEEE 9-bus test system. Moreover, the real-time simulations are performed in a real-time digital simulator, OPAL-RT. The obtained results verified the effectiveness of the proposed DPC strategy under different grid fault scenarios.
- 19 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 65 (4) , 3056-3068
A Fast Recovery Technique for Grid-Connected Converters After Short Dips Using a Hybrid Structure PLL
Repeated faults in an industrial grid have affected a steel manufacturing plant and resulted in frequent tripping of all medium voltage converters. The reason for the trips was a synchronization fault due to a severe short duration voltage dip. Converters need a relatively long time to resume its normal operation after dip recovery due to the capacitors precharging process. If the capacitor's discharging is prevented, the converter can resume its normal operation after being synchronized. The synchronization process is performed by a phase locked loop type SRF-PLL with a very low bandwidth and low-pass in-loop filter, which delays the recovery process. In this paper, a solution for the aforementioned trip is presented by proposing two different synchronization hybrid schemes. The first scheme is assuming the converter already lost the synchronization, and a ride-through sequence is implemented to prevent the capacitor from discharging. The second scheme is proposed to prevent the synchronization fault and to recover the converter quickly after dip ends. Both schemes are implemented using a single-input fuzzy logic controller to obtain a very fast response. The performance of the proposed schemes is validated through simulation and a prototype experimental setup.
- 19 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 65 (4) , 3056-3068
A Fast Recovery Technique for Grid-Connected Converters After Short Dips Using a Hybrid Structure PLL
Repeated faults in an industrial grid have affected a steel manufacturing plant and resulted in frequent tripping of all medium voltage converters. The reason for the trips was a synchronization fault due to a severe short duration voltage dip. Converters need a relatively long time to resume its normal operation after dip recovery due to the capacitors precharging process. If the capacitor's discharging is prevented, the converter can resume its normal operation after being synchronized. The synchronization process is performed by a phase locked loop type SRF-PLL with a very low bandwidth and low-pass in-loop filter, which delays the recovery process. In this paper, a solution for the aforementioned trip is presented by proposing two different synchronization hybrid schemes. The first scheme is assuming the converter already lost the synchronization, and a ride-through sequence is implemented to prevent the capacitor from discharging. The second scheme is proposed to prevent the synchronization fault and to recover the converter quickly after dip ends. Both schemes are implemented using a single-input fuzzy logic controller to obtain a very fast response. The performance of the proposed schemes is validated through simulation and a prototype experimental setup.
- 24 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (3) , 1902-1906
A Modified DPC Switching Technique Based on Optimal Transition Route for of 3L-NPC Converters
This letter presents a modified switching technique for a three-level neutral-point-clamped converters controlled by direct power control (DPC). The proposed switching technique avoids the hard state transition of each phase module as well as reduces the overall switching frequency. For any phase module, it inserts sequence of vectors to avoid the direct transition from positive to negative state and vice versa. The proposed vector sequence is called optimal transition route (OTR). The OTR technique optimizes the route between the present and the next requested vector to avoid the hard transition of any module. The proposed technique not only avoids the risk of damaging the semiconductor switches, but also minimizes the switching frequency resulted in reducing the switching losses. As a result, the reliability and the overall efficiency of the converter is increased. The obtained results confirm its applicability for medium- and high-power grid-connected converters controlled by the DPC method.
- 24 August 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (3) , 1902-1906
A Modified DPC Switching Technique Based on Optimal Transition Route for of 3L-NPC Converters
This letter presents a modified switching technique for a three-level neutral-point-clamped converters controlled by direct power control (DPC). The proposed switching technique avoids the hard state transition of each phase module as well as reduces the overall switching frequency. For any phase module, it inserts sequence of vectors to avoid the direct transition from positive to negative state and vice versa. The proposed vector sequence is called optimal transition route (OTR). The OTR technique optimizes the route between the present and the next requested vector to avoid the hard transition of any module. The proposed technique not only avoids the risk of damaging the semiconductor switches, but also minimizes the switching frequency resulted in reducing the switching losses. As a result, the reliability and the overall efficiency of the converter is increased. The obtained results confirm its applicability for medium- and high-power grid-connected converters controlled by the DPC method.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (4) , 2671-2682
Frequency Adaptive CDSC-PLL Using Axis Drift Control Under Adverse Grid Condition
This paper presents a new technique to adapt the cascaded delayed signal cancellation phase-locked loop (CDSC-PLL) using a proposed axis drift control (ADC). When grid frequency changes, the estimated grid angle by PLL drifts with a residual error proportional to the frequency change value thus, the accuracy and performance of the conventional CDSC-PLL is deteriorated which can lead to malfunction of the connected applications. Accordingly, CDSC-PLL type has to be adaptable to frequency changes with high immunity to grid disturbances. Designing frequency adapted CDSC-PLL is complex and needs a dedicated design due to the high nonlinearity introduced by adaptive loops. The ADC is proposed as an online adaptive technique that contains a self-tuned DSC operator to mitigate the grid disturbances and a PI controller to perform the adaptation task. The proposed technique is mathematically analyzed and systematic tuning methods are presented. A new analysis for CDSC under off-nominal sample parameter is presented and verified. The robustness of proposed adaptive controller is investigated under parameters uncertainty and various grid disturbances. The proposed technique is numerically and experimentally verified.
- 1 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 64 (4) , 2671-2682
Frequency Adaptive CDSC-PLL Using Axis Drift Control Under Adverse Grid Condition
This paper presents a new technique to adapt the cascaded delayed signal cancellation phase-locked loop (CDSC-PLL) using a proposed axis drift control (ADC). When grid frequency changes, the estimated grid angle by PLL drifts with a residual error proportional to the frequency change value thus, the accuracy and performance of the conventional CDSC-PLL is deteriorated which can lead to malfunction of the connected applications. Accordingly, CDSC-PLL type has to be adaptable to frequency changes with high immunity to grid disturbances. Designing frequency adapted CDSC-PLL is complex and needs a dedicated design due to the high nonlinearity introduced by adaptive loops. The ADC is proposed as an online adaptive technique that contains a self-tuned DSC operator to mitigate the grid disturbances and a PI controller to perform the adaptation task. The proposed technique is mathematically analyzed and systematic tuning methods are presented. A new analysis for CDSC under off-nominal sample parameter is presented and verified. The robustness of proposed adaptive controller is investigated under parameters uncertainty and various grid disturbances. The proposed technique is numerically and experimentally verified.
- 19 December 2012
- Published by Taylor & Francis in International Journal of Sustainable Energy
- Vol. 33 (3) , 606-618
Effect of intermittent voltage source converter faults on the overall performance of wind energy conversion system
The doubly fed induction generator (DFIG) is interfaced to the AC network through voltage source converters (VSCs) which are considered to be the core of the DFIG system. This paper investigates the impact of different intermittent VSC faults on the overall performance of a DFIG-based wind energy conversion system (WECS). The fault ride through capability of the DFIG under various VSC faults is also investigated. Faults such as open circuit and short circuit across the switches, when they occur within the grid side converter (GSC) and rotor side converter (RSC), are considered and compared in this paper. Short circuit and open circuit across the DC-link capacitor are also considered in this study as common VSC problems. Simulation results indicate that the short circuit faults have a severe impact on the overall performance of the DFIG, especially when they occur within the GSC. This is attributed to the fact that the GSC directly regulates the point of common coupling voltage. The open circuit faults have less impact on the performance of the DFIG-based WECS. A proper controller along with flexible AC transmission device should be available to compensate the required active and reactive power during these faults. A protection technique is necessary to detect these faults in advance to protect the VSC switches and the machine winding from any catastrophic failure.
- 19 December 2012
- Published by Taylor & Francis in International Journal of Sustainable Energy
- Vol. 33 (3) , 606-618
Effect of intermittent voltage source converter faults on the overall performance of wind energy conversion system
The doubly fed induction generator (DFIG) is interfaced to the AC network through voltage source converters (VSCs) which are considered to be the core of the DFIG system. This paper investigates the impact of different intermittent VSC faults on the overall performance of a DFIG-based wind energy conversion system (WECS). The fault ride through capability of the DFIG under various VSC faults is also investigated. Faults such as open circuit and short circuit across the switches, when they occur within the grid side converter (GSC) and rotor side converter (RSC), are considered and compared in this paper. Short circuit and open circuit across the DC-link capacitor are also considered in this study as common VSC problems. Simulation results indicate that the short circuit faults have a severe impact on the overall performance of the DFIG, especially when they occur within the GSC. This is attributed to the fact that the GSC directly regulates the point of common coupling voltage. The open circuit faults have less impact on the performance of the DFIG-based WECS. A proper controller along with flexible AC transmission device should be available to compensate the required active and reactive power during these faults. A protection technique is necessary to detect these faults in advance to protect the VSC switches and the machine winding from any catastrophic failure.