Latest Publications

  • Open Access

    Optic disc drusen: Recent developments on a slow-moving condition

    by Chuen Yen Hong, Jesse Gale

    Optic disc drusen (ODD) are benign acellular calcified deposits that typically form early in life. They do not normally cause symptoms, so ODD are often detected incidentally as an abnormal or potentially swollen optic disc appearance. Distinguishing ODD from true optic disc edema is essential, and now, multimodal imaging, particularly enhanced-depth imaging optical coherence tomography, can detect ODD accurately and reduce the need for further investigations. The origins of ODD are unknown, although the potentially unique finding of heavily calcified extracellular mitochondria in the optic disc raises hypotheses about local astrocyte clearance of dysfunctional mitochondria. Strong familial clustering suggests dominant or polygenic inheritance, and yet the most interesting candidate gene association is the recessive ABCC6 . These emerging genetic associations both illuminate the pathogenesis and raise potential therapeutic targets for ODD. This narrative review synthesizes current knowledge on diagnosis, epidemiology, pathogenesis, genetic associations, and emerging therapeutic approaches, aiming to support clinicians in the diagnosis and management of ODD, and also highlights directions for future research.


  • The optical performance of a 3D printed, titanium dioxide painted, Ganzfeld bowl

    by Jesse Gale, Samuel Sartie, Patrick Dougherty, Callum Allen, Mark Bagley, Mirjam Münch, Simon Fraser

    The emergence of three dimensional (3D) printing has inspired creative ways to enable clinicians to make their own medical devices at low cost, a process called distributed manufacture. Devices for light stimulation, such as for visual electrophysiology or pupillometry, require both physical and optical properties. Here we tested whether a 3D printed (fused deposition modelling, FDM) poly-lactic acid (PLA) surface can exhibit Lambertian reflectance, and tested the behaviour of a 3D printed Ganzfeld bowl as an integrating sphere. White PLA transmits light, so a painted inside surface was necessary. We tested whether the spectral and Lambertian reflecting properties of low cost titanium dioxide (TiO2) based paint was equivalent to specialist barium sulphate (BaSO4) coating. Our measurements indicated that our prototype Ganzfeld with TiO2 coating reflected all wavelengths equally and had radiance uniformity of 90 % which compared well to other published designs. In many jurisdictions regulation prevents a do-it-yourself approach to medical devices, but these approaches might facilitate interested clinicians to create devices for ethically approved research and assist those with severe resource limitations.


  • Angioid streaks and optic disc drusen in a patient with congenital dyserythropoietic anaemia

    by Yuanzhang Jiao, Huib Buyck, Jesse Gale

    A man in his 60s with dry eye symptoms was noted to have angioid streaks under the peripapillary retina. Congenital dyserythropoietic anaemia was the major health issue throughout his life, requiring venesection for iron overload, but no transfusions for many years. Close inspection of the eyes with optical coherence tomography also detected small subclinical optic disc drusen, which have not been reported in association with congenital dyserythropoietic anaemia. Together, optic disc drusen and angioid streaks represent an ectopic calcification phenotype in the eye and can be seen in the more common inherited condition of pseudoxanthoma elasticum or other inherited haemolytic anaemias such as sickle cell or thalassaemia. These associations highlight the role of pyrophosphate as a physiological inhibitor of calcification, and deficiencies of serum pyrophosphate lead to excessive and ectopic calcification. This raises intriguing hypotheses for the treatment of optic disc drusen, angioid streaks and other conditions of ectopic calcification.


  • Open Access

    Alcohol wipes are the most justifiably sustainable disinfection method for Goldmann tonometry

    by James W. Corbett, Sukhpal S. Sandhu, Jesse Gale

    The essential technique of Goldmann tonometry is thought to have a risk of nosocomial infection, and thus there has been pressure to use single-use tonometer tips or slower and more-costly methods of disinfection for reusable tips. Here we review the evidence of infection from tonometry and the evidence behind different disinfection methods. The only infection reported to be transmitted by tonometry is adenoviral epidemic keratoconjunctivitis, which is also transmitted without tonometry and is a relatively low-morbidity infection. More serious eye infections or systemic infections have never been reported to be attributed to tonometry or eye examination. The most popular, affordable, quick and sustainable method of disinfection, using alcohol swabs to wipe the tip, is the only economically justifiable method.


  • Open Access

    The relationship between colour vision defects and visual field tests in glaucoma

    by Jesse Gale, Zung Mai, Anthony Wells, Robin Willink

    Purpose The relationship between colour vision defects (CVD) and visual field test results in glaucoma can be counterintuitive. We sought to examine the relationship between three tests of colour vision and three types of perimetry in glaucoma.Materials and methods In this cross-sectional study, we included both eyes of 53 patients with glaucoma. We conducted white-on-white Standard Automated Perimetry (SAP), blue-on-yellow Short Wave Automatic Perimetry (SWAP) and sine-grating Frequency Doubling Technology (FDT) perimetry, as well as Ishihara, Hardy-Rand-Rittler (HRR) and desaturated Lanthony D-15 tests of central colour vision. Our primary analysis used Kendall’s tau to measure the probability that an increase in one variable, the average of SAP or SWAP of FDT central point sensitivities, is accompanied by concordant increase in colour vision.Results There are weak concordances between D15 and SAP (-0.01 ≤ τ ≤ 0.21), D15 and SWAP (-0.03 ≤ τ ≤ 0.22), and D15 and FPT (0.03 ≤ τ ≤ 0.30). There was insufficient evidence in the sample to conclude that these concordances differ (p = 0.08). There appear to be stronger concordances between HRR and the results of visual field tests (0.09 ≤ τ), the strongest being with FDT (0.13 ≤ τ).Conclusions The effect of glaucoma on colour vision appears to be diffuse, not closely concordant with overall or central visual field function.

  • Arcuate pattern of retinal ganglion cell axons in oculocutaneous albinism has implications for axon pathfinding

    by Jesse Gale, James Corbett, Su-Young Seo, Anne-Marie Yardley

    Humans have a characteristic arcuate pattern of retinal ganglion cell (RGC) axons on the retina, indicating an unknown axon-repellent factor in the macula during development. This arcuate pattern has implications for diseases such as glaucoma. Albinism is an interesting group of conditions with loss of the radial foveal architecture (foveal hypoplasia) and abnormal RGC axon pathfinding at the optic chiasm. Here, we achieved optical coherence tomography imaging in a patient with oculocutaneous albinism type 1 (OCA1), which is challenging due to nystagmus. These scans showed a normal pattern of arcuate ganglion cells despite a severely hypoplastic fovea. This implies that there are multiple factors contributing to the radial pattern of the fovea and arcuate pattern of RGC axons, but OCA1 does not affect the latter.


  • Sarcoidosis presenting as a suspected metastasis around the optic disc

    by James Corbett, Michelle Woolley, Kenneth Chan, Jesse Gale

    We present a case of systemic sarcoidosis presenting with mild blurred vision, limitation of left eye movements and choroidal infiltration around the left optic disc. Symptoms and signs of inflammation were absent, and secondary malignancy was suspected. After a prolonged series of investigations revealed multiple asymptomatic inflammatory lesions, subsequent lymph node biopsy revealed non-caseating granulomas. This case highlights the protean manifestations of sarcoidosis and the sophisticated investigations that may be required to diagnose it.

  • The Carbon Footprint of Glaucoma Care With Drops or Laser First

    by Kyle Foo, Francesc March, Sjoerd Elferink, Jesse Gale