Afiq Mohd Laziz
Afiq Mohd Laziz has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Ku Zilati Ku Shaari
Department of Chemical Engineering, Universiti Teknologi PETRONAS, Seri Iskandar 32610, Perak Darul Ridzuan, Malaysia
3 shared publications - Muhammad Roil Bilad
Faculty of Integrated Technologies, Universiti Brunei Darussalam, Jalan Tungku Link, Gadong BE1410, Brunei
3 shared publications - Chong Yang Chuah
Universiti Malaya
2 shared publications Jens Denecke
Institute for Thermo-Fluid-Dynamics, Karlsruhe University of Applied Sciences, Karlsruhe 76133, Germany
2 shared publications- Jens Denecke
CSE Center of Safety Excellence (CSE-Institut), Joseph-von-Fraunhofer-Str. 9, 76327 Pfinztal, Germany
2 shared publications - Ku Zilati Ku Shaari
Chemical Engineering Department, Prince Mohammad Bin Fahd University, Al Khobar 34754, Saudi Arabia
2 shared publications
Latest Publications
- Open Access
- 10 October 2026
- Published by Elsevier in SSRN Electronic Journal
Non-Isothermal CFD Analysis of Joule-Thomson Effects in Spiral Wound Membranes for CO2 Removal from Natural Gas
Joule-Thomson (JT) cooling can significantly affect high pressure membrane gas separation. However, its influence on local membrane transport and separation performance in spiral-wound membrane (SWM) modules remains poorly understood. This study develops a non-isothermal computational fluid dynamics (CFD) framework coupling JT cooling, real-gas thermodynamics, and temperature-dependent multicomponent membrane transport for CO2 removal from natural gas. The thermal model was validated using experimental temperature data obtained from an in-house flat-sheet PSf membrane system, while the membrane mass-transfer formulation was validated using published separation data. Simulations were performed with and without the JT effect to isolate its influence on membrane separation performance. Incorporating the JT effect produced temperature variations that altered CO2 and CH4 permeance, CO2/CH4 selectivity, and retentate composition. Increasing the feed temperature from 15 to 40 °C increased CO2 permeance from 29 to 41 GPU and stage cut from 22 to 29%. In contrast, increasing the feed CO2 concentration from 10 to 70 mol% intensified JT cooling, reducing the minimum temperature from 293.92 to 261.33 K and increasing the stage cut from 9 to 35%. These findings demonstrate that JT cooling is strongly coupled with membrane transport and should be considered in high-pressure SWM simulations. The developed framework provides a spatially resolved approach for assessing coupled thermal-transport behavior in natural-gas membrane separation.
- 10 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNon-Isothermal CFD Analysis of Joule-Thomson Effects in Spiral Wound Membranes for CO2 Removal from Natural Gas
Joule-Thomson (JT) cooling can significantly affect high pressure membrane gas separation. However, its influence on local membrane transport and separation performance in spiral-wound membrane (SWM) modules remains poorly understood. This study develops a non-isothermal computational fluid dynamics (CFD) framework coupling JT cooling, real-gas thermodynamics, and temperature-dependent multicomponent membrane transport for CO2 removal from natural gas. The thermal model was validated using experimental temperature data obtained from an in-house flat-sheet PSf membrane system, while the membrane mass-transfer formulation was validated using published separation data. Simulations were performed with and without the JT effect to isolate its influence on membrane separation performance. Incorporating the JT effect produced temperature variations that altered CO2 and CH4 permeance, CO2/CH4 selectivity, and retentate composition. Increasing the feed temperature from 15 to 40 °C increased CO2 permeance from 29 to 41 GPU and stage cut from 22 to 29%. In contrast, increasing the feed CO2 concentration from 10 to 70 mol% intensified JT cooling, reducing the minimum temperature from 293.92 to 261.33 K and increasing the stage cut from 9 to 35%. These findings demonstrate that JT cooling is strongly coupled with membrane transport and should be considered in high-pressure SWM simulations. The developed framework provides a spatially resolved approach for assessing coupled thermal-transport behavior in natural-gas membrane separation.
- Open Access
- 30 September 2026
- Published by LEMIGAS RD Center for Oil and Gas Technology in Scientific Contributions Oil and Gas
- Vol. 49 (3) , 705-722
Effect of KOH Concentration on Biodiesel Production from Waste Cooking Oil: Comparison of Batch and Microchannel Reactor
The quality of biodiesel produced from waste cooking oil (WCO) is confirmed by compliance with the ASTM D6751 standard specification to ensure the products meet commercial fuel standards. Compared with batch reactors, microreactors offer several benefits, including reduced residence time, lower specific energy consumption (SEC), and improved processing of low-quality WCO feedstock with high viscosity and free fatty acid (FFA) content. However, a knowledge gap remains regarding the capacity of reactor systems to handle highly degraded WCO feedstock while complying with ASTM D6751, especially total glycerin limits (≤ 0.240 wt%) and minimum ester content. In addition, comparative data between batch reactors and microchannel reactors for low-quality oil processing remain limited. This research aims to establish an evaluation framework for assessing reactor tolerance to highly degraded WCO feedstock by comparing the performance of batch reactors and microchannel reactors under slug flow conditions. Results indicate that the microchannel reactor, with an 80-second residence time, achieved a peak FAME conversion of 98.2% under optimal conditions (1.0 wt% KOH, HH oil) and consistently maintained high conversion (91.1%-98.2%) across all tested feedstocks. Conversely, the batch reactor, with a one-hour reaction time, achieved a conversion of only 68.2%- 88.4% and could not reach the high FAME content required to exceed the total glycerin limit based on ASTM D6751 (> 1.0% berat). The SEC of the microchannel reactor was also 98.96% lower than that of the batch reactor. Consequently, the microchannel reactor demonstrated superior efficiency compared to the batch reactor in transforming lower-quality WCO into biodiesel that meets the ASTM D6751 standard in terms of FAME conversion, energy efficiency, and processing time. Future research may explore the design and optimisation of microchannel reactors for industrial-scale applications, as well as test a wider range of WCO quality variations to establish a more stable and sustainable biodiesel production system.
- 30 September 2026
- Published by LEMIGAS RD Center for Oil and Gas Technology in Scientific Contributions Oil and Gas
- Vol. 49 (3) , 705-722
Open AccessEffect of KOH Concentration on Biodiesel Production from Waste Cooking Oil: Comparison of Batch and Microchannel Reactor
The quality of biodiesel produced from waste cooking oil (WCO) is confirmed by compliance with the ASTM D6751 standard specification to ensure the products meet commercial fuel standards. Compared with batch reactors, microreactors offer several benefits, including reduced residence time, lower specific energy consumption (SEC), and improved processing of low-quality WCO feedstock with high viscosity and free fatty acid (FFA) content. However, a knowledge gap remains regarding the capacity of reactor systems to handle highly degraded WCO feedstock while complying with ASTM D6751, especially total glycerin limits (≤ 0.240 wt%) and minimum ester content. In addition, comparative data between batch reactors and microchannel reactors for low-quality oil processing remain limited. This research aims to establish an evaluation framework for assessing reactor tolerance to highly degraded WCO feedstock by comparing the performance of batch reactors and microchannel reactors under slug flow conditions. Results indicate that the microchannel reactor, with an 80-second residence time, achieved a peak FAME conversion of 98.2% under optimal conditions (1.0 wt% KOH, HH oil) and consistently maintained high conversion (91.1%-98.2%) across all tested feedstocks. Conversely, the batch reactor, with a one-hour reaction time, achieved a conversion of only 68.2%- 88.4% and could not reach the high FAME content required to exceed the total glycerin limit based on ASTM D6751 (> 1.0% berat). The SEC of the microchannel reactor was also 98.96% lower than that of the batch reactor. Consequently, the microchannel reactor demonstrated superior efficiency compared to the batch reactor in transforming lower-quality WCO into biodiesel that meets the ASTM D6751 standard in terms of FAME conversion, energy efficiency, and processing time. Future research may explore the design and optimisation of microchannel reactors for industrial-scale applications, as well as test a wider range of WCO quality variations to establish a more stable and sustainable biodiesel production system.
- 25 June 2026
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 163, 233-262
New opportunities in MOF-based catalysts for conversion of CO2-to-dimethyl ether
- 25 June 2026
- Published by Elsevier in Journal of Industrial and Engineering Chemistry
- Vol. 163, 233-262
New opportunities in MOF-based catalysts for conversion of CO2-to-dimethyl ether
- Open Access
- 15 September 2025
- Published by Multimedia University in Journal of Engineering Technology and Applied Physics
- Vol. 7 (2) , 65-74
Multiphase Flow Pattern Hydrodynamics of Carbon Dioxide and Water in Microchannel Reactor
The utilization of CO2 is crucial to convert waste into valuable products, such as fuels. Microchannel reactor technology has gained attention for CO2 utilization due to their higher interfacial area compared to traditional reactors. Understanding flow regimes is critical for optimizing mass transfer efficiency. Hence, this project aims to create a new flow pattern map for CO2 and water and investigate how gas bubble and liquid slug properties are affected by the change in superficial velocity. Thus, the interfacial area for each flow pattern can be observed which affects the mass transfer performance. The dimensions of flow pattern were measured, so the interfacial area could be calculated accordingly. The amount of CO2 absorbed into water was determined using the titration method. Then the liquid side mass transfer coefficient for slug flow was determined from the models proposed by van Baten and Krishna (2004). In the end, the rate of mass transfer was determined for slug flow. The results show that slug flow is formed at high gas-to-liquid ratio. Longer slug flow has higher interfacial area and more CO2 is absorbed through diffusion. A larger interfacial area contributes to higher mass transfer rate, so this proves that the microchannel is good for CO2 utilization process.
- 15 September 2025
- Published by Multimedia University in Journal of Engineering Technology and Applied Physics
- Vol. 7 (2) , 65-74
Open AccessMultiphase Flow Pattern Hydrodynamics of Carbon Dioxide and Water in Microchannel Reactor
The utilization of CO2 is crucial to convert waste into valuable products, such as fuels. Microchannel reactor technology has gained attention for CO2 utilization due to their higher interfacial area compared to traditional reactors. Understanding flow regimes is critical for optimizing mass transfer efficiency. Hence, this project aims to create a new flow pattern map for CO2 and water and investigate how gas bubble and liquid slug properties are affected by the change in superficial velocity. Thus, the interfacial area for each flow pattern can be observed which affects the mass transfer performance. The dimensions of flow pattern were measured, so the interfacial area could be calculated accordingly. The amount of CO2 absorbed into water was determined using the titration method. Then the liquid side mass transfer coefficient for slug flow was determined from the models proposed by van Baten and Krishna (2004). In the end, the rate of mass transfer was determined for slug flow. The results show that slug flow is formed at high gas-to-liquid ratio. Longer slug flow has higher interfacial area and more CO2 is absorbed through diffusion. A larger interfacial area contributes to higher mass transfer rate, so this proves that the microchannel is good for CO2 utilization process.
- Open Access
- 3 April 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (7) , 6148
Investigation of Mass-Transfer Performance for Biodiesel Reaction in Microchannel Reactor using Volume-of-Fluid with Species-Transport Model
A microchannel reactor improves the overall mass and heat transfer as compared with a conventional reactor. This is attributed to the creation of a high area-to-volume ratio and enhanced mixing due to the presence of the vortices inside the slug. In this paper, the mass-transfer performance was studied using a cross-junction microchannel. Subsequently, the computational fluid dynamic (CFD) method was used to observe the oil concentration contour inside a slug using volume-of-fluid (VOF) with the species-transport model. Based on the simulation results, the oil concentration was accumulated in both the slug’s rear and front regions. Hence, the creation of four vortices resulted in the creation of dead zones at the low-oil-concentration region. Furthermore, it has been observed that an optimum flow rate in a microchannel reactor is required to achieve a high mass transfer. A higher oil concentration was measured during the slug formation at a low flow regime due to the long residence time. In contrast, a high mass transfer has been reported during the slug-moving stage due to the higher vortices velocity, resulting in enhanced mixing and mass transfer. Hence, slug forming and the moving stage substantially influenced mass transfer at low and high flow rates, respectively.
- 3 April 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (7) , 6148
Open AccessInvestigation of Mass-Transfer Performance for Biodiesel Reaction in Microchannel Reactor using Volume-of-Fluid with Species-Transport Model
A microchannel reactor improves the overall mass and heat transfer as compared with a conventional reactor. This is attributed to the creation of a high area-to-volume ratio and enhanced mixing due to the presence of the vortices inside the slug. In this paper, the mass-transfer performance was studied using a cross-junction microchannel. Subsequently, the computational fluid dynamic (CFD) method was used to observe the oil concentration contour inside a slug using volume-of-fluid (VOF) with the species-transport model. Based on the simulation results, the oil concentration was accumulated in both the slug’s rear and front regions. Hence, the creation of four vortices resulted in the creation of dead zones at the low-oil-concentration region. Furthermore, it has been observed that an optimum flow rate in a microchannel reactor is required to achieve a high mass transfer. A higher oil concentration was measured during the slug formation at a low flow regime due to the long residence time. In contrast, a high mass transfer has been reported during the slug-moving stage due to the higher vortices velocity, resulting in enhanced mixing and mass transfer. Hence, slug forming and the moving stage substantially influenced mass transfer at low and high flow rates, respectively.
- Open Access
A Rotary Spacer System for Energy-Efficient Membrane Fouling Control in Oil/Water Emulsion Filtration
Membrane fouling deteriorates membrane filtration performances. Hence, mitigating membrane fouling is the key factor in sustaining the membrane process, particularly when treating fouling-prone feed, such as oil/water emulsions. The use of spacers has been expanded in the membrane module system, including for membrane fouling control. This study proposed a rotating spacer system to ameliorate membrane fouling issues when treating an oil/water emulsion. The system’s effectiveness was assessed by investigating the effect of rotating speed and membrane-to-disk gap on the hydraulic performance and the energy input and through computational fluid dynamics (CFD) simulation. The results showed that the newly developed rotary spacer system was effective and energy-efficient for fouling control. The CFD simulation results proved that the spacer rotations induced secondary flow near the membrane surface and imposed shear rate and lift force to exert fouling control. Increasing the rotation speed to an average linear velocity of 0.44 m/s increased the permeability from 126.8 ± 2.1 to 175.5 ± 2.7 Lm−2h−1bar−1. The system showed better performance at a lower spacer-to-membrane gap, in which increasing the gap from 0.5 to 2.0 cm lowered the permeability from 175.5 ± 2.7 to 126.7 ± 2.0 Lm−2h−1bar−1. Interestingly, the rotary system showed a low energy input of 1.08 to 4.08 × 10−3 kWhm−3 permeate when run at linear velocities of 0.27 to 0.44 ms−1. Overall, the findings suggest the competitiveness of the rotary spacer system as a method for membrane fouling control.
Open AccessA Rotary Spacer System for Energy-Efficient Membrane Fouling Control in Oil/Water Emulsion Filtration
Membrane fouling deteriorates membrane filtration performances. Hence, mitigating membrane fouling is the key factor in sustaining the membrane process, particularly when treating fouling-prone feed, such as oil/water emulsions. The use of spacers has been expanded in the membrane module system, including for membrane fouling control. This study proposed a rotating spacer system to ameliorate membrane fouling issues when treating an oil/water emulsion. The system’s effectiveness was assessed by investigating the effect of rotating speed and membrane-to-disk gap on the hydraulic performance and the energy input and through computational fluid dynamics (CFD) simulation. The results showed that the newly developed rotary spacer system was effective and energy-efficient for fouling control. The CFD simulation results proved that the spacer rotations induced secondary flow near the membrane surface and imposed shear rate and lift force to exert fouling control. Increasing the rotation speed to an average linear velocity of 0.44 m/s increased the permeability from 126.8 ± 2.1 to 175.5 ± 2.7 Lm−2h−1bar−1. The system showed better performance at a lower spacer-to-membrane gap, in which increasing the gap from 0.5 to 2.0 cm lowered the permeability from 175.5 ± 2.7 to 126.7 ± 2.0 Lm−2h−1bar−1. Interestingly, the rotary system showed a low energy input of 1.08 to 4.08 × 10−3 kWhm−3 permeate when run at linear velocities of 0.27 to 0.44 ms−1. Overall, the findings suggest the competitiveness of the rotary spacer system as a method for membrane fouling control.
- Open Access
Recent Progress in Synthesis and Application of Activated Carbon for CO2 Capture
Greenhouse gas emissions to the atmosphere have been a long-standing issue that has existed since the Industrial Revolution. To date, carbon dioxide capture through the carbon capture, utilization, and storage approach has been one of the feasible options to combat the strong release of carbon dioxide into the atmosphere. This review focuses in general on the utilization of activated carbon as a tool when performing the carbon-capture process. Activated carbon possesses a lower isosteric heat of adsorption and a stronger tolerance to humidity as compared to zeolites and metal–organic frameworks, despite the overall gas-separation performance of activated carbon being comparatively lower. In addition, investigations of the activation methods of activated carbon are summarized in this review, together with an illustration of CO2 adsorption performance, in the context of process simulations and pilot-plant studies. This is followed by providing future research directions in terms of the applicability of activated carbon in real CO2 adsorption processes.
Open AccessRecent Progress in Synthesis and Application of Activated Carbon for CO2 Capture
Greenhouse gas emissions to the atmosphere have been a long-standing issue that has existed since the Industrial Revolution. To date, carbon dioxide capture through the carbon capture, utilization, and storage approach has been one of the feasible options to combat the strong release of carbon dioxide into the atmosphere. This review focuses in general on the utilization of activated carbon as a tool when performing the carbon-capture process. Activated carbon possesses a lower isosteric heat of adsorption and a stronger tolerance to humidity as compared to zeolites and metal–organic frameworks, despite the overall gas-separation performance of activated carbon being comparatively lower. In addition, investigations of the activation methods of activated carbon are summarized in this review, together with an illustration of CO2 adsorption performance, in the context of process simulations and pilot-plant studies. This is followed by providing future research directions in terms of the applicability of activated carbon in real CO2 adsorption processes.
- Open Access
- 23 January 2021
- Published by Viet Nam National University Ho Chi Minh City in Science & Technology Development Journal - Engineering and Technology
- Vol. 4 (2) , 920-931
Hydrodynamic studies on liquid-liquid two phase flow separation in microchannel by computational fluid dynamic modelling
Microfluidic systems undergo rapid expansion of its application in different industries over the few decades as its surface tension-dominated property provides better mixing and improves mass transfer between two immiscible liquids. Synthesis of biodiesel via transesterification of vegetable oil and methanol in microfluidic systems by droplet flow requires separation of the products after the reaction occurred. The separation technique for multiphase fluid flow in the microfluidic system is different from the macro-system, as the gravitational force is overtaken by surface force. To understand these phenomena completely, a study on the hydrodynamic characteristics of two-phase oil-methanol system in microchannel was carried out. A multiphase Volume of Fluid model was developed to predict the fluid flow in the microchannel. An inline separator design was proposed along with its variable to obtain effective separation for the oil-methanol system. The separation performance was evaluated based on the amount of oil recovered and its purity. The capability of the developed model has been validated through a comparison of simulation results with published experiment. It was predicted that the purity of recovered oil was increased by more than 46% when the design with side openings arranged at both sides of the microchannel. The highest percentage recovery of oil from the mixture was simulated at 91.3% by adding the number of side openings to ensure the maximum recovery. The oil that was separated by the inline separator was predicted to be at 100% purity, which indicates that no methanol contamination throughout the separation process. The purity of the separated product can be increased by manipulating the pressure drop across the side openings. Hence, it can be concluded that the separation in a large diameter microchannel system is possible and methodology can be tuned to achieve the separation goal. Finally, the simulation results showed that the present volume of fluid model had a good agreement with the published experiment.
- 23 January 2021
- Published by Viet Nam National University Ho Chi Minh City in Science & Technology Development Journal - Engineering and Technology
- Vol. 4 (2) , 920-931
Open AccessHydrodynamic studies on liquid-liquid two phase flow separation in microchannel by computational fluid dynamic modelling
Microfluidic systems undergo rapid expansion of its application in different industries over the few decades as its surface tension-dominated property provides better mixing and improves mass transfer between two immiscible liquids. Synthesis of biodiesel via transesterification of vegetable oil and methanol in microfluidic systems by droplet flow requires separation of the products after the reaction occurred. The separation technique for multiphase fluid flow in the microfluidic system is different from the macro-system, as the gravitational force is overtaken by surface force. To understand these phenomena completely, a study on the hydrodynamic characteristics of two-phase oil-methanol system in microchannel was carried out. A multiphase Volume of Fluid model was developed to predict the fluid flow in the microchannel. An inline separator design was proposed along with its variable to obtain effective separation for the oil-methanol system. The separation performance was evaluated based on the amount of oil recovered and its purity. The capability of the developed model has been validated through a comparison of simulation results with published experiment. It was predicted that the purity of recovered oil was increased by more than 46% when the design with side openings arranged at both sides of the microchannel. The highest percentage recovery of oil from the mixture was simulated at 91.3% by adding the number of side openings to ensure the maximum recovery. The oil that was separated by the inline separator was predicted to be at 100% purity, which indicates that no methanol contamination throughout the separation process. The purity of the separated product can be increased by manipulating the pressure drop across the side openings. Hence, it can be concluded that the separation in a large diameter microchannel system is possible and methodology can be tuned to achieve the separation goal. Finally, the simulation results showed that the present volume of fluid model had a good agreement with the published experiment.
- 1 January 2020
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 27 (5) , 439-461
THERMAL PERFORMANCE OF GRAPHENE OXIDE NANOFLUID IN MICROCHANNEL HEAT EXCHANGER
Device miniaturization and complex work load due to rapid growth in technologies have imposed great challenge in thermal management aspect to prevent overheating. Nanofluids are emerging thermal solutions due to their enhanced thermal properties. Recently, graphene oxide (GO) has been proposed due to its high thermal conductivity. This study investigates the thermal performance of graphene oxide nanofluids (GO-NFs) in microchannel heat exchanger (MCHE). GO nanoparticles were synthesized and confirmed using XRD, whereas GO-NFs (0.02-1.0 wt.%) were prepared and analyzed in terms of viscosity and thermal conductivity. Results showed that minor addition of GO nanoparticles did not significantly affect the viscosity of GO-NFs whereas the thermal conductivity was remarkably enhanced. The thermal performance of GO-NFs in MCHE was investigated at different inlet flow rate (1 – 6 mL/min) and set temperature (50 – 90 oC). At a given set temperature, GO-NFs showed excellent thermal performance than water due to higher thermal conductivity. Furthermore, GO-NFs showed better thermal performance at higher set temperature due to higher thermal conductivity at higher temperature. These indicate that GO-NF is very effective in heat transfer applications compared to water. This is because in a heat removal process using fluid, it tends to heat up as it passes through the system. This will reduce the effectiveness of the fluid to remove heat due to the drop in the temperature gradient. However, this is not the case for GO-NFs as they have higher thermal conductivity at higher temperature which enables them to further absorb heat at a higher rate.
- 1 January 2020
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 27 (5) , 439-461
THERMAL PERFORMANCE OF GRAPHENE OXIDE NANOFLUID IN MICROCHANNEL HEAT EXCHANGER
Device miniaturization and complex work load due to rapid growth in technologies have imposed great challenge in thermal management aspect to prevent overheating. Nanofluids are emerging thermal solutions due to their enhanced thermal properties. Recently, graphene oxide (GO) has been proposed due to its high thermal conductivity. This study investigates the thermal performance of graphene oxide nanofluids (GO-NFs) in microchannel heat exchanger (MCHE). GO nanoparticles were synthesized and confirmed using XRD, whereas GO-NFs (0.02-1.0 wt.%) were prepared and analyzed in terms of viscosity and thermal conductivity. Results showed that minor addition of GO nanoparticles did not significantly affect the viscosity of GO-NFs whereas the thermal conductivity was remarkably enhanced. The thermal performance of GO-NFs in MCHE was investigated at different inlet flow rate (1 – 6 mL/min) and set temperature (50 – 90 oC). At a given set temperature, GO-NFs showed excellent thermal performance than water due to higher thermal conductivity. Furthermore, GO-NFs showed better thermal performance at higher set temperature due to higher thermal conductivity at higher temperature. These indicate that GO-NF is very effective in heat transfer applications compared to water. This is because in a heat removal process using fluid, it tends to heat up as it passes through the system. This will reduce the effectiveness of the fluid to remove heat due to the drop in the temperature gradient. However, this is not the case for GO-NFs as they have higher thermal conductivity at higher temperature which enables them to further absorb heat at a higher rate.