SLSophie Lindgren

Sophie Lindgren

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sophie Lindgren has a total of 50 co-authors. Here are the top co-authors by number of shared publications:

  • Katarina Hallén

    Department of Anaesthesiology and Intensive Care Medicine, Institute of Clinical Sciences, The Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden

    3 shared publications
  • O. Stenqvist

    Department of Anaesthesiology and Intensive Care Medicine, Institute of Clinical Sciences, The Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden

    3 shared publications
  • Ola Stenqvist

    Department of Anaesthesiology and Intensive Care Medicine, Institute of Clinical Sciences, The Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden

    3 shared publications
  • Pether Jildenstål

    Institute of Health and Care Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden

    3 shared publications
  • Sven‐Erik Ricksten

    Department of Anesthesiology and Intensive Care Medicine, Institute of Clinical Sciences, Sahlgrenska Academy University of Gothenburg Gothenburg Sweden

    3 shared publications
  • Carina Sjöberg

    Department of Health Sciences, Faculty of Medicine, Lund University, Sweden

    2 shared publications

Latest Publications

  • Open Access

    Inter‐Individual Variation in LUNG Mechanics Assessed by the Non‐Invasive PEEP ‐Step Method During Laparoscopic and Robotic Surgery Indicates Need for Individualized Ventilatory Settings

    by Ali Abdulhussein, Sara Hammarskjöld, Ola Stenqvist, Per Persson, Katarina Hallén, Pether Jildenstål, Sophie Lindgren

    Background: During laparoscopic surgery, abdominal carbon dioxide (CO 2 ) insufflation in the supine position and with head‐down tilt for robotic surgery increases abdominal pressure and pushes the diaphragm cranially. This causes a decrease in end‐expiratory lung volume and in lung and chest wall compliance. These effects can be counteracted by the application of PEEP. Our study aimed to measure lung and chest wall mechanics during laparoscopic surgery using a non‐invasive method (PEEP‐step method) and to determine the optimal PEEP level for each patient. Methods: Thirty‐two patients scheduled for abdominal surgery participated in this observational study with pneumoperitoneum. Fourteen patients underwent surgery for pelvic conditions in head‐down position and 18 in supine position. Data from the ventilator was collected and analysed with a dedicated software, which calculated lung compliance and transpulmonary pressure from a two‐step PEEP increase. Measurements were performed after induction, after pneumoperitoneum in supine/tilt head‐down and before emergence. Results: Lung and chest wall compliance decreased during CO 2 insufflation with high individual variation, and we observed a≈90% increase in transpulmonary driving pressure. After CO 2 ‐desufflation, lung and chest wall compliance returned to near baseline levels on a group level. However, 19 patients had a remaining reduction in lung compliance, six with 20%–50%. Optimal PEEP level calculated by the software was twice the clinical routine level. Conclusions: The study found substantial individual variation in lung compliance during laparoscopic surgery in patients without evident lung disease. This variability does not align well with respiratory system compliance. The findings highlight the need for individualized ventilator settings based on lung‐ rather than respiratory system mechanics. The PEEP‐step method may be a non‐invasive, real‐time bedside tool to identify patients who would benefit from higher PEEP to preserve lung volume and possibly prevent postoperative complications. Editorial Comment: Laparascopic surgical conditions can affect lung mechanics, though not always predictably. This study examined how a test of higher or lower PEEP directly after anaesthesia induction might inform PEEP optimization in the same cases undergoing laparoscopic surgery. Trial Registration: ClinicalTrials.gov (NCT04484727, 2022‐05‐01)

  • Open Access

    Esophageal pressures in supine and prone position: evaluation using high-resolution manometry

    by Viktor Erbring, Magni Gudmundsson, Hannes Widing, Sophie Lindgren, Christian Rylander, Per Persson

    Esophageal pressure (PES), used as a substitute for pleural pressure in calculations of respiratory mechanics, are complex and influenced by several factors. High-resolution manometry (HRM) provides pressure readings over the esophageal length, which makes it possible to identify factors other than respiratory mechanics that influence esophageal pressure. The aim of this study was to describe and explore esophageal pressure in prone and supine position at different ventilatory settings. PES was measured using HRM in 20 mechanically ventilated patients before start of spinal surgery. PEEP of 5 and 12 cmH 2 O were used in supine and prone position while data were recorded continuously. Mean end-expiratory (PES EE ) and tidal variation of esophageal pressures (ΔPES) from sensors in different esophageal regions were compared including a selection of sensors with theoretically optimal pressure readings (PES OPT ). PES EE was significantly lower (MD 3.2–5.7), ΔPES was significantly higher (MD 0.8–1.6 cmH 2 O) and cardiac oscillations were significantly smaller in prone compared to supine position. Differences were dependent on PEEP level and regions of esophagus included. Mean within patient variability of PES EE and ΔPES was 38–540% depending on PEEP level and body position. End-expiratory PES OPT was lower than mean PES EE from larger esophageal regions and less variable. A large variation in PES is seen in both supine and prone position but depends on which sensors are included in calculations of PES. There are significant differences in absolute pressures and in influence from mediastinal organs between supine and prone position.


  • Open Access

    Smart glasses for monitoring vital signs in anaesthesia care settings: a qualitative simulation study

    by Per Enlöf, Carina Sjöberg, Mona Ringdal, Sophie Lindgren, Axel Wolf, Pether Jildenstål

    Background: Monitoring of vital signs is essential in anaesthesia care and plays a key role in preventing adverse events. Technological innovation is recognised as an important factor in enhancing patient safety. Smart glasses represent a novel tool that may support anaesthesia professionals in monitoring vital signs; however, their practical use and user experiences in anaesthesia care remain insufficiently explored. Understanding anaesthesia healthcare professionals’ experiences with this technology is crucial to ensure its safe and effective implementation. In this study, smart glasses from Microsoft HoloLens 2 were used to visualize vital signs in the user’s field of vision. The aim was to explore anaesthesia health care professionals’ experience of using Microsoft HoloLens 2 smart glasses for monitoring vital signs in various simulated anaesthesia care scenarios. Methods: A qualitative study design was used to explore the experiences of nurse anaesthetists and anaesthesiologists. Data were gathered through focus group interviews and subsequently analysed using qualitative content analysis. Results: One overarching theme - a positive yet cautious attitude towards smart glasses - was identified, comprising three categories: Impact on intraoperative monitoring, Usability of the smart glass technology, and Communication challenges. These categories illustrated both advantages and limitations of using smart glasses in simulated anaesthesia care scenarios. Conclusions: The experience of using Microsoft HoloLens 2 for monitoring vital signs in simulated anaesthesia care scenarios revealed a generally positive but careful attitude towards the technology. Participants appreciated its potential to enhance situational awareness through continuous access to vital signs, while also highlighting concerns related to ergonomics, restricted field of view, and possible distraction. The findings offer insights for developers aiming to optimise smart glasses for clinical use. Further refinement and evaluation in clinical settings are needed before broader implementation in anaesthesia practice.

  • Open Access

    Healthcare Professionals’ Perceptions of Pre-, Peri-, and Postoperative Virtual Reality Immersion in Elderly Patients

    by Kristian Hermander, Pether Jildenstål, Sofia Erestam, Peter Dahm, Sophie Lindgren, Joakim Strömberg, Carina Sjöberg

    Background/Objectives: There is a lack of research examining healthcare professionals’ perspectives regarding the potential of non-pharmacological solutions such as immersive virtual reality (VR). The aim of this study was to investigate opportunities and challenges related to the application of immersive virtual reality (VR) technology in patients aged 65 and older undergoing surgery with regional anesthesia and sedation. Method: A qualitative, multicenter study was conducted in the spring of 2024, involving semi-structured interviews with 17 healthcare professionals. Result: A qualitative content analysis of the interviews identified the main theme “Healthcare professionals’ openness to opportunities for this technology for elderly patients”, with the subthemes and themes “elderly patients”, which included the participants’ attitudes towards elderly patients; “virtual reality”, which concerned opportunities, barriers, and risks; and “sustainable healthcare”, which comprised the participants’ thoughts about its impact on sustainable development. Conclusions: The participants suggested potential areas of use for VR during the perioperative period but also identified limitations and risks. They suggested VR was likely to have a positive impact on sustainable healthcare, as well as economic advantages. For its successful implementation, the equipment must be safe. There also needs to be a clear division of responsibilities for it to be functional and suitable for its users. Strategies such as nudging can be used to facilitate its implementation.


  • Open Access

    Assessing neurological prognosis in post-cardiac arrest patients from short vs plain text EEG reports: A survey among intensive care clinicians

    by Linus Lilja, Sara Joelsson, Josefin Nilsson, Meena Thuccani, Peter Lundgren, Sophie Lindgren, Christian Rylander


  • Analysis of central venous access injuries from claims to the Swedish Patient Insurance Company 2009‐2017

    by Sophie Lindgren, Pelle Gustafson, Fredrik Hammarskjöld

    Introduction: Insertion and use of central venous access devices (CVADs) can be associated with serious adverse events. The incidence is generally low but considering the vast use of CVADs the consequences can, from a patient safety and health economics perspective, be severe. No exact knowledge exists of number of catheters or complications in Sweden, as there is currently no comprehensive registry. The aim was to analyse injuries reported to the Swedish National Patient Insurance Company (Löf) within 7 days after insertion or removal of a CVAD.Methods: A retrospective analysis of all injuries filed in the period 2009‐2017 was performed, evaluating patient data, type of catheter, insertion technique and type of injury. If the injury was deemed avoidable by Löf, degree of disability and mortality was registered.Results: A total of 87 claims of injuries were found of which 36 (41%) were assessed as avoidable.The most common injuries were: bleeding (18%), early infection (17%), pneumothorax (17%) and early thrombosis (15%). No patients died of their injuries, but 17 of 36 suffered permanent disability of varying degrees. Ultrasound‐guided insertion was used in 19% of the cases.Conclusion: In Sweden, few injuries related to CVAD use are reported to Löf. About 40% of filed claims were categorized as having an avoidable injury and therefore eligible for compensation. About half of the compensated patients suffered a permanent disability. The results indicate underreporting of CVC‐related injuries in Sweden during the studied time‐period.


  • Comment on De Baerdemaeker et al

    by Sophie Lindgren, Katarina Hallén, Sven‐Erik Ricksten, Ola Stenqvist

  • Isocapnic hyperventilation provides early extubation after head and neck surgery: A prospective randomized trial

    by K. Hallén, P. Jildenstål, O. Stenqvist, J. Oras, S.‐E. Ricksten, S. Lindgren

    Background: Isocapnic hyperventilation (IHV) shortens recovery time after inhalation anaesthesia by increasing ventilation while maintaining a normal airway carbon dioxide (CO2)‐level. One way of performing IHV is to infuse CO2 to the inspiratory limb of a breathing circuit during mechanical hyperventilation (HV). In a prospective randomized study, we compared this IHV technique to a standard emergence procedure (control).Methods: Thirty‐one adult ASA I‐III patients undergoing long‐duration (>3 hours) sevoflurane anaesthesia for major head and neck surgery were included and randomized to IHV‐treatment (n = 16) or control (n = 15). IHV was performed at minute ventilation 13.6 ± 4.3 L/min and CO2 delivery, dosed according to a nomogram tested in a pilot study. Time to extubation and eye‐opening was recorded. Inspired (FICO2) and expired (FETCO2) CO2 and arterial CO2 levels (PaCO2) were monitored. Cognition was tested preoperatively and at 20, 40 and 60 minutes after surgery.Results: Time from turning off the vapourizer to extubation was 13.7 ± 2.5 minutes in the IHV group and 27.4 ± 6.5 minutes in controls (P < .001). Two minutes after extubation, PaCO2 was 6.2 ± 0.5 and 6.2 ± 0.6 kPa in the IHV and control group respectively. In 69% (IHV) vs 53% (controls), post‐operative cognition returned to pre‐operative values within 40 minutes after surgery (NS). Incidences of pain and nausea/vomiting did not differ between groups.Conclusions: In this randomized trial comparing an IHV method with a standard weaning procedure, time to extubation was reduced with 50% in the IHV group. The described IHV method can be used to decrease emergence time from inhalation anaesthesia.


  • Evaluation of a method for isocapnic hyperventilation: a clinical pilot trial

    by K. Hallén, P. Jildenstål, O. Stenqvist, S.‐E. Ricksten, S. Lindgren

    Background: Isocapnic hyperventilation (IHV) is a method that shortens time to extubation after inhalation anaesthesia using hyperventilation (HV) without lowering airway CO2. In a clinical trial on patients undergoing long‐duration sevoflurane anaesthesia for major ear–nose–throat (ENT) surgery, we evaluated the utility of a technique for CO2 delivery (DCO2) to the inspiratory limb of a closed breathing circuit, during HV, to achieve isocapnia.Methods: Fifteen adult ASA 1–3 patients were included. After end of surgery, mechanical HV was started by doubling baseline minute ventilation. Simultaneously, CO2 was delivered and dosed using a nomogram developed in a previous experimental study. Time to extubation and eye opening was recorded. Inspired (FICO2) and expired (FETCO2) CO2 and arterial CO2 levels were monitored during IHV. Cognition was tested pre‐operatively and at 20, 40 and 60 min after surgery.Results: A DCO2 of 285 ± 45 ml/min provided stable isocapnia during HV (13.5 ± 4.1 l/min). The corresponding FICO2 level was 3.0 ± 0.3%. Time from turning off the vaporizer (1.3 ± 0.1 MACage) to extubation (0.2 ± 0.1 MACage) was 11.3 ± 1.8 min after 342 ± 131 min of anaesthesia. PaCO2 and FETCO2 remained at normal levels during and after IHV. In 85% of the patients, post‐operative cognition returned to pre‐operative values within 60 min.Conclusions: In this cohort of patients, a DCO2 nomogram for IHV was validated. The patients were safely extubated shortly after discontinuing long‐term sevoflurane anaesthesia. Perioperatively, there were no adverse effects on arterial blood gases or post‐operative cognition. This technique for IHV can potentially be used to decrease emergence time from inhalation anaesthesia.