Kristin B. Cederquist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kristin B. Cederquist has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Christine D. Keating
Department of Chemistry, The Pennsylvania State University, University Park, Pennsylvania 16802, USA
6 shared publications - Shana Olwyn Kelley
Northwestern University, Chan Zuckerberg Biohub, USA
2 shared publications Alexandre A. Zaragoza
Department of Pharmaceutical Sciences, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Canada
1 shared publicationBing Liu
IMRA America, Inc., 1044 Woodridge Avenue, Ann Arbor, MI 48105, United States
1 shared publicationDarryl J. Bornhop
Department of Chemistry, Vanderbilt University, Nashville, Tennessee 37235, Vanderbilt University Institute of Imaging Science and Department of Radiology and Radiological Sciences, Nashville, Tennessee 37235, Department of Pharmacology, Psychiatry, and Behavioral Science, University of Washington, Seattle, Washington 98195, and Department of Basic Sciences, School of Naturopathic Medicine, Bastyr University, Seattle, Washington 98028
1 shared publicationEdward H. Sargent
Department of Electrical and Computer Engineering, Faculty of Engineering, University of Toronto, Toronto, Canada
1 shared publication
Latest Publications
- 1 January 2017
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 149, 351-357
Laser-fabricated gold nanoparticles for lateral flow immunoassays
- 1 January 2017
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 149, 351-357
Laser-fabricated gold nanoparticles for lateral flow immunoassays
- 19 March 2013
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 90 (4) , 408
Review of Materials Science of DNA
- 19 March 2013
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 90 (4) , 408
Review of Materials Science of DNA
- 1 August 2012
- Published by Elsevier in Current Opinion in Chemical Biology
- Vol. 16 (3-4) , 415-421
Nanostructured biomolecular detectors: pushing performance at the nanoscale
- 1 August 2012
- Published by Elsevier in Current Opinion in Chemical Biology
- Vol. 16 (3-4) , 415-421
Nanostructured biomolecular detectors: pushing performance at the nanoscale
- 3 June 2012
- Published by Springer Nature in Nature Chemistry
- Vol. 4 (8) , 642-648
An ultrasensitive universal detector based on neutralizer displacement
Diagnostic technologies that can provide the simultaneous detection of nucleic acids for gene expression, proteins for host response and small molecules for profiling the human metabolome will have a significant advantage in providing comprehensive patient monitoring. Molecular sensors that report changes in the electrostatics of a sensor's surface on analyte binding have shown unprecedented sensitivity in the detection of charged biomolecules, but do not lend themselves to the detection of small molecules, which do not carry significant charge. Here, we introduce the neutralizer displacement assay that allows charge-based sensing to be applied to any class of molecule irrespective of the analyte charge. The neutralizer displacement assay starts with an aptamer probe bound to a neutralizer. When analyte binding occurs the neutralizer is displaced, which results in a dramatic change in the surface charge for all types of analytes. We have tested the sensitivity, speed and specificity of this system in the detection of a panel of molecules: (deoxy)ribonucleic acid, ribonucleic acid, cocaine, adenosine triphosphate and thrombin.
- 3 June 2012
- Published by Springer Nature in Nature Chemistry
- Vol. 4 (8) , 642-648
An ultrasensitive universal detector based on neutralizer displacement
Diagnostic technologies that can provide the simultaneous detection of nucleic acids for gene expression, proteins for host response and small molecules for profiling the human metabolome will have a significant advantage in providing comprehensive patient monitoring. Molecular sensors that report changes in the electrostatics of a sensor's surface on analyte binding have shown unprecedented sensitivity in the detection of charged biomolecules, but do not lend themselves to the detection of small molecules, which do not carry significant charge. Here, we introduce the neutralizer displacement assay that allows charge-based sensing to be applied to any class of molecule irrespective of the analyte charge. The neutralizer displacement assay starts with an aptamer probe bound to a neutralizer. When analyte binding occurs the neutralizer is displaced, which results in a dramatic change in the surface charge for all types of analytes. We have tested the sensitivity, speed and specificity of this system in the detection of a panel of molecules: (deoxy)ribonucleic acid, ribonucleic acid, cocaine, adenosine triphosphate and thrombin.
- 3 February 2011
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 88 (4) , 386
Book Review of DNA Technology
- 3 February 2011
- Published by American Chemical Society (ACS) in Journal of Chemical Education
- Vol. 88 (4) , 386
Book Review of DNA Technology
- Open Access
- 1 November 2010
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 26 (23) , 18273-18280
Hybridization Efficiency of Molecular Beacons Bound to Gold Nanowires: Effect of Surface Coverage and Target Length
Surface-bound nucleic acid probes designed to adopt specific secondary structures are becoming increasingly important in a range of biosensing applications but remain less well characterized than traditional single-stranded probes, which are typically designed to avoid secondary structure. We report the hybridization efficiency for surface-immobilized hairpin DNA probes. Our probes are molecular beacons, carrying a 3′ dye moiety and a 5′ thiol for attachment to gold nanowires, which serve as both scaffolds for probe attachment and quenchers. Hybridization efficiency was dependent on probe surface coverage, reaching a maximum of ∼90% at intermediate coverages of (1−2) × 1012 probes/cm2 and dropping to ≤20% at higher or lower coverages. Fluorescence intensity did not track with the number of target molecules bound, and was highest for high probe coverage despite the lower bound targets per square centimeter. Backfilling with short thiolated oligoethylene glycol spacers increased hybridization efficiency at low hairpin probe coverages (∼(3−4) × 1011 probes/cm2), but not at higher probe coverages (1 × 1012/cm2). We also evaluated the effect of target length by adding up to 50 nonhybridizing nucleotides to the 3′ or 5′ end of the complementary target sequence. Additional nucleotides on the 3′ end of the complementary target sequence (i.e., the end near the nanowire surface) had a much greater impact on hybridization efficiency as compared to nucleotides added to the 5′ end. This work provides guidance in designing sensors in which surface-bound probes designed to adopt secondary structures are used to detect target sequences from solution.
- 1 November 2010
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 26 (23) , 18273-18280
Open AccessHybridization Efficiency of Molecular Beacons Bound to Gold Nanowires: Effect of Surface Coverage and Target Length
Surface-bound nucleic acid probes designed to adopt specific secondary structures are becoming increasingly important in a range of biosensing applications but remain less well characterized than traditional single-stranded probes, which are typically designed to avoid secondary structure. We report the hybridization efficiency for surface-immobilized hairpin DNA probes. Our probes are molecular beacons, carrying a 3′ dye moiety and a 5′ thiol for attachment to gold nanowires, which serve as both scaffolds for probe attachment and quenchers. Hybridization efficiency was dependent on probe surface coverage, reaching a maximum of ∼90% at intermediate coverages of (1−2) × 1012 probes/cm2 and dropping to ≤20% at higher or lower coverages. Fluorescence intensity did not track with the number of target molecules bound, and was highest for high probe coverage despite the lower bound targets per square centimeter. Backfilling with short thiolated oligoethylene glycol spacers increased hybridization efficiency at low hairpin probe coverages (∼(3−4) × 1011 probes/cm2), but not at higher probe coverages (1 × 1012/cm2). We also evaluated the effect of target length by adding up to 50 nonhybridizing nucleotides to the 3′ or 5′ end of the complementary target sequence. Additional nucleotides on the 3′ end of the complementary target sequence (i.e., the end near the nanowire surface) had a much greater impact on hybridization efficiency as compared to nucleotides added to the 5′ end. This work provides guidance in designing sensors in which surface-bound probes designed to adopt secondary structures are used to detect target sequences from solution.
- 8 June 2010
- Published by Wiley in WIREs Nanomedicine and Nanobiotechnology
- Vol. 2 (6) , 578-600
Encoded anisotropic particles for multiplexed bioanalysis
Encoded anisotropic nano‐ and microparticles represent an exciting new class of detection and identification strategies for bioanalysis. These particles are synthesized in a number of different ways and can be encoded by shape, composition, topographical features, or optical properties. In this review, we explore synthetic methods for the formation of anisotropic encoded particles and evaluate these systems as multiplexed biosensing platforms. Suspension arrays using anisotropic particles have been used to detect a range of biological species including proteins, nucleic acids, spores, cells, and small molecules. Because in many cases a large number of codes should be obtainable, the potential exists for high levels of multiplexing (thousands or more). The bulk of work in this area to date has focused on initial proof of principle synthesis and identification; however, multiplexed bioassays have been demonstrated for a number of different anisotropic carrier particles and are beginning to be adopted in commercial assays.WIREs Nanomed Nanobiotechnol2010 2 578–600This article is categorized under: Diagnostic Tools > In Vitro Nanoparticle-Based Sensing
- 8 June 2010
- Published by Wiley in WIREs Nanomedicine and Nanobiotechnology
- Vol. 2 (6) , 578-600
Encoded anisotropic particles for multiplexed bioanalysis
Encoded anisotropic nano‐ and microparticles represent an exciting new class of detection and identification strategies for bioanalysis. These particles are synthesized in a number of different ways and can be encoded by shape, composition, topographical features, or optical properties. In this review, we explore synthetic methods for the formation of anisotropic encoded particles and evaluate these systems as multiplexed biosensing platforms. Suspension arrays using anisotropic particles have been used to detect a range of biological species including proteins, nucleic acids, spores, cells, and small molecules. Because in many cases a large number of codes should be obtainable, the potential exists for high levels of multiplexing (thousands or more). The bulk of work in this area to date has focused on initial proof of principle synthesis and identification; however, multiplexed bioassays have been demonstrated for a number of different anisotropic carrier particles and are beginning to be adopted in commercial assays.WIREs Nanomed Nanobiotechnol2010 2 578–600This article is categorized under: Diagnostic Tools > In Vitro Nanoparticle-Based Sensing
- 24 February 2009
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 3 (2) , 256-260
Curvature Effects in DNA:Au Nanoparticle Conjugates
DNA-coated Au nanoparticles have myriad applications as versatile building blocks in nanomaterials assembly, powerful amplification tags for bioanalysis, and promising new approaches to medical therapeutics. Characterization, control, and a thorough understanding of the DNA surface interface are essential in the development of these conjugates. A new paper in this issue explores the impact of nanosphere diameter on DNA adsorption and demonstrates that particle curvature plays an important role in controlling the DNA surface density. The study proposes a model that can be used to predict DNA packing on nonspherical particles and validates it using Au nanorods. This work paves the way for improved understanding of the DNA:Au interface in these versatile bioconjugates.
- 24 February 2009
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 3 (2) , 256-260
Curvature Effects in DNA:Au Nanoparticle Conjugates
DNA-coated Au nanoparticles have myriad applications as versatile building blocks in nanomaterials assembly, powerful amplification tags for bioanalysis, and promising new approaches to medical therapeutics. Characterization, control, and a thorough understanding of the DNA surface interface are essential in the development of these conjugates. A new paper in this issue explores the impact of nanosphere diameter on DNA adsorption and demonstrates that particle curvature plays an important role in controlling the DNA surface density. The study proposes a model that can be used to predict DNA packing on nonspherical particles and validates it using Au nanorods. This work paves the way for improved understanding of the DNA:Au interface in these versatile bioconjugates.
- 15 July 2008
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 24 (16) , 9162-9171
Molecular Beacon−Metal Nanowire Interface: Effect of Probe Sequence and Surface Coverage on Sensor Performance
We report the effect of surface coverage and sequence on the performance of 5′ thiolated, 3′ fluorophore-labeled DNA hairpin probes bound to Au/Ag striped (“barcoded”) metal nanowires. Coverage was controlled by varying probe concentration, buffer ionic strength, and by addition of short hydroxy-terminated alkanethiol diluent molecules during probe assembly onto the nanowire surface. Surface dilution of the surface-bound probes with a ω-hydroxyl alkanethiol, a commonly accepted practice in the surface-bound DNA literature, did not appreciably improve sensor performance as compared to similar probe coverages without hydroxyalkanethiol diluents; this finding underscores the differences between the molecular beacon probes used here and more traditional nonfluorescent, random coil probes. We found that intermediate probe coverage of ∼1012 molecules/cm2 gave the best discrimination between presence and absence of a target sequence. Because we are interested in multiplexed assays, we also compared several beacon probe sequences having different stabilities for secondary structure formation in solution; we found that both probe surface coverage and sensor performance varied for different probe sequences. When five different molecular beacon probes, each bound to barcoded nanowires, were used in a multiplexed, wash-free assay for target oligonucleotides corresponding to viral nucleic acid sequences, these differences in probe performance did not prevent accurate target identification. We anticipate that the findings described here will also be relevant to other applications involving molecular beacons or other structured nucleic acid probes immobilized on metal surfaces.
- 15 July 2008
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 24 (16) , 9162-9171
Molecular Beacon−Metal Nanowire Interface: Effect of Probe Sequence and Surface Coverage on Sensor Performance
We report the effect of surface coverage and sequence on the performance of 5′ thiolated, 3′ fluorophore-labeled DNA hairpin probes bound to Au/Ag striped (“barcoded”) metal nanowires. Coverage was controlled by varying probe concentration, buffer ionic strength, and by addition of short hydroxy-terminated alkanethiol diluent molecules during probe assembly onto the nanowire surface. Surface dilution of the surface-bound probes with a ω-hydroxyl alkanethiol, a commonly accepted practice in the surface-bound DNA literature, did not appreciably improve sensor performance as compared to similar probe coverages without hydroxyalkanethiol diluents; this finding underscores the differences between the molecular beacon probes used here and more traditional nonfluorescent, random coil probes. We found that intermediate probe coverage of ∼1012 molecules/cm2 gave the best discrimination between presence and absence of a target sequence. Because we are interested in multiplexed assays, we also compared several beacon probe sequences having different stabilities for secondary structure formation in solution; we found that both probe surface coverage and sensor performance varied for different probe sequences. When five different molecular beacon probes, each bound to barcoded nanowires, were used in a multiplexed, wash-free assay for target oligonucleotides corresponding to viral nucleic acid sequences, these differences in probe performance did not prevent accurate target identification. We anticipate that the findings described here will also be relevant to other applications involving molecular beacons or other structured nucleic acid probes immobilized on metal surfaces.
- 1 October 2007
- Published by Taylor & Francis in Nanomedicine
- Vol. 2 (5) , 695-710
Metallic Barcodes for Multiplexed Bioassays
Both detection and postdiagnosis monitoring are critical for cancer isolation and treatment. Particle-based sensing strategies could help to address these medical needs. This review describes barcoded metallic nanowires as particle scaffolds for multiplexed detection of antigens or nucleic acids. Barcode patterns are compositionally encoded as stripes of gold and silver metal along the nanowire length during fabrication by templated electrodeposition. Particle identification is accomplished using reflectance optical microscopy and can be coupled with fluorescence readout of antigen- or nucleic acid-binding events. Several approaches to multiplexed biodetection based on barcoded nanowires will be described and the potential for these particles in cancer detection will be discussed.
- 1 October 2007
- Published by Taylor & Francis in Nanomedicine
- Vol. 2 (5) , 695-710
Metallic Barcodes for Multiplexed Bioassays
Both detection and postdiagnosis monitoring are critical for cancer isolation and treatment. Particle-based sensing strategies could help to address these medical needs. This review describes barcoded metallic nanowires as particle scaffolds for multiplexed detection of antigens or nucleic acids. Barcode patterns are compositionally encoded as stripes of gold and silver metal along the nanowire length during fabrication by templated electrodeposition. Particle identification is accomplished using reflectance optical microscopy and can be coupled with fluorescence readout of antigen- or nucleic acid-binding events. Several approaches to multiplexed biodetection based on barcoded nanowires will be described and the potential for these particles in cancer detection will be discussed.