KCKristin B. Cederquist

Kristin B. Cederquist

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kristin B. Cederquist has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Christine D. Keating

    Department of Chemistry, The Pennsylvania State University, University Park, Pennsylvania 16802, USA

    6 shared publications
  • Shana Olwyn Kelley

    Northwestern University, Chan Zuckerberg Biohub, USA

    2 shared publications
  • Alexandre A. Zaragoza

    Department of Pharmaceutical Sciences, Leslie Dan Faculty of Pharmacy, University of Toronto, Toronto, Canada

    1 shared publication
  • Bing Liu

    IMRA America, Inc., 1044 Woodridge Avenue, Ann Arbor, MI 48105, United States

    1 shared publication
  • Darryl J. Bornhop

    Department of Chemistry, Vanderbilt University, Nashville, Tennessee 37235, Vanderbilt University Institute of Imaging Science and Department of Radiology and Radiological Sciences, Nashville, Tennessee 37235, Department of Pharmacology, Psychiatry, and Behavioral Science, University of Washington, Seattle, Washington 98195, and Department of Basic Sciences, School of Naturopathic Medicine, Bastyr University, Seattle, Washington 98028

    1 shared publication
  • Edward H. Sargent

    Department of Electrical and Computer Engineering, Faculty of Engineering, University of Toronto, Toronto, Canada

    1 shared publication

Latest Publications

  • Laser-fabricated gold nanoparticles for lateral flow immunoassays

    by Kristin B. Cederquist, Bing Liu, Megan R. Grima, Peter J. Dalack, Jordan T. Mahorn


  • An ultrasensitive universal detector based on neutralizer displacement

    by Jagotamoy Das, Kristin B. Cederquist, Alexandre A. Zaragoza, Paul E. Lee, Edward H. Sargent, Shana O. Kelley

    Diagnostic technologies that can provide the simultaneous detection of nucleic acids for gene expression, proteins for host response and small molecules for profiling the human metabolome will have a significant advantage in providing comprehensive patient monitoring. Molecular sensors that report changes in the electrostatics of a sensor's surface on analyte binding have shown unprecedented sensitivity in the detection of charged biomolecules, but do not lend themselves to the detection of small molecules, which do not carry significant charge. Here, we introduce the neutralizer displacement assay that allows charge-based sensing to be applied to any class of molecule irrespective of the analyte charge. The neutralizer displacement assay starts with an aptamer probe bound to a neutralizer. When analyte binding occurs the neutralizer is displaced, which results in a dramatic change in the surface charge for all types of analytes. We have tested the sensitivity, speed and specificity of this system in the detection of a panel of molecules: (deoxy)ribonucleic acid, ribonucleic acid, cocaine, adenosine triphosphate and thrombin.


  • Open Access

    Hybridization Efficiency of Molecular Beacons Bound to Gold Nanowires: Effect of Surface Coverage and Target Length

    by Kristin B. Cederquist, Christine D. Keating

    Surface-bound nucleic acid probes designed to adopt specific secondary structures are becoming increasingly important in a range of biosensing applications but remain less well characterized than traditional single-stranded probes, which are typically designed to avoid secondary structure. We report the hybridization efficiency for surface-immobilized hairpin DNA probes. Our probes are molecular beacons, carrying a 3′ dye moiety and a 5′ thiol for attachment to gold nanowires, which serve as both scaffolds for probe attachment and quenchers. Hybridization efficiency was dependent on probe surface coverage, reaching a maximum of ∼90% at intermediate coverages of (1−2) × 1012 probes/cm2 and dropping to ≤20% at higher or lower coverages. Fluorescence intensity did not track with the number of target molecules bound, and was highest for high probe coverage despite the lower bound targets per square centimeter. Backfilling with short thiolated oligoethylene glycol spacers increased hybridization efficiency at low hairpin probe coverages (∼(3−4) × 1011 probes/cm2), but not at higher probe coverages (1 × 1012/cm2). We also evaluated the effect of target length by adding up to 50 nonhybridizing nucleotides to the 3′ or 5′ end of the complementary target sequence. Additional nucleotides on the 3′ end of the complementary target sequence (i.e., the end near the nanowire surface) had a much greater impact on hybridization efficiency as compared to nucleotides added to the 5′ end. This work provides guidance in designing sensors in which surface-bound probes designed to adopt secondary structures are used to detect target sequences from solution.


  • Encoded anisotropic particles for multiplexed bioanalysis

    by Kristin B. Cederquist, Stacey L. Dean, Christine D. Keating

    Encoded anisotropic nano‐ and microparticles represent an exciting new class of detection and identification strategies for bioanalysis. These particles are synthesized in a number of different ways and can be encoded by shape, composition, topographical features, or optical properties. In this review, we explore synthetic methods for the formation of anisotropic encoded particles and evaluate these systems as multiplexed biosensing platforms. Suspension arrays using anisotropic particles have been used to detect a range of biological species including proteins, nucleic acids, spores, cells, and small molecules. Because in many cases a large number of codes should be obtainable, the potential exists for high levels of multiplexing (thousands or more). The bulk of work in this area to date has focused on initial proof of principle synthesis and identification; however, multiplexed bioassays have been demonstrated for a number of different anisotropic carrier particles and are beginning to be adopted in commercial assays.WIREs Nanomed Nanobiotechnol2010 2 578–600This article is categorized under: Diagnostic Tools > In Vitro Nanoparticle-Based Sensing


  • Curvature Effects in DNA:Au Nanoparticle Conjugates

    by Kristin B. Cederquist, Christine D. Keating

    DNA-coated Au nanoparticles have myriad applications as versatile building blocks in nanomaterials assembly, powerful amplification tags for bioanalysis, and promising new approaches to medical therapeutics. Characterization, control, and a thorough understanding of the DNA surface interface are essential in the development of these conjugates. A new paper in this issue explores the impact of nanosphere diameter on DNA adsorption and demonstrates that particle curvature plays an important role in controlling the DNA surface density. The study proposes a model that can be used to predict DNA packing on nonspherical particles and validates it using Au nanorods. This work paves the way for improved understanding of the DNA:Au interface in these versatile bioconjugates.


  • Molecular Beacon−Metal Nanowire Interface: Effect of Probe Sequence and Surface Coverage on Sensor Performance

    by Kristin B. Cederquist, Rebecca Stoermer Golightly, Christine D. Keating

    We report the effect of surface coverage and sequence on the performance of 5′ thiolated, 3′ fluorophore-labeled DNA hairpin probes bound to Au/Ag striped (“barcoded”) metal nanowires. Coverage was controlled by varying probe concentration, buffer ionic strength, and by addition of short hydroxy-terminated alkanethiol diluent molecules during probe assembly onto the nanowire surface. Surface dilution of the surface-bound probes with a ω-hydroxyl alkanethiol, a commonly accepted practice in the surface-bound DNA literature, did not appreciably improve sensor performance as compared to similar probe coverages without hydroxyalkanethiol diluents; this finding underscores the differences between the molecular beacon probes used here and more traditional nonfluorescent, random coil probes. We found that intermediate probe coverage of ∼1012 molecules/cm2 gave the best discrimination between presence and absence of a target sequence. Because we are interested in multiplexed assays, we also compared several beacon probe sequences having different stabilities for secondary structure formation in solution; we found that both probe surface coverage and sensor performance varied for different probe sequences. When five different molecular beacon probes, each bound to barcoded nanowires, were used in a multiplexed, wash-free assay for target oligonucleotides corresponding to viral nucleic acid sequences, these differences in probe performance did not prevent accurate target identification. We anticipate that the findings described here will also be relevant to other applications involving molecular beacons or other structured nucleic acid probes immobilized on metal surfaces.


  • Metallic Barcodes for Multiplexed Bioassays

    by Sarah E Brunker, Kristin B Cederquist, Christine D Keating

    Both detection and postdiagnosis monitoring are critical for cancer isolation and treatment. Particle-based sensing strategies could help to address these medical needs. This review describes barcoded metallic nanowires as particle scaffolds for multiplexed detection of antigens or nucleic acids. Barcode patterns are compositionally encoded as stripes of gold and silver metal along the nanowire length during fabrication by templated electrodeposition. Particle identification is accomplished using reflectance optical microscopy and can be coupled with fluorescence readout of antigen- or nucleic acid-binding events. Several approaches to multiplexed biodetection based on barcoded nanowires will be described and the potential for these particles in cancer detection will be discussed.