Richard Celestre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Richard Celestre has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
- Howard A. Padmore
Physics Department, Arizona State University, Tempe, AZ 85282, USA
13 shared publications Tony Warwick
Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
8 shared publicationsAlastair A. MacDowell
Lawrence Berkeley National Laboratory 1 , 1 Cyclotron Road, Berkeley, California 94720, USA
6 shared publicationsValeriy V. Yashchuk
Lawrence Berkeley National Lab. (United States)
5 shared publicationsEdward E. Domning
Lawrence Berkeley National Lab. (United States)
4 shared publicationsSheng Yuan
Lawrence Berkeley National Lab. (United States)
4 shared publications
Latest Publications
- Open Access
- 18 December 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (51) , eabc4904
An ultrahigh-resolution soft x-ray microscope for quantitative analysis of chemically heterogeneous nanomaterials
A novel ultrahigh-resolution x-ray microscope achieves 8-nm spatial resolution and accurately maps chemistry in nanomaterials.
- 18 December 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (51) , eabc4904
Open AccessAn ultrahigh-resolution soft x-ray microscope for quantitative analysis of chemically heterogeneous nanomaterials
A novel ultrahigh-resolution x-ray microscope achieves 8-nm spatial resolution and accurately maps chemistry in nanomaterials.
- Open Access
- 6 September 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (9) , eaax3009
Multimodal x-ray and electron microscopy of the Allende meteorite
Multimodal x-ray and electron microscopy are developed to provide structural, elemental and chemical insights into heterogeneous systems.
- 6 September 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (9) , eaax3009
Open AccessMultimodal x-ray and electron microscopy of the Allende meteorite
Multimodal x-ray and electron microscopy are developed to provide structural, elemental and chemical insights into heterogeneous systems.
- Open Access
- 2 March 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 1-7
Three-dimensional localization of nanoscale battery reactions using soft X-ray tomography
Battery function is determined by the efficiency and reversibility of the electrochemical phase transformations at solid electrodes. The microscopic tools available to study the chemical states of matter with the required spatial resolution and chemical specificity are intrinsically limited when studying complex architectures by their reliance on two-dimensional projections of thick material. Here, we report the development of soft X-ray ptychographic tomography, which resolves chemical states in three dimensions at 11 nm spatial resolution. We study an ensemble of nano-plates of lithium iron phosphate extracted from a battery electrode at 50% state of charge. Using a set of nanoscale tomograms, we quantify the electrochemical state and resolve phase boundaries throughout the volume of individual nanoparticles. These observations reveal multiple reaction points, intra-particle heterogeneity, and size effects that highlight the importance of multi-dimensional analytical tools in providing novel insight to the design of the next generation of high-performance devices.
- 2 March 2018
- Published by Springer Nature in Nature Communications
- Vol. 9 (1) , 1-7
Open AccessThree-dimensional localization of nanoscale battery reactions using soft X-ray tomography
Battery function is determined by the efficiency and reversibility of the electrochemical phase transformations at solid electrodes. The microscopic tools available to study the chemical states of matter with the required spatial resolution and chemical specificity are intrinsically limited when studying complex architectures by their reliance on two-dimensional projections of thick material. Here, we report the development of soft X-ray ptychographic tomography, which resolves chemical states in three dimensions at 11 nm spatial resolution. We study an ensemble of nano-plates of lithium iron phosphate extracted from a battery electrode at 50% state of charge. Using a set of nanoscale tomograms, we quantify the electrochemical state and resolve phase boundaries throughout the volume of individual nanoparticles. These observations reveal multiple reaction points, intra-particle heterogeneity, and size effects that highlight the importance of multi-dimensional analytical tools in providing novel insight to the design of the next generation of high-performance devices.
- 6 February 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 110 (6) , 063101
Near-edge X-ray refraction fine structure microscopy
We demonstrate a method for obtaining increased spatial resolution and specificity in nanoscale chemical composition maps through the use of full refractive reference spectra in soft x-ray spectro-microscopy. Using soft x-ray ptychography, we measure both the absorption and refraction of x-rays through pristine reference materials as a function of photon energy and use these reference spectra as the basis for decomposing spatially resolved spectra from a heterogeneous sample, thereby quantifying the composition at high resolution. While conventional instruments are limited to absorption contrast, our novel refraction based method takes advantage of the strongly energy dependent scattering cross-section and can see nearly five-fold improved spatial resolution on resonance.
- 6 February 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 110 (6) , 063101
Near-edge X-ray refraction fine structure microscopy
We demonstrate a method for obtaining increased spatial resolution and specificity in nanoscale chemical composition maps through the use of full refractive reference spectra in soft x-ray spectro-microscopy. Using soft x-ray ptychography, we measure both the absorption and refraction of x-rays through pristine reference materials as a function of photon energy and use these reference spectra as the basis for decomposing spatially resolved spectra from a heterogeneous sample, thereby quantifying the composition at high resolution. While conventional instruments are limited to absorption contrast, our novel refraction based method takes advantage of the strongly energy dependent scattering cross-section and can see nearly five-fold improved spatial resolution on resonance.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 636 (10823654) , 1057-1059
Characterisation of a thin, fully-depleted, back-illuminated SOI pixel sensor with soft X-ray radiation
THE availability of the Silicon on Insulator (SOI) process at OKI Inc. (now Lapis Semiconductor) with an handle wafer of moderate resistivity and contacts through the buried oxide layer has promoted a significant R&D on monolithic Si pixel sensors for charged particle tracking and imaging. The SOI technology has a number of potential advantages compared to bulk CMOS processes for the fabrication of pixel sensors. Past the first proof of principle of beam particle detection with an SOI pixel sensor [1], the R&D had to solve the back-gating effect, which limited the practical depletion voltage and thus the depleted thickness. The use of a buried p-well to protect the CMOS electronics from the potential on the handle wafer has successfully solved this problem and SOI pixels developed by KEK and by our group (LBNL, UCSC and INFN, Padova) have demonstrated full functionality up to 90 V and above [2], [3], [4]. This corresponds to a depleted thicknesses of ≃130 μm for a nominal resistivity of 700 O·cm.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 636 (10823654) , 1057-1059
Characterisation of a thin, fully-depleted, back-illuminated SOI pixel sensor with soft X-ray radiation
THE availability of the Silicon on Insulator (SOI) process at OKI Inc. (now Lapis Semiconductor) with an handle wafer of moderate resistivity and contacts through the buried oxide layer has promoted a significant R&D on monolithic Si pixel sensors for charged particle tracking and imaging. The SOI technology has a number of potential advantages compared to bulk CMOS processes for the fabrication of pixel sensors. Past the first proof of principle of beam particle detection with an SOI pixel sensor [1], the R&D had to solve the back-gating effect, which limited the practical depletion voltage and thus the depleted thickness. The use of a buried p-well to protect the CMOS electronics from the potential on the handle wafer has successfully solved this problem and SOI pixels developed by KEK and by our group (LBNL, UCSC and INFN, Padova) have demonstrated full functionality up to 90 V and above [2], [3], [4]. This corresponds to a depleted thicknesses of ≃130 μm for a nominal resistivity of 700 O·cm.
- 8 September 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8139, 813907
An experimental apparatus for diffraction-limited soft x-ray nano-focusing
Realizing the experimental potential of high-brightness, next generation synchrotron and free-electron laser light sources requires the development of reflecting x-ray optics capable of wavefront preservation and high-resolution nano-focusing. At the Advanced Light Source (ALS) beamline 5.3.1, we are developing broadly applicable, high-accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad slope measurement accuracy for diffraction-limited Kirkpatrick-Baez (KB) mirrors. The at-wavelength methodology we are developing relies on a series of wavefront-sensing tests with increasing accuracy and sensitivity, including scanning-slit Hartmann tests, grating-based lateral shearing interferometry, and quantitative knife-edge testing. We describe the original experimental techniques and alignment methodology that have enabled us to optimally set a bendable KB mirror to achieve a focused, FWHM spot size of 150 nm, with 1 nm (1.24 keV) photons at 3.7 mrad numerical aperture. The predictions of wavefront measurement are confirmed by the knife-edge testing. The side-profiled elliptically bent mirror used in these one-dimensional focusing experiments was originally designed for a much different glancing angle and conjugate distances. Visible-light long-trace profilometry was used to pre-align the mirror before installation at the beamline. This work demonstrates that high-accuracy, at-wavelength wavefront-slope feedback can be used to optimize the pitch, roll, and mirror-bending forces in situ, using procedures that are deterministic and repeatable.
- 8 September 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8139, 813907
An experimental apparatus for diffraction-limited soft x-ray nano-focusing
Realizing the experimental potential of high-brightness, next generation synchrotron and free-electron laser light sources requires the development of reflecting x-ray optics capable of wavefront preservation and high-resolution nano-focusing. At the Advanced Light Source (ALS) beamline 5.3.1, we are developing broadly applicable, high-accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad slope measurement accuracy for diffraction-limited Kirkpatrick-Baez (KB) mirrors. The at-wavelength methodology we are developing relies on a series of wavefront-sensing tests with increasing accuracy and sensitivity, including scanning-slit Hartmann tests, grating-based lateral shearing interferometry, and quantitative knife-edge testing. We describe the original experimental techniques and alignment methodology that have enabled us to optimally set a bendable KB mirror to achieve a focused, FWHM spot size of 150 nm, with 1 nm (1.24 keV) photons at 3.7 mrad numerical aperture. The predictions of wavefront measurement are confirmed by the knife-edge testing. The side-profiled elliptically bent mirror used in these one-dimensional focusing experiments was originally designed for a much different glancing angle and conjugate distances. Visible-light long-trace profilometry was used to pre-align the mirror before installation at the beamline. This work demonstrates that high-accuracy, at-wavelength wavefront-slope feedback can be used to optimize the pitch, roll, and mirror-bending forces in situ, using procedures that are deterministic and repeatable.
- 19 August 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7801, 78010D
At-wavelength optical metrology development at the ALS
Nano-focusing and brightness preservation for ever brighter synchrotron radiation and free electron laser beamlines require surface slope tolerances of x-ray optics on the order of 100 nrad. While the accuracy of fabrication and ex situ metrology of x-ray mirrors has improved over time, beamline in situ performance of the optics is often limited by application specific factors such as x-ray beam heat loading, temperature drift, alignment, vibration, etc. In the present work, we discuss the recent results from the Advanced Light Source developing high accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad accuracy surface slope measurements with reflecting x-ray optics. The techniques will ultimately allow closed-loop feedback systems to be implemented for x-ray nano-focusing. In addition, we present a dedicated metrology beamline endstation, applicable to a wide range of in situ metrology and test experiments. The design and performance of a bendable Kirkpatrick-Baez (KB) mirror with active temperature stabilization will also be presented. The mirror is currently used to study, refine, and optimize in situ mirror alignment, bending and metrology methods essential for nano-focusing application.
- 19 August 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7801, 78010D
At-wavelength optical metrology development at the ALS
Nano-focusing and brightness preservation for ever brighter synchrotron radiation and free electron laser beamlines require surface slope tolerances of x-ray optics on the order of 100 nrad. While the accuracy of fabrication and ex situ metrology of x-ray mirrors has improved over time, beamline in situ performance of the optics is often limited by application specific factors such as x-ray beam heat loading, temperature drift, alignment, vibration, etc. In the present work, we discuss the recent results from the Advanced Light Source developing high accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad accuracy surface slope measurements with reflecting x-ray optics. The techniques will ultimately allow closed-loop feedback systems to be implemented for x-ray nano-focusing. In addition, we present a dedicated metrology beamline endstation, applicable to a wide range of in situ metrology and test experiments. The design and performance of a bendable Kirkpatrick-Baez (KB) mirror with active temperature stabilization will also be presented. The mirror is currently used to study, refine, and optimize in situ mirror alignment, bending and metrology methods essential for nano-focusing application.
- Open Access
- 19 August 2010
- Published by Hindawi Limited in X-Ray Optics and Instrumentation
- Vol. 2010, 1-9
Elliptically Bent X-Ray Mirrors with Active Temperature Stabilization
We present details of design of elliptically bent Kirkpatrick-Baez mirrors developed and successfully used at the advanced light source for submicron focusing. A distinctive feature of the mirror design is an active temperature stabilization based on a Peltier element attached directly to the mirror body. The design and materials have been carefully optimized to provide high heat conductance between the mirror body and substrate. We describe the experimental procedures used when assembling and precisely shaping the mirrors, with special attention paid to laboratory testing of the mirror-temperature stabilization. For this purpose, the temperature dependence of the surface slope profile of a specially fabricated test mirror placed inside a temperature-controlled container was measured. We demonstrate that with active mirror-temperature stabilization, a change of the surrounding temperature by more than 3 K does not noticeably affect the mirror figure. Without temperature stabilization, the rms slope error is changed by approximately 1.5 rad (primarily defocus) under the same conditions.- 19 August 2010
- Published by Hindawi Limited in X-Ray Optics and Instrumentation
- Vol. 2010, 1-9
Open AccessElliptically Bent X-Ray Mirrors with Active Temperature Stabilization
We present details of design of elliptically bent Kirkpatrick-Baez mirrors developed and successfully used at the advanced light source for submicron focusing. A distinctive feature of the mirror design is an active temperature stabilization based on a Peltier element attached directly to the mirror body. The design and materials have been carefully optimized to provide high heat conductance between the mirror body and substrate. We describe the experimental procedures used when assembling and precisely shaping the mirrors, with special attention paid to laboratory testing of the mirror-temperature stabilization. For this purpose, the temperature dependence of the surface slope profile of a specially fabricated test mirror placed inside a temperature-controlled container was measured. We demonstrate that with active mirror-temperature stabilization, a change of the surrounding temperature by more than 3 K does not noticeably affect the mirror figure. Without temperature stabilization, the rms slope error is changed by approximately 1.5 rad (primarily defocus) under the same conditions. - 1 March 2009
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 80 (3) , 035108
A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source
A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 μm spot of ∼5×109 photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick–Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 μm are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (∼0.2 μm) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5×10−5 strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (∼150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.
- 1 March 2009
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 80 (3) , 035108
A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source
A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 μm spot of ∼5×109 photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick–Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 μm are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (∼0.2 μm) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5×10−5 strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (∼150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.
- 1 January 2009
- Published by Optica Publishing Group
- p. FThT2
At-wavelength and optical metrology of bendable x-ray optics for nanofocusing at the ALS
We describe a new R&D program at the Advanced Light Source, LBNL, directed to establish both at-wavelength and conventional optical-metrology techniques suitable to characterize the surface profile of super-high-quality x-ray optics with sub-microradian precision.
- 1 January 2009
- Published by Optica Publishing Group
- p. FThT2
At-wavelength and optical metrology of bendable x-ray optics for nanofocusing at the ALS
We describe a new R&D program at the Advanced Light Source, LBNL, directed to establish both at-wavelength and conventional optical-metrology techniques suitable to characterize the surface profile of super-high-quality x-ray optics with sub-microradian precision.